sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Betancourt-Martinez, Gabriele

Normalized to: Betancourt-Martinez, G.

5 article(s) in total. 77 co-authors, from 1 to 4 common article(s). Median position in authors list is 1,0.

[1]  oai:arXiv.org:2003.13838  [pdf] - 2072810
High-Precision Determination of Oxygen-K$\alpha$ Transition Energy Excludes Incongruent Motion of Interstellar Oxygen
Comments: Submitted to PRL. 7 pages, 3 figures
Submitted: 2020-03-30
We demonstrate a widely applicable technique to absolutely calibrate the energy scale of x-ray spectra with experimentally well-known and accurately calculable transitions of highly charged ions, allowing us to measure the K-shell Rydberg spectrum of molecular O$_2$ with 6 meV uncertainty. We reveal a systematic $\sim$450 meV shift from previous literature values, and settle an extraordinary discrepancy between astrophysical and laboratory measurements of neutral atomic oxygen, the latter being calibrated against the aforementioned O$_2$ literature values. Because of the widespread use of such, now deprecated, references, our method impacts on many branches of x-ray absorption spectroscopy. Moreover, it potentially reduces absolute uncertainties there to below the meV level.
[2]  oai:arXiv.org:2003.04316  [pdf] - 2061812
Charge exchange, from the sky to the laboratory: A method to determine state-selective cross-sections for improved modeling
Comments: 6 pages, 6 figures
Submitted: 2020-03-09
Charge exchange (CX) is a semi-resonant recombination process that can lead to spectral line emission in the X-ray band. It occurs in nearly any environment where hot plasma and cold gas interact: in the solar system, in comets and planetary atmospheres, and likely astrophysically, in, for example, supernova remnants and galaxy clusters. It also contributes to the soft X-ray background. Accurate spectral modeling of CX is thus critical to properly interpreting our astrophysical observations, but the commonly used CX models in popular spectral fitting packages often rely on scaling equations and may not accurately describe observations or laboratory measurements. This paper introduces a method that can be applied to high-resolution CX spectra to directly extract state-selective CX cross-sections for electron capture, a key parameter for properly simulating the resulting CX spectrum.
[3]  oai:arXiv.org:1903.08213  [pdf] - 1853150
Unlocking the Capabilities of Future High-Resolution X-ray Spectroscopy Missions Through Laboratory Astrophysics
Comments: Science white paper submitted to the Astro2020 Decadal Survey
Submitted: 2019-03-19
Thanks to high-resolution and non-dispersive spectrometers onboard future X-ray missions such as XRISM and Athena, we are finally poised to answer important questions about the formation and evolution of galaxies and large-scale structure. However, we currently lack an adequate understanding of many atomic processes behind the spectral features we will soon observe. Large error bars on parameters as critical as transition energies and atomic cross sections can lead to unacceptable uncertainties in the calculations of e.g., elemental abundance, velocity, and temperature. Unless we address these issues, we risk limiting the full scientific potential of these missions. Laboratory astrophysics, which comprises theoretical and experimental studies of the underlying physics behind observable astrophysical processes, is therefore central to the success of these missions.
[4]  oai:arXiv.org:1811.12411  [pdf] - 1791807
High-resolution Charge Exchange Spectra with L-shell Nickel Show Striking Differences from Models
Comments: 14 pages, 4 figures, 1 table
Submitted: 2018-11-29
We present the first high-resolution laboratory spectra of X-ray emission following L-shell charge exchange between nickel ions and neutral H2 and He. We employ the commonly used charge exchange models found in XSPEC and SPEX, ACX and SPEX-CX, to simulate our experimental results. We show that significant differences between data and models exist in both line energies and strengths. In particular, we find that configuration mixing may play an important role in generating lines from core-excited states, and may be improperly treated in models. Our results indicate that if applied to astrophysical data, these models may lead to incorrect assumptions of the physical and chemical parameters of the region of interest.
[5]  oai:arXiv.org:1807.01582  [pdf] - 1710730
Testing the X-IFU calibration requirements: an example for quantum efficiency and energy resolution
Comments: 9 pages, 4 figures, SPIE proceeding Austin 2018
Submitted: 2018-07-04
With its array of 3840 Transition Edge Sensors (TESs) operated at 90 mK, the X-Ray Integral Field Unit (X-IFU) on board the ESA L2 mission Athena will provide spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) over the 0.2 to 12 keV bandpass. The in-flight performance of the X-IFU will be strongly affected by the calibration of the instrument. Uncertainties in the knowledge of the overall system, from the filter transmission to the energy scale, may introduce systematic errors in the data, which could potentially compromise science objectives - notably those involving line characterisation e.g. turbulence velocity measurements - if not properly accounted for. Defining and validating calibration requirements is therefore of paramount importance. In this paper, we put forward a simulation tool based on the most up-to-date configurations of the various subsystems (e.g. filters, detector absorbers) which allows us to estimate systematic errors related to uncertainties in the instrumental response. Notably, the effect of uncertainties in the energy resolution and of the instrumental quantum efficiency on X-IFU observations is assessed, by taking as a test case the measurements of the iron K complex in the hot gas surrounding clusters of galaxies. In-flight and ground calibration of the energy resolution and the quantum efficiency is also addressed. We demonstrate that provided an accurate calibration of the instrument, such effects should be low in both cases with respect to statistics during observations.