Normalized to: Bernal, E.
[1]
oai:arXiv.org:2005.07348 [pdf] - 2110068
The Near-Infrared Polarization of the Pre-Planetary Nebula Frosty Leo
Submitted: 2020-05-14
We present a near-infrared imaging polarimetric study of the pre-planetary
nebula: Frosty Leo. The observations were carried out in J, H and K' bands
using the new polarimeter POLICAN mounted on the 2.1m telescope of the
Guillermo Haro Astrophysical Observatory, Sonora, Mexico. The most prominent
result observed in the polarization maps is a large and well defined dusty
envelope (35\arcsec\ diameter in H-band). The polarization position angles in
the envelope are particularly well ordered and nearly parallel to the equator
of the nebula (seen in J and H bands). The nebula presents a known bipolar
outflow and the envelope completely wraps around it. Within the bipolar lobes,
we find high polarization levels ranging from $60\%$ (J band) to $90\%$ (K'
band) and the polarization angles trace a centrosymmetric pattern. We found the
remnants of superwind shells at the edges of the bipolar lobes and the duration
of this phase is around 600 yrs. The origin of polarization features in the
nebula is most likely due to a combination of single and multiple scattering.
Our results clearly demonstrate new structures that provide new hints on the
evolution of Frosty Leo from its previous asymptotic giant branch phase.
[2]
oai:arXiv.org:1803.02478 [pdf] - 1659749
POLICAN: A Near-infrared Imaging Polarimeter at the 2.1m OAGH Telescope
Submitted: 2018-03-06
POLICAN is a near-infrared imaging linear polarimeter developed for the
Cananea Near-infrared Camera (CANICA) at the 2.1m telescope of the Guillermo
Haro Astrophysical Observatory (OAGH) located in Cananea, Sonora, Mexico.
POLICAN is mounted ahead of CANICA and consist of a rotating super-achromatic
1-2.7 micron half-wave plate (HWP) as the modulator and a fixed wire-grid
polarizer as the analyzer. CANICA has a 1024 x 1024 HgCdTe detector with a
plate scale of 0.32 arcsec/pixel and provides a field of view of 5.5 x 5.5
arcmin^2. The polarimetric observations are carried out by modulating the
incoming light through different steps of half-wave plate angles 0, 22.5, 45,
67.5 deg, to establish linear Stokes parameters (I, Q, and U). Image reduction
consists of dark subtraction, polarimetric flat fielding, and sky subtraction.
The astrometry and photometric calibrations are performed using the publicly
available data from the Two Micron All Sky Survey. Polarimetric calibration
includes observations of globular clusters and polarization standards available
in the literature. Analysis of multiple observations of globular clusters
yielded an instrumental polarization of 0.51%. Uncertainties in polarization
range from 0.1% to 10% from the brightest 7 mag to faintest 16 mag stars. The
polarimetric accuracy achieved is better than 0.5% and the position angle
errors less than 5 deg for stars brighter than 13 mag in H-band. POLICAN is
mainly being used to study the scattered polarization and magnetic fields in
and around star-forming regions of the interstellar medium.