Normalized to: Battat, J.
[1]
oai:arXiv.org:1707.09431 [pdf] - 1586535
Measurement of directional range components of nuclear recoil tracks in
a fiducialised dark matter detector
Battat, J. B. R.;
Daw, E. J.;
Ezeribe, A. C.;
Gauvreau, J. -L.;
Harton, J. L.;
Lafler, R.;
Lee, E. R.;
Loomba, D.;
Lynch, W.;
Miller, E. H.;
Mouton, F.;
Paling, S.;
Phan, N.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Schuckman, F. G.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.
Submitted: 2017-07-28
We present results from the first measurement of axial range components of
fiducialized neutron induced nuclear recoil tracks using the DRIFT directional
dark matter detector. Nuclear recoil events are fiducialized in the DRIFT
experiment using temporal charge carrier separations between different species
of anions in 30:10:1 Torr of CS$_2$:CF$_4$:O$_2$ gas mixture. For this
measurement, neutron-induced nuclear recoil tracks were generated by exposing
the detector to $^{252}$Cf source from different directions. Using these
events, the sensitivity of the detector to the expected axial directional
signatures were investigated as the neutron source was moved from one detector
axis to another. Results obtained from these measurements show clear
sensitivity of the DRIFT detector to the axial directional signatures in this
fiducialization gas mode.
[3]
oai:arXiv.org:1707.00204 [pdf] - 1585390
Timing calibration of the APOLLO experiment
Submitted: 2017-07-01
The Apache Point Observatory Lunar Laser-ranging Operation (APOLLO) began
millimeter-precision ranging to the Moon in 2006. Until now, a comprehensive
validation of APOLLO system range accuracy has not been possible because of
centimeter-scale deficiencies in computational models of the Earth-Moon range,
and because APOLLO lacked an internal timing calibration system. Here, we
report on the development of a system that enables in-situ calibration of the
timing response of the APOLLO apparatus, simultaneous with lunar range
measurements. The system was installed in August 2016. Preliminary results show
that the APOLLO system can provide lunar range measurements with millimeter
accuracy.
[4]
oai:arXiv.org:1706.09550 [pdf] - 1598075
An absolute calibration system for millimeter-accuracy APOLLO
measurements
Adelberger, E. G.;
Battat, J. B. R.;
Birkmeier, K. J.;
Colmenares, N. R.;
Davis, R.;
Hoyle, C. D.;
Huang, L. R.;
McMillan, R. J.;
Murphy, T. W.;
Schlerman, E.;
Skrobol, C.;
Stubbs, C. W.;
Zach, A.
Submitted: 2017-06-28
Lunar laser ranging provides a number of leading experimental tests of
gravitation -- important in our quest to unify General Relativity and the
Standard Model of physics. The Apache Point Observatory Lunar Laser-ranging
Operation (APOLLO) has for years achieved median range precision at the ~2 mm
level. Yet residuals in model-measurement comparisons are an order-of-magnitude
larger, raising the question of whether the ranging data are not nearly as
accurate as they are precise, or if the models are incomplete or
ill-conditioned. This paper describes a new absolute calibration system (ACS)
intended both as a tool for exposing and eliminating sources of systematic
error, and also as a means to directly calibrate ranging data in-situ. The
system consists of a high-repetition-rate (80 MHz) laser emitting short (< 10
ps) pulses that are locked to a cesium clock. In essence, the ACS delivers
photons to the APOLLO detector at exquisitely well-defined time intervals as a
"truth" input against which APOLLO's timing performance may be judged and
corrected. Preliminary analysis indicates no inaccuracies in APOLLO data beyond
the ~3 mm level, suggesting that historical APOLLO data are of high quality and
motivating continued work on model capabilities. The ACS provides the means to
deliver APOLLO data both accurate and precise below the 2 mm level.
[5]
oai:arXiv.org:1706.09421 [pdf] - 1598072
APOLLO clock performance and normal point corrections
Submitted: 2017-06-28
The Apache Point Observatory Lunar Laser-ranging Operation (APOLLO) has
produced a large volume of high-quality lunar laser ranging (LLR) data since it
began operating in 2006. For most of this period, APOLLO has relied on a
GPS-disciplined, high-stability quartz oscillator as its frequency and time
standard. The recent addition of a cesium clock as part of a timing calibration
system initiated a comparison campaign between the two clocks. This has allowed
correction of APOLLO range measurements--called normal points--during the
overlap period, but also revealed a mechanism to correct for systematic range
offsets due to clock errors in historical APOLLO data. Drift of the GPS clock
on ~1000 s timescales contributed typically 2.5 mm of range error to APOLLO
measurements, and we find that this may be reduced to ~1.6 mm on average. We
present here a characterization of APOLLO clock errors, the method by which we
correct historical data, and the resulting statistics.
[6]
oai:arXiv.org:1701.00171 [pdf] - 1564000
Low Threshold Results and Limits from the DRIFT Directional Dark Matter
Detector
Battat, J. B. R.;
Ezeribe, A. C.;
Gauvreau, J. -L.;
Harton, J. L.;
Lafler, R.;
Law, E.;
Lee, E. R.;
Loomba, D.;
Lumnah, A.;
Miller, E. H.;
Monte, A.;
Mouton, F.;
Paling, S. M.;
Phan, N. S.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Schuckman, F. G.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Waldram, N.
Submitted: 2016-12-31, last modified: 2017-03-27
We present results from a 54.7 live-day shielded run of the DRIFT-IId
detector, the world's most sensitive, directional, dark matter detector.
Several improvements were made relative to our previous work including a lower
threshold for detection, a more robust analysis and a tenfold improvement in
our gamma rejection factor. After analysis, no events remain in our fiducial
region leading to an exclusion curve for spin-dependent WIMP-proton
interactions which reaches 0.28 pb at 100 GeV/c^2 a fourfold improvement on our
previous work. We also present results from a 45.4 live-day unshielded run of
the DRIFT-IId detector during which 14 nuclear recoil-like events were
observed. We demonstrate that the observed nuclear recoil rate of 0.31+/-0.08
events per day is consistent with detection of ambient, fast neutrons emanating
from the walls of the Boulby Underground Science Facility.
[7]
oai:arXiv.org:1610.02396 [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Battat, J. B. R.;
Irastorza, I. G.;
Aleksandrov, A.;
Guler, M. Ali;
Asada, T.;
Baracchini, E.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Bouvier, J.;
Buonaura, A.;
Burdge, K.;
Cebrian, S.;
Colas, P.;
Consiglio, L.;
Dafni, T.;
D'Ambrosio, N.;
Deaconu, C.;
De Lellis, G.;
Descombes, T.;
Di Crescenzo, A.;
Di Marco, N.;
Druitt, G.;
Eggleston, R.;
Ferrer-Ribas, E.;
Fusayasu, T.;
Galan, J.;
Galati, G.;
Garcia, J. A.;
Garza, J. G.;
Gentile, V.;
Garcia-Sciveres, M.;
Giomataris, Y.;
Guerrero, N.;
Guillaudin, O.;
Harton, J.;
Hashimoto, T.;
Hedges, M. T.;
Iguaz, F.;
Ikeda, T.;
Jaegle, I.;
Kadyk, J. A.;
Katsuragawa, T.;
Komura, S.;
Kubo, H.;
Kuge, K.;
Lamblin, J.;
Lauria, A.;
Lee, E. R.;
Lewis, P.;
Leyton, M.;
Loomba, D.;
Lopez, J. P.;
Luzon, G.;
Mayet, F.;
Mirallas, H.;
Miuchi, K.;
Mizumoto, T.;
Mizumura, Y.;
Monacelli, P.;
Monroe, J.;
Montesi, M. C.;
Naka, T.;
Nakamura, K.;
Nishimura, H.;
Ochi, A.;
Papevangelou, T.;
Parker, J. D.;
Phan, N. S.;
Pupilli, F.;
Richer, J. P.;
Riffard, Q.;
Rosa, G.;
Santos, D.;
Sawano, T.;
Sekiya, H.;
Seong, I. S.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Taishaku, R.;
Takada, A.;
Takeda, A.;
Tanaka, M.;
Tanimori, T.;
Thorpe, T. N.;
Tioukov, V.;
Tomita, H.;
Umemoto, A.;
Vahsen, S. E.;
Yamaguchi, Y.;
Yoshimoto, M.;
Zayas, E.
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a
compelling but technologically challenging strategy to provide an unambiguous
signature of the detection of Galactic dark matter. Most directional detectors
aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas
or solid targets. The main challenge with directional detection is the need for
high spatial resolution over large volumes, which puts strong requirements on
the readout technologies. In this paper we review the various detector readout
technologies used by directional detectors. In particular, we summarize the
challenges, advantages and drawbacks of each approach, and discuss future
prospects for these technologies.
[8]
oai:arXiv.org:1602.03781 [pdf] - 1384743
A review of the discovery reach of directional Dark Matter detection
Mayet, F.;
Green, A. M.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Gelmini, G. B.;
Gondolo, P.;
Kavanagh, B. J.;
Lee, S. K.;
Loomba, D.;
Monroe, J.;
Morgan, B.;
O'Hare, C. A. J.;
Peter, A. H. G.;
Phan, N. S.;
Vahsen, S. E.
Submitted: 2016-02-11, last modified: 2016-03-17
Cosmological observations indicate that most of the matter in the Universe is
Dark Matter. Dark Matter in the form of Weakly Interacting Massive Particles
(WIMPs) can be detected directly, via its elastic scattering off target nuclei.
Most current direct detection experiments only measure the energy of the
recoiling nuclei. However, directional detection experiments are sensitive to
the direction of the nuclear recoil as well. Due to the Sun's motion with
respect to the Galactic rest frame, the directional recoil rate has a dipole
feature, peaking around the direction of the Solar motion. This provides a
powerful tool for demonstrating the Galactic origin of nuclear recoils and
hence unambiguously detecting Dark Matter. Furthermore, the directional recoil
distribution depends on the WIMP mass, scattering cross section and local
velocity distribution. Therefore, with a large number of recoil events it will
be possible to study the physics of Dark Matter in terms of particle and
astrophysical properties. We review the potential of directional detectors for
detecting and characterizing WIMPs.
[9]
oai:arXiv.org:1410.7821 [pdf] - 1250420
First background-free limit from a directional dark matter experiment:
results from a fully fiducialised DRIFT detector
Battat, J. B. R.;
Brack, J.;
Daw, E.;
Dorofeev, A.;
Ezeribe, A. C.;
Gauvreau, J. -L.;
Gold, M.;
Harton, J. L.;
Landers, J. M.;
Law, E.;
Lee, E. R.;
Loomba, D.;
Lumnah, A.;
Matthews, J. A. J.;
Miller, E. H.;
Monte, A.;
Mouton, F.;
Murphy, A. StJ.;
Paling, S. M.;
Phan, N.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Schuckman, F.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Telfer, S.;
Vahsen, S. E.;
Walker, D.;
Warner, D.;
Yuriev, L.
Submitted: 2014-10-28, last modified: 2015-07-23
The addition of O2 to gas mixtures in time projection chambers containing CS2
has recently been shown to produce multiple negative ions that travel at
slightly different velocities. This allows a measurement of the absolute
position of ionising events in the z (drift) direction. In this work, we apply
the z-fiducialisation technique to a directional dark matter search. In
particular, we present results from a 46.3 live-day source-free exposure of the
DRIFT-IId detector run in this completely new mode. With full-volume
fiducialisation, we have achieved the first background-free operation of a
directional detector. The resulting exclusion curve for spin-dependent
WIMP-proton interactions reaches 1.1 pb at 100 GeV/c2, a factor of 2 better
than our previous work. We describe the automated analysis used here, and argue
that detector upgrades, implemented after the acquisition of these data, will
bring an additional factor of >3 improvement in the near future.
[10]
oai:arXiv.org:1407.3938 [pdf] - 1215675
Radon in the DRIFT-II directional dark matter TPC: emanation, detection
and mitigation
Battat, J. B. R.;
Brack, J.;
Daw, E.;
Dorofeev, A.;
Ezeribe, A. C.;
Fox, J. R.;
Gauvreau, J. -L.;
Gold, M.;
Harmon, L. J.;
Harton, J. L.;
Landers, J. M.;
Lee, E. R.;
Loomba, D.;
Matthews, J. A. J.;
Miller, E. H.;
Monte, A.;
Murphy, A. StJ.;
Paling, S. M.;
Phan, N.;
Pipe, M.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Telfer, S.;
Walker, D.;
Warner, D.;
Yuriev, L.
Submitted: 2014-07-15, last modified: 2014-08-25
Radon gas emanating from materials is of interest in environmental science
and also a major concern in rare event non-accelerator particle physics
experiments such as dark matter and double beta decay searches, where it is a
major source of background. Notable for dark matter experiments is the
production of radon progeny recoils (RPRs), the low energy (~100 keV) recoils
of radon daughter isotopes, which can mimic the signal expected from WIMP
interactions. Presented here are results of measurements of radon emanation
from detector materials in the 1 metre cubed DRIFT-II directional dark matter
gas time projection chamber experiment. Construction and operation of a radon
emanation facility for this work is described, along with an analysis to
continuously monitor DRIFT data for the presence of internal 222Rn and 218Po.
Applying this analysis to historical DRIFT data, we show how systematic
substitution of detector materials for alternatives, selected by this device
for low radon emanation, has resulted in a factor of ~10 reduction in internal
radon rates. Levels are found to be consistent with the sum from separate radon
emanation measurements of the internal materials and also with direct
measurement using an attached alpha spectrometer. The current DRIFT detector,
DRIFT-IId, is found to have sensitivity to 222Rn of 2.5 {\mu}Bq/l with current
analysis efficiency, potentially opening up DRIFT technology as a new tool for
sensitive radon assay of materials.
[11]
oai:arXiv.org:1309.5389 [pdf] - 723101
Novel Probes of Gravity and Dark Energy
Jain, Bhuvnesh;
Joyce, Austin;
Thompson, Rodger;
Upadhye, Amol;
Battat, James;
Brax, Philippe;
Davis, Anne-Christine;
de Rham, Claudia;
Dodelson, Scott;
Erickcek, Adrienne;
Gabadadze, Gregory;
Hu, Wayne;
Hui, Lam;
Huterer, Dragan;
Kamionkowski, Marc;
Khoury, Justin;
Koyama, Kazuya;
Li, Baojiu;
Linder, Eric;
Schmidt, Fabian;
Scoccimarro, Roman;
Starkman, Glenn;
Stubbs, Chris;
Takada, Masahiro;
Tolley, Andrew;
Trodden, Mark;
Uzan, Jean-Philippe;
Vikram, Vinu;
Weltman, Amanda;
Wyman, Mark;
Zaritsky, Dennis;
Zhao, Gongbo
Submitted: 2013-09-20, last modified: 2013-09-24
The discovery of cosmic acceleration has stimulated theorists to consider
dark energy or modifications to Einstein's General Relativity as possible
explanations. The last decade has seen advances in theories that go beyond
smooth dark energy -- modified gravity and interactions of dark energy. While
the theoretical terrain is being actively explored, the generic presence of
fifth forces and dark sector couplings suggests a set of distinct observational
signatures. This report focuses on observations that differ from the
conventional probes that map the expansion history or large-scale structure.
Examples of such novel probes are: detection of scalar fields via lab
experiments, tests of modified gravity using stars and galaxies in the nearby
universe, comparison of lensing and dynamical masses of galaxies and clusters,
and the measurements of fundamental constants at high redshift. The
observational expertise involved is very broad as it spans laboratory
experiments, high resolution astronomical imaging and spectroscopy and radio
observations. In the coming decade, searches for these effects have the
potential for discovering fundamental new physics. We discuss how the searches
can be carried out using experiments that are already under way or with modest
adaptations of existing telescopes or planned experiments. The accompanying
paper on the Growth of Cosmic Structure describes complementary tests of
gravity with observations of large-scale structure.
[12]
oai:arXiv.org:1301.5685 [pdf] - 619558
Background Rejection in the DMTPC Dark Matter Search Using Charge
Signals
Lopez, J. P.;
Dujmic, D.;
Ahlen, S.;
Battat, J. B. R.;
Deaconu, C.;
Fisher, P.;
Henderson, S.;
Inglis, A.;
Kaboth, A.;
Monroe, J.;
Sciolla, G.;
Tomita, H.;
Wellenstein, H.;
Yamamoto, R.
Submitted: 2013-01-23, last modified: 2013-01-28
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing a
low pressure gas TPC for detecting Weakly Interacting Massive Particle
(WIMP)-nucleon interactions. Optical readout with CCD cameras allows for the
detection of the daily modulation of the direction of the dark matter wind. In
order to reach sensitivities required for WIMP detection, the detector needs to
minimize backgrounds from electron recoils. This paper demonstrates that a
simplified CCD analysis achieves $7.3\times10^{-5}$ rejection of electron
recoils while a charge analysis yields an electron rejection factor of
$3.3\times10^{-4}$ for events with $^{241}$Am-equivalent ionization energy loss
between 40 keV and 200 keV. A combined charge and CCD analysis yields a
background-limited upper limit of $1.1\times10^{-5}$ (90% confidence level) for
the rejection of $\gamma$ and electron events. Backgrounds from alpha decays
from the field cage are eliminated by introducing a veto electrode that
surrounds the sensitive region in the TPC. CCD-specific backgrounds are reduced
more than two orders of magnitude when requiring a coincidence with the charge
readout.
[13]
oai:arXiv.org:1109.3270 [pdf] - 1084108
Dark Matter Time Projection Chamber: Recent R&D Results
Battat, J. B. R.;
Ahlen, S.;
Chernicoff, M.;
Deaconu, C.;
Dujmic, D.;
Dushkin, A.;
Fisher, P.;
Henderson, S.;
Inglis, A.;
Kaboth, A.;
Kirsch, L.;
Lopez, J. P.;
Monroe, J.;
Ouyang, H.;
Sciolla, G.;
Tomita, H.;
Wellenstein, H.
Submitted: 2011-09-15, last modified: 2011-09-18
The Dark Matter Time Projection Chamber collaboration recently reported a
dark matter limit obtained with a 10 liter time projection chamber filled with
CF4 gas. The 10 liter detector was capable of 2D tracking (perpendicular to the
drift direction) and 2D fiducialization, and only used information from two CCD
cameras when identifying tracks and rejecting backgrounds. Since that time, the
collaboration has explored the potential benefits of photomultiplier tube and
electronic charge readout to achieve 3D tracking, and particle identification
for background rejection. The latest results of this effort is described here.
[14]
oai:arXiv.org:1109.3501 [pdf] - 1084146
Background Rejection in the DMTPC Dark Matter Search Using Charge
Signals
Lopez, J. P.;
Ahlen, S.;
Battat, J.;
Caldwell, T.;
Chernicoff, M.;
Deaconu, C.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Fisher, P.;
Golub, F.;
Henderson, S.;
Inglis, A.;
Kaboth, A.;
Kohse, G.;
Kirsch, L.;
Lanza, R.;
Lee, A.;
Monroe, J.;
Ouyang, H.;
Sahin, T.;
Sciolla, G.;
Skvorodnev, N.;
Tomita, H.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R.;
Yegoryan, H.
Submitted: 2011-09-15
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing
low-pressure gas TPC detectors for measuring WIMP-nucleon interactions. Optical
readout with CCD cameras allows for the detection for the daily modulation in
the direction of the dark matter wind, while several charge readout channels
allow for the measurement of additional recoil properties. In this article, we
show that the addition of the charge readout analysis to the CCD allows us too
obtain a statistics-limited 90% C.L. upper limit on the $e^-$ rejection factor
of $5.6\times10^{-6}$ for recoils with energies between 40 and 200
keV$_{\mathrm{ee}}$. In addition, requiring coincidence between charge signals
and light in the CCD reduces CCD-specific backgrounds by more than two orders
of magnitude.
[15]
oai:arXiv.org:1012.3912 [pdf] - 280381
DMTPC: Dark matter detection with directional sensitivity
Battat, J. B. R.;
Ahlen, S.;
Caldwell, T.;
Deaconu, C.;
Dujmic, D.;
Fedus, W.;
Fisher, P.;
Golub, F.;
Henderson, S.;
Inglis, A.;
Kaboth, A.;
Kohse, G.;
Lanza, R.;
Lee, A.;
Lopez, J.;
Monroe, J.;
Sahin, T.;
Sciolla, G.;
Skvorodnev, N.;
Tomita, H.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R.;
Yegoryan, H.
Submitted: 2010-12-17
The Dark Matter Time Projection Chamber (DMTPC) experiment uses CF_4 gas at
low pressure (0.1 atm) to search for the directional signature of Galactic WIMP
dark matter. We describe the DMTPC apparatus and summarize recent results from
a 35.7 g-day exposure surface run at MIT. After nuclear recoil cuts are applied
to the data, we find 105 candidate events in the energy range 80 - 200 keV,
which is consistent with the expected cosmogenic neutron background. Using this
data, we obtain a limit on the spin-dependent WIMP-proton cross-section of 2.0
\times 10^{-33} cm^2 at a WIMP mass of 115 GeV/c^2. This detector is currently
deployed underground at the Waste Isolation Pilot Plant in New Mexico.
[16]
oai:arXiv.org:1006.2928 [pdf] - 377201
First Dark Matter Search Results from a Surface Run of the 10-L DMTPC
Directional Dark Matter Detector
Ahlen, S.;
Battat, J. B. R.;
Caldwell, T.;
Deaconu, C.;
Dujmic, D.;
Fedus, W.;
Fisher, P.;
Golub, F.;
Henderson, S.;
Inglis, A.;
Kaboth, A.;
Kohse, G.;
Lanza, R.;
Lee, A.;
Lopez, J.;
Monroe, J.;
Sahin, T.;
Sciolla, G.;
Skvorodnev, N.;
Tomita, H.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R.;
Yegoryan, H.
Submitted: 2010-06-15, last modified: 2010-12-09
The Dark Matter Time Projection Chamber (DMTPC) is a low pressure (75 Torr
CF4) 10 liter detector capable of measuring the vector direction of nuclear
recoils with the goal of directional dark matter detection. In this paper we
present the first dark matter limit from DMTPC. In an analysis window of 80-200
keV recoil energy, based on a 35.7 g-day exposure, we set a 90% C.L. upper
limit on the spin-dependent WIMP-proton cross section of 2.0 x 10^{-33} cm^{2}
for 115 GeV/c^2 dark matter particle mass.
[17]
oai:arXiv.org:1009.5720 [pdf] - 723020
Laser Ranging to the Lost Lunokhod~1 Reflector
Submitted: 2010-09-28, last modified: 2010-11-04
In 1970, the Soviet Lunokhod 1 rover delivered a French-built laser reflector
to the Moon. Although a few range measurements were made within three months of
its landing, these measurements---and any that may have followed---are
unpublished and unavailable. The Lunokhod 1 reflector was, therefore,
effectively lost until March of 2010 when images from the Lunar Reconnaissance
Orbiter (LRO) provided a positive identification of the rover and determined
its coordinates with uncertainties of about 100 m. This allowed the Apache
Point Observatory Lunar Laser-ranging Operation (APOLLO) to quickly acquire a
laser signal. The reflector appears to be in excellent condition, delivering a
signal roughly four times stronger than its twin reflector on the Lunokhod 2
rover. The Lunokhod 1 reflector is especially valuable for science because it
is closer to the Moon's limb than any of the other reflectors and, unlike the
Lunokhod 2 reflector, we find that it is usable during the lunar day. We report
the selenographic position of the reflector to few-centimeter accuracy, comment
on the health of the reflector, and illustrate the value of this reflector for
achieving science goals.
[18]
oai:arXiv.org:1003.0713 [pdf] - 723018
Long-term degradation of optical devices on the moon
Murphy,, T. W.;
Adelberger, E. G.;
Battat, J. B. R.;
Hoyle, C. D.;
McMillan, R. J.;
Michelsen, E. L.;
Samad, R.;
Stubbs, C. W.;
Swanson, H. E.
Submitted: 2010-03-02
Forty years ago, Apollo astronauts placed the first of several retroreflector
arrays on the lunar surface. Their continued usefulness for laser-ranging might
suggest that the lunar environment does not damage optical devices. However,
new laser ranging data reveal that the efficiency of the three Apollo reflector
arrays is now diminished by a factor of ten at all lunar phases and by an
additional factor of ten when the lunar phase is near full moon. These deficits
did not exist in the earliest years of lunar ranging, indicating that the lunar
environment damages optical equipment on the timescale of decades. Dust or
abrasion on the front faces of the corner-cube prisms may be responsible,
reducing their reflectivity and degrading their thermal performance when
exposed to face-on sunlight at full moon. These mechanisms can be tested using
laboratory simulations and must be understood before designing equipment
destined for the moon.
[19]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.
[20]
oai:arXiv.org:0908.3343 [pdf] - 27556
Satellite-Mounted Light Sources as Photometric Calibration Standards
Submitted: 2009-08-23
A significant and growing portion of systematic error on a number of
fundamental parameters in astrophysics and cosmology is due to uncertainties
from absolute photometric and flux standards. A path toward achieving major
reduction in such uncertainties may be provided by satellite-mounted light
sources, resulting in improvement in the ability to precisely characterize
atmospheric extinction, and thus helping to usher in the coming generation of
precision results in astronomy. Toward this end, we have performed a campaign
of observations of the 532 nm pulsed laser aboard the CALIPSO satellite, using
a portable network of cameras and photodiodes, to precisely measure atmospheric
extinction.
[21]
oai:arXiv.org:0907.0675 [pdf] - 151008
DMTPC: A dark matter detector with directional sensitivity
Battat, J. B. R.;
Ahlen, S.;
Caldwell, T.;
Dujmic, D.;
Dushkin, A.;
Fisher, P.;
Golub, F.;
Goyal, S.;
Henderson, S.;
Inglis, A.;
Lanza, R.;
Lopez, J.;
Kaboth, A.;
Kohse, G.;
Monroe, J.;
Sciolla, G.;
Skvorodnev, B. N.;
Tomita, H.;
Vanderspek, R.;
Wellenstein, H.;
Yamamoto, R.
Submitted: 2009-07-03
By correlating nuclear recoil directions with the Earth's direction of motion
through the Galaxy, a directional dark matter detector can unambiguously detect
Weakly Interacting Massive Particles (WIMPs), even in the presence of
backgrounds. Here, we describe the Dark Matter Time-Projection Chamber (DMTPC)
detector, a TPC filled with CF4 gas at low pressure (0.1 atm). Using this
detector, we have measured the vector direction (head-tail) of nuclear recoils
down to energies of 100 keV with an angular resolution of <15 degrees. To study
our detector backgrounds, we have operated in a basement laboratory on the MIT
campus for several months. We are currently building a new, high-radiopurity
detector for deployment underground at the Waste Isolation Pilot Plant facility
in New Mexico.
[22]
oai:arXiv.org:0903.3895 [pdf] - 22632
The DMTPC project
Sciolla, G.;
Battat, J.;
Caldwell, T.;
Dujmic, D.;
Fisher, P.;
Henderson, S.;
Lanza, R.;
Lee, A.;
Lopez, J.;
Kaboth, A.;
Kohse, G.;
Monroe, J.;
Sahin, T.;
Sciolla, G.;
Yamamoto, R.;
Yegoryan, H.;
Ahlen, S.;
Otis, K.;
Tomita, H.;
Dushkin, A.;
Wellenstein, H.
Submitted: 2009-03-23
The DMTPC detector is a low-pressure CF4 TPC with optical readout for
directional detection of Dark Matter. The combination of the energy and
directional tracking information allows for an efficient suppression of all
backgrounds. The choice of gas (CF4) makes this detector particularly sensitive
to spin-dependent interactions.
[23]
oai:arXiv.org:0811.2922 [pdf] - 121221
The DMTPC detector
Sciolla, G.;
Battat, J.;
Caldwell, T.;
Cornell, B.;
Dujmic, D.;
Fisher, P.;
Henderson, S.;
Lanza, R.;
Lee, A.;
Lopez, J.;
Kaboth, A.;
Kohse, G.;
Monroe, J.;
Sahin, T.;
Vanderspek, R.;
Yamamoto, R.;
Yegoryan, H.;
Ahlen, S.;
Avery, D.;
Otis, K.;
Roccaro, A.;
Tomita, H.;
Dushkin, A.;
Wellenstein, H.
Submitted: 2008-11-18
Directional detection of Dark Matter allows for unambiguous direct detection
of WIMPs as well as discrimination between various Dark Matter models in our
galaxy. The DMTPC detector is a low-pressure TPC with optical readout designed
for directional direct detection of WIMPs. By using CF4 gas as the active
material, the detector also has excellent sensitivity to spin-dependent
interactions of Dark Matter on protons.
[24]
oai:arXiv.org:0810.0291 [pdf] - 16990
DMTPC: a new apparatus for directional detection of Dark Matter
Sciolla, G.;
Lee, A.;
Battat, J.;
Caldwell, T.;
Cornell, B.;
Dujmic, D.;
Fisher, P.;
Henderson, S.;
Lanza, R.;
Lopez, J.;
Kaboth, A.;
Kohse, G.;
Monroe, J.;
Sahin, T.;
Vanderspek, R .;
Yamamoto, R.;
Yegoryan, H.;
Alhen, S.;
Avery, D.;
Otis, K.;
Roccaro, A.;
Tomita, H.;
Dushkin, A.;
Wellenstein, H.
Submitted: 2008-10-01
Directional detection of Dark Matter allows for unambiguous direct detection
of WIMPs as well as discrimination between various Dark Matter models in our
galaxy. The DMTPC detector is a low-pressure TPC with optical readout designed
for directional direct detection of WIMPs. By using CF4 gas as the active
material, the detector also has excellent sensitivity to spin-dependent
interactions of Dark Matter on protons.
[25]
oai:arXiv.org:0805.4466 [pdf] - 13042
Solar system constraints on the Dvali-Gabadadze-Porrati braneworld
theory of gravity
Submitted: 2008-05-28
A number of proposals have been put forward to account for the observed
accelerating expansion of the Universe through modifications of gravity. One
specific scenario, Dvali-Gabadadze-Porrati (DGP) gravity, gives rise to a
potentially observable anomaly in the solar system: all planets would exhibit a
common anomalous precession, dw/dt, in excess of the prediction of General
Relativity. We have used the Planetary Ephemeris Program (PEP) along with
planetary radar and radio tracking data to set a constraint of |dw/dt| < 0.02
arcseconds per century on the presence of any such common precession. This
sensitivity falls short of that needed to detect the estimated universal
precession of |dw/dt| = 5e-4 arcseconds per century expected in the DGP
scenario. We discuss the fact that ranging data between objects that orbit in a
common plane cannot constrain the DGP scenario. It is only through the relative
inclinations of the planetary orbital planes that solar system ranging data
have sensitivity to the DGP-like effect of universal precession. In addition,
we illustrate the importance of performing a numerical evaluation of the
sensitivity of the data set and model to any perturbative precession.
[26]
oai:arXiv.org:0710.0890 [pdf] - 554023
APOLLO: the Apache Point Observatory Lunar Laser-ranging Operation:
Instrument Description and First Detections
Murphy,, T. W.;
Adelberger, E. G.;
Battat, J. B. R.;
Carey, L. N.;
Hoyle, C. D.;
LeBlanc, P.;
Michelsen, E. L.;
Nordtvedt, K.;
Orin, A. E.;
Strasburg, J. D.;
Stubbs, C. W.;
Swanson, H. E.;
Williams, E.
Submitted: 2007-10-03, last modified: 2007-11-07
A next-generation lunar laser ranging apparatus using the 3.5 m telescope at
the Apache Point Observatory in southern New Mexico has begun science
operation. APOLLO (the Apache Point Observatory Lunar Laser-ranging Operation)
has achieved one-millimeter range precision to the moon which should lead to
approximately one-order-of-magnitude improvements in the precision of several
tests of fundamental properties of gravity. We briefly motivate the scientific
goals, and then give a detailed discussion of the APOLLO instrumentation.
[27]
oai:arXiv.org:0710.0694 [pdf] - 1516212
Gain Stabilization of a Submillimeter SIS Heterodyne Receiver
Submitted: 2007-10-02
We have designed a system to stabilize the gain of a submillimeter heterodyne
receiver against thermal fluctuations of the mixing element. In the most
sensitive heterodyne receivers, the mixer is usually cooled to 4 K using a
closed-cycle cryocooler, which can introduce ~1% fluctuations in the physical
temperature of the receiver components. We compensate for the resulting mixer
conversion gain fluctuations by monitoring the physical temperature of the
mixer and adjusting the gain of the intermediate frequency (IF) amplifier that
immediately follows the mixer. This IF power stabilization scheme, developed
for use at the Submillimeter Array (SMA), a submillimeter interferometer
telescope on Mauna Kea in Hawaii, routinely achieves a receiver gain stability
of 1 part in 6,000 (rms to mean). This is an order of magnitude improvement
over the typical uncorrected stability of 1 part in a few hundred. Our gain
stabilization scheme is a useful addition to SIS heterodyne receivers that are
cooled using closed-cycle cryocoolers in which the 4 K temperature fluctuations
tend to be the leading cause of IF power fluctuations.
[28]
oai:arXiv.org:0710.0701 [pdf] - 1510173
The First Lunar Ranging Constraints on Gravity Sector SME Parameters
Submitted: 2007-10-02
We present the first constraints on pure-gravity sector Standard-Model
Extension (SME) parameters using Lunar Laser Ranging (LLR). LLR measures the
round trip travel time of light between the Earth and the Moon. With 34+ years
of LLR data, we have constrained six independent linear combinations of SME
parameters at the level of $10^{-6}$ to $10^{-11}$. There is no evidence for
Lorentz violation in the LLR dataset.
[29]
oai:arXiv.org:0710.0702 [pdf] - 5618
Testing for Lorentz Violation: Constraints on Standard-Model Extension
Parameters via Lunar Laser Ranging
Submitted: 2007-10-02
We present constraints on violations of Lorentz Invariance based on Lunar
Laser Ranging (LLR) data. LLR measures the Earth-Moon separation by timing the
round-trip travel of light between the two bodies, and is currently accurate to
a few centimeters (parts in $10^{11}$ of the total distance). By analyzing
archival LLR data under the Standard-Model Extension (SME) framework, we
derived six observational constraints on dimensionless SME parameters that
describe potential Lorentz-violation. We found no evidence for Lorentz
violation at the $10^{-6}$ to $10^{-11}$ level in these parameters.
[30]
oai:arXiv.org:astro-ph/0405530 [pdf] - 65050
A map of OMC-1 in CO 9-8
Marrone, D. P.;
Battat, J.;
Bensch, F.;
Blundell, R.;
Diaz, M.;
Gibson, H.;
Hunter, T.;
Meledin, D.;
Paine, S.;
Papa, D. C.;
Radford, S. J. E.;
Smith, M.;
Tong, E.
Submitted: 2004-05-26, last modified: 2004-09-06
The distribution of 12C16O J=9-8 (1.037 THz) emission has been mapped in
OMC-1 at 35 points with 84" resolution. This is the first map of this source in
this transition and only the second velocity-resolved ground-based observation
of a line in the terahertz frequency band. There is emission present at all
points in the map, a region roughly 4' by 6' in size, with peak antenna
temperature dropping only near the edges. Away from the Orion KL outflow, the
velocity structure suggests that most of the emission comes from the OMC-1
photon-dominated region, with a typical linewidthof 3-6 km/s. Large velocity
gradient modeling of the emission in J=9-8 and six lower transitions suggests
that the lines originate in regions with temperatures around 120 K and
densities of at least 10^(3.5) cm^(-3) near theta^(1) C Ori and at the Orion
Bar, and from 70 K gas at around 10^(4) cm^(-3) southeast and west of the bar.
These observations are among the first made with the 0.8 m Smithsonian
Astrophysical Observatory Receiver Lab Telescope, a new instrument designed to
observe at frequencies above 1 THz from an extremely high and dry site in
northern Chile.
[31]
oai:arXiv.org:astro-ph/0407142 [pdf] - 65984
Atmospheric Phase Correction Using Total Power Radiometry at the
Submillimeter Array
Submitted: 2004-07-07
Phase noise caused by an inhomogeneous, time-variable water vapor
distribution in our atmosphere reduces the angular resolution, visibility
amplitude and coherence time of millimeter and submillimeter wavelength
interferometers. We present early results from our total power radiometry phase
correction experiment carried out with the Submillimeter Array on Mauna Kea.
From accurate measurements of the atmospheric emission along the lines of
sight of two elements of the array, we estimated the differential atmospheric
electrical path between them. In one test, presented here, the phase correction
technique reduced the rms phase noise at 230 GHz from 72$\degr$ to 27$\degr$
over a 20 minute period with a 2.5 second integration time. This corresponds to
a residual differential electrical path of 98 $\mu$m, or 15 $\mu$m of
precipitable water vapor, and raises the coherence in the 20 minute period from
0.45 to 0.9.
[32]
oai:arXiv.org:astro-ph/0403524 [pdf] - 63715
Mapping the Outflow from G5.89-0.39 in SiO(5-4)
Sollins, P. K.;
Hunter, T. R.;
Battat, J.;
Beuther, H.;
Ho, P. T. P.;
Lim, J.;
Liu, S. Y.;
Ohashi, N.;
Sridharan, T. K.;
Su, Y. N.;
Zhao, J. -H.;
Zhang, Q.
Submitted: 2004-03-22
We have mapped the ultracompact HII region, G5.89-0.39, and its molecular
surroundings with the Submillimeter Array at 2".8 x 1".8 angular resolution in
1.3 mm continuum, SiO(5-4), and eight other molecular lines. We have resolved
for the first time the highly energetic molecular outflow in this region. At
this resolution, the outflow is definitely bipolar and appears to originate in
a 1.3 mm continuum source. The continuum source peaks in the center of the HII
region. The axis of the outflow lines up with a recently discovered O5V star.