Normalized to: Beeman, J.
[1]
oai:arXiv.org:1405.3782 [pdf] - 862787
Search for axioelectric effect of solar axions using BGO scintillating
bolometer
Derbin, A. V.;
Gironi, L.;
Nagorny, S. S.;
Pattavina, L.;
Beeman, J. W.;
Bellini, F.;
Biassoni, M.;
Capelli, S.;
Clemenza, M.;
Drachnev, I. S.;
Ferri, E.;
Giachero, A.;
Gotti, C.;
Kayunov, A. S.;
Maiano, C.;
Maino, M.;
Muratova, V. N.;
Pavan, M.;
Pirro, S.;
Sisti, M.;
Semenov, D. A.;
Unzhakov, E. V.
Submitted: 2014-05-15, last modified: 2014-09-08
A search for axioelectric absorption of solar axions produced in the $ p + d
\rightarrow {^3\rm{He}}+\gamma~(5.5~ \rm{MeV})$ reactions has been performed
with a BGO detector placed in a low-background setup. A model-independent limit
on an axion-nucleon and axion-electron coupling constant has been obtained: $|
g_{Ae}\times g_{AN}^3|< 1.9\times 10^{-10}$ for 90% confidence level. The
constrains of the axion-electron coupling have been obtained for hadronic axion
with masses in (0.1 - 1) MeV range: $|g_{Ae}| \leq (0.96 - 8.2)\times 10^{-8}$.
[2]
oai:arXiv.org:1209.2519 [pdf] - 621874
The low energy spectrum of TeO2 bolometers: results and dark matter
perspectives for the CUORE-0 and CUORE experiments
Alessandria, F.;
Ardito, R.;
Artusa, D. R.;
Avignone, F. T.;
Azzolini, O.;
Balata, M.;
Banks, T. I.;
Bari, G.;
Beeman, J.;
Bellini, F.;
Bersani, A.;
Biassoni, M.;
Bloxham, T.;
Brofferio, C.;
Bucci, C.;
Cai, X. Z.;
Canonica, L.;
Capelli, S.;
Carbone, L.;
Cardani, L.;
Carrettoni, M.;
Casali, N.;
Chott, N.;
Clemenza, M.;
Cosmelli, C.;
Cremonesi, O.;
Creswick, R. J.;
Dafinei, I.;
Dally, A.;
Datskov, V.;
De Biasi, A.;
Decowski, M. P.;
Deninno, M. M.;
Di Domizio, S.;
di Vacri, M. L.;
Ejzak, L.;
Faccini, R.;
Fang, D. Q.;
Farach, H. A.;
Ferri, E.;
Ferroni, F.;
Fiorini, E.;
Franceschi, M. A.;
Freedman, S. J.;
Frossati, G.;
Fujikawa, B. K.;
Giachero, A.;
Gironi, L.;
Giuliani, A.;
Goett, J. J.;
Gorla, P.;
Gotti, C.;
Guardincerri, E.;
Gutierrez, T. D.;
Haller, E. E.;
Han, K.;
Heeger, K. M.;
Huang, H. Z.;
Kadel, R.;
Kazkaz, K.;
Keppel, G.;
Kogler, L.;
Kolomensky, Yu. G.;
Lenz, D.;
Li, Y. L.;
Ligi, C.;
Liu, X.;
Ma, Y. G.;
Maiano, C.;
Maino, M.;
Martinez, M.;
Maruyama, R. H.;
Moggi, N.;
Morganti, S.;
Napolitano, T.;
Newman, S.;
Nisi, S.;
Nones, C.;
Norman, E. B.;
Nucciotti, A.;
Orio, F.;
Orlandi, D.;
Ouellet, J. L.;
Pallavicini, M.;
Palmieri, V.;
Pattavina, L.;
Pavan, M.;
Pedretti, M.;
Pessina, G.;
Pirro, S.;
Previtali, E.;
Rampazzo, V.;
Rimondi, F.;
Rosenfeld, C.;
Rusconi, C.;
Sangiorgio, S.;
Scielzo, N. D.;
Sisti, M.;
Smith, A. R.;
Stivanello, F.;
Taffarello, L.;
Tenconi, M.;
Tian, W. D.;
Tomei, C.;
Trentalange, S.;
Ventura, G.;
Vignati, M.;
Wang, B. S.;
Wang, H. W.;
Whitten, C. A.;
Wise, y T.;
Woodcraft, A.;
Zanotti, L.;
Zarra, C.;
Zhu, B. X.;
Zucchelli, S.
Submitted: 2012-09-12, last modified: 2013-02-01
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three
of them we were able to set the energy threshold around 3 keV using a new
analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3
keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak
is presently unknown, but its presence is confirmed by a reanalysis of 62.7
kg.days of data from the finished CUORICINO experiment. Finally, we report the
expected sensitivities of the CUORE0 (52 bolometers) and CUORE (988 bolometers)
experiments to a WIMP annual modulation signal.
[3]
oai:arXiv.org:0903.1354 [pdf] - 22164
The Large APEX Bolometer Camera LABOCA
Siringo, G.;
Kreysa, E.;
Kovacs, A.;
Schuller, F.;
Weiss, A.;
Esch, W.;
Gemuend, H. P.;
Jethava, N.;
Lundershausen, G.;
Colin, A.;
Guesten, R.;
Menten, K. M.;
Beelen, A.;
Bertoldi, F.;
Beeman, J. W.;
Haller, E. E.
Submitted: 2009-03-07
The Large APEX Bolometer Camera, LABOCA, has been commissioned for operation
as a new facility instrument t the Atacama Pathfinder Experiment 12m
submillimeter telescope. This new 295-bolometer total power camera, operating
in the 870 micron atmospheric window, combined with the high efficiency of APEX
and the excellent atmospheric transmission at the site, offers unprecedented
capability in mapping submillimeter continuum emission for a wide range of
astronomical purposes.
[4]
oai:arXiv.org:0710.5498 [pdf] - 6510
Debris disks around Sun-like stars
Trilling, D. E.;
Bryden, G.;
Beichman, C. A.;
Rieke, G. H.;
Su, K. Y. L.;
Stansberry, J. A.;
Blaylock, M.;
Stapelfeldt, K. R.;
Beeman, J. W.;
Haller, E. E.
Submitted: 2007-10-29
We have observed nearly 200 FGK stars at 24 and 70 microns with the Spitzer
Space Telescope. We identify excess infrared emission, including a number of
cases where the observed flux is more than 10 times brighter than the predicted
photospheric flux, and interpret these signatures as evidence of debris disks
in those systems. We combine this sample of FGK stars with similar published
results to produce a sample of more than 350 main sequence AFGKM stars. The
incidence of debris disks is 4.2% (+2.0/-1.1) at 24 microns for a sample of 213
Sun-like (FG) stars and 16.4% (+2.8/-2.9) at 70 microns for 225 Sun-like (FG)
stars. We find that the excess rates for A, F, G, and K stars are statistically
indistinguishable, but with a suggestion of decreasing excess rate toward the
later spectral types; this may be an age effect. The lack of strong trend among
FGK stars of comparable ages is surprising, given the factor of 50 change in
stellar luminosity across this spectral range. We also find that the incidence
of debris disks declines very slowly beyond ages of 1 billion years.
[5]
oai:arXiv.org:0707.2103 [pdf] - 3082
Absolute Calibration and Characterization of the Multiband Imaging
Photometer for Spitzer. III. An Asteroid-based Calibration of MIPS at 160
microns
Stansberry, J. A.;
Gordon, K. D.;
Bhattacharya, B.;
Engelbracht, C. W.;
Rieke, G. H.;
Marleau, F. R.;
Fadda, D.;
Frayer, D. T.;
Noriega-Crespo, A.;
Wachter, S.;
Young, E. T.;
Mueller, T. G.;
Kelly, D. M.;
Blaylock, M.;
Henderson, D.;
Neugebauer, G.;
Beeman, J. W.;
Haller, E. E.
Submitted: 2007-07-16, last modified: 2007-07-24
We describe the absolute calibration of the Multiband Imaging Photometer for
Spitzer (MIPS) 160 micron channel. After the on-orbit discovery of a near-IR
ghost image that dominates the signal for sources hotter than about 2000 K, we
adopted a strategy utilizing asteroids to transfer the absolute calibrations of
the MIPS 24 and 70 micron channels to the 160 micron channel. Near-simultaneous
observations at all three wavelengths are taken, and photometry at the two
shorter wavelengths is fit using the Standard Thermal Model. The 160 micron
flux density is predicted from those fits and compared with the observed 160
micron signal to derive the conversion from instrumental units to surface
brightness. The calibration factor we derive is 41.7 MJy/sr/MIPS160 (MIPS160
being the instrumental units). The scatter in the individual measurements of
the calibration factor, as well as an assesment of the external uncertainties
inherent in the calibration, lead us to adopt an uncertainty of 5.0
MJy/sr/MIPS160 (12%) for the absolute uncertainty on the 160 micron flux
density of a particular source as determined from a single measurement. For
sources brighter than about 2 Jy, non-linearity in the response of the 160
micron detectors produces an under-estimate of the flux density: for objects as
bright as 4 Jy, measured flux densities are likely to be ~20% too low. This
calibration has been checked against that of ISO (using ULIRGS) and IRAS (using
IRAS-derived diameters), and is consistent with those at the 5% level.
[6]
oai:arXiv.org:astro-ph/0003346 [pdf] - 1232433
16 x 25 Ge:Ga Detector Arrays for FIFI LS
Submitted: 2000-03-23
We are developing two-dimensional 16 x 25 pixel detector arrays of both
unstressed and stressed Ge:Ga photoconductive detectors for far-infrared
astronomy from SOFIA. The arrays, based on earlier 5 x 5 detector arrays used
on the KAO, will be for our new instrument, the Far Infrared Field Imaging Line
Spectrometer (FIFI LS). The unstressed Ge:Ga detector array will cover the
wavelength range from 40 to 120 microns, and the stressed Ge:Ga detector array
from 120 to 210 microns. The detector arrays will be operated with multiplexed
integrating amplifiers with cryogenic readout electronics located close to the
detector arrays. The design of the stressed detector array and results of
current measurements on several prototype 16 pixel linear arrays are reported.
They demonstrate the feasibility of the current concept. ***This paper does not
include Figures due to astro-ph size limitations. Please download entire file
at http://fifi-ls.mpe-garching.mpg.de/spie.det.ps.gz ***