Normalized to: Barrentine, E.
[1]
oai:arXiv.org:1912.07118 [pdf] - 2050303
The Experiment for Cryogenic Large-aperture Intensity Mapping (EXCLAIM)
Ade, P. A. R.;
Anderson, C. J.;
Barrentine, E. M.;
Bellis, N. G.;
Bolatto, A. D.;
Breysse, P. C.;
Bulcha, B. T.;
Cataldo, G.;
Connors, J. A.;
Cursey, P. W.;
Ehsan, N.;
Grant, H. C.;
Essinger-Hileman, T. M.;
Hess, L. A.;
Kimball, M. O.;
Kogut, A. J.;
Lamb, A. D.;
Lowe, L. N.;
Mauskopf, P. D.;
McMahon, J.;
Mirzaei, M.;
Moseley, S. H.;
Mugge-Durum, J. W.;
Noroozian, O.;
Pen, U.;
Pullen, A. R.;
Rodriguez, S.;
Shirron, P. J.;
Somerville, R. S.;
Stevenson, T. R.;
Switzer, E. R.;
Tucker, C.;
Visbal, E.;
Volpert, C. G.;
Wollack, E. J.;
Yang, S.
Submitted: 2019-12-15
The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a
cryogenic balloon-borne instrument that will survey galaxy and star formation
history over cosmological time scales. Rather than identifying individual
objects, EXCLAIM will be a pathfinder to demonstrate an intensity mapping
approach, which measures the cumulative redshifted line emission. EXCLAIM will
operate at 420-540 GHz with a spectral resolution R=512 to measure the
integrated CO and [CII] in redshift windows spanning 0 < z < 3.5. CO and [CII]
line emissions are key tracers of the gas phases in the interstellar medium
involved in star-formation processes. EXCLAIM will shed light on questions such
as why the star formation rate declines at z < 2, despite continued clustering
of the dark matter. The instrument will employ an array of six superconducting
integrated grating-analog spectrometers (micro-spec) coupled to microwave
kinetic inductance detectors (MKIDs). Here we present an overview of the
EXCLAIM instrument design and status.
[2]
oai:arXiv.org:1411.1343 [pdf] - 1223020
Analysis and calibration techniques for superconducting resonators
Submitted: 2014-11-05, last modified: 2014-12-04
A method is proposed and experimentally explored for in-situ calibration of
complex transmission data for superconducting microwave resonators. This
cryogenic calibration method accounts for the instrumental transmission
response between the vector network analyzer reference plane and the device
calibration plane. Once calibrated, the observed resonator response is analyzed
in detail by two approaches. The first, a phenomenological model based on
physically realizable rational functions, enables the extraction of multiple
resonance frequencies and widths for coupled resonators without explicit
specification of the circuit network. In the second, an ABCD-matrix
representation for the distributed transmission line circuit is used to model
the observed response from the characteristic impedance and propagation
constant. When used in conjunction with electromagnetic simulations, the
kinetic inductance fraction can be determined with this method with an accuracy
of 2%. Datasets for superconducting microstrip and coplanar-waveguide resonator
devices were investigated and a recovery within 1% of the observed complex
transmission amplitude was achieved with both analysis approaches. The
experimental configuration used in microwave characterization of the devices
and self-consistent constraints for the electromagnetic constitutive relations
for parameter extraction are also presented.
[3]
oai:arXiv.org:1402.3601 [pdf] - 1203368
A Comparison of Fundamental Noise in Kinetic Inductance Detectors and
Transition Edge Sensors for Millimeter-wave Applications
Submitted: 2014-02-14
Kinetic inductance detectors (KIDs) show promise as a competitive technology
for astronomical observations over a wide range of wavelengths. We are
interested in comparing the fundamental limitations to the sensitivity of KIDs
with that of transition edge sensors (TESs) at millimeter wavelengths,
specifically over the wavelengths required for studies of the Cosmic Microwave
Background (CMB). We calculate the total fundamental noise arising from optical
and thermal excitations in TESs and KIDs for a variety of bath temperatures and
optical loading scenarios for applications at millimeter wavelengths. Special
consideration is given to the case of ground-based observations of 100 GHz
radiation with a 100 mK bath temperature, conditions consistent with the
planned second module of the QUBIC telescope, a CMB instrument. Under these
conditions, a titanium nitride KID with optimized critical temperature pays a
few percent noise penalty compared to a typical optimized TES.