Normalized to: Barua, S.
[1]
oai:arXiv.org:2001.02570 [pdf] - 2038435
NuSTAR observation of Ark 564 reveals the variation of coronal
temperature with flux
Submitted: 2020-01-08
The hard X-ray spectral index of some AGN has been observed to steepen with
the source flux. This has been interpreted in a Comptonization scenario, where
an increase in the soft flux decreases the temperature of the corona, leading
to steepening of the photon index. However, the variation of the coronal
temperature with flux has been difficult to measure due to the presence of
complex reflection component in the hard X-rays and the lack of high-quality
data at that energy band. Recently, a 200 ks {\it NuSTAR} observation of Ark
564 in 3--50 keV band, revealed the presence of one of the coolest coronae with
temperature $kT_e \sim 15$ keV in the time-averaged spectrum. Here, we
re-analyse the data and examined the spectra in four flux levels. Our analysis
shows that the coronal temperature decreased from $\sim 17$ to $\sim 14$ keV as
the flux increased. The high energy photon index $\Gamma \sim 2.3$ varied by
less than $0.1$, implying that the optical depth of the corona increased by
about 10\% as the flux increased. This first reporting of coronal temperature
variation with flux shows that further long observation by {\it NuSTAR} of this
and other sources would shed light on the geometry and dynamics of the inner
regions of the accretion flow.
[2]
oai:arXiv.org:nucl-ex/0409017 [pdf] - 118463
Astrophysical S_{17}(0) factor from a measurement of d(7Be,8B)n reaction
at E_{c.m.} = 4.5 MeV
Das, J. J.;
Datar, V. M.;
Sugathan, P.;
Madhavan, N.;
Rao, P. V. Madhusudhana;
Jhingan, A.;
Navin, A.;
Dhiman, S. K.;
Barua, S.;
Nath, S.;
Varughese, T.;
Sinha, A. K.;
Singh, R.;
Ray, A.;
Sastry, D. L.;
Kulkarni, R. G.;
Shyam, R.
Submitted: 2004-09-21, last modified: 2006-02-23
Angular distribution measurements of $^2$H($^7$Be,$^7$Be)$^2$H and
$^2$H($^7$Be,$^8$B)$n$ reactions at $E_{c.m.}\sim$~4.5 MeV were performed to
extract the astrophysical $S_{17}(0)$ factor using the asymptotic normalization
coefficient (ANC) method. For this purpose a pure, low emittance $^7$Be beam
was separated from the primary $^7$Li beam by a recoil mass spectrometer
operated in a novel mode. A beam stopper at 0$^{\circ}$ allowed the use of a
higher $^7$Be beam intensity. Measurement of the elastic scattering in the
entrance channel using kinematic coincidence, facilitated the determination of
the optical model parameters needed for the analysis of the transfer data. The
present measurement significantly reduces errors in the extracted
$^7$Be(p,$\gamma$) cross section using the ANC method. We get
$S_{17}$~(0)~=~20.7~$\pm$~2.4 eV~b.