Normalized to: Bhargava, Y.
[1]
oai:arXiv.org:1906.10595 [pdf] - 1912963
Spectro-timing analysis of MAXI J1535-571 using AstroSat
Submitted: 2019-06-25
We report the results of the analysis of an AstroSat observation of the Black
Hole candidate MAXI J1535-571 during its Hard Intermediate state. We studied
the evolution of the spectral and timing parameters of the source during the
observation. The observation covered a period of $\sim$5 days and consisted of
66 continuous segments, corresponding to individual spacecraft orbits. Each
segment was analysed independently. The source count rate increased roughly
linearly by $\sim$30 %. We modelled the spectra as a combination of radiation
from a thermal disk component and a power-law. The timing analysis revealed the
presence of strong Quasi Periodic Oscillations with centroid frequency
$\nu_{\rm{QPO}}$ fluctuating in the range 1.7-3.0 Hz. We found a tight
correlation between the QPO centroid frequency $\nu_{\rm{QPO}}$ and the
power-law spectral index $\Gamma$, while $\nu_{\rm{QPO}}$ appeared not to be
correlated with the linearly-increasing flux itself. We discuss the
implications of these results on physical models of accretion.
[2]
oai:arXiv.org:1810.07724 [pdf] - 1773098
Explaining the asymmetric line profile in Cepheus X-4 with spectral
variation across pulse phase
Submitted: 2018-10-17
The high mass X-ray binary Cep X-4, during its 2014 outburst, showed evidence
for an asymmetric cyclotron line in its hard X-ray spectrum. The 2014 spectrum
provides one of the clearest cases of an asymmetric line profile among all
studied sources with Cyclotron Resonance Scattering Features (CRSF). We present
a phase-resolved analysis of NuSTAR and Suzaku data taken at the peak and
during the decline phases of this outburst. We find that the pulse-phased
resolved spectra are well-fit by a single, symmetric cyclotron feature. The fit
parameters vary strongly with pulse phase: most notably the central energy and
depth of the cyclotron feature, the slope of the power-law component, and the
absorbing column density. We synthesise a phase averaged spectrum using the
best-fit parameters for these individual pulse phases, and find that this
combined model spectrum has a similar asymmetry in the cyclotron features as
discovered in phase-averaged data. We conclude that the pulse phase resolved
analysis with simple symmetric line profiles when combined can explain the
asymmetry detected in the phase-averaged data.
[3]
oai:arXiv.org:1709.07441 [pdf] - 1592631
A precise measurement of the orbital period parameters of Cygnus X-3
Bhargava, Yash;
Rao, A. R.;
Singh, K. P.;
Choudhury, Manojendu;
Bhattacharyya, S.;
Chandra, S.;
Dewangan, G. C.;
Mukerjee, K.;
Stewart, G. C.;
Bhattacharya, D.;
Mithun, N. P. S.;
Vadawale, S. V.
Submitted: 2017-09-21, last modified: 2017-11-25
We present X-ray light curves of Cygnus X-3 as measured by the recently
launched AstroSat satellite. The light curve folded over the binary period of
4.8 hours shows a remarkable stability over the past 45 years and we find that
we can use this information to measure the zero point to better than 100 s. We
revisit the historical binary phase measurements and examine the stability of
the binary period over 45 years. We present a new binary ephemeris with the
period and period derivative determined to an accuracy much better than
previously reported. We do not find any evidence for a second derivative in the
period variation. The precise binary period measurements, however, indicate a
hint of short term episodic variations in periods. Interestingly, these short
term period variations coincide with the period of enhanced jet activity
exhibited by the source. We discuss the implications of these observations on
the nature of the binary system.
[4]
oai:arXiv.org:1608.06038 [pdf] - 1580161
Charged Particle Monitor on the AstroSat mission
Rao, A. R.;
Patil, M. H.;
Bhargava, Yash;
Khanna, Rakesh;
Hingar, M. K.;
Kutty, A. P. K.;
Malkar, J. P.;
Basak, Rupal;
Sreekumar, S.;
Samuel, Essy;
Priya, P.;
Vinod, P.;
Bhattacharya, D.;
Bhalerao, V.;
Vadawale, S. V.;
Mithun, N. P. S.;
Pandiyan, R.;
Subbarao, K.;
Seetha, S.;
Sarma, K. Suryanarayana
Submitted: 2016-08-21
Charged Particle Monitor (CPM) on-board the AstroSat satellite is an
instrument designed to detect the flux of charged particles at the satellite
location. A Cesium Iodide Thallium (CsI(Tl)) crystal is used with a Kapton
window to detect protons with energies greater than 1 MeV. The ground
calibration of CPM was done using gamma-rays from radioactive sources and
protons from particle accelerators. Based on the ground calibration results,
energy deposition above 1 MeV are accepted and particle counts are recorded. It
is found that CPM counts are steady and the signal for the onset and exit of
South Atlantic Anomaly (SAA) region are generated in a very reliable and stable
manner.