sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Betters, Christopher H.

Normalized to: Betters, C.

12 article(s) in total. 94 co-authors, from 1 to 10 common article(s). Median position in authors list is 3,0.

[1]  oai:arXiv.org:2003.05158  [pdf] - 2062914
An all-photonic focal-plane wavefront sensor
Comments:
Submitted: 2020-03-11
Adaptive optics (AO) is critical in modern astronomy, as well as in optical communications and remote sensing, to deal with the rapid blurring caused by the Earth's turbulent atmosphere. But even the best AO systems are limited by their wavefront sensors, which need to be in an optical plane non-common to the science image, unavoidably leading to errors that limit the reach of current astronomy. They are also insensitive to certain wavefront-error modes, and are poorly suited to injecting light into single-mode optical fibres, important for applications such as high-resolution spectroscopy of extra-solar planets. Here we present a new type of wavefront sensor based on a photonic lantern fibre-mode-converter and deep learning. This new wavefront sensor can be placed at the same focal plane as the science image, and is also optimal for single-mode fibre injection. By only measuring the intensities of an array of single-mode outputs, both phase and amplitude information on the incident wavefront can be reconstructed. We demonstrate the concept with both simulations and an experimental realisation of this novel wavefront sensor, wherein Zernike wavefront errors are recovered from focal-plane measurements to a precision of $2.6\times10^{-5}$ radians mean-squared-error.
[2]  oai:arXiv.org:2001.04046  [pdf] - 2034602
First demonstration of OH suppression in a high efficiency near-infrared spectrograph
Comments: Accepted for publication in MNRAS
Submitted: 2020-01-12
Ground-based near-infrared astronomy is severely hampered by the forest of atmospheric emission lines resulting from the rovibrational decay of OH molecules in the upper atmosphere. The extreme brightness of these lines, as well as their spatial and temporal variability, makes accurate sky subtraction difficult. Selectively filtering these lines with OH suppression instruments has been a long standing goal for near-infrared spectroscopy. We have shown previously the efficacy of fibre Bragg gratings combined with photonic lanterns for achieving OH suppression. Here we report on PRAXIS, a unique near-infrared spectrograph that is optimised for OH suppression with fibre Bragg gratings. We show for the first time that OH suppression (of any kind) is possible with high overall throughput (18 per cent end-to-end), and provide examples of the relative benefits of OH suppression.
[3]  oai:arXiv.org:1907.05904  [pdf] - 1916060
Astro2020: Astrophotonics White Paper
Comments: Astro2020 APC white paper, Submitted to the National Academy of Sciences for Astro2020 Decadal Survey, 9 pages (excluding references) and 3 figures
Submitted: 2019-07-12
Astrophotonics is the application of versatile photonic technologies to channel, manipulate, and disperse guided light from one or more telescopes to achieve scientific objectives in astronomy in an efficient and cost-effective way. The developments and demands from the telecommunication industry have driven a major boost in photonic technology and vice versa in the last 40 years. The photonic platform of guided light in fibers and waveguides has opened the doors to next-generation instrumentation for both ground- and space-based telescopes in optical and near/mid-IR bands, particularly for the upcoming extremely large telescopes (ELTs). The large telescopes are pushing the limits of adaptive optics to reach close to a near-diffraction-limited performance. The photonic devices are ideally suited for capturing this AO-corrected light and enabling new and exciting science such as characterizing exoplanet atmospheres. The purpose of this white paper is to summarize the current landscape of astrophotonic devices and their scientific impact, highlight the key issues, and outline specific technological and organizational approaches to address these issues in the coming decade and thereby enable new discoveries as we embark on the era of extremely large telescopes.
[4]  oai:arXiv.org:1804.05851  [pdf] - 1736348
Holistic spectroscopy: Complete reconstruction of a wide-field, multi-object spectroscopic image using a photonic comb
Comments: Submitted to MNRAS
Submitted: 2018-04-16
The primary goal of Galactic archaeology is to learn about the origin of the Milky Way from the detailed chemistry and kinematics of millions of stars. Wide-field multi-fibre spectrographs are increasingly used to obtain spectral information for huge samples of stars. Some surveys (e.g. GALAH) are attempting to measure up to 30 separate elements per star. Stellar abundance spectroscopy is a subtle art that requires a very high degree of spectral uniformity across each of the fibres. However wide-field spectrographs are notoriously non-uniform due to the fast output optics necessary to image many fibre outputs onto the detector. We show that precise spectroscopy is possible with such instruments across all fibres by employing a photonic comb -- a device that produces uniformly spaced spots of light on the CCD to precisely map complex aberrations. Aberrations are parametrized by a set of orthogonal moments with $\sim100$ independent parameters. We then reproduce the observed image by convolving high resolution spectral templates with measured aberrations as opposed to extracting the spectra from the observed image. Such a forward modeling approach also trivializes some spectroscopic reduction problems like fibre cross-talk, and reliably extracts spectra with a resolution $\sim2.3$ times above the nominal resolution of the instrument. Our rigorous treatment of optical aberrations also encourages a less conservative spectrograph design in the future.
[5]  oai:arXiv.org:1712.07762  [pdf] - 1607081
Developing post-coronagraphic, high-resolution spectroscopy for terrestrial planet characterization on ELTs
Comments: 11 pages, 3 figures, AO4ELTs4 conference held in Tenerife
Submitted: 2017-12-20, last modified: 2017-12-22
Spectroscopic observations are extremely important for determining the composition, structure, and surface gravity of exoplanetary atmospheres. High resolution spectroscopy of the planet itself has only been demonstrated a handful of times. By using advanced high contrast imagers, it is possible to conduct high resolution spectroscopy on imageable exoplanets, after the star light is first suppressed with an advanced coronagraph. Because the planet is spatially separated in the focal plane, a single mode fiber could be used to collect the light from the planet alone, reducing the photon noise by orders of magnitude. In addition, speckle control applied to the location where an exoplanet is known to exist, can be used to preferentially reject the stellar flux from the fiber further. In this paper we will present the plans for conducting high resolution spectroscopic studies of this nature with the combination of SCExAO and IRD in the H-band on the Subaru Telescope. This technique will be critical to the characterization of terrestrial planets on ELTs and future space missions.
[6]  oai:arXiv.org:1707.01847  [pdf] - 1585596
Demonstration of an efficient, photonic-based astronomical spectrograph on an 8-m telescope
Comments: 14 pages, 5 figures, Published in Optics Express
Submitted: 2017-07-06, last modified: 2017-08-26
We demonstrate for the first time an efficient, photonic-based astronomical spectrograph on the 8-m Subaru Telescope. An extreme adaptive optics system is combined with pupil apodiziation optics to efficiently inject light directly into a single-mode fiber, which feeds a compact cross-dispersed spectrograph based on array waveguide grating technology. The instrument currently offers a throughput of 5% from sky-to-detector which we outline could easily be upgraded to ~13% (assuming a coupling efficiency of 50%). The isolated spectrograph throughput from the single-mode fiber to detector was 42% at 1550 nm. The coupling efficiency into the single-mode fiber was limited by the achievable Strehl ratio on a given night. A coupling efficiency of 47% has been achieved with ~60% Strehl ratio on-sky to date. Improvements to the adaptive optics system will enable 90% Strehl ratio and a coupling of up to 67% eventually. This work demonstrates that the unique combination of advanced technologies enables the realization of a compact and highly efficient spectrograph, setting a precedent for future instrument design on very-large and extremely-large telescopes.
[7]  oai:arXiv.org:1704.08775  [pdf] - 1582941
Mapping the aberrations of a wide-field spectrograph using a photonic comb
Comments: Optics Express, Special Issue on Astrophotonics (10 pages, 6 figures)
Submitted: 2017-04-27
We demonstrate a new approach to calibrating the spectral-spatial response of a wide-field spectrograph using a fibre etalon comb. Conventional wide-field instruments employed on front-line telescopes are mapped with a grid of diffraction-limited holes cut into a focal plane mask. The aberrated grid pattern in the image plane typically reveals n-symmetric (e.g. pincushion) distortion patterns over the field arising from the optical train. This approach is impractical in the presence of a dispersing element because the diffraction-limited spots in the focal plane are imaged as an array of overlapping spectra. Instead we propose a compact solution that builds on recent developments in fibre-based Fabry-Perot etalons. We introduce a novel approach to near-field illumination that exploits a 25cm commercial telescope and the propagation of skew rays in a multimode fibre. The mapping of the optical transfer function across the full field is represented accurately (<0.5% rms residual) by an orthonormal set of Chebyshev moments. Thus we are able to reconstruct the full 4Kx4K CCD image of the dispersed output from the optical fibres using this mapping, as we demonstrate. Our method removes one of the largest sources of systematic error in multi-object spectroscopy.
[8]  oai:arXiv.org:1608.04391  [pdf] - 1461000
The GALAH survey: The data reduction pipeline
Comments:
Submitted: 2016-08-15
We present the data reduction procedures being used by the GALAH survey, carried out with the HERMES fibre-fed, multi-object spectrograph on the 3.9~m Anglo-Australian Telescope. GALAH is a unique survey, targeting 1 million stars brighter than magnitude V=14 at a resolution of 28,000 with a goal to measure the abundances of 29 elements. Such a large number of high resolution spectra necessitates the development of a reduction pipeline optimized for speed, accuracy, and consistency. We outline the design and structure of the Iraf-based reduction pipeline that we developed, specifically for GALAH, to produce fully calibrated spectra aimed for subsequent stellar atmospheric parameter estimation. The pipeline takes advantage of existing Iraf routines and other readily available software so as to be simple to maintain, testable and reliable. A radial velocity and stellar atmospheric parameter estimator code is also presented, which is used for further data analysis and yields a useful verification of the reduction quality. We have used this estimator to quantify the data quality of GALAH for fibre cross-talk level ($\lesssim0.5$%) and scattered light ($\sim5$ counts in a typical 20 minutes exposure), resolution across the field, sky spectrum properties, wavelength solution reliability (better than $1$ $\mathrm{km\ s^{-1}}$ accuracy) and radial velocity precision.
[9]  oai:arXiv.org:1310.4833  [pdf] - 737912
Beating the classical limit: A diffraction-limited spectrograph for an arbitrary input beam
Comments: 10 pages, 3 figures, accepted for publication in Opt. Express
Submitted: 2013-10-17
We demonstrate a new approach to classical fiber-fed spectroscopy. Our method is to use a photonic lantern that converts an arbitrary (e.g. incoherent) input beam into N diffraction-limited outputs. For the highest throughput, the number of outputs must be matched to the total number of unpolarized spatial modes on input. This approach has many advantages: (i) after the lantern, the instrument is constructed from 'commercial off the shelf' components; (ii) the instrument is the minimum size and mass configuration at a fixed resolving power and spectral order (~shoebox sized in this case); (iii) the throughput is better than 60% (slit to detector, including detector QE of ~80%); (iv) the scattered light at the detector can be less than 0.1% (total power). Our first implementation operates over 1545-1555 nm (limited by the detector, a 640$\times$512 array with 20$\mu$m pitch) with a spectral resolution of 0.055nm (R~30,000) using a 1$\times$7 (1 multi-mode input to 7 single-mode outputs) photonic lantern. This approach is a first step towards a fully integrated, multimode photonic microspectrograph.
[10]  oai:arXiv.org:1212.4867  [pdf] - 606379
Single mode, extreme precision Doppler spectrographs
Comments: IAU Proceedings, General Assembly 2012. 4 pages
Submitted: 2012-12-19
The 'holy grail' of exoplanet research today is the detection of an earth-like planet: a rocky planet in the habitable zone around a main-sequence star. Extremely precise Doppler spectroscopy is an indispensable tool to find and characterize earth-like planets; however, to find these planets around solar-type stars, we need nearly one order of magnitude better radial velocity (RV) precision than the best current spectrographs provide. Recent developments in astrophotonics (Bland-Hawthorn & Horton 2006, Bland-Hawthorn et al. 2010) and adaptive optics (AO) enable single mode fiber (SMF) fed, high resolution spectrographs, which can realize the next step in precision. SMF feeds have intrinsic advantages over multimode fiber or slit coupled spectrographs: The intensity distribution at the fiber exit is extremely stable, and as a result the line spread function of a well-designed spectrograph is fully decoupled from input coupling conditions, like guiding or seeing variations (Ihle et al. 2010). Modal noise, a limiting factor in current multimode fiber fed instruments (Baudrand & Walker 2001), can be eliminated by proper design, and the diffraction limited input to the spectrograph allows for very compact instrument designs, which provide excellent optomechanical stability. A SMF is the ideal interface for new, very precise wavelength calibrators, like laser frequency combs (Steinmetz et al. 2008, Osterman et al. 2012), or SMF based Fabry-Perot Etalons (Halverson et al. 2012). At near infrared wavelengths, these technologies are ready to be implemented in on-sky instruments, or already in use. We discuss a novel concept for such a spectrograph.
[11]  oai:arXiv.org:1208.4418  [pdf] - 552256
First starlight spectrum captured using an integrated photonic micro-spectrograph
Comments: 5 Pages, 4 Figures; A&A, Volume 544 (2012)
Submitted: 2012-08-21
Photonic technologies have received growing consideration for incorporation into next-generation astronomical instrumentation, owing to their miniature footprint and inherent robustness. In this paper we present results from the first on-telescope demonstration of a miniature photonic spectrograph for astronomy, by obtaining spectra spanning the entire H-band from several stellar targets. The prototype was tested on the 3.9 m Anglo-Australian telescope. In particular, we present a spectrum of the variable star Pi 01 Gru, with observed CO molecular absorption bands, at a resolving power R = 2500 at 1600 nm. Furthermore, we successfully demonstrate the simultaneous acquisition of multiple spectra with a single spectrograph chip by using multiple fibre inputs.
[12]  oai:arXiv.org:1208.3006  [pdf] - 1150687
The Photonic TIGER: a multicore fiber-fed spectrograph
Comments: 8 pages, 6 figures, SPIE Astronomical Telescopes and Instrumentation 8450-54
Submitted: 2012-08-14
We present a proof of concept compact diffraction limited high-resolution fiber-fed spectrograph by using a 2D multicore array input. This high resolution spectrograph is fed by a 2D pseudo-slit, the Photonic TIGER, a hexagonal array of near-diffraction limited single-mode cores. We study the feasibility of this new platform related to the core array separation and rotation with respect to the dispersion axis. A 7 core compact Photonic TIGER fiber-fed spectrograph with a resolving power of around R~31000 and 8 nm bandwidth in the IR centered on 1550 nm is demonstrated. We also describe possible architectures based on this concept for building small scale compact diffraction limited Integral Field Spectrographs (IFS).