Normalized to: Benielli, D.
[1]
oai:arXiv.org:1502.05717 [pdf] - 1224510
Systematic characterisation of the Herschel SPIRE Fourier Transform
Spectrometer
Hopwood, R.;
Polehampton, E. T.;
Valtchanov, I.;
Swinyard, B. M.;
Fulton, T.;
Lu, N.;
Marchili, N.;
van der Wiel, M. H. D.;
Benielli, D.;
Imhof, P.;
Baluteau, J. -P.;
Pearson, C.;
Clements, D. L.;
Griffin, M. J.;
Lim, T. L.;
Makiwa, G.;
Naylor, D. A.;
Noble, G.;
Puga, E.;
Spencer, L. D.
Submitted: 2015-02-19
A systematic programme of calibration observations was carried out to monitor
the performance of the SPIRE FTS instrument on board the Herschel Space
Observatory. Observations of planets (including the prime point-source
calibrator, Uranus), asteroids, line sources, dark sky, and cross-calibration
sources were made in order to monitor repeatability and sensitivity, and to
improve FTS calibration. We present a complete analysis of the full set of
calibration observations and use them to assess the performance of the FTS.
Particular care is taken to understand and separate out the effect of pointing
uncertainties, including the position of the internal beam steering mirror for
sparse observations in the early part of the mission. The repeatability of
spectral line centre positions is <5km/s, for lines with signal-to-noise ratios
>40, corresponding to <0.5-2.0% of a resolution element. For spectral line
flux, the repeatability is better than 6%, which improves to 1-2% for spectra
corrected for pointing offsets. The continuum repeatability is 4.4% for the SLW
band and 13.6% for the SSW band, which reduces to ~1% once the data have been
corrected for pointing offsets. Observations of dark sky were used to assess
the sensitivity and the systematic offset in the continuum, both of which were
found to be consistent across the FTS detector arrays. The average point-source
calibrated sensitivity for the centre detectors is 0.20 and 0.21 Jy [1 sigma; 1
hour], for SLW and SSW. The average continuum offset is 0.40 Jy for the SLW
band and 0.28 Jy for the SSW band.
[2]
oai:arXiv.org:1403.1107 [pdf] - 1208191
Calibration of the Herschel SPIRE Fourier Transform Spectrometer
Swinyard, B. M.;
Polehampton, E. T.;
Hopwood, R.;
Valtchanov, I.;
Lu, N.;
Fulton, T.;
Benielli, D.;
Imhof, P.;
Marchili, N.;
Baluteau, J. -P.;
Bendo, G. J.;
Ferlet, M.;
Griffin, M. J.;
Lim, T. L.;
Makiwa, G.;
Naylor, D. A.;
Orton, G. S.;
Papageorgiou, A.;
Pearson, C. P.;
Schulz, B.;
Sidher, S. D.;
Spencer, L. D.;
van der Wiel, M. H. D.;
Wu, R.
Submitted: 2014-03-05
The Herschel SPIRE instrument consists of an imaging photometric camera and
an imaging Fourier Transform Spectrometer (FTS), both operating over a
frequency range of 450-1550 GHz. In this paper, we briefly review the FTS
design, operation, and data reduction, and describe in detail the approach
taken to relative calibration (removal of instrument signatures) and absolute
calibration against standard astronomical sources. The calibration scheme
assumes a spatially extended source and uses the Herschel telescope as primary
calibrator. Conversion from extended to point-source calibration is carried out
using observations of the planet Uranus. The model of the telescope emission is
shown to be accurate to within 6% and repeatable to better than 0.06% and, by
comparison with models of Mars and Neptune, the Uranus model is shown to be
accurate to within 3%. Multiple observations of a number of point-like sources
show that the repeatability of the calibration is better than 1%, if the
effects of the satellite absolute pointing error (APE) are corrected. The
satellite APE leads to a decrement in the derived flux, which can be up to ~10%
(1 sigma) at the high-frequency end of the SPIRE range in the first part of the
mission, and ~4% after Herschel operational day 1011. The lower frequency range
of the SPIRE band is unaffected by this pointing error due to the larger beam
size. Overall, for well-pointed, point-like sources, the absolute flux
calibration is better than 6%, and for extended sources where mapping is
required it is better than 7%.
[3]
oai:arXiv.org:1401.2049 [pdf] - 1202650
Herschel SPIRE FTS Relative Spectral Response Calibration
Fulton, Trevor;
Hopwood, Rosalind;
Baluteau, Jean-Paul;
Benielli, Dominique;
Imhof, Peter;
Lim, Tanya;
Lu, Nanyao;
Marchili, Nicola;
Naylor, David;
Polehampton, Edward;
Swinyard, Bruce;
Valtchanov, Ivan
Submitted: 2014-01-09
Herschel/SPIRE Fourier transform spectrometer (FTS) observations contain
emission from both the Herschel Telescope and the SPIRE Instrument itself, both
of which are typically orders of magnitude greater than the emission from the
astronomical source, and must be removed in order to recover the source
spectrum. The effects of the Herschel Telescope and the SPIRE Instrument are
removed during data reduction using relative spectral response calibration
curves and emission models. We present the evolution of the methods used to
derive the relative spectral response calibration curves for the SPIRE FTS. The
relationship between the calibration curves and the ultimate sensitivity of
calibrated SPIRE FTS data is discussed and the results from the derivation
methods are compared. These comparisons show that the latest derivation methods
result in calibration curves that impart a factor of between 2 and 100 less
noise to the overall error budget, which results in calibrated spectra for
individual observations whose noise is reduced by a factor of 2-3, with a gain
in the overall spectral sensitivity of 23% and 21% for the two detector bands,
respectively.
[4]
oai:arXiv.org:1401.2043 [pdf] - 769842
Relative pointing offset analysis of calibration targets with repeated
observations with Herschel-SPIRE Fourier-Transform Spectrometer
Valtchanov, Ivan;
Hopwood, Rosalind;
Polehampton, Edward;
Benielli, Dominique;
Fulton, Trevor;
Imhof, Peter;
Konopczynski, Tomasz;
Lim, Tanya;
Lu, Nanyao;
Marchili, Nicola;
Naylor, David;
Swinyard, Bruce
Submitted: 2014-01-09
We present a method to derive the relative pointing offsets for SPIRE
Fourier-Transform Spectrometer (FTS) solar system object (SSO) calibration
targets, which were observed regularly throughout the Herschel mission. We
construct ratios of the spectra for all observations of a given source with
respect to a reference. The reference observation is selected iteratively to be
the one with the highest observed continuum. Assuming that any pointing offset
leads to an overall shift of the continuum level, then these ratios represent
the relative flux loss due to mispointing. The mispointing effects are more
pronounced for a smaller beam, so we consider only the FTS short wavelength
array (SSW, 958-1546 GHz) to derive a pointing correction. We obtain the
relative pointing offset by comparing the ratio to a grid of expected losses
for a model source at different distances from the centre of the beam, under
the assumption that the SSW FTS beam can be well approximated by a Gaussian. In
order to avoid dependency on the point source flux conversion, which uses a
particular observation of Uranus, we use extended source flux calibrated
spectra to construct the ratios for the SSOs. In order to account for continuum
variability, due to the changing distance from the Herschel telescope, the SSO
ratios are normalised by the expected model ratios for the corresponding
observing epoch. We confirm the accuracy of the derived pointing offset by
comparing the results with a number of control observations, where the actual
pointing of Herschel is known with good precision. Using the method we derived
pointing offsets for repeated observations of Uranus (including observations
centred on off-axis detectors), Neptune, Ceres and NGC7027. The results are
used to validate and improve the point-source flux calibration of the FTS.
[5]
oai:arXiv.org:1401.2047 [pdf] - 769844
Herschel SPIRE FTS telescope model correction
Hopwood, Rosalind;
Fulton, Trevor;
Polehampton, Edward T.;
Valtchanov, Ivan;
Benielli, Dominique;
Imhof, Peter;
Lim, Tanya;
Lu, Nanyao;
Marchili, Nicola;
Pearson, Chris P.;
Swinyard, Bruce M.
Submitted: 2014-01-09
Emission from the Herschel telescope is the dominant source of radiation for
the majority of SPIRE Fourier transform spectrometer (FTS) observations,
despite the exceptionally low emissivity of the primary and secondary mirrors.
Accurate modelling and removal of the telescope contribution is, therefore, an
important and challenging aspect of FTS calibration and data reduction
pipeline. A dust-contaminated telescope model with time invariant mirror
emissivity was adopted before the Herschel launch. However, measured FTS
spectra show a clear evolution of the telescope contribution over the mission
and strong need for a correction to the standard telescope model in order to
reduce residual background (of up to 7 Jy) in the final data products.
Systematic changes in observations of dark sky, taken over the course of the
mission, provide a measure of the evolution between observed telescope emission
and the telescope model. These dark sky observations have been used to derive a
time dependent correction to the telescope emissivity that reduces the
systematic error in the continuum of the final FTS spectra to ~0.35 Jy.
[6]
oai:arXiv.org:1401.2045 [pdf] - 769843
Herschel SPIRE Fourier Transform Spectrometer: Calibration of its
Bright-source Mode
Lu, Nanyao;
Polehampton, Edward T.;
Swinyard, Bruce M.;
Benielli, Dominique;
Fulton, Trevor;
Hopwood, Rosalind;
Imhof, Peter;
Lim, Tanya;
Marchili, Nicola;
Naylor, David A.;
Schulz, Bernhard;
Sidher, Sunil;
Valtchanov, Ivan
Submitted: 2014-01-09
The Fourier Transform Spectrometer (FTS) of the Spectral and Photometric
Imaging REceiver (SPIRE) on board the ESA Herschel Space Observatory has two
detector setting modes: (a) a nominal mode, which is optimized for observing
moderately bright to faint astronomical targets, and (b) a bright-source mode
recommended for sources significantly brighter than 500 Jy, within the SPIRE
FTS bandwidth of 446.7-1544 GHz (or 194-671 microns in wavelength), which
employs a reduced detector responsivity and out-of-phase analog signal
amplifier/demodulator. We address in detail the calibration issues unique to
the bright-source mode, describe the integration of the bright-mode data
processing into the existing pipeline for the nominal mode, and show that the
flux calibration accuracy of the bright-source mode is generally within 2% of
that of the nominal mode, and that the bright-source mode is 3 to 4 times less
sensitive than the nominal mode.
[7]
oai:arXiv.org:1401.2040 [pdf] - 1202649
Herschel SPIRE FTS Spectral Mapping Calibration
Benielli, Dominique;
Polehampton, Edward;
Hopwood, Rosalind;
Marín, Ana Belén Griñón;
Fulton, Trevor;
Imhof, Peter;
Lim, Tanya;
Lu, Nanyao;
Makiwa, Gibion;
Marchili, Nicola;
Naylor, David;
Spencer, Locke;
Swinyard, Bruce;
Valtchanov, Ivan;
van der Wiel, Matthijs
Submitted: 2014-01-09
The Herschel SPIRE Fourier transform spectrometer (FTS) performs spectral
imaging in the 447-1546 GHz band. It can observe in three spatial sampling
modes: sparse mode, with a single pointing on sky, or intermediate or full
modes with 1 and 1/2 beam spacing, respectively. In this paper, we investigate
the uncertainty and repeatability for fully sampled FTS mapping observations.
The repeatability is characterised using nine observations of the Orion Bar.
Metrics are derived based on the ratio of the measured intensity in each
observation compared to that in the combined spectral cube from all
observations. The mean relative deviation is determined to be within 2%, and
the pixel-by-pixel scatter is ~7%. The scatter increases towards the edges of
the maps. The uncertainty in the frequency scale is also studied, and the
spread in the line centre velocity across the maps is found to be ~15 km/s.
Other causes of uncertainty are also discussed including the effect of pointing
and the additive uncertainty in the continuum.
[8]
oai:arXiv.org:1306.5780 [pdf] - 1172267
Observing Extended Sources with the \Herschel SPIRE Fourier Transform
Spectrometer
Wu, Ronin;
Polehampton, Edward T.;
Etxaluze, Mireya;
Makiwa, Gibion;
Naylor, David A.;
Salji, Carl;
Swinyard, Bruce M.;
Ferlet, Marc;
van der Wiel, Matthijs H. D.;
Smith, Anthony J.;
Fulton, Trevor;
Griffin, Matt J.;
Baluteau, Jean-Paul;
Benielli, Dominique;
Glenn, Jason;
Hopwood, Rosalind;
Imhof, Peter;
Lim, Tanya;
Lu, Nanyao;
Panuzzo, Pasquale;
Pearson, Chris;
Sidher, Sunil;
Valtchanov, Ivan
Submitted: 2013-06-24
The Spectral and Photometric Imaging Receiver (SPIRE) on the European Space
Agency's Herschel Space Observatory utilizes a pioneering design for its
imaging spectrometer in the form of a Fourier Transform Spectrometer (FTS). The
standard FTS data reduction and calibration schemes are aimed at objects with
either a spatial extent much larger than the beam size or a source that can be
approximated as a point source within the beam. However, when sources are of
intermediate spatial extent, neither of these calibrations schemes is
appropriate and both the spatial response of the instrument and the source's
light profile must be taken into account and the coupling between them
explicitly derived. To that end, we derive the necessary corrections using an
observed spectrum of a fully extended source with the beam profile and the
source's light profile taken into account. We apply the derived correction to
several observations of planets and compare the corrected spectra with their
spectral models to study the beam coupling efficiency of the instrument in the
case of partially extended sources. We find that we can apply these correction
factors for sources with angular sizes up to \theta_{D} ~ 17". We demonstrate
how the angular size of an extended source can be estimated using the
difference between the sub-spectra observed at the overlap bandwidth of the two
frequency channels in the spectrometer, at 959<\nu<989 GHz. Using this
technique on an observation of Saturn, we estimate a size of 17.2", which is 3%
larger than its true size on the day of observation. Finally, we show the
results of the correction applied on observations of a nearby galaxy, M82, and
the compact core of a Galactic molecular cloud, Sgr B2.
[9]
oai:arXiv.org:1005.5073 [pdf] - 1032794
In-flight calibration of the Herschel-SPIRE instrument
Swinyard, B. M.;
Ade, P.;
Baluteau, J-P.;
Aussel, H.;
Barlow, M. J.;
Bendo, G. J.;
Benielli, D.;
Bock, J.;
Brisbin, D.;
Conley, A.;
Conversi, L.;
Dowell, A.;
Dowell, D.;
Ferlet, M.;
Fulton, T.;
Glenn, J.;
Glauser, A.;
Griffin, D.;
Griffin, M.;
Guest, S.;
Imhof, P.;
Isaak, K.;
Jones, S.;
King, K.;
Leeks, S.;
Levenson, L.;
Lim, T. L.;
Lu, N.;
Makiwa, G.;
Naylor, D.;
Nguyen, H.;
Oliver, S.;
Panuzzo, P.;
Papageorgiou, A.;
Pearson, C.;
Pohlen, M.;
Polehampton, E.;
Pouliquen, D.;
Rigopoulou, D.;
Ronayette, S.;
Roussel, H.;
Rykala, A.;
Savini, G.;
Schulz, B.;
Schwartz, A.;
Shupe, D.;
Sibthorpe, B.;
Sidher, S.;
Smith, A. J.;
Spencer, L.;
Trichas, M.;
Triou, H.;
Valtchanov, I.;
Wesson, R.;
Woodcraft, A.;
Xu, C. K.;
Zemcov, M.;
Zhang, L.
Submitted: 2010-05-27
SPIRE, the Spectral and Photometric Imaging Receiver, is the Herschel Space
Observatory's submillimetre camera and spectrometer. It contains a three-band
imaging photometer operating at 250, 350 and 500 {\mu}m, and an imaging Fourier
transform spectrometer (FTS) covering 194-671 {\mu}m (447-1550 GHz). In this
paper we describe the initial approach taken to the absolute calibration of the
SPIRE instrument using a combination of the emission from the Herschel
telescope itself and the modelled continuum emission from solar system objects
and other astronomical targets. We present the photometric, spectroscopic and
spatial accuracy that is obtainable in data processed through the "standard"
pipelines. The overall photometric accuracy at this stage of the mission is
estimated as 15% for the photometer and between 15 and 50% for the
spectrometer. However, there remain issues with the photometric accuracy of the
spectra of low flux sources in the longest wavelength part of the SPIRE
spectrometer band. The spectrometer wavelength accuracy is determined to be
better than 1/10th of the line FWHM. The astrometric accuracy in SPIRE maps is
found to be 2 arcsec when the latest calibration data are used. The photometric
calibration of the SPIRE instrument is currently determined by a combination of
uncertainties in the model spectra of the astronomical standards and the data
processing methods employed for map and spectrum calibration. Improvements in
processing techniques and a better understanding of the instrument performance
will lead to the final calibration accuracy of SPIRE being determined only by
uncertainties in the models of astronomical standards.
[10]
oai:arXiv.org:1005.5123 [pdf] - 1032799
The Herschel-SPIRE instrument and its in-flight performance
Griffin, M. J.;
Abergel, A.;
Abreu, A.;
Ade, P. A. R.;
André, P.;
Augueres, J. -L.;
Babbedge, T.;
Bae, Y.;
Baillie, T.;
Baluteau, J. -P.;
Barlow, M. J.;
Bendo, G.;
Benielli, D.;
Bock, J. J.;
Bonhomme, P.;
Brisbin, D.;
Brockley-Blatt, C.;
Caldwell, M.;
Cara, C.;
Castro-Rodriguez, N.;
Cerulli, R.;
Chanial, P.;
Chen, S.;
Clark, E.;
Clements, D. L.;
Clerc, L.;
Coker, J.;
Communal, D.;
Conversi, L.;
Cox, P.;
Crumb, D.;
Cunningham, C.;
Daly, F.;
Davis, G. R.;
De Antoni, P.;
Delderfield, J.;
Devin, N.;
Di Giorgio, A.;
Didschuns, I.;
Dohlen, K.;
Donati, M.;
Dowell, A.;
Dowell, C. D.;
Duband, L.;
Dumaye, L.;
Emery, R. J.;
Ferlet, M.;
Ferrand, D.;
Fontignie, J.;
Fox, M.;
Franceschini, A.;
Frerking, M.;
Fulton, T.;
Garcia, J.;
Gastaud, R.;
Gear, W. K.;
Glenn, J.;
Goizel, A.;
Griffin, D. K.;
Grundy, T.;
Guest, S.;
Guillemet, L.;
Hargrave, P. C.;
Harwit, M.;
Hastings, P.;
Hatziminaoglou, E.;
Herman, M.;
Hinde, B.;
Hristov, V.;
Huang, M.;
Imhof, P.;
Isaak, K. J.;
Israelsson, U.;
Ivison, R. J.;
Jennings, D.;
Kiernan, B.;
King, K. J.;
Lange, A. E.;
Latter, W.;
Laurent, G.;
Laurent, P.;
Leeks, S. J.;
Lellouch, E.;
Levenson, L.;
Li, B.;
Li, J.;
Lilienthal, J.;
Lim, T.;
Liu, J.;
Lu, N.;
Madden, S.;
Mainetti, G.;
Marliani, P.;
McKay, D.;
Mercier, K.;
Molinari, S.;
Morris, H.;
Moseley, H.;
Mulder, J.;
Mur, M.;
Naylor, D. A.;
Nguyen, H.;
O'Halloran, B.;
Oliver, S.;
Olofsson, G.;
Olofsson, H. -G.;
Orfei, R.;
Page, M. J.;
Pain, I.;
Panuzzo, P.;
Papageorgiou, A.;
Parks, G.;
Parr-Burman, P.;
Pearce, A.;
Pearson, C.;
Pérez-Fournon, I.;
Pinsard, F.;
Pisano, G.;
Podosek, J.;
Pohlen, M.;
Polehampton, E. T.;
Pouliquen, D.;
Rigopoulou, D.;
Rizzo, D.;
Roseboom, I. G.;
Roussel, H.;
Rowan-Robinson, M.;
Rownd, B.;
Saraceno, P.;
Sauvage, M.;
Savage, R.;
Savini, G.;
Sawyer, E.;
Scharmberg, C.;
Schmitt, D.;
Schneider, N.;
Schulz, B.;
Schwartz, A.;
Shafer, R.;
Shupe, D. L.;
Sibthorpe, B.;
Sidher, S.;
Smith, A.;
Smith, A. J.;
Smith, D.;
Spencer, L.;
Stobie, B.;
Sudiwala, R.;
Sukhatme, K.;
Surace, C.;
Stevens, J. A.;
Swinyard, B. M.;
Trichas, M.;
Tourette, T.;
Triou, H.;
Tseng, S.;
Tucker, C.;
Turner, A.;
Vaccari, M.;
Valtchanov, I.;
Vigroux, L.;
Virique, E.;
Voellmer, G.;
Walker, H.;
Ward, R.;
Waskett, T.;
Weilert, M.;
Wesson, R.;
White, G. J.;
Whitehouse, N.;
Wilson, C. D.;
Winter, B.;
Woodcraft, A. L.;
Wright, G. S.;
Xu, C. K.;
Zavagno, A.;
Zemcov, M.;
Zhang, L.;
Zonca, E.
Submitted: 2010-05-27
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space
Observatory`s submillimetre camera and spectrometer. It contains a three-band
imaging photometer operating at 250, 350 and 500 microns, and an imaging
Fourier Transform Spectrometer (FTS) which covers simultaneously its whole
operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are
arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a
field of view of 4' x 8', observed simultaneously in the three spectral bands.
Its main operating mode is scan-mapping, whereby the field of view is scanned
across the sky to achieve full spatial sampling and to cover large areas if
desired. The spectrometer has an approximately circular field of view with a
diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25
GHz by changing the stroke length of the FTS scan mirror. Its main operating
mode involves a fixed telescope pointing with multiple scans of the FTS mirror
to acquire spectral data. For extended source measurements, multiple position
offsets are implemented by means of an internal beam steering mirror to achieve
the desired spatial sampling and by rastering of the telescope pointing to map
areas larger than the field of view. The SPIRE instrument consists of a cold
focal plane unit located inside the Herschel cryostat and warm electronics
units, located on the spacecraft Service Module, for instrument control and
data handling. Science data are transmitted to Earth with no on-board data
compression, and processed by automatic pipelines to produce calibrated science
products. The in-flight performance of the instrument matches or exceeds
predictions based on pre-launch testing and modelling: the photometer
sensitivity is comparable to or slightly better than estimated pre-launch, and
the spectrometer sensitivity is also better by a factor of 1.5-2.