Normalized to: Barillot, M.
[1]
oai:arXiv.org:1109.3131 [pdf] - 1521897
Current results of the PERSEE testbench: the cophasing control and the
polychromatic null rate
Lozi, Julien;
Cassaing, Frederic;
Duigou, Jean-Michel Le;
Sorrente, Beatrice;
Montri, Jospeh;
Reess, Jean-Michel;
Lhome, Emilie;
Buey, Tristan;
Henault, Francois;
Marcotto, Aurelie;
Girard, Paul;
Barillot, Marc;
Ollivier, Marc;
Foresto, Vincent Coude du
Submitted: 2011-09-14
Stabilizing a nulling interferometer at a nanometric level is the key issue
to obtain deep null depths. The PERSEE breadboard has been designed to study
and optimize the operation of a cophased nulling bench in the most realistic
disturbing environment of a space mission. This presentation focuses on the
current results of the PERSEE bench. In terms of metrology, we cophased at 0.33
nm rms for the piston and 80 mas rms for the tip/tilt (0.14% of the Airy disk).
A Linear Quadratic Gaussian (LQG) control coupled with an unsupervised
vibration identification allows us to maintain that level of correction, even
with characteristic vibrations of nulling interferometry space missions. These
performances, with an accurate design and alignment of the bench, currently
lead to a polychromatic unpolarised null depth of 8.9E-6 stabilized at 3E-7 on
the [1.65-2.45] \mum spectral band (37% bandwidth).
[2]
oai:arXiv.org:1008.3081 [pdf] - 216046
PERSEE: Experimental results on the cophased nulling bench
Lozi, Julien;
Cassaing, Frédéric;
Duigou, Jean-Michel Le;
Houairi, Kamel;
Sorrente, Béatrice;
Montri, Joseph;
Jacquinod, Sophie;
Reess, Jean-Michel;
Pham, Laurie;
Lhomé, Emilie;
Buey, Tristan;
Hénault, François;
Marcotto, Aurélie;
Girard, Paul;
Mauclert, Nicolas;
Barillot, Marc;
Foresto, Vincent Coudé du;
Ollivier, Marc
Submitted: 2010-08-18
Nulling interferometry is still a promising method to characterize spectra of
exoplanets. One of the main issues is to cophase at a nanometric level each arm
despite satellite disturbances. The bench PERSEE aims to prove the feasibility
of that technique for spaceborne missions. After a short description of PERSEE,
we will first present the results obtained in a simplified configuration: we
have cophased down to 0.22 nm rms in optical path difference (OPD) and 60 mas
rms in tip/tilt, and have obtained a monochromatic null of 3E-5 stabilized at
3E-6. The goal of 1 nm with additional typical satellite disturbances requires
the use of an optimal control law; that is why we elaborated a dedicated Kalman
filter. Simulations and experiments show a good rejection of disturbances.
Performance of the bench should be enhanced by using a Kalman control law, and
we should be able to reach the desired nanometric stability. Following, we will
present the first results of the final polychromatic configuration, which
includes an achromatic phase shifter, perturbators and optical delay lines. As
a conclusion, we give the first more general lessons we have already learned
from this experiment, both at system and component levels for a future space
mission.
[3]
oai:arXiv.org:0812.1901 [pdf] - 19342
Tests of achromatic phase shifters performed on the SYNAPSE test bench:
a progress report
Gabor, Pavel;
Schuller, Peter A.;
Chazelas, Bruno;
Decaudin, Michel;
Labèque, Alain;
Duret, Philippe;
Rabbia, Yves;
Launhardt, Ralf;
Gay, Jean;
Sodnik, Zoran;
Barillot, Marc;
Brachet, Frank;
Laurent, Thomas;
Jacquinod, Sophie;
Vandormael, Denis;
Loicq, Jérôme;
Mawet, Dimitri;
Ollivier, Marc;
Léger, Alain
Submitted: 2008-12-10
The achromatic phase shifter (APS) is a component of the Bracewell nulling
interferometer studied in preparation for future space missions (viz.
Darwin/TPF-I) focusing on spectroscopic study of Earth-like exo-planets.
Several possible designs of such an optical subsystem exist. Four approaches
were selected for further study. Thales Alenia Space developed a dielectric
prism APS. A focus crossing APS prototype was developed by the OCA, Nice,
France. A field reversal APS prototype was prepared by the MPIA in Heidelberg,
Germany. Centre Spatial de Li\`ege develops a concept based on Fresnel's
rhombs. This paper presents a progress report on the current work aiming at
evaluating these prototypes on the SYNAPSE test bench at the Institut
d'Astrophysique Spatiale in Orsay, France.
[4]
oai:arXiv.org:0709.2563 [pdf] - 5025
Nulling interferometry: performance comparison between Antarctica and
other ground-based sites
Submitted: 2007-09-17
Detecting the presence of circumstellar dust around nearby solar-type main
sequence stars is an important pre-requisite for the design of future
life-finding space missions such as ESA's Darwin or NASA's Terrestrial Planet
Finder (TPF). The high Antarctic plateau may provide appropriate conditions to
perform such a survey from the ground. We investigate the performance of a
nulling interferometer optimised for the detection of exozodiacal discs at Dome
C, on the high Antarctic plateau, and compare it to the expected performance of
similar instruments at temperate sites. Based on the currently available
measurements of the turbulence characteristics at Dome C, we adapt the GENIEsim
software (Absil et al. 2006, A&A 448) to simulate the performance of a nulling
interferometer on the high Antarctic plateau. To feed a realistic instrumental
configuration into the simulator, we propose a conceptual design for ALADDIN,
the Antarctic L-band Astrophysics Discovery Demonstrator for Interferometric
Nulling. We assume that this instrument can be placed above the 30-m high
boundary layer, where most of the atmospheric turbulence originates. We show
that an optimised nulling interferometer operating on a pair of 1-m class
telescopes located 30 m above the ground could achieve a better sensitivity
than a similar instrument working with two 8-m class telescopes at a temperate
site such as Cerro Paranal. The detection of circumstellar discs about 20 times
as dense as our local zodiacal cloud seems within reach for typical Darwin/TPF
targets in a integration time of a few hours. Moreover, the exceptional
turbulence conditions significantly relax the requirements on real-time control
loops, which has favourable consequences on the feasibility of the nulling
instrument.