Normalized to: Basso, S.
[1]
oai:arXiv.org:1906.05648 [pdf] - 2007228
Thin glass shells for active optics for future space telescopes
Submitted: 2019-06-13
We present a method for the manufacturing of thin shells of glass, which
appears promising for the development of active optics for future space
telescopes. The method exploits the synergy of different mature technologies,
while leveraging the commercial availability of large, high-quality sheets of
glass, with thickness up to few millimeters. The first step of the method
foresees the pre-shaping of flat substrates of glass by replicating the
accurate shape of a mold via hot slumping technology. The replication concept
is advantageous for making large optics composed of many identical or similar
segments. After the hot slumping, the shape error residual on the optical
surface is addressed by applying a deterministic sub-aperture technology as
computer-controlled bonnet polishing and/or ion beam figuring. Here we focus on
the bonnet polishing case, during which the thin, deformable substrate of glass
is temporary stiffened by a removable holder. In this paper, we report on the
results so far achieved on a 130 mm glass shell case study.
[2]
oai:arXiv.org:1812.04020 [pdf] - 1795995
The enhanced X-ray Timing and Polarimetry mission - eXTP
Zhang, ShuangNan;
Santangelo, Andrea;
Feroci, Marco;
Xu, YuPeng;
Lu, FangJun;
Chen, Yong;
Feng, Hua;
Zhang, Shu;
Brandt, Søren;
Hernanz, Margarita;
Baldini, Luca;
Bozzo, Enrico;
Campana, Riccardo;
De Rosa, Alessandra;
Dong, YongWei;
Evangelista, Yuri;
Karas, Vladimir;
Meidinger, Norbert;
Meuris, Aline;
Nandra, Kirpal;
Pan, Teng;
Pareschi, Giovanni;
Orleanski, Piotr;
Huang, QiuShi;
Schanne, Stephane;
Sironi, Giorgia;
Spiga, Daniele;
Svoboda, Jiri;
Tagliaferri, Gianpiero;
Tenzer, Christoph;
Vacchi, Andrea;
Zane, Silvia;
Walton, Dave;
Wang, ZhanShan;
Winter, Berend;
Wu, Xin;
Zand, Jean J. M. in 't;
Ahangarianabhari, Mahdi;
Ambrosi, Giovanni;
Ambrosino, Filippo;
Barbera, Marco;
Basso, Stefano;
Bayer, Jörg;
Bellazzini, Ronaldo;
Bellutti, Pierluigi;
Bertucci, Bruna;
Bertuccio, Giuseppe;
Borghi, Giacomo;
Cao, XueLei;
Cadoux, Franck;
Campana, Riccardo;
Ceraudo, Francesco;
Chen, TianXiang;
Chen, YuPeng;
Chevenez, Jerome;
Civitani, Marta;
Cui, Wei;
Cui, WeiWei;
Dauser, Thomas;
Del Monte, Ettore;
Di Cosimo, Sergio;
Diebold, Sebastian;
Doroshenko, Victor;
Dovciak, Michal;
Du, YuanYuan;
Ducci, Lorenzo;
Fan, QingMei;
Favre, Yannick;
Fuschino, Fabio;
Gálvez, José Luis;
Gao, Min;
Ge, MingYu;
Gevin, Olivier;
Grassi, Marco;
Gu, QuanYing;
Gu, YuDong;
Han, DaWei;
Hong, Bin;
Hu, Wei;
Ji, Long;
Jia, ShuMei;
Jiang, WeiChun;
Kennedy, Thomas;
Kreykenbohm, Ingo;
Kuvvetli, Irfan;
Labanti, Claudio;
Latronico, Luca;
Li, Gang;
Li, MaoShun;
Li, Xian;
Li, Wei;
Li, ZhengWei;
Limousin, Olivier;
Liu, HongWei;
Liu, XiaoJing;
Lu, Bo;
Luo, Tao;
Macera, Daniele;
Malcovati, Piero;
Martindale, Adrian;
Michalska, Malgorzata;
Meng, Bin;
Minuti, Massimo;
Morbidini, Alfredo;
Muleri, Fabio;
Paltani, Stephane;
Perinati, Emanuele;
Picciotto, Antonino;
Piemonte, Claudio;
Qu, JinLu;
Rachevski, Alexandre;
Rashevskaya, Irina;
Rodriguez, Jerome;
Schanz, Thomas;
Shen, ZhengXiang;
Sheng, LiZhi;
Song, JiangBo;
Song, LiMing;
Sgro, Carmelo;
Sun, Liang;
Tan, Ying;
Uttley, Phil;
Wang, Juan;
Wang, LangPing;
Wang, YuSa;
Watts, Anna L.;
Wen, XiangYang;
Wilms, Jörn;
Xiong, ShaoLin;
Yang, JiaWei;
Yang, Sheng;
Yang, YanJi;
Yu, Nian;
Zhang, WenDa;
Zampa, Gianluigi;
Zampa, Nicola;
Zdziarski, Andrzej A.;
Zhang, AiMei;
Zhang, ChengMo;
Zhang, Fan;
Zhang, Long;
Zhang, Tong;
Zhang, Yi;
Zhang, XiaoLi;
Zhang, ZiLiang;
Zhao, BaoSheng;
Zheng, ShiJie;
Zhou, YuPeng;
Zorzi, Nicola;
Zwart, J. Frans
Submitted: 2018-12-10
In this paper we present the enhanced X-ray Timing and Polarimetry mission -
eXTP. eXTP is a space science mission designed to study fundamental physics
under extreme conditions of density, gravity and magnetism. The mission aims at
determining the equation of state of matter at supra-nuclear density, measuring
effects of QED, and understanding the dynamics of matter in strong-field
gravity. In addition to investigating fundamental physics, eXTP will be a very
powerful observatory for astrophysics that will provide observations of
unprecedented quality on a variety of galactic and extragalactic objects. In
particular, its wide field monitoring capabilities will be highly instrumental
to detect the electro-magnetic counterparts of gravitational wave sources. The
paper provides a detailed description of: (1) the technological and technical
aspects, and the expected performance of the instruments of the scientific
payload; (2) the elements and functions of the mission, from the spacecraft to
the ground segment.
[4]
oai:arXiv.org:1610.00272 [pdf] - 1490021
Manufacturing and testing a thin glass mirror shell with piezoelectric
active control
Spiga, D.;
Barbera, M.;
Collura, A.;
Basso, S.;
Candia, R.;
Civitani, M.;
Di Bella, M.;
Di Cicca, G.;
Cicero, U. Lo;
Lullo, G.;
Pelliciari, C.;
Riva, M.;
Salmaso, B.;
Sciortino, L.;
Varisco, S.
Submitted: 2016-10-02
Optics for future X-ray telescopes will be characterized by very large
aperture and focal length, and will be made of lightweight materials like glass
or silicon in order to keep the total mass within acceptable limits. Optical
modules based on thin slumped glass foils are being developed at various
institutes, aiming at improving the angular resolution to a few arcsec HEW.
Thin mirrors are prone to deform, so they require a careful integration to
avoid deformations and even correct forming errors. On the other hand, this
offers the opportunity to actively correct the residual deformation: a viable
possibility to improve the mirror figure is the application of piezoelectric
actuators onto the non-optical side of the mirrors, and several groups are
already at work on this approach. The concept we are developing consists of
actively integrating thin glass foils with piezoelectric patches, fed by
voltages driven by the feedback provided by X-rays. The actuators are
commercial components, while the tension signals are carried by a printed
circuit obtained by photolithography, and the driving electronic is a
multi-channel low power consumption voltage supply developed in-house. Finally,
the shape detection and the consequent voltage signal to be provided to the
piezoelectric array are determined in X-rays, in intra-focal setup at the XACT
facility at INAF/OAPA. In this work, we describe the manufacturing steps to
obtain a first active mirror prototype and the very first test performed in
X-rays.
[5]
oai:arXiv.org:1607.08823 [pdf] - 2064188
eXTP -- enhanced X-ray Timing and Polarimetry Mission
Zhang, S. N.;
Feroci, M.;
Santangelo, A.;
Dong, Y. W.;
Feng, H.;
Lu, F. J.;
Nandra, K.;
Wang, Z. S.;
Zhang, S.;
Bozzo, E.;
Brandt, S.;
De Rosa, A.;
Gou, L. J.;
Hernanz, M.;
van der Klis, M.;
Li, X. D.;
Liu, Y.;
Orleanski, P.;
Pareschi, G.;
Pohl, M.;
Poutanen, J.;
Qu, J. L.;
Schanne, S.;
Stella, L.;
Uttley, P.;
Watts, A.;
Xu, R. X.;
Yu, W. F.;
Zand, J. J. M. in 't;
Zane, S.;
Alvarez, L.;
Amati, L.;
Baldini, L.;
Bambi, C.;
Basso, S.;
Bhattacharyya, S.;
Bellazzini, R.;
Belloni, T.;
Bellutti, P.;
Bianchi, S.;
Brez, A.;
Bursa, M.;
Burwitz, V.;
Budtz-Jorgensen, C.;
Caiazzo, I.;
Campana, R.;
Cao, X. L.;
Casella, P.;
Chen, C. Y.;
Chen, L.;
Chen, T. X.;
Chen, Y.;
Chen, Y.;
Chen, Y. P.;
Civitani, M.;
Zelati, F. Coti;
Cui, W.;
Cui, W. W.;
Dai, Z. G.;
Del Monte, E.;
De Martino, D.;
Di Cosimo, S.;
Diebold, S.;
Dovciak, M.;
Donnarumma, I.;
Doroshenko, V.;
Esposito, P.;
Evangelista, Y.;
Favre, Y.;
Friedrich, P.;
Fuschino, F.;
Galvez, J. L.;
Gao, Z. L.;
Ge, M. Y.;
Gevin, O.;
Goetz, D.;
Han, D. W.;
Heyl, J.;
Horak, J.;
Hu, W.;
Huang, F.;
Huang, Q. S.;
Hudec, R.;
Huppenkothen, D.;
Israel, G. L.;
Ingram, A.;
Karas, V.;
Karelin, D.;
Jenke, P. A.;
Ji, L.;
Kennedy, T.;
Korpela, S.;
Kunneriath, D.;
Labanti, C.;
Li, G.;
Li, X.;
Li, Z. S.;
Liang, E. W.;
Limousin, O.;
Lin, L.;
Ling, Z. X.;
Liu, H. B.;
Liu, H. W.;
Liu, Z.;
Lu, B.;
Lund, N.;
Lai, D.;
Luo, B.;
Luo, T.;
Ma, B.;
Mahmoodifar, S.;
Marisaldi, M.;
Martindale, A.;
Meidinger, N.;
Men, Y. P.;
Michalska, M.;
Mignani, R.;
Minuti, M.;
Motta, S.;
Muleri, F.;
Neilsen, J.;
Orlandini, M.;
Pan, A T.;
Patruno, A.;
Perinati, E.;
Picciotto, A.;
Piemonte, C.;
Pinchera, M.;
Rachevski, A.;
Rapisarda, M.;
Rea, N.;
Rossi, E. M. R.;
Rubini, A.;
Sala, G.;
Shu, X. W.;
Sgro, C.;
Shen, Z. X.;
Soffitta, P.;
Song, L. M.;
Spandre, G.;
Stratta, G.;
Strohmayer, T. E.;
Sun, L.;
Svoboda, J.;
Tagliaferri, G.;
Tenzer, C.;
Tong, H.;
Taverna, R.;
Torok, G.;
Turolla, R.;
Vacchi, A.;
Wang, J.;
Wang, J. X.;
Walton, D.;
Wang, K.;
Wang, J. F.;
Wang, R. J.;
Wang, Y. F.;
Weng, S. S.;
Wilms, J.;
Winter, B.;
Wu, X.;
Wu, X. F.;
Xiong, S. L.;
Xu, Y. P.;
Xue, Y. Q.;
Yan, Z.;
Yang, S.;
Yang, X.;
Yang, Y. J.;
Yuan, F.;
Yuan, W. M.;
Yuan, Y. F.;
Zampa, G.;
Zampa, N.;
Zdziarski, A.;
Zhang, C.;
Zhang, C. L.;
Zhang, L.;
Zhang, X.;
Zhang, Z.;
Zhang, W. D.;
Zheng, S. J.;
Zhou, P.;
Zhou, X. L.
Submitted: 2016-07-29
eXTP is a science mission designed to study the state of matter under extreme
conditions of density, gravity and magnetism. Primary targets include isolated
and binary neutron stars, strong magnetic field systems like magnetars, and
stellar-mass and supermassive black holes. The mission carries a unique and
unprecedented suite of state-of-the-art scientific instruments enabling for the
first time ever the simultaneous spectral-timing-polarimetry studies of cosmic
sources in the energy range from 0.5-30 keV (and beyond). Key elements of the
payload are: the Spectroscopic Focusing Array (SFA) - a set of 11 X-ray optics
for a total effective area of about 0.9 m^2 and 0.6 m^2 at 2 keV and 6 keV
respectively, equipped with Silicon Drift Detectors offering <180 eV spectral
resolution; the Large Area Detector (LAD) - a deployable set of 640 Silicon
Drift Detectors, for a total effective area of about 3.4 m^2, between 6 and 10
keV, and spectral resolution <250 eV; the Polarimetry Focusing Array (PFA) - a
set of 2 X-ray telescope, for a total effective area of 250 cm^2 at 2 keV,
equipped with imaging gas pixel photoelectric polarimeters; the Wide Field
Monitor (WFM) - a set of 3 coded mask wide field units, equipped with
position-sensitive Silicon Drift Detectors, each covering a 90 degrees x 90
degrees FoV. The eXTP international consortium includes mostly major
institutions of the Chinese Academy of Sciences and Universities in China, as
well as major institutions in several European countries and the United States.
The predecessor of eXTP, the XTP mission concept, has been selected and funded
as one of the so-called background missions in the Strategic Priority Space
Science Program of the Chinese Academy of Sciences since 2011. The strong
European participation has significantly enhanced the scientific capabilities
of eXTP. The planned launch date of the mission is earlier than 2025.
[6]
oai:arXiv.org:1607.03729 [pdf] - 1531021
The new SOXS instrument for the ESO NTT
Schipani, P.;
Claudi, R.;
Campana, S.;
Baruffolo, A.;
Basa, S.;
Basso, S.;
Cappellaro, E.;
Cascone, E.;
Cosentino, R.;
DAlessio, F.;
De Caprio, V.;
Della Valle, M.;
Postigo, A. de Ugarte;
DOrsi, S.;
Franzen, R.;
Fynbo, J.;
Gal-Yam, A.;
Gardiol, D.;
Giro, E.;
Hamuy, M.;
Iuzzolino, M.;
Loreggia, D.;
Mattila, S.;
Munari, M.;
Pignata, G.;
Riva, M.;
Savarese, S.;
Schmidt, B.;
Scuderi, S.;
Smartt, S.;
Vitali, F.
Submitted: 2016-07-13
SOXS (Son Of X-Shooter) will be a unique spectroscopic facility for the
ESO-NTT 3.5-m telescope in La Silla (Chile), able to cover the optical/NIR band
(350-1750 nm). The design foresees a high-efficiency spectrograph with a
resolution-slit product of ~4,500, capable of simultaneously observing the
complete spectral range 350 - 1750 nm with a good sensitivity, with light
imaging capabilities in the visible band. This paper outlines the status of the
project.
[7]
oai:arXiv.org:1510.00910 [pdf] - 1287738
Active shape correction of a thin glass/plastic X-ray mirror
Spiga, D.;
Barbera, M.;
Basso, S.;
Civitani, M.;
Collura, A.;
Dell'Agostino, S.;
Cicero, U. Lo;
Lullo, G.;
Pelliciari, C.;
Riva, M.;
Salmaso, B.;
Sciortino, L.
Submitted: 2015-10-04
Optics for future X-ray telescopes will be characterized by very large
aperture and focal length, and will be made of lightweight materials like glass
or plastic in order to keep the total mass within acceptable limits. Optics
based on thin slumped glass foils are currently in use in the NuSTAR telescope
and are being developed at various institutes like INAF/OAB, aiming at
improving the angular resolution to a few arcsec HEW. Another possibility would
be the use of thin plastic foils, being developed at SAO and the Palermo
University. Even if relevant progresses in the achieved angular resolution were
recently made, a viable possibility to further improve the mirror figure would
be the application of piezoelectric actuators onto the non-optical side of the
mirrors. In fact, thin mirrors are prone to deform, so they require a careful
integration to avoid deformations and even correct forming errors. This however
offers the possibility to actively correct the residual deformation. Even if
other groups are already at work on this idea, we are pursuing the concept of
active integration of thin glass or plastic foils with piezoelectric patches,
fed by voltages driven by the feedback provided by X-rays, in intra-focal setup
at the XACT facility at INAF/OAPA. In this work, we show the preliminary
simulations and the first steps taken in this project.
[8]
oai:arXiv.org:1509.03478 [pdf] - 1275564
Angular resolution measurements at SPring-8 of a hard X-ray optic for
the New Hard X-ray Mission
Spiga, D.;
Raimondi, L.;
Furuzawa, A.;
Basso, S.;
Binda, R.;
Borghi, G.;
Cotroneo, V.;
Grisoni, G.;
Kunieda, H.;
Marioni, F.;
Matsumoto, H.;
Mori, H.;
Miyazawa, T.;
Negri, B.;
Orlandi, A.;
Pareschi, G.;
Salmaso, B.;
Tagliaferri, G.;
Uesugi, K.;
Valsecchi, G.;
Vernani, D.
Submitted: 2015-09-11
The realization of X-ray telescopes with imaging capabilities in the hard (>
10 keV) X-ray band requires the adoption of optics with shallow (< 0.25 deg)
grazing angles to enhance the reflectivity of reflective coatings. On the other
hand, to obtain large collecting area, large mirror diameters (< 350 mm) are
necessary. This implies that mirrors with focal lengths >10 m shall be produced
and tested. Full-illumination tests of such mirrors are usually performed with
on- ground X-ray facilities, aimed at measuring their effective area and the
angular resolution; however, they in general suffer from effects of the finite
distance of the X-ray source, e.g. a loss of effective area for double
reflection. These effects increase with the focal length of the mirror under
test; hence a "partial" full-illumination measurement might not be fully
representative of the in-flight performances. Indeed, a pencil beam test can be
adopted to overcome this shortcoming, because a sector at a time is exposed to
the X-ray flux, and the compensation of the beam divergence is achieved by
tilting the optic. In this work we present the result of a hard X-ray test
campaign performed at the BL20B2 beamline of the SPring-8 synchrotron radiation
facility, aimed at characterizing the Point Spread Function (PSF) of a
multilayer-coated Wolter-I mirror shell manufactured by Nickel electroforming.
The mirror shell is a demonstrator for the NHXM hard X-ray imaging telescope
(0.3 - 80 keV), with a predicted HEW (Half Energy Width) close to 20 arcsec. We
show some reconstructed PSFs at monochromatic X-ray energies of 15 to 63 keV,
and compare them with the PSFs computed from post-campaign metrology data,
self-consistently treating profile and roughness data by means of a method
based on the Fresnel diffraction theory. The modeling matches the measured PSFs
accurately.
[10]
oai:arXiv.org:1509.02298 [pdf] - 1273356
Profile reconstruction of grazing-incidence X-ray mirrors from
intra-focal X-ray full imaging
Spiga, D.;
Basso, S.;
Bavdaz, M.;
Burwitz, V.;
Civitani, M.;
Citterio, O.;
Ghigo, M.;
Hartner, G.;
Menz, B.;
Pareschi, G.;
Proserpio, L.;
Salmaso, B.;
Tagliaferri, G.;
Wille, E.
Submitted: 2015-09-08
The optics of a number of future X-ray telescopes will have very long focal
lengths (10 - 20 m), and will consist of a number of nested/stacked thin,
grazing-incidence mirrors. The optical quality characterization of a real
mirror can be obtained via profile metrology, and the Point Spread Function of
the mirror can be derived via one of the standard computation methods. However,
in practical cases it can be difficult to access the optical surfaces of
densely stacked mirror shells, after they have been assembled, using the
widespread metrological tools. For this reason, the assessment of the imaging
resolution of a system of mirrors is better obtained via a direct,
full-illumination test in X-rays. If the focus cannot be reached, an
intra-focus test can be performed, and the image can be compared with the
simulation results based on the metrology, if available. However, until today
no quantitative information was extracted from a full-illumination, intra-focal
exposure. In this work we show that, if the detector is located at an optimal
distance from the mirror, the intensity variations of the intra-focal,
full-illumination image in single reflection can be used to reconstruct the
profile of the mirror surface, without the need of a wavefront sensor. The
Point Spread Function can be subsequently computed from the reconstructed
mirror shape. We show the application of this method to an intra-focal (8 m
distance from mirror) test performed at PANTER on an optical module prototype
made of hot-slumped glass foils with a 20 m focal length, from which we could
derive an expected imaging quality near 16 arcsec HEW.
[11]
oai:arXiv.org:1502.03308 [pdf] - 1303946
Development of mirrors made of chemically tempered glass foils for
future X-ray telescopes
Submitted: 2015-02-11
Thin slumped glass foils are considered good candidates for the realization
of future X-ray telescopes with large effective area and high spatial
resolution. However, the hot slumping process affects the glass strength, and
this can be an issue during the launch of the satellite because of the high
kinematical and static loads occurring during that phase. In the present work
we have investigated the possible use of Gorilla glass (produced by Corning), a
chemical tempered glass that, thanks to its strength characteristics, would be
ideal. The un-tempered glass foils were curved by means of an innovative hot
slumping technique and subsequently chemically tempered. In this paper we show
that the chemical tempering process applied to Gorilla glass foils does not
affect the surface micro-roughness of the mirrors. On the other end, the stress
introduced by the tempering process causes a reduction in the amplitude of the
longitudinal profile errors with a lateral size close to the mirror length. The
effect of the overall shape changes in the final resolution performance of the
glass mirrors was studied by simulating the glass foils integration with our
innovative approach based on glass reinforcing ribs. The preliminary tests
performed so far suggest that this approach has the potential to be applied to
the X-ray telescopes of the next generation.
[12]
oai:arXiv.org:1402.3445 [pdf] - 1203354
Evaluation of the surface strength of glass plates shaped by hot
slumping process
Proserpio, L.;
Basso, S.;
Borsa, F.;
Citterio, O.;
Civitani, M.;
Ghigo, M.;
Pareschi, G.;
Salmaso, B.;
Sironi, G.;
Spiga, D.;
Tagliaferri, G.;
D'Este, A.;
Dall'Igna, R.;
Silvestri, M.;
Parodi, G.;
Martelli, F.;
Bavdaz, M.;
Wille, E.
Submitted: 2014-02-14, last modified: 2014-07-09
The Hot Slumping Technology is under development by several research groups
in the world for the realization of grazing-incidence segmented mirrors for
X-ray astronomy, based on thin glass plates shaped over a mould at temperatures
above the transformation point. The performed thermal cycle and related
operations might have effects on the strength characteristics of the glass,
with consequences on the structural design of the elemental optical modules and
consecutively on the entire X-ray optic for large astronomical missions like
IXO and ATHENA. The mechanical strength of glass plates after they underwent
the slumping process was tested through destructive double-ring tests in the
context of a study performed by the Astronomical Observatory of Brera with the
collaboration of Stazione Sperimentale del Vetro and BCV Progetti. The entire
study has been realized on more than 200 D263 Schott borosilicate glass
specimens of dimension 100 mm x 100 mm and thickness 0.4 mm, either flat or
bent at a Radius of Curvature of 1000 mm through the particular pressure
assisted hot slumping process developed by INAF-OAB. The collected experimental
data have been compared to non-linear FEM analyses and treated with Weibull
statistic to assess the current IXO glass X-ray telescope design, in terms of
survival probability, when subject to static and acoustic loads characteristic
of the launch phase. The paper describes the activities performed and presents
the obtained results.
[13]
oai:arXiv.org:1403.7200 [pdf] - 1208656
The imaging properties of the Gas Pixel Detector as a focal plane
polarimeter
Fabiani, S.;
Costa, E.;
Del Monte, E.;
Muleri, F.;
Soffitta, P.;
Rubini, A.;
Bellazzini, R.;
Brez, A.;
de Ruvo, L.;
Minuti, M.;
Pinchera, M.;
Sgrò, C.;
Spandre, G.;
Spiga, D.;
Tagliaferri, G.;
Pareschi, G.;
Basso, S.;
Citterio, O.;
Burwitz, V.;
Burkert, W.;
Menz, B.;
Hartner, G.
Submitted: 2014-03-27
X-rays are particularly suited to probe the physics of extreme objects.
However, despite the enormous improvements of X-ray Astronomy in imaging,
spectroscopy and timing, polarimetry remains largely unexplored. We propose the
photoelectric polarimeter Gas Pixel Detector (GPD) as an instrument candidate
to fill the gap of more than thirty years of lack of measurements. The GPD, in
the focus of a telescope, will increase the sensitivity of orders of magnitude.
Moreover, since it can measure the energy, the position, the arrival time and
the polarization angle of every single photon, allows to perform polarimetry of
subsets of data singled out from the spectrum, the light curve or the image of
source. The GPD has an intrinsic very fine imaging capability and in this work
we report on the calibration campaign carried out in 2012 at the PANTER X-ray
test facility of the Max-Planck-Institut f\"ur extraterrestrische Physik of
Garching (Germany) in which, for the first time, we coupled it to a JET-X
optics module with a focal length of 3.5 m and an angular resolution of 18
arcsec at 4.5 keV. This configuration was proposed in 2012 aboard the X-ray
Imaging Polarimetry Explorer (XIPE) in response to the ESA call for a small
mission. We derived the imaging and polarimetric performance for extended
sources like Pulsar Wind Nebulae and Supernova Remnants as case studies for the
XIPE configuration, discussing also possible improvements by coupling the
detector with advanced optics, having finer angular resolution and larger
effective area, to study with more details extended objects.
[14]
oai:arXiv.org:1311.2220 [pdf] - 786443
Re-testing the JET-X Flight Module No. 2 at the PANTER facility
Spiga, Daniele;
Tagliaferri, Gianpiero;
Soffitta, Paolo;
Citterio, Oberto;
Basso, Stefano;
Bellazzini, Ronaldo;
Brez, Alessandro;
Burkert, Wolfgang;
Burwitz, Vadim;
Costa, Enrico;
de Ruvo, Luca;
Del Monte, Ettore;
Fabiani, Sergio;
Hartner, Gisela;
Menz, Benedikt;
Minuti, Massimo;
Muleri, Fabio;
Pareschi, Giovanni;
Pinchera, Michele;
Rubini, Alda;
Sgrò, Carmelo;
Spandre, Gloria
Submitted: 2013-11-09, last modified: 2014-02-18
The Joint European X-ray Telescope (JET-X) was the core instrument of the
Russian Spectrum-X-gamma space observatory. It consisted of two identical soft
X-ray (0.3 - 10 keV) telescopes with focusing optical modules having a measured
angular resolution of nearly 15 arcsec. Soon after the payload completion, the
mission was cancelled and the two optical flight modules (FM) were brought to
the Brera Astronomical Observatory where they had been manufactured. After 16
years of storage, we have utilized the JET-X FM2 to test at the PANTER X-ray
facility a prototype of a novel X-ray polarimetric telescope, using a Gas Pixel
Detector (GPD) with polarimetric capabilities in the focal plane of the FM2.
The GPD was developed by a collaboration between INFN-Pisa and INAF-IAPS. In
the first phase of the test campaign, we have re-tested the FM2 at PANTER to
have an up-to-date characterization in terms of angular resolution and
effective area, while in the second part of the test the GPD has been placed in
the focal plane of the FM2. In this paper we report the results of the tests of
the sole FM2, using an unpolarized X-ray source, comparing the results with the
calibration done in 1996.
[15]
oai:arXiv.org:1309.6995 [pdf] - 1453148
XIPE: the X-ray Imaging Polarimetry Explorer
Soffitta, Paolo;
Barcons, Xavier;
Bellazzini, Ronaldo;
Braga, João;
Costa, Enrico;
Fraser, George W.;
Gburek, Szymon;
Huovelin, Juhani;
Matt, Giorgio;
Pearce, Mark;
Poutanen, Juri;
Reglero, Victor;
Santangelo, Andrea;
Sunyaev, Rashid A.;
Tagliaferri, Gianpiero;
Weisskopf, Martin;
Aloisio, Roberto;
Amato, Elena;
Attiná, Primo;
Axelsson, Magnus;
Baldini, Luca;
Basso, Stefano;
Bianchi, Stefano;
Blasi, Pasquale;
Bregeon, Johan;
Brez, Alessandro;
Bucciantini, Niccoló;
Burderi, Luciano;
Burwitz, Vadim;
Casella, Piergiorgio;
Churazov, Eugene;
Civitani, Marta;
Covino, Stefano;
da Silva, Rui Miguel Curado;
Cusumano, Giancarlo;
Dadina, Mauro;
D'Amico, Flavio;
De Rosa, Alessandra;
Di Cosimo, Sergio;
Di Persio, Giuseppe;
Di Salvo, Tiziana;
Dovciak, Michal;
Elsner, Ronald;
Eyles, Chris J.;
Fabian, Andrew C.;
Fabiani, Sergio;
Feng, Hua;
Giarrusso, Salvatore;
Goosmann, René W.;
Grandi, Paola;
Grosso, Nicolas;
Israel, Gianluca;
Jackson, Miranda;
Kaaret, Philip;
Karas, Vladimir;
Kuss, Michael;
Lai, Dong;
La Rosa, Giovanni;
Larsson, Josefin;
Larsson, Stefan;
Latronico, Luca;
Maggio, Antonio;
Maia, Jorge;
Marin, Frédéric;
Massai, Marco Maria;
Mineo, Teresa;
Minuti, Massimo;
Moretti, Elena;
Muleri, Fabio;
O'Dell, Stephen L.;
Pareschi, Giovanni;
Peres, Giovanni;
Pesce, Melissa;
Petrucci, Pierre-Olivier;
Pinchera, Michele;
Porquet, Delphine;
Ramsey, Brian;
Rea, Nanda;
Reale, Fabio;
Rodrigo, Juana Maria;
Różańska, Agata;
Rubini, Alda;
Rudawy, Pawel;
Ryde, Felix;
Salvati, Marco;
Júnior, Valdivino Alexandre de Santiago;
Sazonov, Sergey;
Sgró, Carmelo;
Silver, Eric;
Spandre, Gloria;
Spiga, Daniele;
Stella, Luigi;
Tamagawa, Toru;
Tamborra, Francesco;
Tavecchio, Fabrizio;
Dias, Teresa Teixeira;
van Adelsberg, Matthew;
Wu, Kinwah;
Zane, Silvia
Submitted: 2013-09-26
X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and
temporal variability measurements and to imaging, allows a wealth of physical
phenomena in astrophysics to be studied. X-ray polarimetry investigates the
acceleration process, for example, including those typical of magnetic
reconnection in solar flares, but also emission in the strong magnetic fields
of neutron stars and white dwarfs. It detects scattering in asymmetric
structures such as accretion disks and columns, and in the so-called molecular
torus and ionization cones. In addition, it allows fundamental physics in
regimes of gravity and of magnetic field intensity not accessible to
experiments on the Earth to be probed. Finally, models that describe
fundamental interactions (e.g. quantum gravity and the extension of the
Standard Model) can be tested. We describe in this paper the X-ray Imaging
Polarimetry Explorer (XIPE), proposed in June 2012 to the first ESA call for a
small mission with a launch in 2017 but not selected. XIPE is composed of two
out of the three existing JET-X telescopes with two Gas Pixel Detectors (GPD)
filled with a He-DME mixture at their focus and two additional GPDs filled with
pressurized Ar-DME facing the sun. The Minimum Detectable Polarization is 14 %
at 1 mCrab in 10E5 s (2-10 keV) and 0.6 % for an X10 class flare. The Half
Energy Width, measured at PANTER X-ray test facility (MPE, Germany) with JET-X
optics is 24 arcsec. XIPE takes advantage of a low-earth equatorial orbit with
Malindi as down-link station and of a Mission Operation Center (MOC) at INPE
(Brazil).
[17]
oai:arXiv.org:1105.0637 [pdf] - 353860
POLARIX: a pathfinder mission of X-ray polarimetry
Costa, Enrico;
Bellazzini, Ronaldo;
Tagliaferri, Gianpiero;
Matt, Giorgio;
Argan, Andrea;
Attina', Primo;
Baldini, Luca;
Basso, Stefano;
Brez, Alessandro;
Citterio, Oberto;
Di Cosimo, Sergio;
Cotroneo, Vincenzo;
Fabiani, Sergio;
Feroci, Marco;
Ferri, Antonella;
Latronico, Luca;
Lazzarotto, Francesco;
Minuti, Massimo;
Morelli, Ennio;
Muleri, Fabio;
Nicolini, Lucio;
Pareschi, Giovanni;
Di Persio, Giuseppe;
Pinchera, Michele;
Razzano, Massimiliano;
Reboa, Luigia;
Rubini, Alda;
Salonico, Antonio Maria;
Sgro', Carmelo;
Soffitta, Paolo;
Spandre, Gloria;
Spiga, Daniele;
Trois, Alessio
Submitted: 2011-05-03
Since the birth of X-ray astronomy, spectral, spatial and timing observation
improved dramatically, procuring a wealth of information on the majority of the
classes of the celestial sources. Polarimetry, instead, remained basically
unprobed. X-ray polarimetry promises to provide additional information
procuring two new observable quantities, the degree and the angle of
polarization. POLARIX is a mission dedicated to X-ray polarimetry. It exploits
the polarimetric response of a Gas Pixel Detector, combined with position
sensitivity, that, at the focus of a telescope, results in a huge increase of
sensitivity. Three Gas Pixel Detectors are coupled with three X-ray optics
which are the heritage of JET-X mission. POLARIX will measure time resolved
X-ray polarization with an angular resolution of about 20 arcsec in a field of
view of 15 arcmin $\times$ 15 arcmin and with an energy resolution of 20 % at 6
keV. The Minimum Detectable Polarization is 12 % for a source having a flux of
1 mCrab and 10^5 s of observing time. The satellite will be placed in an
equatorial orbit of 505 km of altitude by a Vega launcher.The telemetry
down-link station will be Malindi. The pointing of POLARIX satellite will be
gyroless and it will perform a double pointing during the earth occultation of
one source, so maximizing the scientific return. POLARIX data are for 75 % open
to the community while 25 % + SVP (Science Verification Phase, 1 month of
operation) is dedicated to a core program activity open to the contribution of
associated scientists. The planned duration of the mission is one year plus
three months of commissioning and SVP, suitable to perform most of the basic
science within the reach of this instrument.
[18]
oai:arXiv.org:1104.2048 [pdf] - 576598
ORIGIN: Metal Creation and Evolution from the Cosmic Dawn
Herder, J. W. den;
Piro, L.;
Ohashi, T.;
Kouveliotou, C.;
Hartmann, D. H.;
Kaastra, J. S.;
Amati, L.;
Andersen, M. I.;
Arnaud, M.;
Attéia, J-L.;
Bandler, S.;
Barbera, M.;
Barcons, X.;
Barthelmy, S.;
Basa, S.;
Basso, S.;
Boer, M.;
Branchini, E.;
Branduardi-Raymont, G.;
Borgani, S.;
Boyarsky, A.;
Brunetti, G.;
Budtz-Jorgensen, C.;
Burrows, D.;
Butler, N.;
Campana, S.;
Caroli, E.;
Ceballos, M.;
Christensen, F.;
Churazov, E.;
Comastri, A.;
Colasanti, L.;
Cole, R.;
Content, R.;
Corsi, A.;
Costantini, E.;
Conconi, P.;
Cusumano, G.;
de Plaa, J.;
De Rosa, A.;
Del Santo, M.;
Di Cosimo, S.;
De Pasquale, M.;
Doriese, R.;
Ettori, S.;
Evans, P.;
Ezoe, Y.;
Ferrari, L.;
Finger, H.;
Figueroa-Feliciano, T.;
Friedrich, P.;
Fujimoto, R.;
Furuzawa, A.;
Fynbo, J.;
Gatti, F.;
Galeazzi, M.;
Gehrels, N.;
Gendre, B.;
Ghirlanda, G.;
Ghisellini, G.;
Gilfanov, M.;
Giommi, P.;
Girardi, M.;
Grindlay, J.;
Cocchi, M.;
Godet, O.;
Guedel, M.;
Haardt, F.;
Hartog, R. den;
Hepburn, I.;
Hermsen, W.;
Hjorth, J.;
Hoekstra, H.;
Holland, A.;
Hornstrup, A.;
van der Horst, A.;
Hoshino, A.;
Zand, J. in 't;
Irwin, K.;
Ishisaki, Y.;
Jonker, P.;
Kitayama, T.;
Kawahara, H.;
Kawai, N.;
Kelley, R.;
Kilbourne, C.;
de Korte, P.;
Kusenko, A.;
Kuvvetli, I.;
Labanti, M.;
Macculi, C.;
Maiolino, R.;
Hesse, M. Mas;
Matsushita, K.;
Mazzotta, P.;
McCammon, D.;
Méndez, M.;
Mignani, R.;
Mineo, T.;
Mitsuda, K.;
Mushotzky, R.;
Molendi, S.;
Moscardini, L.;
Natalucci, L.;
Nicastro, F.;
O'Brien, P.;
Osborne, J.;
Paerels, F.;
Page, M.;
Paltani, S.;
Pedersen, K.;
Perinati, E.;
Ponman, T.;
Pointecouteau, E.;
Predehl, P.;
Porter, S.;
Rasmussen, A.;
Rauw, G.;
Röttgering, H.;
Roncarelli, M.;
Rosati, P.;
Quadrini, E.;
Ruchayskiy, O.;
Salvaterra, R.;
Sasaki, S.;
Sato, K.;
Savaglio, S.;
Schaye, J.;
Sciortino, S.;
Shaposhnikov, M.;
Sharples, R.;
Shinozaki, K.;
Spiga, D.;
Sunyaev, R.;
Suto, Y.;
Takei, Y.;
Tanvir, N.;
Tashiro, M.;
Tamura, T.;
Tawara, Y.;
Troja, E.;
Tsujimoto, M.;
Tsuru, T.;
Ubertini, P.;
Ullom, J.;
Ursino, E.;
Verbunt, F.;
van de Voort, F.;
Viel, M.;
Wachter, S.;
Watson, D.;
Weisskopf, M.;
Werner, N.;
White, N.;
Willingale, R.;
Wijers, R.;
Yamasaki, N.;
Yoshikawa, K.;
Zane, S.
Submitted: 2011-04-11, last modified: 2011-04-15
ORIGIN is a proposal for the M3 mission call of ESA aimed at the study of
metal creation from the epoch of cosmic dawn. Using high-spectral resolution in
the soft X-ray band, ORIGIN will be able to identify the physical conditions of
all abundant elements between C and Ni to red-shifts of z=10, and beyond. The
mission will answer questions such as: When were the first metals created? How
does the cosmic metal content evolve? Where do most of the metals reside in the
Universe? What is the role of metals in structure formation and evolution? To
reach out to the early Universe ORIGIN will use Gamma-Ray Bursts (GRBs) to
study their local environments in their host galaxies. This requires the
capability to slew the satellite in less than a minute to the GRB location. By
studying the chemical composition and properties of clusters of galaxies we can
extend the range of exploration to lower redshifts (z ~ 0.2). For this task we
need a high-resolution spectral imaging instrument with a large field of view.
Using the same instrument, we can also study the so far only partially detected
baryons in the Warm-Hot Intergalactic Medium (WHIM). The less dense part of the
WHIM will be studied using absorption lines at low redshift in the spectra for
GRBs.
[19]
oai:arXiv.org:0906.5367 [pdf] - 25787
Analytical computation of the off-axis Effective Area of grazing
incidence X-ray mirrors
Submitted: 2009-06-29, last modified: 2009-09-04
Focusing mirrors for X-ray telescopes in grazing incidence, introduced in the
70s, are characterized in terms of their performance by their imaging quality
and effective area, which in turn determines their sensitivity. Even though the
on-axis effective area is assumed in general to characterize the collecting
power of an X-ray optic, the telescope capability of imaging extended X-ray
sources is also determined by the variation in its effective area with the
off-axis angle. [...] The complex task of designing optics for future X-ray
telescopes entails detailed computations of both imaging quality and effective
area on- and off-axis. Because of their apparent complexity, both aspects have
been, so far, treated by using ray-tracing routines aimed at simulating the
interaction of X-ray photons with the reflecting surfaces of a given focusing
system. Although this approach has been widely exploited and proven to be
effective, it would also be attractive to regard the same problem from an
analytical viewpoint, to assess an optical design of an X-ray optical module
with a simpler calculation than a ray-tracing routine. [...] We have developed
useful analytical formulae for the off-axis effective area of a
double-reflection mirror in the double cone approximation, requiring only an
integration and the standard routines to calculate the X-ray coating
reflectivity for a given incidence angle. [...] Algebraic expressions are
provided for the mirror geometric area, as a function of the off-axis angle.
Finally, the results of the analytical computations presented here are
validated by comparison with the corresponding predictions of a ray-tracing
code.
[20]
oai:arXiv.org:0903.2483 [pdf] - 22372
Simbol-X Hard X-ray Focusing Mirrors: Results Obtained During the Phase
A Study
Tagliaferri, G.;
Basso, S.;
Borghi, G.;
Burkert, W.;
Citterio, O.;
Civitani, M.;
Conconi, P.;
Cotroneo, V.;
Freyberg, M.;
Garoli, D.;
Gorenstein, P.;
Hartner, G.;
Mattarello, V.;
Orlandi, A.;
Pareschi, G.;
Romaine, S.;
Spiga, D.;
Valsecchi, G.;
Vernani, D.
Submitted: 2009-03-13
Simbol-X will push grazing incidence imaging up to 80 keV, providing a strong
improvement both in sensitivity and angular resolution compared to all
instruments that have operated so far above 10 keV. The superb hard X-ray
imaging capability will be guaranteed by a mirror module of 100 electroformed
Nickel shells with a multilayer reflecting coating. Here we will describe the
technogical development and solutions adopted for the fabrication of the mirror
module, that must guarantee an Half Energy Width (HEW) better than 20 arcsec
from 0.5 up to 30 keV and a goal of 40 arcsec at 60 keV. During the phase A,
terminated at the end of 2008, we have developed three engineering models with
two, two and three shells, respectively. The most critical aspects in the
development of the Simbol-X mirrors are i) the production of the 100 mandrels
with very good surface quality within the timeline of the mission; ii) the
replication of shells that must be very thin (a factor of 2 thinner than those
of XMM-Newton) and still have very good image quality up to 80 keV; iii) the
development of an integration process that allows us to integrate these very
thin mirrors maintaining their intrinsic good image quality. The Phase A study
has shown that we can fabricate the mandrels with the needed quality and that
we have developed a valid integration process. The shells that we have produced
so far have a quite good image quality, e.g. HEW <~30 arcsec at 30 keV, and
effective area. However, we still need to make some improvements to reach the
requirements. We will briefly present these results and discuss the possible
improvements that we will investigate during phase B.
[21]
oai:arXiv.org:0810.2708 [pdf] - 17472
X-ray polarimetry on-board HXMT
Soffitta, Paolo;
Bellazzini, Ronaldo;
Tagliaferri, Gianpiero;
Costa, Enrico;
Pareschi, Giovanni;
Basso, Stefano;
Cotroneo, Vincenzo;
Frutti, Massimo;
Lazzarotto, Francesco;
Muleri, Fabio;
Rubini, Alda;
Spandre, Gloria;
Brez, Alessandro;
Baldini, Luca;
Bregeon, Jean;
Minuti, Massimo;
Matt, Giorgio;
Frontera, Filippo
Submitted: 2008-10-15
The development of micropixel gas detectors, capable to image tracks produced
in a gas by photoelectrons, makes possible to perform polarimetry of X-ray
celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a
mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with
Phoswich detectors, by exploitation of the direct demodulation technique. Since
a fraction of the HXMT time will be spent on dedicated pointing of particular
sources, it could host, with moderate additional resources a pair of X-ray
telescopes, each with a photoelectric X-ray polarimeter (EXP2, Efficient X-ray
Photoelectric Polarimeter) in the focal plane. We present the design of the
telescopes and the focal plane instrumentation and discuss the performance of
this instrument to detect the degree and angle of linear polarization of some
representative sources. Notwithstanding the limited resources, the proposed
instrument can represent a breakthrough in X-ray Polarimetry.
[22]
oai:arXiv.org:0807.0893 [pdf] - 14237
XIAO: a soft X-ray telescope for the SVOM Mission
Mereghetti, S.;
De Luca, A.;
Fiorini, M.;
La Palombara, N.;
Tiengo, A.;
Uslenghi, M.;
Vianello, G.;
Villa, G.;
Zambra, A.;
Moretti, A.;
Basso, S.;
Campana, S.;
Conconi, P.;
Cotroneo, V.;
Covino, S.;
Ghirlanda, G.;
Ghisellini, G.;
Pareschi, G.;
Tagliaferri, G.;
Trifoglio, M.;
Amati, L.;
Gianotti, F.;
Stella, L.;
Antonelli, A.;
Cordier, B.;
Gotz, D.
Submitted: 2008-07-06
The study of Gamma-ray bursts (GRBs) is a key field to expand our
understanding of several astrophysical and cosmological phenomena. SVOM is a
Chinese-French Mission which will permit to detect and rapidly locate GRBs, in
particular those at high redshift, and to study their multiwavelength emission.
The SVOM satellite, to be launched in 2013, will carry wide field instruments
operating in the X/gamma-ray band and narrow field optical and soft X-ray
telescopes. Here we describe a small soft X-ray telescope (XIAO) proposed as an
Italian contribution to the SVOM mission. Thanks to a grazing incidence X-ray
telescope with effective area of ~120 cm^2 and a short focal length, coupled to
a very compact, low noise, fast read out CCD camera, XIAO can substantially
contribute to the overall SVOM capabilities for both GRB and non-GRB science.
[23]
oai:arXiv.org:0709.3992 [pdf] - 5336
An X-ray Polarimeter for HXMT Mission
Costa, Enrico;
Bellazzini, Ronaldo;
Tagliaferri, Gianpiero;
Baldini, Luca;
Basso, Stefano;
Bregeon, Johan;
Brez, Alessandro;
Citterio, Oberto;
Cotroneo, Vincenzo;
Frontera, Filippo;
Frutti, Massimo;
Matt, Giorgio;
Minuti, Massimo;
Muleri, Fabio;
Pareschi, Giovanni;
Perola, Giuseppe Cesare;
Rubini, Alda;
Sgro', Carmelo;
Soffitta, Paolo;
Spandre, Gloria
Submitted: 2007-09-25
The development of micropixel gas detectors, capable to image tracks produced
in a gas by photoelectrons, makes possible to perform polarimetry of X-ray
celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a
mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with
Phoswich detectors, by exploitation of the direct demodulation technique. Since
a fraction of the HXMT time will be spent on dedicated pointing of particular
sources, it could host, with moderate additional resources a pair of X-ray
telescopes, each with a photoelectric X-ray polarimeter in the focal plane. We
present the design of the telescopes and the focal plane instrumentation and
discuss the performance of this instrument to detect the degree and angle of
linear polarization of some representative sources. Notwithstanding the limited
resources the proposed instrument can represent a breakthrough in X-ray
Polarimetry.
[24]
oai:arXiv.org:astro-ph/0509010 [pdf] - 75592
Active and passive shielding design optimization and technical solutions
for deep sensitivity hard X-ray focusing telescopes
Malaguti, G.;
Pareschi, G.;
Ferrando, P.;
Caroli, E.;
Di Cocco, G.;
Foschini, L.;
Basso, S.;
Del Sordo, S.;
Fiore, F.;
Bonati, A.;
Lesci, G.;
Poulsen, J. M.;
Monzani, F.;
Stevoli, A.;
Negri, B.
Submitted: 2005-09-01
The 10-100 keV region of the electromagnetic spectrum contains the potential
for a dramatic improvement in our understanding of a number of key problems in
high energy astrophysics. A deep inspection of the universe in this band is on
the other hand still lacking because of the demanding sensitivity (fraction of
microCrab in the 20-40 keV for 1 Ms integration time) and imaging (~15" angular
resolution) requirements. The mission ideas currently being proposed are based
on long focal length, grazing incidence, multi-layer optics, coupled with focal
plane detectors with few hundreds microns spatial resolution capability. The
required large focal lengths, ranging between 8 and 50 m, can be realized by
means of extendable optical benches (as foreseen e.g. for the HEXIT-SAT, NEXT
and NuSTAR missions) or formation flight scenarios (e.g. Simbol-X and XEUS).
While the final telescope design will require a detailed trade-off analysis
between all the relevant parameters (focal length, plate scale value, angular
resolution, field of view, detector size, and sensitivity degradation due to
detector dead area and telescope vignetting), extreme attention must be
dedicated to the background minimization. In this respect, key issues are
represented by the passive baffling system, which in case of large focal
lengths requires particular design assessments, and by the active/passive
shielding geometries and materials. In this work, the result of a study of the
expected background for a hard X-ray telescope is presented, and its
implication on the required sensitivity, together with the possible
implementation design concepts for active and passive shielding in the
framework of future satellite missions, are discussed.