Normalized to: Barbeau, P.
[1]
oai:arXiv.org:1903.03663 [pdf] - 1920852
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
Gallina, G.;
Giampa, P.;
Retiere, F.;
Kroeger, J.;
Zhang, G.;
Ward, M.;
Margetak, P.;
Lic, G.;
Tsang, T.;
Doria, L.;
Kharusi, S. Al;
Alfaris, M.;
Anton, G.;
Arnquist, I. J.;
Badhrees, I.;
Barbeau, P. S.;
Beck, D.;
Belov, V.;
Bhatta, T.;
Blatchford, J.;
Brodsky, J. P.;
Brown, E.;
Brunner, T.;
Cao, G. F.;
Cao, L.;
Cen, W. R.;
Chambers, C.;
Charlebois, S. A.;
Chiu, M.;
Cleveland, B.;
Coon, M.;
Craycraft, A.;
Dalmasson, J.;
Daniels, T.;
Darroch, L.;
Daugherty, S. J.;
Croix, A. De St.;
Der Mesrobian-Kabakian, A.;
DeVoe, R.;
Dilling, J.;
Ding, Y. Y.;
Dolinski, M. J.;
Dragone, A.;
Echevers, J.;
Elbeltagi, M.;
Fabris, L.;
Fairbank, D.;
Fairbank, W.;
Farine, J.;
Feyzbakhsh, S.;
Fontaine, R.;
Gautam, P.;
Giacomini, G.;
Gornea, R.;
Gratta, G.;
Hansen, E. V.;
Heffner, M.;
Hoppe, E. W.;
Hoßl, J.;
House, A.;
Hughes, M.;
Ito, Y.;
Iverson, A.;
Jamil, A.;
Jewell, M. J.;
Jiang, X. S.;
Karelin, A.;
Kaufman, L. J.;
Kodroff, D.;
Koffas, T.;
Krucken, R.;
Kuchenkov, A.;
Kumar, K. S.;
Lana, Y.;
Larson, A.;
Lenardo, B. G.;
Leonarda, D. S.;
Lik, S.;
Li, Z.;
Licciardi, C.;
Linw, Y. H.;
Lv, P.;
MacLellan, R.;
McElroy, T.;
Medina-Peregrina, M.;
Michel, T.;
Mong, B.;
Moore, D. C.;
Murray, K.;
Nakarmi, P.;
Newby, R. J.;
Ning, Z.;
Njoya, O.;
Nolet, F.;
Nusair, O.;
Odgers, K.;
Odian, A.;
Oriunno, M.;
Orrell, J. L.;
Ortega, G. S.;
Ostrovskiy, I.;
Overman, C. T.;
Parent, S.;
Piepkez, A.;
Pocar, A.;
Pratte, J. -F.;
Qiu, D.;
Radeka, V.;
Raguzin, E.;
Rescia, S.;
Richman, M.;
Robinson, A.;
Rossignol, T.;
Rowson, P. C.;
Roy, N.;
Saldanha, R.;
Sangiorgio, S.;
VIII, K. Skarpaas;
Soma, A. K.;
St-Hilaire, G.;
Stekhanov, V.;
Stiegler, T.;
Sun, X. L.;
Tarka, M.;
Todd, J.;
Tolba, T.;
Totev, T. I.;
Tsang, R.;
Vachon, F.;
Veeraraghavan, V.;
Visser, G.;
Vuilleumier, J. -L.;
Wagenpfeil, M.;
Walent, M.;
Wang, Q.;
Watkins, J.;
Weber, M.;
Wei, W.;
Wen, L. J.;
Wichoski, U.;
Wu, S. X.;
Wu, W. H.;
Wu, X.;
Xia, Q.;
Yang, H.;
Yang, L.;
Yen, Y. -R.;
Zeldovich, O.;
Zhao, J.;
Zhou, Y.;
Ziegler, T.
Submitted: 2019-03-08, last modified: 2019-06-07
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N:
S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers
(SiPMs) as part of the development of a solution for the detection of liquid
xenon scintillation light for the nEXO experiment. Various SiPM features, such
as: dark noise, gain, correlated avalanches, direct crosstalk and Photon
Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs
were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233
\text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163
\text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse
in the $1 \upmu\text{s}$ interval following the trigger pulse of
$0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is
$0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are
within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two
different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of
$189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we
report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a
saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both
values are well below the $24\text{ }\%$ saturation PDE advertised by
Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over
voltage is below the nEXO PDE requirement. The first one instead yields a PDE
that is marginally close to meeting the nEXO specifications. This suggests that
with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an
alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
[2]
oai:arXiv.org:1804.06457 [pdf] - 1762928
Liquid Scintillator Response to Proton Recoils in the 10-100 keV Range
Submitted: 2018-04-17, last modified: 2018-05-07
We study the response of EJ-301 liquid scintillator to monochromatic 244.6
$\pm$ 8.4 keV neutrons, targeting the 10-100 keV proton recoil energy interval.
Limited experimental information exists for proton light yield in this range,
for this or any other organic scintillator. Our results confirm the adequacy of
a modified Birks' model, common to all organic scintillator formulations,
predicting a marked increase in quenching factor as proton energy approaches
the few keV regime. The relevance of this behavior within the context of
searches for low-mass particle dark matter is mentioned.
[4]
oai:arXiv.org:1401.6234 [pdf] - 931856
Maximum Likelihood Signal Extraction Method Applied to 3.4 years of
CoGeNT Data
Aalseth, C. E.;
Barbeau, P. S.;
Leon, J. Diaz;
Fast, J. E.;
Hossbach, T. W.;
Knecht, A.;
Kos, M. S.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.
Submitted: 2014-01-23, last modified: 2015-02-05
CoGeNT has taken data for over 3 years, with 1136 live days of data
accumulated as of April 23, 2013. We report on the results of a maximum
likelihood analysis to extract any possible dark matter signal present in the
collected data. The maximum likelihood signal extraction uses 2-dimensional
probability density functions (PDFs) to characterize the anticipated variations
in dark matter interaction rates for given observable nuclear recoil energies
during differing periods of the Earth's annual orbit around the Sun. Cosmogenic
and primordial radioactivity backgrounds are characterized by their energy
signatures and in some cases decay half-lives. A third parameterizing variable
-- pulse rise-time -- is added to the likelihood analysis to characterize slow
rising pulses described in prior analyses. The contribution to each event
category is analyzed for various dark matter signal hypotheses including a dark
matter standard halo model and a case with free oscillation parameters (i.e.,
amplitude, period, and phase). The best-fit dark matter signal is in close
proximity to previously reported results. We find that the significance of the
extracted dark matter signal remains well below evidentiary at 1.7 $\sigma$.
[5]
oai:arXiv.org:1409.3185 [pdf] - 903705
Comment on "Fitting the annual modulation in DAMA with neutrons from
muons and neutrinos''
Submitted: 2014-09-10
We estimate rates of solar neutrino-induced neutrons in a DAMA/LIBRA-like
detector setup, and find that the needed contribution to explain the annual
modulation would require neutrino-induced neutron cross sections several orders
of magnitude larger than current calculations indicate. Although these cross
sections have never been measured, it is likely that the solar-neutrino effect
on DAMA/LIBRA is negligible.
[6]
oai:arXiv.org:1401.3295 [pdf] - 770398
Search for An Annual Modulation in Three Years of CoGeNT Dark Matter
Detector Data
Aalseth, C. E.;
Barbeau, P. S.;
Colaresi, J.;
Collar, J. I.;
Leon, J. Diaz;
Fast, J. E.;
Fields, N. E.;
Hossbach, T. W.;
Knecht, A.;
Kos, M. S.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.;
Yocum, K. M.
Submitted: 2014-01-14
Weakly Interacting Massive Particles (WIMPs) are well-established dark matter
candidates. WIMP interactions with sensitive detectors are expected to display
a characteristic annual modulation in rate. We release a dataset spanning 3.4
years of operation from a low-background germanium detector, designed to search
for this signature. A previously reported modulation persists, concentrated in
a region of the energy spectrum populated by an exponential excess of unknown
origin. Its phase and period agree with phenomenological expectations, but its
amplitude is a factor $\sim$4-7 larger than predicted for a standard WIMP
galactic halo. We consider the possibility of a non-Maxwellian local halo
velocity distribution as a plausible explanation, able to help reconcile
recently reported WIMP search anomalies.
[7]
oai:arXiv.org:1208.5737 [pdf] - 690015
CoGeNT: A Search for Low-Mass Dark Matter using p-type Point Contact
Germanium Detectors
Aalseth, C. E.;
Barbeau, P. S.;
Colaresi, J.;
Collar, J. I.;
Leon, J. Diaz;
Fast, J. E.;
Fields, N. E.;
Hossbach, T. W.;
Knecht, A.;
Kos, M. S.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.;
Yocum, K. M.
Submitted: 2012-08-28, last modified: 2013-04-29
CoGeNT employs p-type point-contact (PPC) germanium detectors to search for
Weakly Interacting Massive Particles (WIMPs). By virtue of its low energy
threshold and ability to reject surface backgrounds, this type of device allows
an emphasis on low-mass dark matter candidates (wimp mass of about 10 GeV/c2).
We report on the characteristics of the PPC detector presently taking data at
the Soudan Underground Laboratory, elaborating on aspects of shielding, data
acquisition, instrumental stability, data analysis, and background estimation.
A detailed background model is used to investigate the low energy excess of
events previously reported, and to assess the possibility of temporal
modulations in the low-energy event rate. Extensive simulations of all
presently known backgrounds do not provide a viable background explanation for
the excess of low-energy events in the CoGeNT data, or the previously observed
temporal variation in the event rate. Also reported on for the first time is a
determination of the surface (slow pulse rise time) event contamination in the
data as a function of energy. We conclude that the CoGeNT detector technology
is well suited to search for the annual modulation signature expected from dark
matter particle interactions in the region of WIMP mass and coupling favored by
the DAMA/LIBRA results
[8]
oai:arXiv.org:1106.0650 [pdf] - 669552
Search for an Annual Modulation in a P-type Point Contact Germanium Dark
Matter Detector
Aalseth, C. E.;
Barbeau, P. S.;
Colaresi, J.;
Collar, J. I.;
Leon, J. Diaz;
Fast, J. E.;
Fields, N.;
Hossbach, T. W.;
Keillor, M. E.;
Kephart, J. D.;
Knecht, A.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.;
Radford, D. C.;
Wilkerson, J. F.;
Yocum, K. M.
Submitted: 2011-06-03, last modified: 2011-10-04
Fifteen months of cumulative CoGeNT data are examined for indications of an
annual modulation, a predicted signature of Weakly Interacting Massive Particle
(WIMP) interactions. Presently available data support the presence of a
modulated component of unknown origin, with parameters prima facie compatible
with a galactic halo composed of light-mass WIMPs. Unoptimized estimators yield
a statistical significance for a modulation of ~2.8 sigma, limited by the short
exposure.
[9]
oai:arXiv.org:1002.4703 [pdf] - 339357
Results from a Search for Light-Mass Dark Matter with a P-type Point
Contact Germanium Detector
Aalseth, C. E.;
Barbeau, P. S.;
Bowden, N. S.;
Cabrera-Palmer, B.;
Colaresi, J.;
Collar, J. I.;
Dazeley, S.;
de Lurgio, P.;
Drake, G.;
Fast, J. E.;
Fields, N.;
Greenberg, C. H.;
Hossbach, T. W.;
Keillor, M. E.;
Kephart, J. D.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.;
Radford, D. C.;
Reyna, D.;
Robertson, R. G. H.;
Talaga, R. L.;
Tench, O.;
Van Wechel, T. D.;
Wilkerson, J. F.;
Yocum, K. M.
Submitted: 2010-02-25, last modified: 2010-03-15
We report on several features present in the energy spectrum from an ultra
low-noise germanium detector operated at 2,100 m.w.e. By implementing a new
technique able to reject surface events, a number of cosmogenic peaks can be
observed for the first time. We discuss several possible causes for an
irreducible excess of bulk-like events below 3 keVee, including a dark matter
candidate common to the DAMA/LIBRA annual modulation effect, the hint of a
signal in CDMS, and phenomenological predictions. Improved constraints are
placed on a cosmological origin for the DAMA/LIBRA effect.
[10]
oai:arXiv.org:0806.1341 [pdf] - 13353
Additional Comments on "New Limits on Spin-Independent Couplings of
Low-Mass WIMP Dark Matter with a Germanium Detector at a Threshold of 200 eV"
Submitted: 2008-06-08, last modified: 2008-08-09
In a previous comment (arXiv:0806.1341v1) we criticized purely technical
aspects of arXiv:0712.1645 but pointed out that many other inconsistencies were
readily apparent. In view of the imminent posting of another version of
arXiv:0712.1645, still containing these issues, we would like to offer with
this additional note a critical guide to the methodology followed by the TEXONO
collaboration, in their effort to extract dark matter limits from a spectral
region completely dominated by electronic noise. We find that systematics have
been neglected through a combination of erroneous assumptions and failure to
explore all of their possible sources.
[11]
oai:arXiv.org:0807.0879 [pdf] - 14236
Experimental constraints on a dark matter origin for the DAMA annual
modulation effect
Aalseth, C. E.;
Barbeau, P. S.;
Cerdeno, D. G.;
Colaresi, J.;
Collar, J. I.;
de Lurgio, P.;
Drake, G.;
Fast, J. E.;
Greenberg, C. H.;
Hossbach, T. W.;
Kephart, J. D.;
Marino, M. G.;
Miley, H. S.;
Orrell, J. L.;
Reyna, D.;
Robertson, R. G. H.;
Talaga, R.;
Tench, O.;
Van Wechel, T. D.;
Wilkerson, J. F.;
Yocum, K. M.
Submitted: 2008-07-05, last modified: 2008-07-31
A claim for evidence of dark matter interactions in the DAMA experiment has
been recently reinforced. We employ a new type of germanium detector to
conclusively rule out a standard isothermal galactic halo of Weakly Interacting
Massive Particles (WIMPs) as the explanation for the annual modulation effect
leading to the claim. Bounds are similarly imposed on a suggestion that dark
pseudoscalars mightlead to the effect. We describe the sensitivity to light
dark matter particles achievable with our device, in particular to
Next-to-Minimal Supersymmetric Model candidates.
[12]
oai:arXiv.org:nucl-ex/0701012 [pdf] - 358365
Large-Mass Ultra-Low Noise Germanium Detectors: Performance and
Applications in Neutrino and Astroparticle Physics
Submitted: 2007-01-07
A new type of radiation detector, a p-type modified electrode germanium
diode, is presented. The prototype displays, for the first time, a combination
of features (mass, energy threshold and background expectation) required for a
measurement of coherent neutrino-nucleus scattering in a nuclear reactor
experiment. The device hybridizes the mass and energy resolution of a
conventional HPGe coaxial gamma spectrometer with the low electronic noise and
threshold of a small x-ray semiconductor detector, also displaying an intrinsic
ability to distinguish multiple from single-site particle interactions. The
present performance of the prototype and possible further improvements are
discussed, as well as other applications for this new type of device in
neutrino and astroparticle physics (double-beta decay, neutrino magnetic moment
and WIMP searches).
[13]
oai:arXiv.org:nucl-ex/0701011 [pdf] - 118490
Design and Characterization of a Neutron Calibration Facility for the
Study of sub-keV Nuclear Recoils
Submitted: 2007-01-06
As part of an experimental effort to demonstrate sensitivity in a large-mass
detector to the ultra-low energy recoils expected from coherent
neutrino-nucleus elastic scattering, we have designed and built a highly
monochromatic 24 keV neutron beam at the Kansas State University Triga Mark-II
reactor. The beam characteristics were chosen so as to mimic the soft recoil
energies expected from reactor antineutrinos in a variety of targets, allowing
to understand the response of dedicated detector technologies in this yet
unexplored sub-keV recoil range. A full characterization of the beam properties
(intensity, monochromaticity, contaminations, beam profile) is presented,
together with first tests of the calibration setup using proton recoils in
organic scintillator.
[14]
oai:arXiv.org:hep-ex/0304013 [pdf] - 358345
A First Mass Production of Gas Electron Multipliers
Submitted: 2003-04-07
We report on the manufacture of a first batch of approximately 2,000 Gas
Electron Multipliers (GEMs) using 3M's fully automated roll to roll flexible
circuit production line. This process allows low-cost, reproducible fabrication
of a high volume of GEMs of dimensions up to 30$\times$30 cm$^{2}$. First tests
indicate that the resulting GEMs have optimal properties as radiation
detectors. Production techniques and preliminary measurements of GEM
performance are described. This now demonstrated industrial capability should
help further establish the prominence of micropattern gas detectors in
accelerator based and non-accelerator particle physics, imaging and
photodetection.
[15]
oai:arXiv.org:hep-ex/0212034 [pdf] - 358344
Towards Coherent Neutrino Detection Using Low-Background Micropattern
Gas Detectors
Submitted: 2002-12-13
The detection of low energy neutrinos ($<$ few tens of MeV) via coherent
nuclear scattering remains a holy grail of sorts in neutrino physics. This
uncontroversial mode of interaction is expected to profit from a sizeable
increase in cross section proportional to neutron number squared in the target
nucleus, an advantageous feature in view of the small probability of
interaction via all other channels in this energy region. A coherent neutrino
detector would open the door to many new applications, ranging from the study
of fundamental neutrino properties to true "neutrino technology".
Unfortunately, present-day radiation detectors of sufficiently large mass ($>$
1 kg) are not sensitive to sub-keV nuclear recoils like those expected from
this channel. The advent of Micropattern Gas Detectors (MPGDs), new
technologies originally intended for use in High Energy Physics, may soon put
an end to this impasse. We present first tests of MPGDs fabricated with
radioclean materials and discuss the approach to assessing their sensitivity to
these faint signals. Applications are reviewed, in particular their use as a
safeguard against illegitimate operation of nuclear reactors. A first
industrial mass production of Gas Electron Multipliers (GEMs) is succinctly
described.