sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Baryshev, A. M.

Normalized to: Baryshev, A.

26 article(s) in total. 156 co-authors, from 1 to 17 common article(s). Median position in authors list is 6,0.

[1]  oai:arXiv.org:2006.10120  [pdf] - 2117708
Simulations of M87 and Sgr A* Imaging with the Millimetron Space Observatory on near-Earth orbits
Comments: 12 pages, 6 figures
Submitted: 2020-06-17
High resolution imaging of supermassive black holes shadows is a direct way to verify the theory of general relativity at extreme gravity conditions. Very Long Baseline Interferometry (VLBI) observations at millimeter/sub-millimeter wavelengths can provide such angular resolution for supermassive black holes, located in Sgr A* and M87. Recent VLBI observations of M87 with the Event Horizon Telescope (EHT) has shown such capabilities. The maximum obtainable spatial resolution of EHT is limited by Earth diameter and atmospheric phase variations. In order to improve the image resolution longer baselines are required. Radioastron space mission has successfully demonstrated the capabilities of Space-Earth VLBI with baselines much larger than Earth diameter. Millimetron is a next space mission of the Russian Space Agency that will operate at millimeter wavelengths. Nominal orbit of the observatory will be located around Lagrangian L2 point of the Sun-Earth system. In order to optimize the VLBI mode, we consider a possible second stage of the mission that could use near-Earth high elliptical orbit (HEO). In this contribution a set of near Earth orbits is used for the synthetic space-ground VLBI observations of Sgr A* and M87 in joint Millimetron and EHT configuration. General-relativistic magnetohydrodynamic models (GRMHD) for black hole environment of Sgr A* and M87 are used for static and dynamic imaging simulations at 230 GHz. A comparison is made between ground and space-ground baselines. It demonstrates that joined observations with Millimetron and EHT facilities significantly improve the image resolution and allow obtaining the dynamic snapshot images of Sgr A*.
[2]  oai:arXiv.org:2002.03790  [pdf] - 2045588
Complex beam mapping and Fourier optics analysis of a wide field Microwave Kinetic Inductance Detector camera
Comments: This is a post-peer-review, pre-copy edit version of an article published in Journal of Low Temperature Physics. The final authenticated version is available online
Submitted: 2020-02-10
For astronomical instruments, accurate knowledge of the optical pointing and coupling are essential to characterize the alignment and performance of (sub-)systems prior to integration and deployment. Ideally, this requires the phase response of the optical system, which for direct (phase insensitive) detectors was not previously accessible. Here we show development of the phase sensitive complex beam pattern technique using a dual optical source heterodyne technique for a large field of view Microwave Kinetic Inductance Detector camera at 350 GHz. We show here how you can analyze the measured data with Fourier optics, which allows integration into a telescope model to calculate the on sky beam pattern and telescope aperture efficiency prior to deployment at a telescope.
[3]  oai:arXiv.org:1907.03479  [pdf] - 1912083
First Generation Heterodyne Instrumentation Concepts for the Atacama Large Aperture Submillimeter Telescope
Comments: to be published in the proceedings of the 30th International Symposium on Space Terahertz Technology (https://www.isstt2019.com/). Final version will appear when the link to the 30th annual proceedings becomes active: https://www.nrao.edu/meetings/isstt/tocs.shtml
Submitted: 2019-07-08
(abridged) The Atacama Large Aperture Submillimeter Telescope (AtLAST) project aims to build a 50-m-class submm telescope with $>1^\circ$ field of view, high in the Atacama Desert, providing fast and detailed mapping of the mm/submm sky. It will thus serve as a strong complement to existing facilities such as ALMA. ALMA's small field of view ($<15^{\prime\prime}$ at 350 GHz) limits its mapping speed for large surveys. Instead, a single dish with a large field of view such as the AtLAST concept can host large multi-element instruments that can more efficiently map large portions of the sky. Small aperture survey instruments (typically much smaller than $<3\times$ the size of an interferometric array element) can mitigate this somewhat but lack the resolution for accurate recovery of source location and have small collecting areas. Furthermore, small aperture survey instruments do not provide sufficient overlap in the spatial scales they sample to provide a complete reconstruction of extended sources (i.e.\ the zero-spacing information is incomplete in $u,v$-space.) The heterodyne instrumentation for the AtLAST telescope that we consider here will take advantage of extensive developments in the past decade improving the performance and pixel count of heterodyne focal plane arrays. Such instrumentation, with higher pixel counts, has alredy begun to take advantage of integration in the focal planes to increase packaging efficiency over simply stacking modular mixer blocks in the focal plane. We extrapolate from the current state-of-the-art to present concept first-generation heterodyne designs for AtLAST.
[4]  oai:arXiv.org:1809.08341  [pdf] - 1755195
Analysis techniques for complex-field radiation pattern measurements
Comments:
Submitted: 2018-09-21
Complex field measurements are increasingly becoming the standard for state-of-the-art astronomical instrumentation. Complex field measurements have been used to characterize a suite of ground, airborne, and space-based heterodyne receiver missions [1], [2], [3], [4], [5], [6], and a description of how to acquire coherent field maps for direct detector arrays was demonstrated in Davis et. al. 2017. This technique has the ability to determine both amplitude and phase radiation patterns from individual pixels on an array. Phase information helps to better characterize the optical performance of the array (as compared to total power radiation patterns) by constraining the fit in an additional plane [4]. Here we discuss the mathematical framework used in an analysis pipeline developed to process complex field radiation pattern measurements. This routine determines and compensates misalignments of the instrument and scanning system. We begin with an overview of Gaussian beam formalism and how it relates to complex field pattern measurements. Next we discuss a scan strategy using an offset in z along the optical axis that allows first-order optical standing waves between the scanned source and optical system to be removed in post-processing. Also discussed is a method by which the co- and cross-polarization fields can be extracted individually for each pixel by rotating the two orthogonal measurement planes until the signal is the co-polarization map is maximized (and the signal in the cross-polarization field is minimized). We detail a minimization function that can fit measurement data to an arbitrary beam shape model. We conclude by discussing the angular plane wave spectral (APWS) method for beam propagation, including the near-field to far-field transformation.
[5]  oai:arXiv.org:1809.04452  [pdf] - 1749362
Eliminating stray radiation inside large area imaging arrays
Comments: arXiv admin note: substantial text overlap with arXiv:1707.02142
Submitted: 2018-09-11
With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves. We demonstrate this effect with focal plane arrays of absorber coupled Lumped Element microwave Kinetic Inductance Detectors (LEKIDs) and lens-antenna coupled distributed quarter wavelength Microwave Kinetic Inductance Detectors (MKIDs). In these arrays the response from a point source at the pixel position is at a similar level to the stray response integrated over the entire chip area. For the antenna coupled arrays, we show that this effect can be suppressed by incorporating an on-chip stray light absorber. A similar method should be possible with the LEKID array, especially when they are lens coupled.
[6]  oai:arXiv.org:1712.07396  [pdf] - 1606357
SEPIA - a new single pixel receiver at the APEX Telescope
Comments: Accepted for publication in Astronomy & Astrophysics
Submitted: 2017-12-20
Context: We describe the new SEPIA (Swedish-ESO PI Instrument for APEX) receiver, which was designed and built by the Group for Advanced Receiver Development (GARD), at Onsala Space Observatory (OSO) in collaboration with ESO. It was installed and commissioned at the APEX telescope during 2015 with an ALMA Band 5 receiver channel and updated with a new frequency channel (ALMA Band 9) in February 2016. Aims: This manuscript aims to provide, for observers who use the SEPIA receiver, a reference in terms of the hardware description, optics and performance as well as the commissioning results. Methods: Out of three available receiver cartridge positions in SEPIA, the two current frequency channels, corresponding to ALMA Band 5, the RF band 158--211 GHz, and Band 9, the RF band 600--722 GHz, provide state-of-the-art dual polarization receivers. The Band 5 frequency channel uses 2SB SIS mixers with an average SSB noise temperature around 45K with IF (intermediate frequency) band 4--8 GHz for each sideband providing total 4x4 GHz IF band. The Band 9 frequency channel uses DSB SIS mixers with a noise temperature of 75--125K with IF band 4--12 GHz for each polarization. Results: Both current SEPIA receiver channels are available to all APEX observers.
[7]  oai:arXiv.org:1707.02142  [pdf] - 1585646
Surface wave control for large arrays of microwave kinetic inductance detectors
Comments: accepted for publication in IEEE Transactions on Terahertz Science and Technology
Submitted: 2017-07-07
Large ultra-sensitive detector arrays are needed for present and future observatories for far infra-red, submillimeter wave (THz), and millimeter wave astronomy. With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves, the surface wave. We demonstrate this effect with focal plane arrays of 880 lens-antenna coupled Microwave Kinetic Inductance Detectors (MKIDs). Presented here are near field measurements of the MKID optical response versus the position on the array of a reimaged optical source. We demonstrate that the optical response of a detector in these arrays saturates off-pixel at the $\sim-30$ dB level compared to the peak pixel response. The result is that the power detected from a point source at the pixel position is almost identical to the stray response integrated over the chip area. With such a contribution, it would be impossible to measure extended sources, while the point source sensitivity is degraded due to an increase of the stray loading. However, we show that by incorporating an on-chip stray light absorber, the surface wave contribution is reduced by a factor $>$10. With the on-chip stray light absorber the point source response is close to simulations down to the $\sim-35$ dB level, the simulation based on an ideal Gaussian illumination of the optics. In addition, as a crosscheck we show that the extended source response of a single pixel in the array with the absorbing grid is in agreement with the integral of the point source measurements.
[8]  oai:arXiv.org:1609.01952  [pdf] - 1574543
A kilo-pixel imaging system for future space based far-infrared observatories using microwave kinetic inductance detectors
Comments: Resubmitted manuscript after review A&A (2016) 16 pages, 10 figures
Submitted: 2016-09-07, last modified: 2017-03-01
Future astrophysics and cosmic microwave background space missions operating in the far-infrared to millimetre part of the spectrum will require very large arrays of ultra-sensitive detectors in combination with high multiplexing factors and efficient low-noise and low-power readout systems. We have developed a demonstrator system suitable for such applications. The system combines a 961 pixel imaging array based upon Microwave Kinetic Inductance Detectors (MKIDs) with a readout system capable of reading out all pixels simultaneously with only one readout cable pair and a single cryogenic amplifier. We evaluate, in a representative environment, the system performance in terms of sensitivity, dynamic range, optical efficiency, cosmic ray rejection, pixel-pixel crosstalk and overall yield at at an observation centre frequency of 850 GHz and 20% fractional bandwidth. The overall system has an excellent sensitivity, with an average detector sensitivity NEPdet=3x10^-19 W/rt(Hz) measured using a thermal calibration source. At a loading power per pixel of 50fW we demonstrate white, photon noise limited detector noise down to 300 mHz. The dynamic range would allow the detection of 1 Jy bright sources within the field of view without tuning the readout of the detectors. The expected dead time due to cosmic ray interactions, when operated in an L2 or a similar far-Earth orbit, is found to be <4%. Additionally, the achieved pixel yield is 83% and the crosstalk between the pixels is <-30dB. This demonstrates that MKID technology can provide multiplexing ratios on the order of a 1000 with state-of-the-art single pixel performance, and that the technology is now mature enough to be considered for future space based observatories and experiments.
[9]  oai:arXiv.org:1609.00163  [pdf] - 1472993
Measurements and analysis of optical crosstalk in a microwave kinetic inductance detector array
Comments: 8 pages, 8 figures, Proc. SPIE 9914, Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy VIII, 99143L (July 20, 2016)
Submitted: 2016-09-01
The main advantage of Microwave Kinetic Inductance Detector arrays (MKID) is their multiplexing capability, which allows for building cameras with a large number of pixels and good sensitivity, particularly suitable to perform large blank galaxy surveys. However, to have as many pixels as possible it is necessary to arrange detectors close in readout frequency. Consequently KIDs overlap in frequency and are coupled to each other producing crosstalk. Because crosstalk can be only minimised by improving the array design, in this work we aim to correct for this effect a posteriori. We analysed a MKID array consisting of 880 KIDs with readout frequencies at 4-8 GHz. We measured the beam patterns for every detector in the array and described the response of each detector by using a two-dimensional Gaussian fit. Then, we identified detectors affected by crosstalk above -30 dB level from the maximum and removed the signal of the crosstalking detectors. Moreover, we modelled the crosstalk level for each KID as a function of the readout frequency separation starting from the assumption that the transmission of a KID is a Lorenztian function in power. We were able to describe the general crosstalk level of the array and the crosstalk of each KID within 5 dB, so enabling the design of future arrays with the crosstalk as a design criterion. In this work, we demonstrate that it is possible to process MKID images a posteriori to decrease the crosstalk effect, subtracting the response of each coupled KID from the original map.
[10]  oai:arXiv.org:1507.04151  [pdf] - 1384120
Multiplexed Readout for 1000-pixel Arrays of Microwave Kinetic Inductance Detectors
Comments: 7 pages, 7 figures
Submitted: 2015-07-15, last modified: 2016-04-01
Microwave Kinetic Inductance Detectors (MKIDs) are the most attractive radiation detectors for far-infrared and sub-mm astronomy: They combine ultimate sensitivity with the possibility to create very large detector arrays, in excess of 10 000 pixels. This is possible by reading-out the arrays using RF frequency division multiplexing, which allows multiplexing ratios in excess of 1000 pixels per readout line. We describe a novel readout system for large arrays of MKIDs, operating in a 2 GHz band in the 4-8 GHz range. The readout, which is a combination of a digital front- and back-end and an analog up- and down-converter system, can read out up to 4000 detectors simultaneously with 1 kHz datarate. The system achieves a readout noise power spectral density of -98 dBc/Hz while reading 1000 carriers simultaneously, which scales linear with the number of carriers. We demonstrate that 4000 state-of-the-art Aluminium-NbTiN MKIDs can be read out without deteriorating their intrinsic performance.
[11]  oai:arXiv.org:1602.00442  [pdf] - 1356872
Calibration scheme for large Kinetic Inductance Detector Arrays based on Readout Frequency Response
Comments: Accepted to Journal of Low Temperature Physics LTD16 Special Issue, Low Temperature Detector 16 Conference Proceedings,manuscript number: #JLTP-D-15-00356R1, 6 pages, 5 figures
Submitted: 2016-02-01
Microwave kinetic inductance detector (MKID) provides a way to build large ground based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good linearity and calibration over wide dynamic range. We propose to use the MKID readout frequency response to determine the MKID responsivity to an input optical source power. A signal can be measured in a KID as a change in the phase of the readout signal with respect to the KID resonant circle. Fundamentally, this phase change is due to a shift in the KID resonance frequency, in turn due to a radiation induced change in the quasiparticle number in the superconducting resonator. We show that shift in resonant frequency can be determined from the phase shift by using KID phase versus frequency dependence using a previously measured resonant frequency. Working in this calculated resonant frequency, we gain near linearity and constant calibration to a constant optical signal applied in a wide range of operating points on the resonance and readout powers. This calibration method has three particular advantages: first, it is fast enough to be used to calibrate large arrays, with pixel counts in the thousand of pixels; second, it is based on data that are already necessary to determine KID positions; third, it can be done without applying any optical source in front of the array.
[12]  oai:arXiv.org:1601.01449  [pdf] - 1382106
Observations and modelling of CO and [CI] in disks. First detections of [CI] and constraints on the carbon abundance
Comments: 8 figures, accepted for publication in A\&A
Submitted: 2016-01-07
The gas-solid budget of carbon in protoplanetary disks is related to the composition of the cores and atmospheres of the planets forming in them. The key gas-phase carbon carriers CO, C$^{0}$ and C$^{+}$ can now be observed in disks. The gas-phase carbon abundance in disks has not yet been well characterized, we aim to obtain new constraints on the [C]/[H] ratio in a sample of disks, and to get an overview of the strength of [CI] and warm CO emission. We carried out a survey of the CO$\,6$--$5$ and [CI]$\,1$--$0$ and $2$--$1$ lines towards $37$ disks with APEX, and supplemented it with [CII] data from the literature. The data are interpreted using a grid of models produced with the DALI code. We also investigate how well the gas-phase carbon abundance can be determined in light of parameter uncertainties. The CO$\,6$--$5$ line is detected in $13$ out of $33$ sources, the [CI]$\,1$--$0$ in $6$ out of $12$, and the [CI]$\,2$--$1$ in $1$ out of $33$. With deep integrations, the first unambiguous detections of [CI]~$1$--$0$ in disks are obtained, in TW~Hya and HD~100546. Gas-phase carbon abundance reductions of a factor $5$--$10$ or more can be identified robustly based on CO and [CI] detections. The atomic carbon detection in TW~Hya confirms a factor $100$ reduction of [C]/[H]$_{\rm gas}$ in that disk, while the data are consistent with an ISM-like carbon abundance for HD~100546. In addition, BP~Tau, T~Cha, HD~139614, HD~141569, and HD~100453 are either carbon-depleted or gas-poor disks. The low [CI]~$2$--$1$ detection rates in the survey mostly reflect insufficient sensitivity to detect T~Tauri disks. The Herbig~Ae/Be disks with CO and [CII] upper limits below the models are debris disk like systems. A roughly order of magnitude increase in sensitivity compared to our survey is required to obtain useful constraints on the gas-phase [C]/[H] ratio in most of the targeted systems.
[13]  oai:arXiv.org:1507.01937  [pdf] - 1362563
Outflow forces in intermediate mass star formation
Comments: 14 pages, accepted for publication in A&A; changed a few boldface text left in
Submitted: 2015-07-07, last modified: 2015-07-10
Intermediate mass protostarsprovide a bridge between theories of low- and high-mass star formation. Emerging molecular outflows can be used to determine the influence of fragmentation and multiplicity on protostellar evolution through the correlation of outflow forces of intermediate mass protostars with the luminosity. The aim of this paper is to derive outflow forces from outflows of six intermediate mass protostellar regions and validate the apparent correlation between total luminosity and outflow force seen in earlier work, as well as remove uncertainties caused by different methodology. By comparing CO 6--5 observations obtained with APEX with non-LTE radiative transfer model predictions, optical depths, temperatures, densities of the gas of the molecular outflows are derived. Outflow forces, dynamical timescales and kinetic luminosities are subsequently calculated. Outflow parameters, including the forces, were derived for all sources. Temperatures in excess of 50 K were found for all flows, in line with recent low-mass results. However, comparison with other studies could not corroborate conclusions from earlier work on intermediate mass protostars which hypothesized that fragmentation enhances outflow forces in clustered intermediate mass star formation. Any enhancement in comparison with the classical relation between outflow force and luminosity can be attributed the use of a higher excitation line and improvement in methods; They are in line with results from low-mass protostars using similar techniques. The role of fragmentation on outflows is an important ingredient to understand clustered star formation and the link between low and high-mass star formation. However, detailed information on spatial scales of a few 100 AU, covering all individual members is needed to make the necessary progress.
[14]  oai:arXiv.org:1505.06191  [pdf] - 1238361
The non-equilibrium response of a superconductor to pair-breaking radiation measured over a broad frequency band
Comments:
Submitted: 2015-05-22
We have measured the absorption of terahertz radiation in a BCS superconductor over a broad range of frequencies from 200 GHz to 1.1 THz, using a broadband antenna-lens system and a tantalum microwave resonator. From low frequencies, the response of the resonator rises rapidly to a maximum at the gap edge of the superconductor. From there on the response drops to half the maximum response at twice the pair-breaking energy. At higher frequencies, the response rises again due to trapping of pair-breaking phonons in the superconductor. In practice this is the first measurement of the frequency dependence of the quasiparticle creation efficiency due to pair-breaking in a superconductor. The efficiency, calculated from the different non-equilibrium quasiparticle distribution functions at each frequency, is in agreement with the measurements.
[15]  oai:arXiv.org:1503.01988  [pdf] - 1043147
The ALMA Band 9 receiver - Design, construction, characterization, and first light
Comments:
Submitted: 2015-03-06
We describe the design, construction, and characterization of the Band 9 heterodyne receivers (600-720 GHz) for the Atacama Large Millimeter / submillimeter Array (ALMA). The ALMA Band 9 receiver units ("cartridges"), which are installed in the telescope's front end, have been designed to detect and down-convert two orthogonal linear polarization components of the light collected by the ALMA antennas. The light entering the front end is refocused with a compact arrangement of mirrors, which is fully contained within the cartridge. The arrangement contains a grid to separate the polarizations and two beam splitters to combine each resulting beam with a local oscillator signal. The combined beams are fed into independent double-sideband mixers, each with a corrugated feedhorn coupling the radiation by way of a waveguide with backshort cavity into an impedance-tuned SIS junction that performs the heterodyne down-conversion. Finally, the generated intermediate frequency signals are amplified by cryogenic and room-temperature HEMT amplifiers and exported to the telescope's back end for further processing and, finally, correlation. The receivers have been constructed and tested in the laboratory and they show excellent performance, complying with ALMA requirements. Performance statistics on all 73 Band 9 receivers are reported. On-sky characterization and tests of the performance of the Band 9 cartridges are presented using commissioning data.
[16]  oai:arXiv.org:1408.3314  [pdf] - 863527
Performance of Hybrid NbTiN-Al Microwave Kinetic Inductance Detectors as Direct Detectors for Sub-millimeter Astronomy
Comments: 7 pages, 3 figures. Presented at SPIE Astronomical Telescopes and Instrumentation 2014: Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy VII
Submitted: 2014-08-14
In the next decades millimeter and sub-mm astronomy requires large format imaging arrays and broad-band spectrometers to complement the high spatial and spectral resolution of the Atacama Large Millimeter/sub-millimeter Array. The desired sensors for these instruments should have a background limited sensitivity and a high optical efficiency and enable arrays thousands of pixels in size. Hybrid microwave kinetic inductance detectors consisting of NbTiN and Al have shown to satisfy these requirements. We present the second generation hybrid NbTiN-Al MKIDs, which are photon noise limited in both phase and amplitude readout for loading levels $P_{850GHz} \geq 10$ fW. Thanks to the increased responsivity, the photon noise level achieved in phase allows us to simultaneously read out approximately 8000 pixels using state-of-the-art electronics. In addition, the choice of superconducting materials and the use of a Si lens in combination with a planar antenna gives these resonators the flexibility to operate within the frequency range $0.09 < \nu < 1.1$ THz. Given these specifications, hybrid NbTiN-Al MKIDs will enable astronomically usable kilopixel arrays for sub-mm imaging and moderate resolution spectroscopy.
[17]  oai:arXiv.org:1311.2429  [pdf] - 747105
High optical efficiency and photon noise limited sensitivity of microwave kinetic inductance detectors using phase readout
Comments: 5 pages, 4 figures
Submitted: 2013-11-11
We demonstrate photon noise limited performance in both phase and amplitude readout in microwave kinetic inductance detectors (MKIDs) consisting of NbTiN and Al, down to 100 fW of optical power. We simulate the far field beam pattern of the lens-antenna system used to couple radiation into the MKID and derive an aperture efficiency of 75%. This is close to the theoretical maximum of 80% for a single-moded detector. The beam patterns are verified by a detailed analysis of the optical coupling within our measurement setup.
[18]  oai:arXiv.org:1303.7151  [pdf] - 683399
On-chip filter bank spectroscopy at 600-700 GHz using NbTiN superconducting resonators
Comments: 4 pages, 3 figures, submitted to Applied Physics Letters
Submitted: 2013-03-28, last modified: 2013-06-21
We experimentally demonstrate the principle of an on-chip submillimeter wave filter bank spectrometer, using superconducting microresonators as narrow band-separation filters. The filters are made of NbTiN/SiNx/NbTiN microstrip line resonators, which have a resonance frequency in the range of 614-685 GHz---two orders of magnitude higher in frequency than what is currently studied for use in circuit quantum electrodynamics and photodetectors. The frequency resolution of the filters decreases from 350 to 140 with increasing frequency, most likely limited by dissipation of the resonators.
[19]  oai:arXiv.org:1107.4330  [pdf] - 1078138
Photon noise limited radiation detection with lens-antenna coupled Microwave Kinetic Inductance Detectors
Comments: The following article has been submitted to APL
Submitted: 2011-07-21
Microwave Kinetic Inductance Detectors (MKIDs) have shown great potential for sub-mm instrumentation because of the high scalability of the technology. Here we demonstrate for the first time in the sub-mm band (0.1...2 mm) a photon noise limited performance of a small antenna coupled MKID detector array and we describe the relation between photon noise and MKID intrinsic generation-recombination noise. Additionally we use the observed photon noise to measure the optical efficiency of detectors to be 0.8+-0.2.
[20]  oai:arXiv.org:1107.3333  [pdf] - 1078024
Integrated Filterbank for DESHIMA: A Submillimeter Imaging Spectrograph Based on Superconducting Resonators
Comments: 6 pages, 4 figures, submitted to LTD-14 / Journal of Low Temperature Physics
Submitted: 2011-07-17
An integrated filterbank (IFB) in combination with microwave kinetic inductance detectors (MKIDs), both based on superconducting resonators, could be used to make broadband submillimeter imaging spectrographs that are compact and flexible. In order to investigate the possibility of adopting an IFB configuration for DESHIMA (Delft SRON High-redshift Mapper), we study the basic properties of a coplanar-waveguide-based IFB using electromagnetic simulation. We show that a coupling efficiency greater than 1/2 can be achieved if transmission losses are negligible. We arrive at a practical design for a 9 pixel x 920 color 3 dimensional imaging device that fits on a 4 inch wafer, which instantaneously covers multiple submillimeter telluric windows with a dispersion of f/df = 1000.
[21]  oai:arXiv.org:1102.0870  [pdf] - 958350
A dual-band millimeter-wave kinetic inductance camera for the IRAM 30-meter telescope
Comments: Submitted to ApJ (abstract reduced to fit ApJ standards)
Submitted: 2011-02-04, last modified: 2011-02-08
Context. The Neel IRAM KIDs Array (NIKA) is a fully-integrated measurement system based on kinetic inductance detectors (KIDs) currently being developed for millimeter wave astronomy. In a first technical run, NIKA was successfully tested in 2009 at the Institute for Millimetric Radio Astronomy (IRAM) 30-meter telescope at Pico Veleta, Spain. This prototype consisted of a 27-42 pixel camera imaging at 150 GHz. Subsequently, an improved system has been developed and tested in October 2010 at the Pico Veleta telescope. The instrument upgrades included dual-band optics allowing simultaneous imaging at 150 GHz and 220 GHz, faster sampling electronics enabling synchronous measurement of up to 112 pixels per measurement band, improved single-pixel sensitivity, and the fabrication of a sky simulator to replicate conditions present at the telescope. Results. The new dual-band NIKA was successfully tested in October 2010, performing in-line with sky simulator predictions. Initially the sources targeted during the 2009 run were re-imaged, verifying the improved system performance. An optical NEP was then calculated to be around 2 \dot 10-16 W/Hz1/2. This improvement in comparison with the 2009 run verifies that NIKA is approaching the target sensitivity for photon-noise limited ground-based detectors. Taking advantage of the larger arrays and increased sensitivity, a number of scientifically-relevant faint and extended objects were then imaged including the Galactic Center SgrB2(FIR1), the radio galaxy Cygnus A and the NGC1068 Seyfert galaxy. These targets were all observed simultaneously in the 150 GHz and 220 GHz atmospheric windows.
[22]  oai:arXiv.org:1004.2209  [pdf] - 301556
NIKA: A millimeter-wave kinetic inductance camera
Comments: Accepted for publication in Astronomy & Astrophysics
Submitted: 2010-04-13, last modified: 2010-06-20
Current generation millimeter wavelength detectors suffer from scaling limits imposed by complex cryogenic readout electronics. To circumvent this it is imperative to investigate technologies that intrinsically incorporate strong multiplexing. One possible solution is the kinetic inductance detector (KID). In order to assess the potential of this nascent technology, a prototype instrument optimized for the 2 mm atmospheric window was constructed. Known as the N\'eel IRAM KIDs Array (NIKA), it was recently tested at the Institute for Millimetric Radio Astronomy (IRAM) 30-meter telescope at Pico Veleta, Spain. The measurement resulted in the imaging of a number of sources, including planets, quasars, and galaxies. The images for Mars, radio star MWC349, quasar 3C345, and galaxy M87 are presented. From these results, the optical NEP was calculated to be around $1 \times 10^{-15}$ W$ / $Hz$^{1/2}$. A factor of 10 improvement is expected to be readily feasible by improvements in the detector materials and reduction of performance-degrading spurious radiation.
[23]  oai:arXiv.org:1005.1048  [pdf] - 1026701
Warm molecular gas and kinematics in the disc around HD 100546
Comments: 9pages, 3figures, Accepted for publication in Astronomy & Astrophysics
Submitted: 2010-05-06
The disc around the Herbig Ae/Be star HD 100546 is one of the most extensively studied discs in the southern sky. Although there is a wealth of information about its dust content and composition, not much is known about its gas and large scale kinematics. We detect and study the molecular gas in the disc at spatial resolution from 7.7" to 18.9" using the APEX telescope. The lines 12CO J=7-6, J=6-5, J=3-2, 13CO J=3-2 and [C I] 3P2-3P1 are observed, diagnostic of disc temperature, size, chemistry, and kinematics. We use parametric disc models that reproduce the low-J 12CO emission from Herbig~Ae stars and vary the basic disc parameters - temperature, mass and size. Using the molecular excitation and radiative transfer code RATRAN we fit the observed spectral line profiles. Our observations are consistent with more than 0.001 Msun of molecular gas in a disc of approximately 400 AU radius in Keplerian rotation around a 2.5 Msun star, seen at an inclination of 50 degrees. The detected 12CO lines are dominated by gas at 30-70~K. The non-detection of the [C I] line indicates excess ultraviolet emission above that of a B9 type model stellar atmosphere. Asymmetry in the 12CO line emission suggests that one side of the outer disc is colder by 10-20~K than the other, possibly due to a shadow by a warped geometry of the inner disc. Pointing offsets, foreground cloud absorption and asymmetry in the disc extent are excluded scenarios. Efficient heating of the outer disc ensures that low- and high-J 12CO lines are dominated by the outermost disc regions, indicating a 400 AU radius. The 12CO J=6--5 line arises from a disc layer higher above disc midplane, and warmer by 15-20~K than the layer emitting the J=3--2 line. The existing models of discs around Herbig Ae stars, assuming a B9.5 type model stellar atmosphere overproduce the [CI] 3P2--3P1 line intensity from HD 100546 by an order of magnitude.
[24]  oai:arXiv.org:0910.4937  [pdf] - 1018097
CHAMP+ observations of warm gas in M17 SW
Comments: Accepted for publication in Astronomy and Astrophysics, 12 pages, 10 figures, 1 table
Submitted: 2009-10-26, last modified: 2009-10-27
Since the main cooling lines of the gas phase are important tracers of the interstellar medium in Galactic and extragalactic sources, proper and detailed understanding of their emission, and the ambient conditions of the emitting gas, is necessary for a robust interpretation of the observations. With high resolution (7"-9") maps (~3x3 pc^2) of mid-J molecular lines we aim to probe the physical conditions and spatial distribution of the warm (50 to few hundred K) and dense gas (n(H_2)>10^5 cm^-3) across the interface region of M17 SW nebula. We have used the dual color multiple pixel receiver CHAMP+ on APEX telescope to obtain a 5'.3x4'.7 map of the J=6-5 and J=7-6 transitions of 12CO, the 13CO J=6-5 line, and the {^3P_2}-{^3P_1} 370 um fine-structure transition of [C I] in M17 SW. LTE and non-LTE radiative transfer models are used to constrain the ambient conditions. The warm gas extends up to a distance of ~2.2 pc from the M17 SW ridge. The 13CO J=6-5 and [C I] 370 um lines have a narrower spatial extent of about 1.3 pc along a strip line at P.A=63 deg. The structure and distribution of the [C I] {^3P_2}-{^3P_1} 370 um map indicate that its emission arises from the interclump medium with densities of the order of 10^3 cm^-3. The warmest gas is located along the ridge of the cloud, close to the ionization front. An LTE approximation indicates that the excitation temperature of the embedded clumps goes up to ~120 K. The non-LTE model suggests that the kinetic temperature at four selected positions cannot exceed 230 K in clumps of density n(H_2)~5x10^5 cm^-3, and that the warm T_k>100 K and dense (n(H_2)>10^4 cm^-3) gas traced by the mid-J 12CO lines represent just about 2% of the bulk of the molecular gas. The clump volume filling factor ranges between 0.04 and 0.11 at these positions.
[25]  oai:arXiv.org:0905.2878  [pdf] - 1002261
APEX-CHAMP+ high-J CO observations of low-mass young stellar objects: I. The HH 46 envelope and outflow
Comments: accepted by A&A
Submitted: 2009-05-18
AIMS Our aim is to characterize the size, mass, density and temperature profiles of the protostellar envelope of HH~46 IRS 1 and its surrounding cloud material as well as the effect the outflow has on its environment.METHODS The CHAMP+ and LABOCA arrays on the APEX telescope, combined with lower frequency line receivers, are used to obtain a large continuum map and smaller heterodyne maps in various isotopologues of CO and HCO+. The high-J lines of CO (6--5 and 7--6) and its isotopologues together with [C I] 2--1, observed with CHAMP+, are used to probe the warm molecular gas in the inner few hundred AU and in the outflowing gas. The data are interpreted with continuum and line radiative transfer models. RESULTS Broad outflow wings are seen in CO low- and high-J lines at several positions, constraining the gas temperatures to a constant value of ~100 K along the red outflow axis and to ~60 K for the blue outflow. The derived outflow mass is of order 0.4--0.8 M_sol, significantly higher than previously found. The bulk of the strong high-J CO line emission has a surprisingly narrow width, however, even at outflow positions. These lines cannot be fit by a passively heated model of the HH 46 IRS envelope. We propose that it originates from photon heating of the outflow cavity walls by ultraviolet photons originating in outflow shocks and the accretion disk boundary layers. At the position of the bow shock itself, the UV photons are energetic enough to dissociate CO. The envelope mass of ~5 M_sol is strongly concentrated towards HH 46 IRS with a density power law of -1.8.
[26]  oai:arXiv.org:0903.2431  [pdf] - 22358
FFTS readout for large arrays of Microwave Kinetic Inductance Detectors
Comments: The following article has been submitted to Applied Physics Letters. After it is published, it will be found at http://apl.aip.org/
Submitted: 2009-03-13
Microwave Kinetic Inductance Detectors (MKIDs) have great potential for large very sensitive detector arrays for use in, for example, sub-mm imaging. Being intrinsically readout in the frequency domain, they are particularly suited for frequency domain multiplexing allowing $\sim$1000s of devices to be readout with one pair of coaxial cables. However, this moves the complexity of the detector from the cryogenics to the warm electronics. We present here the concept and experimental demonstration of the use of Fast Fourier Transform Spectrometer (FFTS) readout, showing no deterioration of the noise performance compared to low noise analog mixing while allowing high multiplexing ratios.