Normalized to: Betti, M.
[1]
oai:arXiv.org:1911.01122 [pdf] - 2097251
Carbon nanotubes as anisotropic target for dark matter
Submitted: 2019-11-04
Directional detection of Dark Matter (DM) particles could be accomplished by
studying either ion or electron recoils in large arrays of parallel carbon
nanotubes. For instance, a MeV mass DM particle could scatter off a lattice
electron, resulting in the transfer of sufficient energy to eject the electron
from the nanotube surface. The electron can eventually be detected whenever an
external electric field is added to drive it from the open ends of the array.
This detection scheme would offer an anisotropic response and could be used to
select an orientation of the target with respect to the DM wind. A compact
sensor, in which the cathode element is substituted with a dense array of
parallel carbon nanotubes, could serve as the basic detection unit which - if
adequately replicated - would allow to explore a significant region of light DM
mass and cross-section. A similar detection scheme could be used to detect DM
particles with mass in the GeV range scattering off the surface of a CNT and
ejecting a carbon ion. We report about the Monte Carlo simulations of such a
system and the R&D towards a detector prototype.
[2]
oai:arXiv.org:1902.05508 [pdf] - 1970174
Neutrino physics with the PTOLEMY project: active neutrino properties
and the light sterile case
PTOLEMY collaboration;
Betti, M. G.;
Biasotti, M.;
Boscá, A.;
Calle, F.;
Cavoto, G.;
Chang, C.;
Cocco, A. G.;
Colijn, A. P.;
Conrad, J.;
D'Ambrosio, N.;
De Groot, N.;
de Salas, P. F.;
Faverzani, M.;
Ferella, A.;
Ferri, E.;
Garcia-Abia, P.;
García-Cortés, I.;
Gomez-Tejedor, G. Garcia;
Gariazzo, S.;
Gatti, F.;
Gentile, C.;
Giachero, A.;
Gudmundsson, J. E.;
Hochberg, Y.;
Kahn, Y.;
Kievsky, A.;
Lisanti, M.;
Mancini-Terracciano, C.;
Mangano, G.;
Marcucci, L. E.;
Mariani, C.;
Martínez, J.;
Messina, M.;
Molinero-Vela, A.;
Monticone, E.;
Moroño, A.;
Nucciotti, A.;
Pandolfi, F.;
Parlati, S.;
Pastor, S.;
Pedrós, J.;
Heros, C. Pérez de los;
Pisanti, O.;
Polosa, A. D.;
Puiu, A.;
Rago, I.;
Raitses, Y.;
Rajteri, M.;
Rossi, N.;
Rucandio, I.;
Santorelli, R.;
Schaeffner, K.;
Tully, C. G.;
Viviani, M.;
Zhao, F.;
Zurek, K. M.
Submitted: 2019-02-14, last modified: 2019-09-30
The PTOLEMY project aims to develop a scalable design for a Cosmic Neutrino
Background (CNB) detector, the first of its kind and the only one conceived
that can look directly at the image of the Universe encoded in neutrino
background produced in the first second after the Big Bang. The scope of the
work for the next three years is to complete the conceptual design of this
detector and to validate with direct measurements that the non-neutrino
backgrounds are below the expected cosmological signal. In this paper we
discuss in details the theoretical aspects of the experiment and its physics
goals. In particular, we mainly address three issues. First we discuss the
sensitivity of PTOLEMY to the standard neutrino mass scale. We then study the
perspectives of the experiment to detect the CNB via neutrino capture on
tritium as a function of the neutrino mass scale and the energy resolution of
the apparatus. Finally, we consider an extra sterile neutrino with mass in the
eV range, coupled to the active states via oscillations, which has been
advocated in view of neutrino oscillation anomalies. This extra state would
contribute to the tritium decay spectrum, and its properties, mass and mixing
angle, could be studied by analyzing the features in the beta decay electron
spectrum.
[3]
oai:arXiv.org:1810.06703 [pdf] - 1875231
A Design for an Electromagnetic Filter for Precision Energy Measurements
at the Tritium Endpoint
Betti, M. G.;
Biasotti, M.;
Bosca, A.;
Calle, F.;
Carabe-Lopez, J.;
Cavoto, G.;
Chang, C.;
Chung, W.;
Cocco, A. G.;
Colijn, A. P.;
Conrad, J.;
D'Ambrosio, N.;
de Salas, P. F.;
Faverzani, M.;
Ferella, A.;
Ferri, E.;
Garcia-Abia, P.;
Gomez-Tejedor, G. Garcia;
Gariazzo, S.;
Gatti, F.;
Gentile, C.;
Giachero, A.;
Gudmundsson, J.;
Hochberg, Y.;
Kahn, Y.;
Lisanti, M.;
Mancini-Terracciano, C.;
Mangano, G.;
Marcucci, L. E.;
Mariani, C.;
Martinez, J.;
Messina, M.;
Molinero-Vela, A.;
Monticone, E.;
Nucciotti, A.;
Pandolfi, F.;
Pastor, S.;
Pedros, J.;
Heros, C. Perez de los;
Pisanti, O.;
Polosa, A.;
Puiu, A.;
Raitses, Y.;
Rajteri, M.;
Rossi, N.;
Santorelli, R.;
Schaeffner, K.;
Strid, C. F.;
Tully, C. G.;
Zhao, F.;
Zurek, K. M.
Submitted: 2018-10-15
We present a detailed description of the electromagnetic filter for the
PTOLEMY project to directly detect the Cosmic Neutrino Background (CNB).
Starting with an initial estimate for the orbital magnetic moment, the
higher-order drift process of ExB is configured to balance the gradient-B drift
motion of the electron in such a way as to guide the trajectory into the
standing voltage potential along the mid-plane of the filter. As a function of
drift distance along the length of the filter, the filter zooms in with
exponentially increasing precision on the transverse velocity component of the
electron kinetic energy. This yields a linear dimension for the total filter
length that is exceptionally compact compared to previous techniques for
electromagnetic filtering. The parallel velocity component of the electron
kinetic energy oscillates in an electrostatic harmonic trap as the electron
drifts along the length of the filter. An analysis of the phase-space volume
conservation validates the expected behavior of the filter from the adiabatic
invariance of the orbital magnetic moment and energy conservation following
Liouville's theorem for Hamiltonian systems.
[4]
oai:arXiv.org:1808.01892 [pdf] - 1728123
PTOLEMY: A Proposal for Thermal Relic Detection of Massive Neutrinos and
Directional Detection of MeV Dark Matter
Baracchini, E.;
Betti, M. G.;
Biasotti, M.;
Bosca, A.;
Calle, F.;
Carabe-Lopez, J.;
Cavoto, G.;
Chang, C.;
Cocco, A. G.;
Colijn, A. P.;
Conrad, J.;
D'Ambrosio, N.;
de Salas, P. F.;
Faverzani, M.;
Ferella, A.;
Ferri, E.;
Garcia-Abia, P.;
Gomez-Tejedor, G. Garcia;
Gariazzo, S.;
Gatti, F.;
Gentile, C.;
Giachero, A.;
Gudmundsson, J.;
Hochberg, Y.;
Kahn, Y.;
Lisanti, M.;
Mancini-Terracciano, C.;
Mangano, G.;
Marcucci, L. E.;
Mariani, C.;
Martinez, J.;
Mazzitelli, G.;
Messina, M.;
Molinero-Vela, A.;
Monticone, E.;
Nucciotti, A.;
Pandolfi, F.;
Pastor, S.;
Pedros, J.;
Heros, C. Perez de los;
Pisanti, O.;
Polosa, A.;
Puiu, A.;
Rajteri, M.;
Santorelli, R.;
Schaeffner, K.;
Tully, C. G.;
Raitses, Y.;
Rossi, N.;
Zhao, F.;
Zurek, K. M.
Submitted: 2018-08-06
We propose to achieve the proof-of-principle of the PTOLEMY project to
directly detect the Cosmic Neutrino Background (CNB). Each of the technological
challenges described in [1,2] will be targeted and hopefully solved by the use
of the latest experimental developments and profiting from the low background
environment provided by the LNGS underground site. The first phase will focus
on the graphene technology for a tritium target and the demonstration of TES
microcalorimetry with an energy resolution of better than 0.05 eV for low
energy electrons. These technologies will be evaluated using the PTOLEMY
prototype, proposed for underground installation, using precision HV controls
to step down the kinematic energy of endpoint electrons to match the
calorimeter dynamic range and rate capabilities. The second phase will produce
a novel implementation of the EM filter that is scalable to the full target
size and which demonstrates intrinsic triggering capability for selecting
endpoint electrons. Concurrent with the CNB program, we plan to exploit and
develop the unique properties of graphene to implement an intermediate program
for direct directional detection of MeV dark matter [3,4]. This program will
evaluate the radio-purity and scalability of the graphene fabrication process
with the goal of using recently identified ultra-high radio-purity CO2 sources.
The direct detection of the CNB is a snapshot of early universe dynamics
recorded by the thermal relic neutrino yield taken at a time that predates the
epochs of Big Bang Nucleosynthesis, the Cosmic Microwave Background and the
recession of galaxies (Hubble Expansion). Big Bang neutrinos are believed to
have a central role in the evolution of the Universe and a direct measurement
with PTOLEMY will unequivocally establish the extent to which these predictions
match present-day neutrino densities.