Normalized to: Barbosa, H.
[2]
oai:arXiv.org:astro-ph/0509496 [pdf] - 76078
Lateral width of shower image in the Auger fluorescence detector
Barbosa, H.;
de Souza, V.;
Dobrigkeit, C.;
Engel, R.;
Gora, D.;
Heck, D.;
Homola, P.;
Klages, H.;
Medina-Tanco, G.;
Ortiz, J. A.;
Pekala, J.;
Risse, M.;
Wilczynska, B.;
Wilczynski, H.
Submitted: 2005-09-16
The impact of the lateral distribution of light in extensive air showers on
the detection and reconstruction of shower profiles is investigated for the
Auger fluorescence telescopes. Based on three-dimensional simulations, the
capability of the Auger telescopes to measure the lateral distribution of light
is evaluated. The ability to infer the actual lateral distribution is confirmed
by the comparison of detailed simulations with real data. The contribution of
pixels located far from the axis of the shower image is calculated and the
accepted signal is rescaled in order to reconstruct a correct shower profile.
The analysis presented here shows that: (a) the Auger telescopes are able to
observe the lateral distribution of showers and (b) the energy corrections to
account for the signal in outlying pixels can exceed 10%, depending on shower
geometry.
[3]
oai:arXiv.org:astro-ph/0310234 [pdf] - 59897
Determination of the calorimetric energy in extensive air showers
Submitted: 2003-10-08, last modified: 2004-09-30
The contribution of different components of an air shower to the total energy
deposit in the atmosphere, for different angles and primary particles, was
studied using the CORSIKA air shower simulation code. The amount of missing
energy, parameterized in terms of the calorimetric energy, was calculated. The
results show that this parameterization varies less than 1% with angle or
observation level. The dependence with the primary mass is less than 5% and,
with the high energy hadronic interaction model, less than 2%. The systematic
error introduced by the use of just one parameterization of the missing energy
correction function, for an equal mixture of proton and iron at 45deg, was
calculated to be below 3%. We estimate the statistical error due to
shower-to-shower fluctuations to be about 1%.
[4]
oai:arXiv.org:astro-ph/0311201 [pdf] - 60781
Air shower fluorescence light simulations
Submitted: 2003-11-09, last modified: 2004-09-30
A new approach to simulate fluorescence photons produced in extensive air
showers is described. A Monte Carlo program based on CORSIKA produces the
fluorescence photons for each charged particle in the development of the
shower. This method results in a full three-dimensional simulation of the
particles in a shower and of the fluorescence light generated in the
atmosphere. The photons produced by this program are tracked down to a
telescope and the simulation of a particular detector is applied. The
differences between this method and one-dimensional approaches are
quantitatively determined as a function of the distance between the telescope
and the shower core. As a particular application, the maximum distance at which
the Auger fluorescence telescope might be able to measure the lateral
distribution of a shower is determined as a function of energy.