Normalized to: Baryshev, A.
[1]
oai:arXiv.org:2006.10120 [pdf] - 2117708
Simulations of M87 and Sgr A* Imaging with the Millimetron Space
Observatory on near-Earth orbits
Andrianov, A. S.;
Baryshev, A. M.;
Falcke, H.;
Girin, I. A.;
de Graauw, T.;
Kostenko, V. I.;
Kudriashov, V.;
Ladygin, V. A.;
Likhachev, S. F.;
Roelofs, F.;
Rudnitskiy, A. G.;
Shaykhutdinov, A. R.;
Shchekinov, Y. A.;
Shchurov, M. A.
Submitted: 2020-06-17
High resolution imaging of supermassive black holes shadows is a direct way
to verify the theory of general relativity at extreme gravity conditions. Very
Long Baseline Interferometry (VLBI) observations at millimeter/sub-millimeter
wavelengths can provide such angular resolution for supermassive black holes,
located in Sgr A* and M87. Recent VLBI observations of M87 with the Event
Horizon Telescope (EHT) has shown such capabilities. The maximum obtainable
spatial resolution of EHT is limited by Earth diameter and atmospheric phase
variations. In order to improve the image resolution longer baselines are
required. Radioastron space mission has successfully demonstrated the
capabilities of Space-Earth VLBI with baselines much larger than Earth
diameter. Millimetron is a next space mission of the Russian Space Agency that
will operate at millimeter wavelengths. Nominal orbit of the observatory will
be located around Lagrangian L2 point of the Sun-Earth system. In order to
optimize the VLBI mode, we consider a possible second stage of the mission that
could use near-Earth high elliptical orbit (HEO). In this contribution a set of
near Earth orbits is used for the synthetic space-ground VLBI observations of
Sgr A* and M87 in joint Millimetron and EHT configuration. General-relativistic
magnetohydrodynamic models (GRMHD) for black hole environment of Sgr A* and M87
are used for static and dynamic imaging simulations at 230 GHz. A comparison is
made between ground and space-ground baselines. It demonstrates that joined
observations with Millimetron and EHT facilities significantly improve the
image resolution and allow obtaining the dynamic snapshot images of Sgr A*.
[2]
oai:arXiv.org:2002.03790 [pdf] - 2045588
Complex beam mapping and Fourier optics analysis of a wide field
Microwave Kinetic Inductance Detector camera
Submitted: 2020-02-10
For astronomical instruments, accurate knowledge of the optical pointing and
coupling are essential to characterize the alignment and performance of
(sub-)systems prior to integration and deployment. Ideally, this requires the
phase response of the optical system, which for direct (phase insensitive)
detectors was not previously accessible. Here we show development of the phase
sensitive complex beam pattern technique using a dual optical source heterodyne
technique for a large field of view Microwave Kinetic Inductance Detector
camera at 350 GHz. We show here how you can analyze the measured data with
Fourier optics, which allows integration into a telescope model to calculate
the on sky beam pattern and telescope aperture efficiency prior to deployment
at a telescope.
[3]
oai:arXiv.org:1907.03479 [pdf] - 1912083
First Generation Heterodyne Instrumentation Concepts for the Atacama
Large Aperture Submillimeter Telescope
Submitted: 2019-07-08
(abridged) The Atacama Large Aperture Submillimeter Telescope (AtLAST)
project aims to build a 50-m-class submm telescope with $>1^\circ$ field of
view, high in the Atacama Desert, providing fast and detailed mapping of the
mm/submm sky. It will thus serve as a strong complement to existing facilities
such as ALMA. ALMA's small field of view ($<15^{\prime\prime}$ at 350 GHz)
limits its mapping speed for large surveys. Instead, a single dish with a large
field of view such as the AtLAST concept can host large multi-element
instruments that can more efficiently map large portions of the sky. Small
aperture survey instruments (typically much smaller than $<3\times$ the size of
an interferometric array element) can mitigate this somewhat but lack the
resolution for accurate recovery of source location and have small collecting
areas. Furthermore, small aperture survey instruments do not provide sufficient
overlap in the spatial scales they sample to provide a complete reconstruction
of extended sources (i.e.\ the zero-spacing information is incomplete in
$u,v$-space.) The heterodyne instrumentation for the AtLAST telescope that we
consider here will take advantage of extensive developments in the past decade
improving the performance and pixel count of heterodyne focal plane arrays.
Such instrumentation, with higher pixel counts, has alredy begun to take
advantage of integration in the focal planes to increase packaging efficiency
over simply stacking modular mixer blocks in the focal plane. We extrapolate
from the current state-of-the-art to present concept first-generation
heterodyne designs for AtLAST.
[4]
oai:arXiv.org:1809.08341 [pdf] - 1755195
Analysis techniques for complex-field radiation pattern measurements
Submitted: 2018-09-21
Complex field measurements are increasingly becoming the standard for
state-of-the-art astronomical instrumentation. Complex field measurements have
been used to characterize a suite of ground, airborne, and space-based
heterodyne receiver missions [1], [2], [3], [4], [5], [6], and a description of
how to acquire coherent field maps for direct detector arrays was demonstrated
in Davis et. al. 2017. This technique has the ability to determine both
amplitude and phase radiation patterns from individual pixels on an array.
Phase information helps to better characterize the optical performance of the
array (as compared to total power radiation patterns) by constraining the fit
in an additional plane [4].
Here we discuss the mathematical framework used in an analysis pipeline
developed to process complex field radiation pattern measurements. This routine
determines and compensates misalignments of the instrument and scanning system.
We begin with an overview of Gaussian beam formalism and how it relates to
complex field pattern measurements. Next we discuss a scan strategy using an
offset in z along the optical axis that allows first-order optical standing
waves between the scanned source and optical system to be removed in
post-processing. Also discussed is a method by which the co- and
cross-polarization fields can be extracted individually for each pixel by
rotating the two orthogonal measurement planes until the signal is the
co-polarization map is maximized (and the signal in the cross-polarization
field is minimized). We detail a minimization function that can fit measurement
data to an arbitrary beam shape model. We conclude by discussing the angular
plane wave spectral (APWS) method for beam propagation, including the
near-field to far-field transformation.
[5]
oai:arXiv.org:1809.04452 [pdf] - 1749362
Eliminating stray radiation inside large area imaging arrays
Yates, Stephen J. C.;
Doyle, Simon;
Barry, Peter;
Baryshev, Andrey M.;
Bueno, Juan;
Ferrari, Lorenza;
Llombart, Nuria;
Murugesan, Vignesh;
Thoen, David J.;
Yurduseven, Ozan;
Baselmans, Jochem J. A.
Submitted: 2018-09-11
With increasing array size, it is increasingly important to control stray
radiation inside the detector chips themselves. We demonstrate this effect with
focal plane arrays of absorber coupled Lumped Element microwave Kinetic
Inductance Detectors (LEKIDs) and lens-antenna coupled distributed quarter
wavelength Microwave Kinetic Inductance Detectors (MKIDs). In these arrays the
response from a point source at the pixel position is at a similar level to the
stray response integrated over the entire chip area. For the antenna coupled
arrays, we show that this effect can be suppressed by incorporating an on-chip
stray light absorber. A similar method should be possible with the LEKID array,
especially when they are lens coupled.
[6]
oai:arXiv.org:1712.07396 [pdf] - 1606357
SEPIA - a new single pixel receiver at the APEX Telescope
Belitsky, V.;
Lapkin, I.;
Fredrixon, M.;
Meledin, D.;
Sundin, E.;
Billade, B.;
Ferm, S. -E.;
Pavolotsky, A.;
Rashid, H.;
Strandberg, M.;
Desmaris, V.;
Ermakov, A.;
Krause, S.;
Olberg, M.;
Aghdam, P.;
Shafiee, S.;
Bergman, P.;
De Beck, E.;
Olofsson, H.;
Conway, J.;
De Breuck, C.;
Immer, K.;
Yagoubov, P.;
Montenegro-Montes, F. M.;
Torstensson, K.;
Pérez-Beaupuits, J. -P.;
Klein, T.;
Boland, W.;
Baryshev, A. M.;
Hesper, R.;
Barkhof, J.;
Adema, J.;
Bekema, M. E.;
Koops, A.
Submitted: 2017-12-20
Context: We describe the new SEPIA (Swedish-ESO PI Instrument for APEX)
receiver, which was designed and built by the Group for Advanced Receiver
Development (GARD), at Onsala Space Observatory (OSO) in collaboration with
ESO. It was installed and commissioned at the APEX telescope during 2015 with
an ALMA Band 5 receiver channel and updated with a new frequency channel (ALMA
Band 9) in February 2016. Aims: This manuscript aims to provide, for observers
who use the SEPIA receiver, a reference in terms of the hardware description,
optics and performance as well as the commissioning results. Methods: Out of
three available receiver cartridge positions in SEPIA, the two current
frequency channels, corresponding to ALMA Band 5, the RF band 158--211 GHz, and
Band 9, the RF band 600--722 GHz, provide state-of-the-art dual polarization
receivers. The Band 5 frequency channel uses 2SB SIS mixers with an average SSB
noise temperature around 45K with IF (intermediate frequency) band 4--8 GHz for
each sideband providing total 4x4 GHz IF band. The Band 9 frequency channel
uses DSB SIS mixers with a noise temperature of 75--125K with IF band 4--12 GHz
for each polarization. Results: Both current SEPIA receiver channels are
available to all APEX observers.
[7]
oai:arXiv.org:1707.02142 [pdf] - 1585646
Surface wave control for large arrays of microwave kinetic inductance
detectors
Yates, Stephen J. C.;
Baryshev, Andrey M.;
Yurduseven, Ozan;
Bueno, Juan;
Davis, Kristina K.;
Ferrari, Lorenza;
Jellema, Willem;
Llombart, Nuria;
Murugesan, Vignesh;
Thoen, David J.;
Baselmans, Jochem J. A.
Submitted: 2017-07-07
Large ultra-sensitive detector arrays are needed for present and future
observatories for far infra-red, submillimeter wave (THz), and millimeter wave
astronomy. With increasing array size, it is increasingly important to control
stray radiation inside the detector chips themselves, the surface wave. We
demonstrate this effect with focal plane arrays of 880 lens-antenna coupled
Microwave Kinetic Inductance Detectors (MKIDs). Presented here are near field
measurements of the MKID optical response versus the position on the array of a
reimaged optical source. We demonstrate that the optical response of a detector
in these arrays saturates off-pixel at the $\sim-30$ dB level compared to the
peak pixel response. The result is that the power detected from a point source
at the pixel position is almost identical to the stray response integrated over
the chip area. With such a contribution, it would be impossible to measure
extended sources, while the point source sensitivity is degraded due to an
increase of the stray loading. However, we show that by incorporating an
on-chip stray light absorber, the surface wave contribution is reduced by a
factor $>$10. With the on-chip stray light absorber the point source response
is close to simulations down to the $\sim-35$ dB level, the simulation based on
an ideal Gaussian illumination of the optics. In addition, as a crosscheck we
show that the extended source response of a single pixel in the array with the
absorbing grid is in agreement with the integral of the point source
measurements.
[8]
oai:arXiv.org:1609.01952 [pdf] - 1574543
A kilo-pixel imaging system for future space based far-infrared
observatories using microwave kinetic inductance detectors
Baselmans, J. J. A.;
Bueno, J.;
Yates, S. J. C.;
Yurduseven, O.;
Llombart, N.;
Karatsu, K.;
Baryshev, A. M.;
Ferrari, L.;
Endo, A.;
Thoen, D. J.;
de Visser, P. J.;
Janssen, R. M. J.;
Murugesan, V.;
Driessen, E. F. C.;
Coiffard, G.;
Martin-Pintado, J.;
Hargrave, P.;
Griffin, M.
Submitted: 2016-09-07, last modified: 2017-03-01
Future astrophysics and cosmic microwave background space missions operating
in the far-infrared to millimetre part of the spectrum will require very large
arrays of ultra-sensitive detectors in combination with high multiplexing
factors and efficient low-noise and low-power readout systems. We have
developed a demonstrator system suitable for such applications. The system
combines a 961 pixel imaging array based upon Microwave Kinetic Inductance
Detectors (MKIDs) with a readout system capable of reading out all pixels
simultaneously with only one readout cable pair and a single cryogenic
amplifier. We evaluate, in a representative environment, the system performance
in terms of sensitivity, dynamic range, optical efficiency, cosmic ray
rejection, pixel-pixel crosstalk and overall yield at at an observation centre
frequency of 850 GHz and 20% fractional bandwidth. The overall system has an
excellent sensitivity, with an average detector sensitivity NEPdet=3x10^-19
W/rt(Hz) measured using a thermal calibration source. At a loading power per
pixel of 50fW we demonstrate white, photon noise limited detector noise down to
300 mHz. The dynamic range would allow the detection of 1 Jy bright sources
within the field of view without tuning the readout of the detectors. The
expected dead time due to cosmic ray interactions, when operated in an L2 or a
similar far-Earth orbit, is found to be <4%. Additionally, the achieved pixel
yield is 83% and the crosstalk between the pixels is <-30dB. This demonstrates
that MKID technology can provide multiplexing ratios on the order of a 1000
with state-of-the-art single pixel performance, and that the technology is now
mature enough to be considered for future space based observatories and
experiments.
[9]
oai:arXiv.org:1609.00163 [pdf] - 1472993
Measurements and analysis of optical crosstalk in a microwave kinetic
inductance detector array
Submitted: 2016-09-01
The main advantage of Microwave Kinetic Inductance Detector arrays (MKID) is
their multiplexing capability, which allows for building cameras with a large
number of pixels and good sensitivity, particularly suitable to perform large
blank galaxy surveys. However, to have as many pixels as possible it is
necessary to arrange detectors close in readout frequency. Consequently KIDs
overlap in frequency and are coupled to each other producing crosstalk. Because
crosstalk can be only minimised by improving the array design, in this work we
aim to correct for this effect a posteriori. We analysed a MKID array
consisting of 880 KIDs with readout frequencies at 4-8 GHz. We measured the
beam patterns for every detector in the array and described the response of
each detector by using a two-dimensional Gaussian fit. Then, we identified
detectors affected by crosstalk above -30 dB level from the maximum and removed
the signal of the crosstalking detectors. Moreover, we modelled the crosstalk
level for each KID as a function of the readout frequency separation starting
from the assumption that the transmission of a KID is a Lorenztian function in
power. We were able to describe the general crosstalk level of the array and
the crosstalk of each KID within 5 dB, so enabling the design of future arrays
with the crosstalk as a design criterion. In this work, we demonstrate that it
is possible to process MKID images a posteriori to decrease the crosstalk
effect, subtracting the response of each coupled KID from the original map.
[10]
oai:arXiv.org:1507.04151 [pdf] - 1384120
Multiplexed Readout for 1000-pixel Arrays of Microwave Kinetic
Inductance Detectors
Submitted: 2015-07-15, last modified: 2016-04-01
Microwave Kinetic Inductance Detectors (MKIDs) are the most attractive
radiation detectors for far-infrared and sub-mm astronomy: They combine
ultimate sensitivity with the possibility to create very large detector arrays,
in excess of 10 000 pixels. This is possible by reading-out the arrays using RF
frequency division multiplexing, which allows multiplexing ratios in excess of
1000 pixels per readout line. We describe a novel readout system for large
arrays of MKIDs, operating in a 2 GHz band in the 4-8 GHz range. The readout,
which is a combination of a digital front- and back-end and an analog up- and
down-converter system, can read out up to 4000 detectors simultaneously with 1
kHz datarate. The system achieves a readout noise power spectral density of -98
dBc/Hz while reading 1000 carriers simultaneously, which scales linear with the
number of carriers. We demonstrate that 4000 state-of-the-art Aluminium-NbTiN
MKIDs can be read out without deteriorating their intrinsic performance.
[11]
oai:arXiv.org:1602.00442 [pdf] - 1356872
Calibration scheme for large Kinetic Inductance Detector Arrays based on
Readout Frequency Response
Submitted: 2016-02-01
Microwave kinetic inductance detector (MKID) provides a way to build large
ground based sub-mm instruments such as NIKA and A-MKID. For such instruments,
therefore, it is important to understand and characterize the response to
ensure good linearity and calibration over wide dynamic range. We propose to
use the MKID readout frequency response to determine the MKID responsivity to
an input optical source power. A signal can be measured in a KID as a change in
the phase of the readout signal with respect to the KID resonant circle.
Fundamentally, this phase change is due to a shift in the KID resonance
frequency, in turn due to a radiation induced change in the quasiparticle
number in the superconducting resonator. We show that shift in resonant
frequency can be determined from the phase shift by using KID phase versus
frequency dependence using a previously measured resonant frequency. Working in
this calculated resonant frequency, we gain near linearity and constant
calibration to a constant optical signal applied in a wide range of operating
points on the resonance and readout powers. This calibration method has three
particular advantages: first, it is fast enough to be used to calibrate large
arrays, with pixel counts in the thousand of pixels; second, it is based on
data that are already necessary to determine KID positions; third, it can be
done without applying any optical source in front of the array.
[12]
oai:arXiv.org:1601.01449 [pdf] - 1382106
Observations and modelling of CO and [CI] in disks. First detections of
[CI] and constraints on the carbon abundance
Kama, M.;
Bruderer, S.;
Carney, M.;
Hogerheijde, M.;
van Dishoeck, E. F.;
Fedele, D.;
Baryshev, A.;
Boland, W.;
Güsten, R.;
Aikutalp, A.;
Choi, Y.;
Endo, A.;
Frieswijk, W.;
Karska, A.;
Klaassen, P.;
Koumpia, E.;
Kristensen, L.;
Leurini, S.;
Nagy, Z.;
Beaupuits, J. -P. Perez;
Risacher, C.;
van der Marel, N.;
van Kempen, T. A.;
van Weeren, R. J.;
Wyrowski, F.;
Yıldız, U. A.
Submitted: 2016-01-07
The gas-solid budget of carbon in protoplanetary disks is related to the
composition of the cores and atmospheres of the planets forming in them. The
key gas-phase carbon carriers CO, C$^{0}$ and C$^{+}$ can now be observed in
disks. The gas-phase carbon abundance in disks has not yet been well
characterized, we aim to obtain new constraints on the [C]/[H] ratio in a
sample of disks, and to get an overview of the strength of [CI] and warm CO
emission.
We carried out a survey of the CO$\,6$--$5$ and [CI]$\,1$--$0$ and $2$--$1$
lines towards $37$ disks with APEX, and supplemented it with [CII] data from
the literature. The data are interpreted using a grid of models produced with
the DALI code. We also investigate how well the gas-phase carbon abundance can
be determined in light of parameter uncertainties.
The CO$\,6$--$5$ line is detected in $13$ out of $33$ sources, the
[CI]$\,1$--$0$ in $6$ out of $12$, and the [CI]$\,2$--$1$ in $1$ out of $33$.
With deep integrations, the first unambiguous detections of [CI]~$1$--$0$ in
disks are obtained, in TW~Hya and HD~100546.
Gas-phase carbon abundance reductions of a factor $5$--$10$ or more can be
identified robustly based on CO and [CI] detections. The atomic carbon
detection in TW~Hya confirms a factor $100$ reduction of [C]/[H]$_{\rm gas}$ in
that disk, while the data are consistent with an ISM-like carbon abundance for
HD~100546. In addition, BP~Tau, T~Cha, HD~139614, HD~141569, and HD~100453 are
either carbon-depleted or gas-poor disks. The low [CI]~$2$--$1$ detection rates
in the survey mostly reflect insufficient sensitivity to detect T~Tauri disks.
The Herbig~Ae/Be disks with CO and [CII] upper limits below the models are
debris disk like systems. A roughly order of magnitude increase in sensitivity
compared to our survey is required to obtain useful constraints on the
gas-phase [C]/[H] ratio in most of the targeted systems.
[13]
oai:arXiv.org:1507.01937 [pdf] - 1362563
Outflow forces in intermediate mass star formation
van Kempen, T. A.;
Hogerheijde, M. R.;
van Dishoeck, E. F.;
Kristensen, L. E.;
Belloche, A.;
Klaassen, P. D.;
Leurini, S.;
Jose-Garcia, I. San;
Aykutalp, A.;
Choi, Y.;
Endo, A.;
Frieswijk, W.;
Harsono, D.;
Karska, A.;
Koumpia, E.;
van der Marel, N.;
Nagy, Z.;
Perez-Beaupuits, J. P.;
Risacher, C.;
van Weeren, R. J.;
Wyrowski, F.;
Yildiz, U. A.;
Guesten, R.;
Boland, W.;
Baryshev, A.
Submitted: 2015-07-07, last modified: 2015-07-10
Intermediate mass protostarsprovide a bridge between theories of low- and
high-mass star formation. Emerging molecular outflows can be used to determine
the influence of fragmentation and multiplicity on protostellar evolution
through the correlation of outflow forces of intermediate mass protostars with
the luminosity. The aim of this paper is to derive outflow forces from outflows
of six intermediate mass protostellar regions and validate the apparent
correlation between total luminosity and outflow force seen in earlier work, as
well as remove uncertainties caused by different methodology. By comparing CO
6--5 observations obtained with APEX with non-LTE radiative transfer model
predictions, optical depths, temperatures, densities of the gas of the
molecular outflows are derived. Outflow forces, dynamical timescales and
kinetic luminosities are subsequently calculated. Outflow parameters, including
the forces, were derived for all sources. Temperatures in excess of 50 K were
found for all flows, in line with recent low-mass results. However, comparison
with other studies could not corroborate conclusions from earlier work on
intermediate mass protostars which hypothesized that fragmentation enhances
outflow forces in clustered intermediate mass star formation. Any enhancement
in comparison with the classical relation between outflow force and luminosity
can be attributed the use of a higher excitation line and improvement in
methods; They are in line with results from low-mass protostars using similar
techniques. The role of fragmentation on outflows is an important ingredient to
understand clustered star formation and the link between low and high-mass star
formation. However, detailed information on spatial scales of a few 100 AU,
covering all individual members is needed to make the necessary progress.
[14]
oai:arXiv.org:1505.06191 [pdf] - 1238361
The non-equilibrium response of a superconductor to pair-breaking
radiation measured over a broad frequency band
de Visser, P. J.;
Yates, S. J. C.;
Guruswamy, T.;
Goldie, D. J.;
Withington, S.;
Neto, A.;
Llombart, N.;
Baryshev, A. M.;
Klapwijk, T. M.;
Baselmans, J. J. A.
Submitted: 2015-05-22
We have measured the absorption of terahertz radiation in a BCS
superconductor over a broad range of frequencies from 200 GHz to 1.1 THz, using
a broadband antenna-lens system and a tantalum microwave resonator. From low
frequencies, the response of the resonator rises rapidly to a maximum at the
gap edge of the superconductor. From there on the response drops to half the
maximum response at twice the pair-breaking energy. At higher frequencies, the
response rises again due to trapping of pair-breaking phonons in the
superconductor. In practice this is the first measurement of the frequency
dependence of the quasiparticle creation efficiency due to pair-breaking in a
superconductor. The efficiency, calculated from the different non-equilibrium
quasiparticle distribution functions at each frequency, is in agreement with
the measurements.
[15]
oai:arXiv.org:1503.01988 [pdf] - 1043147
The ALMA Band 9 receiver - Design, construction, characterization, and
first light
Baryshev, A. M.;
Hesper, R.;
Mena, F. P.;
Klapwijk, T. M.;
van Kempen, T. A.;
Hogerheijde, M. R.;
Jackson, B. D.;
Adema, J.;
Gerlofsma, G. J.;
Bekema, M. E.;
Barkhof, J.;
de Haan-Stijkel, L. H. R.;
Bemt, M. van den;
Koops, A.;
Keizer, K.;
Pieters, C.;
Jagt, J. Koops van het;
Schaeffer, H. H. A.;
Zijlstra, T.;
Kroug, M.;
Lodewijk, C. F. J.;
Wielinga, K.;
Boland, W.;
de Graauw, M. W. M.;
van Dishoeck, E. F.;
Jager, H.;
Wild, W.
Submitted: 2015-03-06
We describe the design, construction, and characterization of the Band 9
heterodyne receivers (600-720 GHz) for the Atacama Large Millimeter /
submillimeter Array (ALMA). The ALMA Band 9 receiver units ("cartridges"),
which are installed in the telescope's front end, have been designed to detect
and down-convert two orthogonal linear polarization components of the light
collected by the ALMA antennas. The light entering the front end is refocused
with a compact arrangement of mirrors, which is fully contained within the
cartridge. The arrangement contains a grid to separate the polarizations and
two beam splitters to combine each resulting beam with a local oscillator
signal. The combined beams are fed into independent double-sideband mixers,
each with a corrugated feedhorn coupling the radiation by way of a waveguide
with backshort cavity into an impedance-tuned SIS junction that performs the
heterodyne down-conversion. Finally, the generated intermediate frequency
signals are amplified by cryogenic and room-temperature HEMT amplifiers and
exported to the telescope's back end for further processing and, finally,
correlation. The receivers have been constructed and tested in the laboratory
and they show excellent performance, complying with ALMA requirements.
Performance statistics on all 73 Band 9 receivers are reported. On-sky
characterization and tests of the performance of the Band 9 cartridges are
presented using commissioning data.
[16]
oai:arXiv.org:1408.3314 [pdf] - 863527
Performance of Hybrid NbTiN-Al Microwave Kinetic Inductance Detectors as
Direct Detectors for Sub-millimeter Astronomy
Submitted: 2014-08-14
In the next decades millimeter and sub-mm astronomy requires large format
imaging arrays and broad-band spectrometers to complement the high spatial and
spectral resolution of the Atacama Large Millimeter/sub-millimeter Array. The
desired sensors for these instruments should have a background limited
sensitivity and a high optical efficiency and enable arrays thousands of pixels
in size. Hybrid microwave kinetic inductance detectors consisting of NbTiN and
Al have shown to satisfy these requirements. We present the second generation
hybrid NbTiN-Al MKIDs, which are photon noise limited in both phase and
amplitude readout for loading levels $P_{850GHz} \geq 10$ fW. Thanks to the
increased responsivity, the photon noise level achieved in phase allows us to
simultaneously read out approximately 8000 pixels using state-of-the-art
electronics. In addition, the choice of superconducting materials and the use
of a Si lens in combination with a planar antenna gives these resonators the
flexibility to operate within the frequency range $0.09 < \nu < 1.1$ THz. Given
these specifications, hybrid NbTiN-Al MKIDs will enable astronomically usable
kilopixel arrays for sub-mm imaging and moderate resolution spectroscopy.
[17]
oai:arXiv.org:1311.2429 [pdf] - 747105
High optical efficiency and photon noise limited sensitivity of
microwave kinetic inductance detectors using phase readout
Submitted: 2013-11-11
We demonstrate photon noise limited performance in both phase and amplitude
readout in microwave kinetic inductance detectors (MKIDs) consisting of NbTiN
and Al, down to 100 fW of optical power. We simulate the far field beam pattern
of the lens-antenna system used to couple radiation into the MKID and derive an
aperture efficiency of 75%. This is close to the theoretical maximum of 80% for
a single-moded detector. The beam patterns are verified by a detailed analysis
of the optical coupling within our measurement setup.
[18]
oai:arXiv.org:1303.7151 [pdf] - 683399
On-chip filter bank spectroscopy at 600-700 GHz using NbTiN
superconducting resonators
Submitted: 2013-03-28, last modified: 2013-06-21
We experimentally demonstrate the principle of an on-chip submillimeter wave
filter bank spectrometer, using superconducting microresonators as narrow
band-separation filters. The filters are made of NbTiN/SiNx/NbTiN microstrip
line resonators, which have a resonance frequency in the range of 614-685
GHz---two orders of magnitude higher in frequency than what is currently
studied for use in circuit quantum electrodynamics and photodetectors. The
frequency resolution of the filters decreases from 350 to 140 with increasing
frequency, most likely limited by dissipation of the resonators.
[19]
oai:arXiv.org:1107.4330 [pdf] - 1078138
Photon noise limited radiation detection with lens-antenna coupled
Microwave Kinetic Inductance Detectors
Submitted: 2011-07-21
Microwave Kinetic Inductance Detectors (MKIDs) have shown great potential for
sub-mm instrumentation because of the high scalability of the technology. Here
we demonstrate for the first time in the sub-mm band (0.1...2 mm) a photon
noise limited performance of a small antenna coupled MKID detector array and we
describe the relation between photon noise and MKID intrinsic
generation-recombination noise. Additionally we use the observed photon noise
to measure the optical efficiency of detectors to be 0.8+-0.2.
[20]
oai:arXiv.org:1107.3333 [pdf] - 1078024
Integrated Filterbank for DESHIMA: A Submillimeter Imaging Spectrograph
Based on Superconducting Resonators
Submitted: 2011-07-17
An integrated filterbank (IFB) in combination with microwave kinetic
inductance detectors (MKIDs), both based on superconducting resonators, could
be used to make broadband submillimeter imaging spectrographs that are compact
and flexible. In order to investigate the possibility of adopting an IFB
configuration for DESHIMA (Delft SRON High-redshift Mapper), we study the basic
properties of a coplanar-waveguide-based IFB using electromagnetic simulation.
We show that a coupling efficiency greater than 1/2 can be achieved if
transmission losses are negligible. We arrive at a practical design for a 9
pixel x 920 color 3 dimensional imaging device that fits on a 4 inch wafer,
which instantaneously covers multiple submillimeter telluric windows with a
dispersion of f/df = 1000.
[21]
oai:arXiv.org:1102.0870 [pdf] - 958350
A dual-band millimeter-wave kinetic inductance camera for the IRAM
30-meter telescope
Monfardini, A.;
Benoit, A.;
Bideaud, A.;
Swenson, L. J.;
Roesch, M.;
Desert, F. X.;
Doyle, S.;
Endo, A.;
Cruciani, A.;
Ade, P.;
Baryshev, A. M.;
Baselmans, J. J. A.;
Bourrion, O.;
Calvo, M.;
Camus, P.;
Ferrari, L.;
Giordano, C.;
Hoffmann, C.;
Leclercq, S.;
Macias-Perez, J. F.;
Mauskopf, P.;
Schuster, K. F.;
Tucker, C.;
Vescovi, C.;
Yates, S. J. C.
Submitted: 2011-02-04, last modified: 2011-02-08
Context. The Neel IRAM KIDs Array (NIKA) is a fully-integrated measurement
system based on kinetic inductance detectors (KIDs) currently being developed
for millimeter wave astronomy. In a first technical run, NIKA was successfully
tested in 2009 at the Institute for Millimetric Radio Astronomy (IRAM) 30-meter
telescope at Pico Veleta, Spain. This prototype consisted of a 27-42 pixel
camera imaging at 150 GHz. Subsequently, an improved system has been developed
and tested in October 2010 at the Pico Veleta telescope. The instrument
upgrades included dual-band optics allowing simultaneous imaging at 150 GHz and
220 GHz, faster sampling electronics enabling synchronous measurement of up to
112 pixels per measurement band, improved single-pixel sensitivity, and the
fabrication of a sky simulator to replicate conditions present at the
telescope. Results. The new dual-band NIKA was successfully tested in October
2010, performing in-line with sky simulator predictions. Initially the sources
targeted during the 2009 run were re-imaged, verifying the improved system
performance. An optical NEP was then calculated to be around 2 \dot 10-16
W/Hz1/2. This improvement in comparison with the 2009 run verifies that NIKA is
approaching the target sensitivity for photon-noise limited ground-based
detectors. Taking advantage of the larger arrays and increased sensitivity, a
number of scientifically-relevant faint and extended objects were then imaged
including the Galactic Center SgrB2(FIR1), the radio galaxy Cygnus A and the
NGC1068 Seyfert galaxy. These targets were all observed simultaneously in the
150 GHz and 220 GHz atmospheric windows.
[22]
oai:arXiv.org:1004.2209 [pdf] - 301556
NIKA: A millimeter-wave kinetic inductance camera
Monfardini, A.;
Swenson, L. J.;
Bideaud, A.;
Désert, F. X.;
Yates, S. J. C.;
Benoit, A.;
Baryshev, A. M.;
Baselmans, J. J. A.;
Doyle, S.;
Klein, B.;
Roesch, M.;
Tucker, C.;
Ade, P.;
Calvo, M.;
Camus, P.;
Giordano, C.;
Guesten, R.;
Hoffmann, C.;
Leclercq, S.;
Mauskopf, P.;
Schuster, K. F.
Submitted: 2010-04-13, last modified: 2010-06-20
Current generation millimeter wavelength detectors suffer from scaling limits
imposed by complex cryogenic readout electronics. To circumvent this it is
imperative to investigate technologies that intrinsically incorporate strong
multiplexing. One possible solution is the kinetic inductance detector (KID).
In order to assess the potential of this nascent technology, a prototype
instrument optimized for the 2 mm atmospheric window was constructed. Known as
the N\'eel IRAM KIDs Array (NIKA), it was recently tested at the Institute for
Millimetric Radio Astronomy (IRAM) 30-meter telescope at Pico Veleta, Spain.
The measurement resulted in the imaging of a number of sources, including
planets, quasars, and galaxies. The images for Mars, radio star MWC349, quasar
3C345, and galaxy M87 are presented. From these results, the optical NEP was
calculated to be around $1 \times 10^{-15}$ W$ / $Hz$^{1/2}$. A factor of 10
improvement is expected to be readily feasible by improvements in the detector
materials and reduction of performance-degrading spurious radiation.
[23]
oai:arXiv.org:1005.1048 [pdf] - 1026701
Warm molecular gas and kinematics in the disc around HD 100546
Submitted: 2010-05-06
The disc around the Herbig Ae/Be star HD 100546 is one of the most
extensively studied discs in the southern sky. Although there is a wealth of
information about its dust content and composition, not much is known about its
gas and large scale kinematics. We detect and study the molecular gas in the
disc at spatial resolution from 7.7" to 18.9" using the APEX telescope. The
lines 12CO J=7-6, J=6-5, J=3-2, 13CO J=3-2 and [C I] 3P2-3P1 are observed,
diagnostic of disc temperature, size, chemistry, and kinematics. We use
parametric disc models that reproduce the low-J 12CO emission from Herbig~Ae
stars and vary the basic disc parameters - temperature, mass and size. Using
the molecular excitation and radiative transfer code RATRAN we fit the observed
spectral line profiles. Our observations are consistent with more than 0.001
Msun of molecular gas in a disc of approximately 400 AU radius in Keplerian
rotation around a 2.5 Msun star, seen at an inclination of 50 degrees. The
detected 12CO lines are dominated by gas at 30-70~K. The non-detection of the
[C I] line indicates excess ultraviolet emission above that of a B9 type model
stellar atmosphere. Asymmetry in the 12CO line emission suggests that one side
of the outer disc is colder by 10-20~K than the other, possibly due to a shadow
by a warped geometry of the inner disc. Pointing offsets, foreground cloud
absorption and asymmetry in the disc extent are excluded scenarios. Efficient
heating of the outer disc ensures that low- and high-J 12CO lines are dominated
by the outermost disc regions, indicating a 400 AU radius. The 12CO J=6--5 line
arises from a disc layer higher above disc midplane, and warmer by 15-20~K than
the layer emitting the J=3--2 line. The existing models of discs around Herbig
Ae stars, assuming a B9.5 type model stellar atmosphere overproduce the [CI]
3P2--3P1 line intensity from HD 100546 by an order of magnitude.
[24]
oai:arXiv.org:0910.4937 [pdf] - 1018097
CHAMP+ observations of warm gas in M17 SW
Submitted: 2009-10-26, last modified: 2009-10-27
Since the main cooling lines of the gas phase are important tracers of the
interstellar medium in Galactic and extragalactic sources, proper and detailed
understanding of their emission, and the ambient conditions of the emitting
gas, is necessary for a robust interpretation of the observations. With high
resolution (7"-9") maps (~3x3 pc^2) of mid-J molecular lines we aim to probe
the physical conditions and spatial distribution of the warm (50 to few hundred
K) and dense gas (n(H_2)>10^5 cm^-3) across the interface region of M17 SW
nebula. We have used the dual color multiple pixel receiver CHAMP+ on APEX
telescope to obtain a 5'.3x4'.7 map of the J=6-5 and J=7-6 transitions of 12CO,
the 13CO J=6-5 line, and the {^3P_2}-{^3P_1} 370 um fine-structure transition
of [C I] in M17 SW. LTE and non-LTE radiative transfer models are used to
constrain the ambient conditions. The warm gas extends up to a distance of ~2.2
pc from the M17 SW ridge. The 13CO J=6-5 and [C I] 370 um lines have a narrower
spatial extent of about 1.3 pc along a strip line at P.A=63 deg. The structure
and distribution of the [C I] {^3P_2}-{^3P_1} 370 um map indicate that its
emission arises from the interclump medium with densities of the order of 10^3
cm^-3. The warmest gas is located along the ridge of the cloud, close to the
ionization front. An LTE approximation indicates that the excitation
temperature of the embedded clumps goes up to ~120 K. The non-LTE model
suggests that the kinetic temperature at four selected positions cannot exceed
230 K in clumps of density n(H_2)~5x10^5 cm^-3, and that the warm T_k>100 K and
dense (n(H_2)>10^4 cm^-3) gas traced by the mid-J 12CO lines represent just
about 2% of the bulk of the molecular gas. The clump volume filling factor
ranges between 0.04 and 0.11 at these positions.
[25]
oai:arXiv.org:0905.2878 [pdf] - 1002261
APEX-CHAMP+ high-J CO observations of low-mass young stellar objects: I.
The HH 46 envelope and outflow
van Kempen, T. A.;
van Dishoeck, E. F.;
Guesten, R.;
Kristensen, L. E.;
Schilke, P.;
Hogerheijde, M. R.;
Boland, W.;
Nefs, B.;
Menten, K. M.;
Baryshev, A.;
Wyrowski, F.
Submitted: 2009-05-18
AIMS Our aim is to characterize the size, mass, density and temperature
profiles of the protostellar envelope of HH~46 IRS 1 and its surrounding cloud
material as well as the effect the outflow has on its environment.METHODS The
CHAMP+ and LABOCA arrays on the APEX telescope, combined with lower frequency
line receivers, are used to obtain a large continuum map and smaller heterodyne
maps in various isotopologues of CO and HCO+. The high-J lines of CO (6--5 and
7--6) and its isotopologues together with [C I] 2--1, observed with CHAMP+, are
used to probe the warm molecular gas in the inner few hundred AU and in the
outflowing gas. The data are interpreted with continuum and line radiative
transfer models. RESULTS Broad outflow wings are seen in CO low- and high-J
lines at several positions, constraining the gas temperatures to a constant
value of ~100 K along the red outflow axis and to ~60 K for the blue outflow.
The derived outflow mass is of order 0.4--0.8 M_sol, significantly higher than
previously found. The bulk of the strong high-J CO line emission has a
surprisingly narrow width, however, even at outflow positions. These lines
cannot be fit by a passively heated model of the HH 46 IRS envelope. We propose
that it originates from photon heating of the outflow cavity walls by
ultraviolet photons originating in outflow shocks and the accretion disk
boundary layers. At the position of the bow shock itself, the UV photons are
energetic enough to dissociate CO. The envelope mass of ~5 M_sol is strongly
concentrated towards HH 46 IRS with a density power law of -1.8.
[26]
oai:arXiv.org:0903.2431 [pdf] - 22358
FFTS readout for large arrays of Microwave Kinetic Inductance Detectors
Submitted: 2009-03-13
Microwave Kinetic Inductance Detectors (MKIDs) have great potential for large
very sensitive detector arrays for use in, for example, sub-mm imaging. Being
intrinsically readout in the frequency domain, they are particularly suited for
frequency domain multiplexing allowing $\sim$1000s of devices to be readout
with one pair of coaxial cables. However, this moves the complexity of the
detector from the cryogenics to the warm electronics. We present here the
concept and experimental demonstration of the use of Fast Fourier Transform
Spectrometer (FFTS) readout, showing no deterioration of the noise performance
compared to low noise analog mixing while allowing high multiplexing ratios.