Normalized to: Barão, F.
[1]
oai:arXiv.org:1908.09945 [pdf] - 1949455
The sub-TeV transient Gamma-Ray sky: challenges and opportunities
La Mura, G.;
Assis, P.;
Blanco, A.;
Conceição, R.;
Fonte, P.;
Lopes, L.;
Pimenta, M.;
Tomé, B.;
Santo, C. Espírito;
Mendes, L.;
Ferreira, M.;
Abreu, P.;
Brogueira, P.;
Mendes, L. Filipe;
Barão, F.;
de Almeida, U. Barres;
Shellard, R. C.;
Giaccari, U.;
Lippmann, O.;
Piazzoli, B. D'Ettorre;
Doro, M.;
Prandini, E.;
Perennes, C.;
Matthiae, G.;
Tavani, M.;
Santonico, R.;
De Angelis, A.;
Coto, R. Lopez;
Chiavassa, A.;
Vícha, J.;
Trávničék, P.;
Di Sciascio, G.
Submitted: 2019-08-26
The detection of gravitational waves and neutrinos from astrophysical sources
with gamma-ray counterparts officially started the era of Multi-Messenger
Astronomy. Their transient and extreme nature implies that monitoring the VHE
sky is fundamental to investigate the non-electromagnetic signals. However, the
limited effective area of space-borne instruments prevents observations above a
few hundred GeV, while the small field of view and low duty cycle of IACTs make
them unsuited for extensive monitoring activities and prompt response to
transients. Extensive Air Shower arrays (EAS) can provide a large field of
view, a wide effective area and a very high duty cycle. Their main difficulty
is the distinction between gamma-ray and cosmic-ray initiated air showers,
especially below the TeV range. Here we present some case studies stressing the
importance that a new EAS array in the Southern Hemisphere will be able to
survey the sky from below 100 GeV up to several TeV. In the energy domain
between 100 and 400 GeV we expect the strongest electromagnetic signatures of
the acceleration of ultra-relativistic particles in sources like SNRs, blazar
jets and gamma-ray bursts, as recently proved by IACT observations. This
spectral window is also crucial to understand the Universe opacity to high
energy radiation, thus providing constraints on the cosmological parameters. We
will discuss the implications of VHE radiation on the mechanisms at work and we
will focus on the advantages resulting from the ability to monitor the energy
window lying between the domain of space-borne detectors and ground-based
facilities.
[2]
oai:arXiv.org:1906.11477 [pdf] - 1908133
Numerical modeling of cosmic-ray transport in the heliosphere and
interpretation of the proton-to-helium ratio in Solar Cycle 24
Submitted: 2019-06-27, last modified: 2019-06-28
Thanks to space-borne experiments of cosmic-ray (CR) detection, such as the
AMS and PAMELA missions in low-Earth orbit, or the Voyager-1 spacecraft in the
interstellar space, a large collection of multi-channel and time-resolved CR
data has become available. Recently, the AMS experiment has released new
precision data, on the proton and helium fluxes in CRs, measured on monthly
basis during its first six years of mission. The AMS data reveal a remarkable
long-term behavior in the temporal evolution of the proton-to-helium ratio at
rigidity $R = p/Z <$ 3 GV. As we have argued in a recent work, such a behavior
may reflect the transport properties of low-rigidity CRs in the inteplanetary
space. In particular, it can be caused by mass/charge dependence of the CR
diffusion coefficient. In this paper, we present our developments in the
numerical modeling of CR transport in the Milky Way and in the heliosphere.
Within our model, and with the help of approximated analytical solutions, we
describe in details the relations between the properties of CR diffusion and
the time-dependent evolution of the proton-to-helium ratio.
[3]
oai:arXiv.org:1811.08909 [pdf] - 1802824
Testing diffusion of cosmic rays in the heliosphere with proton and
helium data from AMS
Submitted: 2018-11-21, last modified: 2018-12-21
After six years of continuous observations in space, the Alpha Magnetic
Spectrometer experiment has released new data on the temporal evolution of the
proton and helium fluxes in cosmic rays. These data revealed that the ratio
between proton and helium fluxes at the same value of rigidity $R=p/Z$
(momentum/charge ratio) is not constant at $R\lesssim$ 3 GV. In particular, the
ratio is found to decrease steadily during the descending phase of Solar Cycle
24 toward the next minimum. We show that such a behavior is a remarkable
signature of the $\beta\times\lambda(R)$ dependence in the diffusion of cosmic
rays in heliosphere, where $\beta$ is their adimensional speed and $\lambda(R)$
is their mean free path, a universal function of rigidity for all nuclei. This
dependence is responsible for distinctive charge/mass dependent effects in the
time-dependent modulation of low-rigidity particles.
[4]
oai:arXiv.org:1810.10530 [pdf] - 1886435
Observation of a time lag in solar modulation of cosmic rays in the
heliosphere
Submitted: 2018-10-23
The solar modulation effect of Galactic cosmic rays is a time-dependent
phenomenon that is caused by the transport of these particles through the
magnetized plasma of the heliosphere. Using a data-driven model of cosmic-ray
transport in the heliosphere, in combination with a large collection of data,
we report the evidence for a eight-month time lag between observations of solar
activity and measurements of cosmic-ray fluxes in space. As we will discuss,
this result enables us to forecast the cosmic ray flux at Earth well in advance
by monitoring solar activity. We also compare our predictions with the new
multi-channel measurements of cosmic rays operated by the AMS experiment in
space.
[5]
oai:arXiv.org:0802.0110 [pdf] - 9662
Velocity and charge reconstruction with the AMS/RICH detector
Submitted: 2008-02-01
The Alpha Magnetic Spectrometer (AMS), to be installed on the International
Space Station (ISS) in 2008, will be equipped with a proximity focusing Ring
Imaging CHerenkov detector (RICH). This detector will be equipped with a dual
radiator (aerogel+NaF), a lateral conical mirror and a detection plane made of
680 photomultipliers and light-guides, enabling measurements of particle
electric charge and velocity. A likelihood method for the Cherenkov angle
reconstruction was applied leading to a velocity determination for protons with
a resolution around 0.1%. The electric charge reconstruction is based on the
counting of the number of photoelectrons and on an overall efficiency
estimation on an event-by-event basis. Results from the application of both
methods are presented.
[6]
oai:arXiv.org:0801.4957 [pdf] - 9635
AMS - a magnetic spectrometer on the international space station
Submitted: 2008-01-31
The Alpha Magnetic Spectrometer (AMS) is a particle detector, designed to
search for cosmic antimatter and dark matter and to study the elemental and
isotopic composition of primary cosmic rays, that will be installed on the
International Space Station (ISS) in 2008 to operate for at least three years.
The detector will be equipped with a ring imaging Cherenkov detector (RICH)
enabling measurements of particle electric charge and velocity with
unprecedented accuracy. Physics prospects and test beam results are shortly
presented.
[7]
oai:arXiv.org:0801.4952 [pdf] - 9632
Cosmic ray velocity and electric charge measurements with the AMS/RICH
detector: prototype results
Submitted: 2008-01-31
The Alpha Magnetic Spectrometer (AMS) to be installed on the International
Space Station (ISS) will measure charged cosmic ray spectra of elements up to
iron, in the rigidity range from 1 GV to 1 TV, for at least three years. AMS is
a large angular spectrometer composed of different subdetectors, including a
proximity focusing Ring Imaging CHerenkov (RICH) detector. This will be
equipped with a mixed radiator made of aerogel and sodium fluoride (NaF), a
lateral conical mirror and a detection plane made of 680 photomultipliers
coupled to light guides. The RICH detector allows measurements of particle's
electric charge up to iron, and particle's velocity. Two possible methods for
reconstructing the Cherenkov angle and the electric charge with the RICH will
be discussed.
A RICH prototype consisting of a detection matrix with 96 photomultipliers, a
segment of a conical mirror and samples of the radiator materials was built and
its performance was evaluated using ion beam data. Results from the last test
beam performed with ion fragments resulting from the collision of a 158
GeV/c/nucleon primary beam of indium ions (CERN SPS) on a lead target are
reported. The large amount of collected data allowed to test and characterize
different aerogel samples and the NaF radiator. In addition, the reflectivity
of the mirror was evaluated. The data analysis confirms the design goals.
[8]
oai:arXiv.org:0801.4658 [pdf] - 9561
Isotopic mass separation with the RICH detector of the AMS Experiment
Submitted: 2008-01-30
The Alpha Magnetic Spectrometer (AMS) to be installed on the International
Space Station (ISS) will be equipped with a proximity focusing Ring Imaging
Cerenkov detector (RICH). Reconstruction of the Cerenkov angle and the electric
charge with RICH are discussed. A likelihood method for the Cerenkov angle
reconstruction was applied leading to a velocity determination for protons with
a resolution around 0.1%. The electric charge reconstruction is based on the
counting of the number of photoelectrons and on an overall efficiency
estimation on an event-by-event basis. The isotopic mass separation of helium
and beryllium is presented.
[9]
oai:arXiv.org:0801.4484 [pdf] - 268578
The Ring Imaging Cherenkov detector of the AMS experiment: test beam
results with a prototype
Submitted: 2008-01-29
The Alpha Magnetic Spectrometer (AMS) to be installed on the International
Space Station (ISS) will be equipped with a proximity Ring Imaging Cherenkov
(RICH) detector for measuring the velocity and electric charge of the charged
cosmic particles. This detector will contribute to the high level of redundancy
required for AMS as well as to the rejection of albedo particles. Charge
separation up to iron and a velocity resolution of the order of 0.1% for singly
charged particles are expected. A RICH protoptype consisting of a detection
matrix with 96 photomultiplier units, a segment of a conical mirror and samples
of the radiator materials was built and its performance was evaluated. Results
from the last test beam performed with ion fragments resulting from the
collision of a 158 GeV/c/nucleon primary beam of indium ions (CERN SPS) on a
lead target are reported. The large amount of collected data allowed to test
and characterize different aerogel samples and the sodium fluoride radiator. In
addition, the reflectivity of the mirror was evaluated. The data analysis
confirms the design goals.
[10]
oai:arXiv.org:0801.3243 [pdf] - 9234
Particle identification with the AMS-02 RICH detector: D/p and
anti-D/anti-p separation
Submitted: 2008-01-21
The Alpha Magnetic Spectrometer (AMS), whose final version AMS-02 is to be
installed on the International Space Station (ISS) for at least 3 years, is a
detector designed to measure charged cosmic ray spectra with energies up to the
TeV region and with high energy photon detection capability up to a few hundred
GeV, using state-of-the art particle identification techniques. Among several
detector subsystems, AMS includes a proximity focusing RICH enabling precise
measurements of particle electric charge and velocity. The combination of both
these measurements together with the particle rigidity measured on the silicon
tracker endows a reliable measurement of the particle mass. The main topics of
the AMS-02 physics program include detailed measurements of the nuclear
component of the cosmic-ray spectrum and the search for indirect signatures of
dark matter. Mass separation of singly charged particles, and in particular the
separation of deuterons and antideuterons from massive backgrounds of protons
and antiprotons respectively, is essential in this context. Detailed Monte
Carlo simulations of AMS-02 have been used to evaluate the detector's
performance for mass separation at different energies. The obtained results and
physics prospects are presented.
[11]
oai:arXiv.org:0710.0993 [pdf] - 5676
Particle identification with the AMS-02 RICH detector: search for dark
matter with antideuterons
Submitted: 2007-10-04
The Alpha Magnetic Spectrometer (AMS), whose final version AMS-02 is to be
installed on the International Space Station (ISS) for at least 3 years, is a
detector designed to measure charged cosmic ray spectra with energies up to the
TeV region and with high energy photon detection capability up to a few hundred
GeV, using state-of-the art particle identification techniques. It is equipped
with several subsystems, one of which is a proximity focusing Ring Imaging
Cherenkov (RICH) detector equipped with a dual radiator (aerogel+NaF), a
lateral conical mirror and a detection plane made of 680 photomultipliers and
light guides, enabling precise measurements of particle electric charge and
velocity (Delta beta / beta ~ 10^-3 and 10^-4 for Z=1 and Z=10-20,
respectively) at kinetic energies of a few GeV/nucleon. Combining velocity
measurements with data on particle rigidity from the AMS-02 Tracker (Delta R /
R ~ 2% for R=1-10 GV) it is possible to obtain a reliable measurement for
particle mass. One of the main topics of the AMS-02 physics program is the
search for indirect signatures of dark matter. Experimental data indicate that
dark, non-baryonic matter of unknown composition is much more abundant than
baryonic matter, accounting for a large fraction of the energy content of the
Universe. Apart from antideuterons produced in cosmic-ray propagation, the
annihilation of dark matter will produce additional antideuteron fluxes.
Detailed Monte Carlo simulations of AMS-02 have been used to evaluate the
detector's performance for mass separation, a key issue for anti-D/anti-p
separation. Results of these studies are presented.
[12]
oai:arXiv.org:0710.0846 [pdf] - 1579258
Isotope separation with the RICH detector of the AMS Experiment
Submitted: 2007-10-03
The Alpha Magnetic Spectrometer (AMS), to be installed on the International
Space Station (ISS) in 2008, is a cosmic ray detector with several subsystems,
one of which is a proximity focusing Ring Imaging Cherenkov (RICH) detector.
This detector will be equipped with a dual radiator (aerogel+NaF), a lateral
conical mirror and a detection plane made of 680 photomultipliers and light
guides, enabling precise measurements of particle electric charge and velocity.
Combining velocity measurements with data on particle rigidity from the AMS
Tracker it is possible to obtain a measurement for particle mass, allowing the
separation of isotopes. A Monte Carlo simulation of the RICH detector, based on
realistic properties measured at ion beam tests, was performed to evaluate
isotope separation capabilities. Results for three elements -- H (Z=1), He
(Z=2) and Be (Z=4) -- are presented.