Normalized to: Bauleo, P.
[9]
oai:arXiv.org:0811.1518 [pdf] - 1934284
Multi-wavelength Calibration Procedure for the Pierre Auger Observatory
Fluorescence Detectors
Submitted: 2008-11-10, last modified: 2009-02-12
We present a method to measure the relative spectral response of the Pierre
Auger Observatory Fluorescence Detector. The calibration was done at
wavelengths of 320, 337, 355, 380 and 405 nm using an end-to-end technique in
which the response of all detector components are combined in a single
measurement. A xenon flasher and notch-filters were used as the light source
for the calibration device. The overall uncertainty is 5%.
[10]
oai:arXiv.org:0712.2832 [pdf] - 1934207
The Surface Detector System of the Pierre Auger Observatory
Allekotte, I.;
Barbosa, A. F.;
Bauleo, P.;
Bonifazi, C.;
Civit, B.;
Escobar, C. O.;
Garcia, B.;
Guedes, G.;
Berisso, M. Gomez;
Harton, J. L.;
Healy, M.;
Kaducak, M.;
Mantsch, P.;
Mazur, P. O.;
Newman-Holmes, C.;
Pepe, I.;
Rodriguez-Cabo, I.;
Salazar, H.;
Grande, N. Smetniansky-De;
Warner, D.
Submitted: 2007-12-17
The Pierre Auger Observatory is designed to study cosmic rays with energies
greater than 10^{19} eV. Two sites are envisaged for the observatory, one in
each hemisphere, for complete sky coverage. The southern site of the Auger
Observatory, now approaching completion in Mendoza, Argentina, features an
array of 1600 water-Cherenkov surface detector stations covering 3000 km^2,
together with 24 fluorescence telescopes to record the air shower cascades
produced by these particles. The two complementary detector techniques together
with the large collecting area form a powerful instrument for these studies.
Although construction is not yet complete, the Auger Observatory has been
taking data stably since January 2004 and the first physics results are being
published. In this paper we describe the design features and technical
characteristics of the surface detector stations of the Pierre Auger
Observatory.
[11]
oai:arXiv.org:0708.1924 [pdf] - 1934159
The Absolute, Relative and Multi-Wavelength Calibration of the Pierre
Auger Observatory Fluorescence Detectors
Knapik, R.;
Bauleo, P.;
Becker, B. R.;
Brack, J.;
Caruso, R.;
Fratte, C. Delle;
Dorofeev, A.;
Harton, J.;
Insolia, A.;
Matthews, J. A. J.;
Menshikov, A.;
Ortolani, F.;
Petrinca, P.;
Pichel, A.;
Riggi, S.;
Roberts, M.;
Martino, J. Rodriguez;
Rovero, A. C.;
Scuderi, M.;
Tamashiro, A.;
Torresi, D.;
Tuci, V.;
Wiencke, L.
Submitted: 2007-08-14
Absolute calibration of the Pierre Auger Observatory fluorescence detectors
uses a 375 nm light source at the telescope aperture. This end-to-end technique
accounts for the combined effects of all detector components in a single
measurement. The relative response has been measured at wavelengths of 320,
337, 355, 380 and 405 nm, defining a spectral response curve which has been
normalized to the absolute calibration. Before and after each night of data
taking a relative calibration of the phototubes is performed. This relative
calibration is used to track both short and long term changes in the detector's
response. A cross check of the calibration in some phototubes is performed
using an independent laser technique. Overall uncertainties, current results
and future plans are discussed.
[12]
oai:arXiv.org:astro-ph/0510320 [pdf] - 76816
The trigger system of the Pierre Auger Surface Detector: operation,
efficiency and stability
Allard, D.;
Armengaud, E.;
Allekotte, I.;
Allison, P.;
Aublin, J.;
Ave, M.;
Bauleo, P.;
Beatty, J.;
Beau, T.;
Bertou, X.;
Billoir, P.;
Bonifazi, C.;
Chou, A.;
Chye, J.;
Dagoret-Campagne, S.;
Dorofeev, A.;
Ghia, P. L.;
Berisso, M. Gomez;
Gorgi, A.;
Hamilton, J. C.;
Harton, J.;
Knapik, R.;
Lachaud, C.;
Lhenry-Yvon, I.;
Letessier-Selvon, A.;
Matthews, J.;
Medina, C.;
Meyhandan, R.;
Navarra, G.;
Nitz, D.;
Parizot, E.;
Revenu, B.;
Szadkowski, Z.;
Yamamoto, T.
Submitted: 2005-10-11
The trigger system of the Surface Detector (SD) of the Pierre Auger
Observatory is described, from the identification of candidate showers ($E>1$
EeV) at the level of a single station, among a huge background (mainly single
muons), up to the selection of real events and the rejection of random
coincidences at a higher central trigger level (including the reconstruction
accuracy). Efficiency of a single station trigger is evaluated using real data
, and the high performance of event selection hierarchy will be demonstrated.
[13]
oai:arXiv.org:astro-ph/0507590 [pdf] - 1938930
Measurement of the Lateral Distribution Function of UHECR Air Showers
with the Pierre Auger Observatory
Barnhill, D.;
Bauleo, P.;
Dova, M. T.;
Harton, J.;
Knapik, R.;
Knapp, J.;
Lee, J.;
Mancenido, M.;
Mariazzi, A. G.;
Maris, I. C.;
Newton, D.;
Roth, M.;
Schmidt, T.;
Watson, AA
Submitted: 2005-07-25
The Pierre Auger Observatory is being used to study cosmic rays with energies
larger than 10 EeV. An essential quantity that must be deduced from data is the
lateral distribution function (LDF). Knowledge of the LDF is important for the
reconstruction of the shower core and the shower direction. Here we describe
how the LDF is measured using the large sample of events recorded with the
surface detector (SD) array and with a small sample observed with the
fluorescence detectors (FD). For hybrid events, in which SD and FD measurements
of the same shower are available, the core position is much better constrained
than for SD-only events, thus providing an important cross-check on the LDF
determined from SD measurements alone.
[14]
oai:arXiv.org:astro-ph/0507347 [pdf] - 1938912
Absolute Calibration of the Auger Fluorescence Detectors
Submitted: 2005-07-14
Absolute calibration of the Pierre Auger Observatory fluorescence detectors
uses a light source at the telescope aperture. The technique accounts for the
ombined effects of all detector components in a single measurement. The
calibrated 2.5 m diameter light source fills the aperture, providing uniform
illumination to each pixel. The known flux from the light source and the
response of the acquisition system give the required calibration for each
pixel. In the lab, light source uniformity is studied using CCD images and the
intensity is measured relative to NIST-calibrated photodiodes. Overall
uncertainties are presently 12%, and are dominated by systematics.
[15]
oai:arXiv.org:astro-ph/0104338 [pdf] - 42077
TANGO ARRAY An Air Shower Experiment in Buenos Aires
Submitted: 2001-04-20
A new Air Shower Observatory has been constructed in Buenos Aires during
1999, and commissioned and set in operation in 2000. The observatory consists
of an array of four water \v{C}erenkov detectors, enclosing a geometrical area
of $\sim$ 30.000 m$^{2}$, and is optimized for the observation of cosmic rays
in the ``knee'' energy region. The array detects $\sim$ 250 to $\sim$ 1500
showers/day, depending on the selected triggering condition. In this paper, the
design and construction of the array, and the automatic system for data
adquisition, daily calibration, and monitoring, are described. Also, the Monte
Carlo simulations performed to develop a shower database, as well as the
studies performed using the database to estimate the response and the angular
and energy resolutions of the array, are presented in detail.
[16]
oai:arXiv.org:hep-ex/9707036 [pdf] - 113380
A Water Tank Cerenkov Detector for Very High Energy Astroparticles
Bauleo, P.;
Etchegoyen, A.;
Niello, J. O. Fernandez;
Ferrero, A. M. J.;
Filevich, A.;
Guerard, C. K.;
Hasenbalg, F.;
Mostafa, M. A.;
Ravignani, D.;
Martino, J. Rodriguez
Submitted: 1997-07-24
Extensive airshower detection is an important issue in current astrophysics
endeavours. Surface arrays detectors are a common practice since they are easy
to handle and have a 100% duty cycle. In this work we present an experimental
study of the parameters relevant to the design of a water Cerenkov detector for
high energy airshowers. This detector is conceived as part of the surface array
of the Pierre Auger Project, which is expected to be sensitive to ultra high
energy cosmic rays. In this paper we focus our attention in the geometry of the
tank and its inner liner material, discussing pulse shapes and charge
collections.