Normalized to: Bauer, O.
[1]
oai:arXiv.org:1005.1487 [pdf] - 1026738
The Photodetector Array Camera and Spectrometer (PACS) on the Herschel
Space Observatory
Poglitsch, A.;
Waelkens, C.;
Geis, N.;
Feuchtgruber, H.;
Vandenbussche, B.;
Rodriguez, L.;
Krause, O.;
Renotte, E.;
van Hoof, C.;
Saraceno, P.;
Cepa, J.;
Kerschbaum, F.;
Agnese, P.;
Ali, B.;
Altieri, B.;
Andreani, P.;
Augueres, J. -L.;
Balog, Z.;
Barl, L.;
Bauer, O. H.;
Belbachir, N.;
Benedettini, M.;
Billot, N.;
Boulade, O.;
Bischof, H.;
Blommaert, J.;
Callut, E.;
Cara, C.;
Cerulli, R.;
Cesarsky, D.;
Contursi, A.;
Creten, Y.;
De Meester, W.;
Doublier, V.;
Doumayrou, E.;
Duband, L.;
Exter, K.;
Genzel, R.;
Gillis, J. -M.;
Grözinger, U.;
Henning, T.;
Herreros, J.;
Huygen, R.;
Inguscio, M.;
Jakob, G.;
Jamar, C.;
Jean, C.;
de Jong, J.;
Katterloher, R.;
Kiss, C.;
Klaas, U.;
Lemke, D.;
Lutz, D.;
Madden, S.;
Marquet, B.;
Martignac, J.;
Mazy, A.;
Merken, P.;
Montfort, F.;
Morbidelli, L.;
Müller, T.;
Nielbock, M.;
Okumura, K.;
Orfei, R.;
Ottensamer, R.;
Pezzuto, S.;
Popesso, P.;
Putzeys, J.;
Regibo, S.;
Reveret, V.;
Royer, P.;
Sauvage, M.;
Schreiber, J.;
Stegmaier, J.;
Schmitt, D.;
Schubert, J.;
Sturm, E.;
Thiel, M.;
Tofani, G.;
Vavrek, R.;
Wetzstein, M.;
Wieprecht, E.;
Wiezorrek, E.
Submitted: 2010-05-10, last modified: 2010-05-20
The Photodetector Array Camera and Spectrometer (PACS) is one of the three
science instruments on ESA's far infrared and submillimetre observatory. It
employs two Ge:Ga photoconductor arrays (stressed and unstressed) with 16x25
pixels, each, and two filled silicon bolometer arrays with 16x32 and 32x64
pixels, respectively, to perform integral-field spectroscopy and imaging
photometry in the 60-210\mu\ m wavelength regime. In photometry mode, it
simultaneously images two bands, 60-85\mu\ m or 85-125\mu\m and 125-210\mu\ m,
over a field of view of ~1.75'x3.5', with close to Nyquist beam sampling in
each band. In spectroscopy mode, it images a field of 47"x47", resolved into
5x5 pixels, with an instantaneous spectral coverage of ~1500km/s and a spectral
resolution of ~175km/s. We summarise the design of the instrument, describe
observing modes, calibration, and data analysis methods, and present our
current assessment of the in-orbit performance of the instrument based on the
Performance Verification tests. PACS is fully operational, and the achieved
performance is close to or better than the pre-launch predictions.
[2]
oai:arXiv.org:1005.1073 [pdf] - 1026706
Dissecting the cosmic infra-red background with Herschel/PEP
Berta, S.;
Magnelli, B.;
Lutz, D.;
Altieri, B.;
Aussel, H.;
Andreani, P.;
Bauer, O.;
Bongiovanni, A.;
Cava, A.;
Cepa, J.;
Cimatti, A.;
Daddi, E.;
Dominguez, H.;
Elbaz, D.;
Feuchtgruber, H.;
Schreiber, N. M. Foerster;
Genzel, R.;
Gruppioni, C.;
Katterloher, R.;
Magdis, G.;
Maiolino, R.;
Nordon, R.;
Garcia, A. M. Perez;
Poglitsch, A.;
Popesso, P.;
Pozzi, F.;
Riguccini, L.;
Rodighiero, G.;
Saintonge, A.;
Santini, P.;
Sanchez-Portal, M.;
Shao, L.;
Sturm, E.;
Tacconi, L. J.;
Valtchanov, I.;
Wetzstein, M.;
Wieprecht, E.
Submitted: 2010-05-06
The constituents of the cosmic IR background (CIB) are studied at its peak
wavelengths (100 and 160 um) by exploiting Herschel/PACS observations of the
GOODS-N, Lockman Hole, and COSMOS fields in the PACS Evolutionary Probe (PEP)
guaranteed-time survey. The GOODS-N data reach 3 sigma depths of ~3.0 mJy at
100 um and ~5.7 mJy at 160 um. At these levels, source densities are 40 and 18
beams/source, respectively, thus hitting the confusion limit at 160 um.
Differential number counts extend from a few mJy up to 100-200 mJy, and are
approximated as a double power law, with the break lying between 5 and 10 mJy.
The available ancillary information allows us to split number counts into
redshift bins. At z<=0.5 we isolate a class of luminous sources (L(IR)~1e11
Lsun), whose SEDs resemble late-spiral galaxies, peaking at ~130 um restframe
and significantly colder than what is expected on the basis of pre-Herschel
models. By integrating number counts over the whole covered flux range, we
obtain a surface brightness of 6.36 +/- 1.67 and 6.58 +/-1.62 [nW m^-2 sr^-1]
at 100 and 160 um, resolving ~45% and ~52% of the CIB, respectively. When
stacking 24 um sources, the inferred CIB lies within 1.1 sigma and 0.5 sigma
from direct measurements in the two bands, and fractions increase to 50% and
75%.Most of this resolved CIB fraction was radiated at z<=1.0, with 160 um
sources found at higher redshift than 100 um ones.