sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Bauer, S. -M.

Normalized to: Bauer, S.

15 article(s) in total. 718 co-authors, from 1 to 9 common article(s). Median position in authors list is 5,0.

[1]  oai:arXiv.org:1909.06048  [pdf] - 2007972
An improved upper limit on the neutrino mass from a direct kinematic method by KATRIN
Aker, M.; Altenmüller, K.; Arenz, M.; Babutzka, M.; Barrett, J.; Bauer, S.; Beck, M.; Beglarian, A.; Behrens, J.; Bergmann, T.; Besserer, U.; Blaum, K.; Block, F.; Bobien, S.; Bokeloh, K.; Bonn, J.; Bornschein, B.; Bornschein, L.; Bouquet, H.; Brunst, T.; Caldwell, T. S.; La Cascio, L.; Chilingaryan, S.; Choi, W.; Corona, T. J.; Debowski, K.; Deffert, M.; Descher, M.; Doe, P. J.; Dragoun, O.; Drexlin, G.; Dunmore, J. A.; Dyba, S.; Edzards, F.; Eisenblätter, L.; Eitel, K.; Ellinger, E.; Engel, R.; Enomoto, S.; Erhard, M.; Eversheim, D.; Fedkevych, M.; Felden, A.; Fischer, S.; Flatt, B.; Formaggio, J. A.; Fränkle, F. M.; Franklin, G. B.; Frankrone, H.; Friedel, F.; Fuchs, D.; Fulst, A.; Furse, D.; Gauda, K.; Gemmeke, H.; Gil, W.; Glück, F.; Görhardt, S.; Groh, S.; Grohmann, S.; Grössle, R.; Gumbsheimer, R.; Minh, M. Ha; Hackenjos, M.; Hannen, V.; Harms, F.; Hartmann, J.; Haußmann, N.; Heizmann, F.; Helbing, K.; Hickford, S.; Hilk, D.; Hillen, B.; Hillesheimer, D.; Hinz, D.; Höhn, T.; Holzapfel, B.; Holzmann, S.; Houdy, T.; Howe, M. A.; Huber, A.; Jansen, A.; Kaboth, A.; Karl, C.; Kazachenko, O.; Kellerer, J.; Kernert, N.; Kippenbrock, L.; Kleesiek, M.; Klein, M.; Köhler, C.; Köllenberger, L.; Kopmann, A.; Korzeczek, M.; Kosmider, A.; Kovalí, A.; Krasch, B.; Kraus, M.; Krause, H.; Kuckert, L.; Kuffner, B.; Kunka, N.; Lasserre, T.; Le, T. L.; Lebeda, O.; Leber, M.; Lehnert, B.; Letnev, J.; Leven, F.; Lichter, S.; Lobashev, V. M.; Lokhov, A.; Machatschek, M.; Malcherek, E.; Müller, K.; Mark, M.; Marsteller, A.; Martin, E. L.; Melzer, C.; Menshikov, A.; Mertens, S.; Minter, L. I.; Mirz, S.; Monreal, B.; Guzman, P. I. Morales; Müller, K.; Naumann, U.; Ndeke, W.; Neumann, H.; Niemes, S.; Noe, M.; Oblath, N. S.; Ortjohann, H. -W.; Osipowicz, A.; Ostrick, B.; Otten, E.; Parno, D. S.; Phillips, D. G.; Plischke, P.; Pollithy, A.; Poon, A. W. P.; Pouryamout, J.; Prall, M.; Priester, F.; Röllig, M.; Röttele, C.; Ranitzsch, P. C. -O.; Rest, O.; Rinderspacher, R.; Robertson, R. G. H.; Rodenbeck, C.; Rohr, P.; Roll, Ch.; Rupp, S.; Rysavy, M.; Sack, R.; Saenz, A.; Schäfer, P.; Schimpf, L.; Schlösser, K.; Schlösser, M.; Schlüter, L.; Schön, H.; Schönung, K.; Schrank, M.; Schulz, B.; Schwarz, J.; Seitz-Moskaliuk, H.; Seller, W.; Sibille, V.; Siegmann, D.; Skasyrskaya, A.; Slezak, M.; Spalek, A.; Spanier, F.; Steidl, M.; Steinbrink, N.; Sturm, M.; Suesser, M.; Sun, M.; Tcherniakhovski, D.; Telle, H. H.; Thümmler, T.; Thorne, L. A.; Titov, N.; Tkachev, I.; Trost, N.; Urban, K.; Venos, D.; Valerius, K.; VanDevender, B. A.; Vianden, R.; Hernandez, A. P. Vizcaya; Wall, B. L.; Wüstling, S.; Weber, M.; Weinheimer, C.; Weiss, C.; Welte, S.; Wendel, J.; Wierman, K. J.; Wilkerson, J. F.; Wolf, J.; Xu, W.; Yen, Y. -R.; Zacher, M.; Zadorozhny, S.; Zboril, M.; Zeller, G.
Comments:
Submitted: 2019-09-13
We report on the neutrino mass measurement result from the first four-week science run of the Karlsruhe Tritium Neutrino experiment KATRIN in spring 2019. Beta-decay electrons from a high-purity gaseous molecular tritium source are energy analyzed by a high-resolution MAC-E filter. A fit of the integrated electron spectrum over a narrow interval around the kinematic endpoint at 18.57 keV gives an effective neutrino mass square value of $(-1.0^{+0.9}_{-1.1})$ eV$^2$. From this we derive an upper limit of 1.1 eV (90$\%$ confidence level) on the absolute mass scale of neutrinos. This value coincides with the KATRIN sensitivity. It improves upon previous mass limits from kinematic measurements by almost a factor of two and provides model-independent input to cosmological studies of structure formation.
[2]  oai:arXiv.org:1903.02464  [pdf] - 1859121
4MOST: Project overview and information for the First Call for Proposals
de Jong, R. S.; Agertz, O.; Berbel, A. Agudo; Aird, J.; Alexander, D. A.; Amarsi, A.; Anders, F.; Andrae, R.; Ansarinejad, B.; Ansorge, W.; Antilogus, P.; Anwand-Heerwart, H.; Arentsen, A.; Arnadottir, A.; Asplund, M.; Auger, M.; Azais, N.; Baade, D.; Baker, G.; Baker, S.; Balbinot, E.; Baldry, I. K.; Banerji, M.; Barden, S.; Barklem, P.; Barthélémy-Mazot, E.; Battistini, C.; Bauer, S.; Bell, C. P. M.; Bellido-Tirado, O.; Bellstedt, S.; Belokurov, V.; Bensby, T.; Bergemann, M.; Bestenlehner, J. M.; Bielby, R.; Bilicki, M.; Blake, C.; Bland-Hawthorn, J.; Boeche, C.; Boland, W.; Boller, T.; Bongard, S.; Bongiorno, A.; Bonifacio, P.; Boudon, D.; Brooks, D.; Brown, M. J. I.; Brown, R.; Brüggen, M.; Brynnel, J.; Brzeski, J.; Buchert, T.; Buschkamp, P.; Caffau, E.; Caillier, P.; Carrick, J.; Casagrande, L.; Case, S.; Casey, A.; Cesarini, I.; Cescutti, G.; Chapuis, D.; Chiappini, C.; Childress, M.; Christlieb, N.; Church, R.; Cioni, M. -R. L.; Cluver, M.; Colless, M.; Collett, T.; Comparat, J.; Cooper, A.; Couch, W.; Courbin, F.; Croom, S.; Croton, D.; Daguisé, E.; Dalton, G.; Davies, L. J. M.; Davis, T.; de Laverny, P.; Deason, A.; Dionies, F.; Disseau, K.; Doel, P.; Döscher, D.; Driver, S. P.; Dwelly, T.; Eckert, D.; Edge, A.; Edvardsson, B.; Youssoufi, D. El; Elhaddad, A.; Enke, H.; Erfanianfar, G.; Farrell, T.; Fechner, T.; Feiz, C.; Feltzing, S.; Ferreras, I.; Feuerstein, D.; Feuillet, D.; Finoguenov, A.; Ford, D.; Fotopoulou, S.; Fouesneau, M.; Frenk, C.; Frey, S.; Gaessler, W.; Geier, S.; Fusillo, N. Gentile; Gerhard, O.; Giannantonio, T.; Giannone, D.; Gibson, B.; Gillingham, P.; González-Fernández, C.; Gonzalez-Solares, E.; Gottloeber, S.; Gould, A.; Grebel, E. K.; Gueguen, A.; Guiglion, G.; Haehnelt, M.; Hahn, T.; Hansen, C. J.; Hartman, H.; Hauptner, K.; Hawkins, K.; Haynes, D.; Haynes, R.; Heiter, U.; Helmi, A.; Aguayo, C. Hernandez; Hewett, P.; Hinton, S.; Hobbs, D.; Hoenig, S.; Hofman, D.; Hook, I.; Hopgood, J.; Hopkins, A.; Hourihane, A.; Howes, L.; Howlett, C.; Huet, T.; Irwin, M.; Iwert, O.; Jablonka, P.; Jahn, T.; Jahnke, K.; Jarno, A.; Jin, S.; Jofre, P.; Johl, D.; Jones, D.; Jönsson, H.; Jordan, C.; Karovicova, I.; Khalatyan, A.; Kelz, A.; Kennicutt, R.; King, D.; Kitaura, F.; Klar, J.; Klauser, U.; Kneib, J.; Koch, A.; Koposov, S.; Kordopatis, G.; Korn, A.; Kosmalski, J.; Kotak, R.; Kovalev, M.; Kreckel, K.; Kripak, Y.; Krumpe, M.; Kuijken, K.; Kunder, A.; Kushniruk, I.; Lam, M. I; Lamer, G.; Laurent, F.; Lawrence, J.; Lehmitz, M.; Lemasle, B.; Lewis, J.; Li, B.; Lidman, C.; Lind, K.; Liske, J.; Lizon, J. -L.; Loveday, J.; Ludwig, H. -G.; McDermid, R. M.; Maguire, K.; Mainieri, V.; Mali, S.; Mandel, H.; Mandel, K.; Mannering, L.; Martell, S.; Delgado, D. Martinez; Matijevic, G.; McGregor, H.; McMahon, R.; McMillan, P.; Mena, O.; Merloni, A.; Meyer, M. J.; Michel, C.; Micheva, G.; Migniau, J. -E.; Minchev, I.; Monari, G.; Muller, R.; Murphy, D.; Muthukrishna, D.; Nandra, K.; Navarro, R.; Ness, M.; Nichani, V.; Nichol, R.; Nicklas, H.; Niederhofer, F.; Norberg, P.; Obreschkow, D.; Oliver, S.; Owers, M.; Pai, N.; Pankratow, S.; Parkinson, D.; Parry, I.; Paschke, J.; Paterson, R.; Pecontal, A.; Phillips, D.; Pillepich, A.; Pinard, L.; Pirard, J.; Piskunov, N.; Plank, V.; Plüschke, D.; Pons, E.; Popesso, P.; Power, C.; Pragt, J.; Pramskiy, A.; Pryer, D.; Quattri, M.; Queiroz, A. B. de Andrade; Quirrenbach, A.; Rahurkar, S.; Raichoor, A.; Ramstedt, S.; Rau, A.; Recio-Blanco, A.; Reiss, R.; Renaud, F.; Revaz, Y.; Rhode, P.; Richard, J.; Richter, A. D.; Rix, H. -W.; Robotham, A. S. G.; Roelfsema, R.; Romaniello, M.; Rosario, D.; Rothmaier, F.; Roukema, B.; Ruchti, G.; Rupprecht, G.; Rybizki, J.; Ryde, N.; Saar, A.; Sadler, E.; Sahlén, M.; Salvato, M.; Sassolas, B.; Saunders, W.; Saviauk, A.; Sbordone, L.; Schmidt, T.; Schnurr, O.; Scholz, R. -D.; Schwope, A.; Seifert, W.; Shanks, T.; Sheinis, A.; Sivov, T.; Skúladóttir, Á.; Smartt, S.; Smedley, S.; Smith, G.; Smith, R.; Sorce, J.; Spitler, L.; Starkenburg, E.; Steinmetz, M.; Stilz, I.; Storm, J.; Sullivan, M.; Sutherland, W.; Swann, E.; Tamone, A.; Taylor, E. N.; Teillon, J.; Tempel, E.; ter Horst, R.; Thi, W. -F.; Tolstoy, E.; Trager, S.; Traven, G.; Tremblay, P. -E.; Tresse, L.; Valentini, M.; van de Weygaert, R.; Ancker, M. van den; Veljanoski, J.; Venkatesan, S.; Wagner, L.; Wagner, K.; Walcher, C. J.; Waller, L.; Walton, N.; Wang, L.; Winkler, R.; Wisotzki, L.; Worley, C. C.; Worseck, G.; Xiang, M.; Xu, W.; Yong, D.; Zhao, C.; Zheng, J.; Zscheyge, F.; Zucker, D.
Comments: Part of the 4MOST issue of The Messenger, published in preparation of 4MOST Community Workshop, see http://www.eso.org/sci/meetings/2019/4MOST.html
Submitted: 2019-03-06, last modified: 2019-04-01
We introduce the 4-metre Multi-Object Spectroscopic Telescope (4MOST), a new high-multiplex, wide-field spectroscopic survey facility under development for the four-metre-class Visible and Infrared Survey Telescope for Astronomy (VISTA) at Paranal. Its key specifications are: a large field of view (FoV) of 4.2 square degrees and a high multiplex capability, with 1624 fibres feeding two low-resolution spectrographs ($R = \lambda/\Delta\lambda \sim 6500$), and 812 fibres transferring light to the high-resolution spectrograph ($R \sim 20\,000$). After a description of the instrument and its expected performance, a short overview is given of its operational scheme and planned 4MOST Consortium science; these aspects are covered in more detail in other articles in this edition of The Messenger. Finally, the processes, schedules, and policies concerning the selection of ESO Community Surveys are presented, commencing with a singular opportunity to submit Letters of Intent for Public Surveys during the first five years of 4MOST operations.
[3]  oai:arXiv.org:1807.08932  [pdf] - 1721260
Laser and Radio Tracking for Planetary Science Missions - A Comparison
Comments: Accepted for publication in Journal of Geodesy
Submitted: 2018-07-24
At present, tracking data for planetary missions largely consists of radio observables: range-rate range and angular position. Future planetary missions may use Interplanetary Laser Ranging (ILR) as a tracking observable. Two-way ILR will provide range data that are about 2 orders of magnitude more accurate than radio-based range data. ILR does not produce Doppler data, however. In this article, we compare the relative strength of radio Doppler and laser range data for the retrieval of parameters of interest in planetary missions, to clarify and quantify the science case of ILR, with a focus on geodetic observables. We first provide an overview of the near-term attainable quality of ILR, in terms of both the realization of the observable and the models used to process the measurements. Subsequently, we analyze the sensitivity of radio-Doppler and laser-range measurements in representative mission scenarios. We use both an analytical approximation and numerical analyses of the relative sensitivity of ILR and radio Doppler observables for more general cases. We show that mm-precise range normal points are feasible for ILR, but mm-level accuracy and stability is unlikely to be attained, due to a combination of instrumental and model errors. ILR has the potential for superior performance in observing signatures in the data with a characteristic period of greater than 0.33-1.65 hours This indicates that Doppler tracking will typically remain the method of choice for gravity field determination and spacecraft orbit determination in planetary missions. Laser ranging data, however, are shown to have a significant advantage for the retrieval of rotational and tidal characteristics from landers. Similarly, laser ranging data will be superior for the construction of planetary ephemerides and the improvement of solar system tests of gravitation.
[4]  oai:arXiv.org:1612.05624  [pdf] - 1533526
Aeronomical constraints to the minimum mass and maximum radius of hot low-mass planets
Comments: Accepted for publication by A&A
Submitted: 2016-12-16
Stimulated by the discovery of a number of close-in low-density planets, we generalise the Jeans escape parameter taking hydrodynamic and Roche lobe effects into account. We furthermore define $\Lambda$ as the value of the Jeans escape parameter calculated at the observed planetary radius and mass for the planet's equilibrium temperature and considering atomic hydrogen, independently of the atmospheric temperature profile. We consider 5 and 10 $M_{\oplus}$ planets with an equilibrium temperature of 500 and 1000 K, orbiting early G-, K-, and M-type stars. Assuming a clear atmosphere and by comparing escape rates obtained from the energy-limited formula, which only accounts for the heating induced by the absorption of the high-energy stellar radiation, and from a hydrodynamic atmosphere code, which also accounts for the bolometric heating, we find that planets whose $\Lambda$ is smaller than 15-35 lie in the "boil-off" regime, where the escape is driven by the atmospheric thermal energy and low planetary gravity. We find that the atmosphere of hot (i.e. $T_{\rm eq}\gtrapprox$ 1000 K) low-mass ($M_{\rm pl}\lessapprox$ 5 $M_{\oplus}$) planets with $\Lambda$ < 15-35 shrinks to smaller radii so that their $\Lambda$ evolves to values higher than 15-35, hence out of the boil-off regime, in less than $\approx$500 Myr. Because of their small Roche lobe radius, we find the same result also for hot (i.e. $T_{\rm eq}\gtrapprox$ 1000 K) higher mass ($M_{\rm pl}\lessapprox$ 10 $M_{\oplus}$) planets with $\Lambda$ < 15-35, when they orbit M-dwarfs. For old, hydrogen-dominated planets in this range of parameters, $\Lambda$ should therefore be $\geq$15-35, which provides a strong constraint on the planetary minimum mass and maximum radius and can be used to predict the presence of aerosols and/or constrain planetary masses, for example.
[5]  oai:arXiv.org:1607.01269  [pdf] - 1528097
The Potsdam MRS Spectrograph - heritage of MUSE and the impact of cross-innovation in the process of technology transfer
Comments: 13 pages, 13 figures. Submitted in SPIE Astronomical Telescopes + Instrumentation, Paper No. 9912-72
Submitted: 2016-07-05, last modified: 2016-07-06
After having demonstrated that an IFU, attached to a microscope rather than to a telescope, is capable of differentiating complex organic tissue with spatially resolved Raman spectroscopy, we have launched a clinical validation program that utilizes a novel optimized fiber-coupled multi-channel spectrograph whose layout is based on the modular MUSE spectrograph concept. The new design features a telecentric input and has an extended blue performance, but otherwise maintains the properties of high throughput and excellent image quality over an octave of wavelength coverage with modest spectral resolution. We present the opto-mechanical layout and details of its optical performance.
[6]  oai:arXiv.org:1505.06492  [pdf] - 1056016
PEPSI: The high-resolution echelle spectrograph and polarimeter for the Large Binocular Telescope
Comments:
Submitted: 2015-05-24
PEPSI is the bench-mounted, two-arm, fibre-fed and stabilized Potsdam Echelle Polarimetric and Spectroscopic Instrument for the 2x8.4 m Large Binocular Telescope (LBT). Three spectral resolutions of either 43 000, 120 000 or 270 000 can cover the entire optical/red wavelength range from 383 to 907 nm in three exposures. Two 10.3kx10.3k CCDs with 9-{\mu}m pixels and peak quantum efficiencies of 96 % record a total of 92 echelle orders. We introduce a new variant of a wave-guide image slicer with 3, 5, and 7 slices and peak efficiencies between 96 %. A total of six cross dispersers cover the six wavelength settings of the spectrograph, two of them always simultaneously. These are made of a VPH-grating sandwiched by two prisms. The peak efficiency of the system, including the telescope, is 15% at 650 nm, and still 11% and 10% at 390 nm and 900 nm, respectively. In combination with the 110 m2 light-collecting capability of the LBT, we expect a limiting magnitude of 20th mag in V in the low-resolution mode. The R=120 000 mode can also be used with two, dual-beam Stokes IQUV polarimeters. The 270 000-mode is made possible with the 7-slice image slicer and a 100- {\mu}m fibre through a projected sky aperture of 0.74", comparable to the median seeing of the LBT site. The 43000-mode with 12-pixel sampling per resolution element is our bad seeing or faint-object mode. Any of the three resolution modes can either be used with sky fibers for simultaneous sky exposures or with light from a stabilized Fabry-Perot etalon for ultra-precise radial velocities. CCD-image processing is performed with the dedicated data-reduction and analysis package PEPSI-S4S. A solar feed makes use of PEPSI during day time and a 500-m feed from the 1.8 m VATT can be used when the LBT is busy otherwise. In this paper, we present the basic instrument design, its realization, and its characteristics.
[7]  oai:arXiv.org:1210.3167  [pdf] - 575095
A retrospective of the GREGOR solar telescope in scientific literature
Comments: 6 pages, 2 color figures, this is the pre-peer reviewed version of Denker et al. 2012, Astron. Nachr. 333, 810
Submitted: 2012-10-11
In this review, we look back upon the literature, which had the GREGOR solar telescope project as its subject including science cases, telescope subsystems, and post-focus instruments. The articles date back to the year 2000, when the initial concepts for a new solar telescope on Tenerife were first presented at scientific meetings. This comprehensive bibliography contains literature until the year 2012, i.e., the final stages of commissioning and science verification. Taking stock of the various publications in peer-reviewed journals and conference proceedings also provides the "historical" context for the reference articles in this special issue of Astronomische Nachrichten/Astronomical Notes.
[8]  oai:arXiv.org:1210.2921  [pdf] - 590823
The GREGOR Fabry-P\'erot Interferometer
Comments: 14 pages, 17 figures, 4 tables; pre-print of AN 333, p.880-893, 2012 (AN special issue to GREGOR)
Submitted: 2012-10-10
The GREGOR Fabry-P\'erot Interferometer (GFPI) is one of three first-light instruments of the German 1.5-meter GREGOR solar telescope at the Observatorio del Teide, Tenerife, Spain. The GFPI uses two tunable etalons in collimated mounting. Thanks to its large-format, high-cadence CCD detectors with sophisticated computer hard- and software it is capable of scanning spectral lines with a cadence that is sufficient to capture the dynamic evolution of the solar atmosphere. The field-of-view (FOV) of 50" x 38" is well suited for quiet Sun and sunspot observations. However, in the vector spectropolarimetric mode the FOV reduces to 25" x 38". The spectral coverage in the spectroscopic mode extends from 530-860 nm with a theoretical spectral resolution R of about 250,000, whereas in the vector spectropolarimetric mode the wavelength range is at present limited to 580-660 nm. The combination of fast narrow-band imaging and post-factum image restoration has the potential for discovery science concerning the dynamic Sun and its magnetic field at spatial scales down to about 50 km on the solar surface.
[9]  oai:arXiv.org:1207.3981  [pdf] - 1553813
The ERA2 facility: towards application of a fiber-based astronomical spectrograph for imaging spectroscopy in life sciences
Comments: 10 pages, 9 figures, SPIE Conference "Astronomical Telescopes and Instrumentation" 2012, Amsterdam
Submitted: 2012-07-17
Astronomical instrumentation is most of the time faced with challenging requirements in terms of sensitivity, stability, complexity, etc., and therefore leads to high performance developments that at first sight appear to be suitable only for the specific design application at the telescope. However, their usefulness in other disciplines and for other applications is not excluded. The ERA2 facility is a lab demonstrator, based on a high-performance astronomical spectrograph, which is intended to explore the innovation potential of fiber-coupled multi-channel spectroscopy for spatially resolved spectroscopy in life science, material sciences, and other areas of research.
[10]  oai:arXiv.org:1201.2098  [pdf] - 1092845
The quest for companions to post-common envelope binaries: I. Searching a sample of stars from the CSS and SDSS
Comments: accepted by A&A
Submitted: 2012-01-10
As part of an ongoing collaboration between student groups at high schools and professional astronomers, we have searched for the presence of circum-binary planets in a bona-fide unbiased sample of twelve post-common envelope binaries (PCEBs) from the Catalina Sky Survey (CSS) and the Sloan Digital Sky Survey (SDSS). Although the present ephemerides are significantly more accurate than previous ones, we find no clear evidence for orbital period variations between 2005 and 2011 or during the 2011 observing season. The sparse long-term coverage still permits O-C variations with a period of years and an amplitude of tens of seconds, as found in other systems. Our observations provide the basis for future inferences about the frequency with which planet-sized or brown-dwarf companions have either formed in these evolved systems or survived the common envelope (CE) phase.
[11]  oai:arXiv.org:1111.5509  [pdf] - 639012
The GREGOR Fabry-Perot Interferometer - A New Instrument for High-Resolution Spectropolarimetric Solar Observations
Comments: 6 pages, 2 figures; to be published in ASP Conference Series, 2nd ATST-EAST Workshop: "Magnetic Fields from the Photosphere to the Corona", Washington DC, USA, November 9-11, 2011
Submitted: 2011-11-23, last modified: 2011-11-24
Fabry-Perot interferometers have advantages over slit spectrographs because they allow fast narrow-band imaging and post-factum image reconstruction of spectropolarimetric data. Temperature, plasma velocity, and magnetic field maps can be derived from inversions of photospheric and chromospheric spectral lines, thus, advancing our understanding of the dynamic Sun and its magnetic fields at the smallest spatial scales. The GREGOR Fabry-Perot Interferometer (GFPI) is one of two firstlight instruments of the 1.5-meter GREGOR solar telescope, which is currently being commissioned at the Observatorio del Teide, Tenerife, Spain. The GFPI operates close to the diffraction limit of GREGOR, thus, providing access to fine structures as small as 60 km on the solar surface. The field-of-view of 52"x 40" is sufficiently large to cover significant portions of active regions. The GFPI is a tuneable dual-etalon system in a collimated mounting. Equipped with a full-Stokes polarimeter, it records spectropolarimetric data with a spectral resolution of R = 250,000 over the wavelength range from 530-860 nm. Large-format, high-cadence CCD detectors with powerful computer hard- and software facilitate scanning of spectral lines in time spans corresponding to the evolution time-scale of solar features. We present the main characteristics of the GFPI including the latest developments in software, mechanical mounts, and optics.
[12]  oai:arXiv.org:astro-ph/0606329  [pdf] - 1233815
Probing unexplored territories with MUSE: a second generation instrument for the VLT
Comments: Astronomical Telescopes and Instrumentation, SPIE 6265 Orlando 24-31May 2006 9 pages
Submitted: 2006-06-13
The Multi Unit Spectroscopic Explorer (MUSE) is a second-generation VLT panoramic integral-field spectrograph under preliminary design study. MUSE has a field of 1x1 arcmin**2 sampled at 0.2x0.2 arcsec**2 and is assisted by the VLT ground layer adaptive optics ESO facility using four laser guide stars. The simultaneous spectral range is 465-930 nm, at a resolution of R~3000. MUSE couples the discovery potential of a large imaging device to the measuring capabilities of a high-quality spectrograph, while taking advantage of the increased spatial resolution provided by adaptive optics. This makes MUSE a unique and tremendously powerful instrument for discovering and characterizing objects that lie beyond the reach of even the deepest imaging surveys. MUSE has also a high spatial resolution mode with 7.5x7.5 arcsec**2 field of view sampled at 25 milli-arcsec. In this mode MUSE should be able to obtain diffraction limited data-cubes in the 600-930 nm wavelength range. Although the MUSE design has been optimized for the study of galaxy formation and evolution, it has a wide range of possible applications; e.g. monitoring of outer planets atmosphere, environment of young stellar objects, super massive black holes and active nuclei in nearby galaxies or massive spectroscopic surveys of stellar fields in the Milky Way and nearby galaxies.
[13]  oai:arXiv.org:astro-ph/0606234  [pdf] - 82674
Prototype development of the Integral-Field unit for VIRUS
Comments: 11 pages, 13 figures, to be published in SPIE proc. 6273
Submitted: 2006-06-09
VIRUS is a planned integral-field instrument for the Hobby-Eberly Telescope (HET). In order to achieve a large field-of-view and high grasp at reasonable costs, the approach is to replicate integral-field units (IFU) and medium sized spectrographs many times. The Astrophysical Institute Potsdam (AIP) contributes to VIRUS with the development and testing of the IFU prototype. This paper describes the optomechanical design and the manufacture of the fiber-based IFU subsystem. The initial VIRUS development aims to produce a prototype and to measure its performance. Additionally, techniques will be investigated to allow industrial replication of the highly specific fiber-bundle layout. This will be necessary if this technique is to be applied to the next generation of even larger astronomical instrumentation.
[14]  oai:arXiv.org:astro-ph/0512557  [pdf] - 78757
PMAS: The Potsdam Multi Aperture Spectrophotometer. II. The Wide Integral Field Unit PPak
Comments: 14 pages, 21 figures, accepted at PASP
Submitted: 2005-12-22
PPak is a new fiber-based Integral Field Unit (IFU), developed at the Astrophysical Institute Potsdam, implemented as a module into the existing PMAS spectrograph. The purpose of PPak is to provide both an extended field-of-view with a large light collecting power for each spatial element, as well as an adequate spectral resolution. The PPak system consists of a fiber bundle with 331 object, 36 sky and 15 calibration fibers. The object and sky fibers collect the light from the focal plane behind a focal reducer lens. The object fibers of PPak, each 2.7 arcseconds in diameter, provide a contiguous hexagonal field-of-view of 74 times 64 arcseconds on the sky, with a filling factor of 60%. The operational wavelength range is from 400 to 900nm. The PPak-IFU, together with the PMAS spectrograph, are intended for the study of extended, low surface brightness objects, offering an optimization of total light-collecting power and spectral resolution. This paper describes the instrument design, the assembly, integration and tests, the commissioning and operational procedures, and presents the measured performance at the telescope.
[15]  oai:arXiv.org:astro-ph/0502581  [pdf] - 71372
PMAS, the Potsdam Multi-Aperture Spectrophotometer. I. Design, Manufacture, and Performance
Comments: accepted for publication in PASP, 18 pages, 21 figures
Submitted: 2005-02-28
We describe the design, manufacture, commissioning, and performance of PMAS, the Potsdam Multi-Aperture Spectrophotometer. PMAS is a dedicated integral field spectrophotometer, optimized to cover the optical wavelength regime of 0.35--1um. It is based on the lens array -- fiber bundle principle of operation. The instrument employs an all-refractive fiber spectrograph, built with CaF2 optics, to provide good transmission and high image quality over the entire nominal wavelength range. A set of user-selectable reflective gratings provides low to medium spectral resolution in first order of approx. 1.5, 3.2, and 7 A, depending on the groove density (1200, 600, 300 gr/mm). While the standard integral field unit (IFU) uses a 16x16 element lens array, which provides seeing-limited sampling in a relatively small field-of-view (FOV) in one of three magnifications (8x8, 12x12, or 16x16 arcsec^2, respectively), a recently retrofitted bare fiber bundle IFU (PPak) expands the FOV to a hexagonal area with a footprint of 65x74 arcsec^2. Other special features include a cryogenic CCD camera for field acquisition and guiding, a nod-shuffle mode for beam switching and improved sky background subtraction, and a scanning Fabry-Perot etalon in combination with the standard IFU (PYTHEAS mode). PMAS was initially designed and built as an experimental traveling instrument with optical interfaces to various telescopes (Calar Alto 3.5m, ESO-VLT, LBT). It is offered as a common user instrument at Calar Alto under contract with MPIA Heidelberg since 2002.