Normalized to: Beheshtipour, B.
[1]
oai:arXiv.org:2001.03116 [pdf] - 2061651
Deep learning for clustering of continuous gravitational wave candidates
Submitted: 2020-01-09, last modified: 2020-01-14
In searching for continuous gravitational waves over very many ($\approx
10^{17}$) templates , clustering is a powerful tool which increases the search
sensitivity by identifying and bundling together candidates that are due to the
same root cause. We implement a deep learning network that identifies clusters
of signal candidates in the output of continuous gravitational wave searches
and assess its performance. For loud signals our network achieves a detection
efficiency higher than 97\% with a very low false alarm rate, and maintains a
reasonable detection efficiency for signals with lower amplitudes, i.e. at
$\lesssim$ current upper limit values.
[2]
oai:arXiv.org:2001.03581 [pdf] - 2061653
Observations of a GX 301-2 Apastron Flare with the X-Calibur Hard X-Ray
Polarimeter Supported by NICER, the Swift XRT and BAT, and Fermi GBM
Abarr, Q.;
Baring, M.;
Beheshtipour, B.;
Beilicke, M.;
deGeronimo, G.;
Dowkontt, P.;
Errando, M.;
Guarino, V.;
Iyer, N.;
Kislat, F.;
Kiss, M.;
Kitaguchi, T.;
Krawczynski, H.;
Lanzi, J.;
Li, S.;
Lisalda, L.;
Okajima, T.;
Pearce, M.;
Press, L.;
Rauch, B.;
Stuchlik, D.;
Takahashi, H.;
Tang, J.;
Uchida, N.;
West, A.;
Jenke, P.;
Krimm, H.;
Lien, A.;
Malacaria, C.;
Miller, J. M.;
Wilson-Hodge, C.
Submitted: 2020-01-10
The accretion-powered X-ray pulsar GX 301-2 was observed with the
balloon-borne X-Calibur hard X-ray polarimeter during late December 2018, with
contiguous observations by the NICER X-ray telescope, the Swift X-ray Telescope
and Burst Alert Telescope, and the Fermi Gamma-ray Burst Monitor spanning
several months. The observations detected the pulsar in a rare apastron flaring
state coinciding with a significant spin-up of the pulsar discovered with the
Fermi GBM. The X-Calibur, NICER, and Swift observations reveal a pulse profile
strongly dominated by one main peak, and the NICER and Swift data show strong
variation of the profile from pulse to pulse. The X-Calibur observations
constrain for the first time the linear polarization of the 15-35 keV emission
from a highly magnetized accreting neutron star, indicating a polarization
degree of (27+38-27)% (90% confidence limit) averaged over all pulse phases. We
discuss the spin-up and the X-ray spectral and polarimetric results in the
context of theoretical predictions. We conclude with a discussion of the
scientific potential of future observations of highly magnetized neutron stars
with the more sensitive follow-up mission XL-Calibur.
[3]
oai:arXiv.org:1710.00247 [pdf] - 1593663
The X-ray Polarization of the Accretion Disk Coronae of Active Galactic
Nuclei
Submitted: 2017-09-30, last modified: 2017-10-29
Hard X-rays observed in Active Galactic Nuclei (AGNs) are thought to
originate from the Comptonization of the optical/UV accretion disk photons in a
hot corona. Polarization studies of these photons can help to constrain the
corona geometry and the plasma properties. We have developed a ray-tracing code
that simulates the Comptonization of accretion disk photons in coronae of
arbitrary shape, and use it here to study the polarization of the X-ray
emission from wedge and spherical coronae. We study the predicted polarization
signatures for the fully relativistic and various approximate treatments of the
elemental Compton scattering processes. We furthermore use the code to evaluate
the impact of non-thermal electrons and cyclo-synchrotron photons on the
polarization properties. Finally, we model the NuSTAR observations of the
Seyfert I galaxy Mrk 335 and predict the associated polarization signal. Our
studies show that X-ray polarimetry missions such as NASA's Imaging X-ray
Polarimetry Explorer (IXPE) and the X-ray Imaging Polarimetry Explorer (XIPE)
proposed to ESA will provide valuable new information about the physical
properties of the plasma close to the event horizon of AGN black holes.
[4]
oai:arXiv.org:1709.06412 [pdf] - 1588549
On the Calculation of the Fe K-alpha Line Emissivity of Black Hole
Accretion Disks
Submitted: 2017-09-19
Observations of the fluorescent Fe K-alpha emission line from the inner
accretion flows of stellar mass black holes in X-ray binaries and supermassive
black holes in Active Galactic Nuclei have become an important tool to study
the magnitude and inclination of the black hole spin, and the structure of the
accretion flow close to the event horizon of the black hole. Modeling spectral,
timing, and soon also X-ray polarimetric observations of the Fe K-alpha
emission requires to calculate the specific intensity in the rest frame of the
emitting plasma. We revisit the derivation of the equation used for calculating
the illumination of the accretion disk by the corona. We present an alternative
derivation leading to a simpler equation, and discuss the relation to the
previously published results.
[5]
oai:arXiv.org:1701.04536 [pdf] - 1534638
Design of the telescope truss and gondola for the balloon-borne X-ray
polarimeter X-Calibur
Kislat, Fabian;
Beheshtipour, Banafsheh;
Dowkontt, Paul;
Guarino, Victor;
Lanzi, R. James;
Okajima, Takashi;
Braun, Dana;
Cannon, Scott;
De Geronimo, Gialuigi;
Heatwole, Scott;
Hoorman, Janie;
Li, Shaorui;
Mori, Hideyuki;
Shreves, Christopher M.;
Stuchlik, David;
Krawczynski, Henric
Submitted: 2017-01-17
X-ray polarimetry has seen a growing interest in recent years. Improvements
in detector technology and focusing X-ray optics now enable sensitive
astrophysical X-ray polarization measurements. These measurements will provide
new insights into the processes at work in accreting black holes, the emission
of X-rays from neutron stars and magnetars, and the structure of AGN jets.
X-Calibur is a balloon-borne hard X-ray scattering polarimeter. An X-ray mirror
with a focal length of 8 m focuses X-rays onto the detector, which consists of
a plastic scattering element surrounded by Cadmium-Zinc-Telluride detectors,
which absorb and record the scattered X-rays. Since X-rays preferentially
scatter perpendicular to their polarization direction, the polarization
properties of an X-ray beam can be inferred from the azimuthal distribution of
scattered X-rays. A close alignment of the X-ray focal spot with the center of
the detector is required in order to reduce systematic uncertainties and to
maintain a high photon detection efficiency. This places stringent requirements
on the mechanical and thermal stability of the telescope structure. During the
flight on a stratospheric balloon, X-Calibur makes use of the Wallops
Arc-Second Pointer (WASP) to point the telescope at astrophysical sources. In
this paper, we describe the design, construction, and test of the telescope
structure, as well as its performance during a 25-hour flight from Ft. Sumner,
New Mexico. The carbon fiber-aluminum composite structure met the requirements
set by X-Calibur and its design can easily be adapted for other types of
experiments, such as X-ray imaging or spectroscopic telescopes.
[6]
oai:arXiv.org:1605.09756 [pdf] - 1457357
Studies of the Origin of High-Frequency Quasi-Periodic Oscillations of
Mass Accreting Black Holes in X-ray Binaries with Next-Generation X-ray
Telescopes
Submitted: 2016-05-31
Observations with RXTE (Rossi X-ray Timing Explorer) revealed the presence of
High Frequency Quasi-Periodic Oscillations (HFQPOs) of the X-ray flux from
several accreting stellar mass Black Holes. HFQPOs (and their counterparts at
lower frequencies) may allow us to study general relativity in the strong
gravity regime. However, the observational evidence today does not yet allow us
to distinguish between different HFQPO models. In this paper we use a general
relativistic ray-tracing code to investigate X-ray timing-spectroscopy and
polarization properties of HFQPOs in the orbiting Hotspot model. We study
observational signatures for the particular case of the 166 Hz quasi-periodic
oscillation (QPO) in the galactic binary GRS 1915+105. We conclude with a
discussion of the observability of spectral signatures with a
timing-spectroscopy experiment like the LOFT (Large Observatory for X-ray
Timing) and polarization signatures with space-borne X-ray polarimeters such as
IXPE (Imaging X-ray Polarimetry Explorer), PolSTAR (Polarization Spectroscopic
Telescope Array), PRAXyS (Polarimetry of Relativistic X-ray Sources), or XIPE
(X-ray Imaging Polarimetry Explorer). A high count-rate mission like LOFT would
make it possible to get a QPO phase for each photon, enabling the study of the
QPO-phase-resolved spectral shape and the correlation between this and the flux
level. Owing to the short periods of the HFQPOs, first-generation X-ray
polarimeters would not be able to assign a QPO phase to each photon. The study
of QPO-phase-resolved polarization energy spectra would thus require
simultaneous observations with a first-generation X-ray polarimeter and a
LOFT-type mission.
[7]
oai:arXiv.org:1601.02055 [pdf] - 1378787
Testing General Relativity's No-Hair Theorem with X-Ray Observations of
Black Holes
Submitted: 2016-01-08
Despite its success in the weak gravity regime, General Relativity (GR) has
yet to be verified in the regime of strong gravity. In this paper, we present
the results of detailed ray tracing simulations aiming at clarifying if the
combined information from X-ray spectroscopy, timing, and polarization
observations of stellar mass and supermassive black holes can be used to test
GR's no-hair theorem. The latter states that stationary astrophysical black
holes are described by the Kerr-family of metrics with the black hole mass and
spin being the only free parameters. We use four "non-Kerr metrics", some
phenomenological in nature and others motivated by alternative theories of
gravity, and study the observational signatures of deviations from the Kerr
metric. Particular attention is given to the case when all the metrics are set
to give the same Innermost Stable Circular Orbit (ISCO) in quasi-Boyer
Lindquist coordinates. We give a detailed discussion of similarities and
differences of the observational signatures predicted for BHs in the Kerr
metric and the non-Kerr metrics. We emphasize that even though some regions of
the parameter space are nearly degenerate even when combining the information
from all observational channels, X-ray observations of very rapidly spinning
black holes can be used to exclude large regions of the parameter space of the
alternative metrics. Although it proves difficult to distinguish between the
Kerr and non-Kerr metrics for some portions of the parameter space, the
observations of very rapidly spinning black holes like Cyg X-1 can be used to
rule out large regions for several black hole metrics.
[8]
oai:arXiv.org:1510.08358 [pdf] - 1335481
X-Ray Polarimetry with the Polarization Spectroscopic Telescope Array
(PolSTAR)
Krawczynski, Henric S.;
Stern, Daniel;
Harrison, Fiona A.;
Kislat, Fabian F.;
Zajczyk, Anna;
Beilicke, Matthias;
Hoormann, Janie;
Guo, Qingzhen;
Endsley, Ryan;
Ingram, Adam R.;
Miyasaka, Hiromasa;
Madsen, Kristin K.;
Aaron, Kim M.;
Aminia, Rashied;
Baring, Matthew G.;
Beheshtipour, Banafsheh;
Bodaghee, Arash;
Booth, Jeffrey;
Borden, Chester;
Boettcher, Markus;
Christensen, Finn E.;
Coppi, Paolo S.;
Cowsik, Ramanath;
Davis, Shane;
Dexter, Jason;
Done, Chris;
Dominguez, Luis A.;
Ellison, Don;
English, Robin J.;
Fabian, Andrew C.;
Falcone, Abe;
Favretto, Jeffrey A.;
Fernandez, Rodrigo;
Giommi, Paolo;
Grefenstette, Brian W.;
Kara, Erin;
Lee, Chung H.;
Lyutikov, Maxim;
Maccarone, Thomas;
Matsumoto, Hironori;
McKinney, Jonathan;
Mihara, Tatehiro;
Miller, Jon M.;
Narayan, Ramesh;
Natalucci, Lorenzo;
Oezel, Feryal;
Pivovaroff, Michael J.;
Pravdo, Steven;
Psaltis, Dimitrios;
Okajima, Takashi;
Toma, Kenji;
Zhang, William W.
Submitted: 2015-10-28
This paper describes the Polarization Spectroscopic Telescope Array
(PolSTAR), a mission proposed to NASA's 2014 Small Explorer (SMEX) announcement
of opportunity. PolSTAR measures the linear polarization of 3-50 keV
(requirement; goal: 2.5-70 keV) X-rays probing the behavior of matter,
radiation and the very fabric of spacetime under the extreme conditions close
to the event horizons of black holes, as well as in and around magnetars and
neutron stars. The PolSTAR design is based on the technology developed for the
Nuclear Spectroscopic Telescope Array (NuSTAR) mission launched in June 2012.
In particular, it uses the same X-ray optics, extendable telescope boom,
optical bench, and CdZnTe detectors as NuSTAR. The mission has the sensitivity
to measure ~1% linear polarization fractions for X-ray sources with fluxes down
to ~5 mCrab. This paper describes the PolSTAR design as well as the science
drivers and the potential science return.