Normalized to: Bao, C.
[1]
oai:arXiv.org:1803.01018 [pdf] - 1783724
The EBEX Balloon Borne Experiment - Detectors and Readout
The EBEX Collaboration;
Abitbol, Maximilian;
Aboobaker, Asad M.;
Ade, Peter;
Araujo, Derek;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Feeney, Stephen M.;
Geach, Christopher;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hilton, Gene;
Hubmayr, Johannes;
Irwin, Kent;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Miller, Amber D.;
Milligan, Michael;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Reintsema, Carl;
Sagiv, Ilan;
Smecher, Graeme;
Tucker, Gregory S.;
Westbrook, Benjamin;
Young, Karl;
Zilic, Kyle
Submitted: 2018-03-02, last modified: 2018-07-30
EBEX was a long-duration balloon-borne experiment to measure the polarization
of the cosmic microwave background. The experiment had three frequency bands
centered at 150, 250, and 410 GHz and was the first to use a kilo-pixel array
of transition edge sensor (TES) bolometers aboard a balloon platform; shortly
after reaching float we operated 504, 342, and 109 TESs at each of the bands,
respectively. We describe the design and characterization of the array and the
readout system. We give the distributions of measured thermal conductances,
normal resistances, and transition temperatures. With the exception of the
thermal conductance at 150 GHz. We measured median low-loop-gain time constants
$\tau_{0}=$ 88, 46, and 57 ms and compare them to predictions. Two measurements
of bolometer absorption efficiency show high ($\sim$0.9) efficiency at 150 GHz
and medium ($\sim$0.35, and $\sim$0.25) at the two higher bands, respectively.
We measure a median total optical load of 3.6, 5.3 and 5.0 pW absorbed at the
three bands, respectively. EBEX pioneered the use of the digital version of the
frequency domain multiplexing (FDM) system which multiplexed the bias and
readout of 16 bolometers onto two wires. We present accounting of the measured
noise equivalent power. The median per-detector noise equivalent temperatures
referred to a black body with a temperature of 2.725 K are 400, 920, and 14500
$\mu$K$\sqrt{s}$ for the three bands, respectively. We compare these values to
our pre-flight predictions and to a previous balloon payload, discuss the
sources of excess noise, and the path for a future payload to make full use of
the balloon environment.
[2]
oai:arXiv.org:1711.01314 [pdf] - 1877825
Intensity-Coupled-Polarization in Instruments with a Continuously
Rotating Half-Wave Plate
Didier, Joy;
Miller, Amber D.;
Araujo, Derek;
Aubin, François;
Geach, Christopher;
Johnson, Bradley;
Korotkov, Andrei;
Raach, Kate;
Westbrook, Benjamin;
Young, Karl;
Aboobaker, Asad M.;
Ade, Peter;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Dobbs, Matt;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Jones, Terry;
Klein, Jeff;
Lee, Adrian;
Limon, Michele;
MacDermid, Kevin;
Milligan, Michael;
Pascale, Enzo;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Tucker, Carole;
Tucker, Gregory S.;
Zilic, Kyle
Submitted: 2017-11-03, last modified: 2018-02-28
We discuss a systematic effect associated with measuring polarization with a
continuously rotating half-wave plate. The effect was identified with the data
from the E and B Experiment (EBEX), which was a balloon-borne instrument
designed to measure the polarization of the CMB as well as that from Galactic
dust. The data show polarization fraction larger than 10\% while less than 3\%
were expected from instrumental polarization. We give evidence that the excess
polarization is due to detector non-linearity in the presence of a continuously
rotating HWP. The non-linearity couples intensity signals into polarization. We
develop a map-based method to remove the excess polarization. Applying this
method for the 150 (250) GHz bands data we find that 81\% (92\%) of the excess
polarization was removed. Characterization and mitigation of this effect is
important for future experiments aiming to measure the CMB B-modes with a
continuously rotating HWP.
[3]
oai:arXiv.org:1703.03847 [pdf] - 1783689
The EBEX Balloon Borne Experiment - Optics, Receiver, and Polarimetry
The EBEX Collaboration;
Aboobaker, Asad M.;
Ade, Peter;
Araujo, Derek;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Geach, Christopher;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Matsumura, Tomotake;
Miller, Amber D.;
Milligan, Michael;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Savini, Giorgio;
Spencer, Locke;
Tucker, Carole;
Tucker, Gregory S.;
Westbrook, Ben;
Young, Karl;
Zilic, Kyle
Submitted: 2017-03-10, last modified: 2017-05-30
The E and B Experiment (EBEX) was a long-duration balloon-borne cosmic
microwave background polarimeter that flew over Antarctica in 2013. We describe
the experiment's optical system, receiver, and polarimetric approach, and
report on their in-flight performance. EBEX had three frequency bands centered
on 150, 250, and 410 GHz. To make efficient use of limited mass and space we
designed a 115 cm$^{2}$sr high throughput optical system that had two ambient
temperature mirrors and four anti-reflection coated polyethylene lenses per
focal plane. All frequency bands shared the same optical train. Polarimetry was
achieved with a continuously rotating achromatic half-wave plate (AHWP) that
was levitated with a superconducting magnetic bearing (SMB). Rotation stability
was 0.45 % over a period of 10 hours, and angular position accuracy was 0.01
degrees. This is the first use of a SMB in astrophysics. The measured
modulation efficiency was above 90 % for all bands. To our knowledge the 109 %
fractional bandwidth of the AHWP was the broadest implemented to date. The
receiver that contained one lens and the AHWP at a temperature of 4 K, the
polarizing grid and other lenses at 1 K, and the two focal planes at 0.25 K
performed according to specifications giving focal plane temperature stability
with fluctuation power spectrum that had $1/f$ knee at 2 mHz. EBEX was the
first balloon-borne instrument to implement technologies characteristic of
modern CMB polarimeters including high throughput optical systems, and large
arrays of transition edge sensor bolometric detectors with mutiplexed readouts.
[4]
oai:arXiv.org:1702.07020 [pdf] - 1783687
The EBEX Balloon-Borne Experiment - Gondola, Attitude Control, and
Control Software
The EBEX Collaboration;
Aboobaker, Asad;
Ade, Peter;
Araujo, Derek;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Miller, Amber D.;
Milligan, Michael;
Moncelsi, Lorenzo;
Pascale, Enzo;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Tucker, Carole;
Tucker, Gregory S.;
Westbrook, Benjamin;
Young, Karl;
Zilic, Kyle
Submitted: 2017-02-22, last modified: 2017-04-11
The E and B Experiment (EBEX) was a long-duration balloon-borne instrument
designed to measure the polarization of the cosmic microwave background (CMB)
radiation. EBEX was the first balloon-borne instrument to implement a
kilo-pixel array of transition edge sensor (TES) bolometric detectors and the
first CMB experiment to use the digital version of the frequency domain
multiplexing system for readout of the TES array. The scan strategy relied on
40 s peak-to-peak constant velocity azimuthal scans. We discuss the unique
demands on the design and operation of the payload that resulted from these new
technologies and the scan strategy. We describe the solutions implemented
including the development of a power system designed to provide a total of at
least 2.3 kW, a cooling system to dissipate 590 W consumed by the detectors'
readout system, software to manage and handle the data of the kilo-pixel array,
and specialized attitude reconstruction software. We present flight performance
data showing faultless management of the TES array, adequate powering and
cooling of the readout electronics, and constraint of attitude reconstruction
errors such that the spurious B-modes they induced were less than 10% of CMB
B-mode power spectrum with $r=0.05$.
[5]
oai:arXiv.org:1601.07923 [pdf] - 1350058
Temperature calibration of the E and B experiment
Aubin, Francois;
Aboobaker, Asad M.;
Ade, Peter;
Araujo, Derek;
Baccigalupi, Carlo;
Bao, Chaoyun;
Borrill, Julian;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Feeney, Stephen;
Geach, Christopher;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hilton, Gene;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Kisner, Theodore;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
Macdermid, Kevin;
Marchenko, Valerie;
Miller, Amber D.;
Milligan, Michael;
Pascale, Enzo;
Puglisi, Giuseppe;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Reintsema, Carl;
Sagiv, Ilan;
Smecher, Graeme;
Stompor, Radek;
Tristram, Matthieu;
Tucker, Gregory S.;
Westbrook, Ben;
Young, Karl;
Zilic, Kyle
Submitted: 2016-01-28
The E and B Experiment (EBEX) is a balloon-borne polarimeter designed to
measure the polarization of the cosmic microwave background radiation and to
characterize the polarization of galactic dust. EBEX was launched December 29,
2012 and circumnavigated Antarctica observing $\sim$6,000 square degrees of sky
during 11 days at three frequency bands centered around 150, 250 and 410 GHz.
EBEX was the first experiment to operate a kilo-pixel array of transition-edge
sensor bolometers and a continuously rotating achromatic half-wave plate aboard
a balloon platform. It also pioneered the use of detector readout based on
digital frequency domain multiplexing.
We describe the temperature calibration of the experiment. The gain response
of the experiment is calibrated using a two-step iterative process. We use
signals measured on passes across the Galactic plane to convert from
readout-system counts to power. The effective smoothing scale of the EBEX
optics and the star camera-to-detector offset angles are determined through
\c{hi}2 minimization using the compact HII region RCW 38. This two-step process
is initially performed with parameters measured before the EBEX 2013 flight and
then repeated until the calibration factor and parameters converge.
[6]
oai:arXiv.org:1510.08796 [pdf] - 1344217
Maximum Likelihood Foreground Cleaning for Cosmic Microwave Background
Polarimeters in the Presence of Systematic Effects
Submitted: 2015-10-29, last modified: 2016-01-20
We extend a general maximum likelihood foreground estimation for cosmic
microwave background polarization data to include estimation of instrumental
systematic effects. We focus on two particular effects: frequency band
measurement uncertainty, and instrumentally induced frequency dependent
polarization rotation. We assess the bias induced on the estimation of the
$B$-mode polarization signal by these two systematic effects in the presence of
instrumental noise and uncertainties in the polarization and spectral index of
Galactic dust. Degeneracies between uncertainties in the band and polarization
angle calibration measurements and in the dust spectral index and polarization
increase the uncertainty in the extracted CMB $B$-mode power, and may give rise
to a biased estimate. We provide a quantitative assessment of the potential
bias and increased uncertainty in an example experimental configuration. For
example, we find that with 10\% polarized dust, tensor to scalar ratio of
$r=0.05$, and the instrumental configuration of the EBEX balloon payload, the
estimated CMB $B$-mode power spectrum is recovered without bias when the
frequency band measurement has 5% uncertainty or less, and the polarization
angle calibration has an uncertainty of up to 4$^{\circ}$.
[7]
oai:arXiv.org:1407.6894 [pdf] - 1215912
The performance of the bolometer array and readout system during the
2012/2013 flight of the E and B experiment (EBEX)
MacDermid, Kevin;
Aboobaker, Asad M.;
Ade, Peter;
Aubin, Francois;
Baccigalupi, Carlo;
Bandura, Kevin;
Bao, Chaoyun;
Borrill, Julian;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grain, Julien;
Grainger, Will;
Hanany, Shaul;
Helson, Kyle;
Hillbrand, Seth;
Hilton, Gene;
Hubmayr, Hannes;
Irwin, Kent;
Johnson, Bradley;
Jaffe, Andrew;
Jones, Terry;
Kisner, Ted;
Klein, Jeff;
Korotkov, Andrei;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
Miller, Amber;
Milligan, Michael;
Pascale, Enzo;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Reintsema, Carl;
Sagiv, Ilan;
Smecher, Graeme;
Stompor, Radek;
Tristram, Matthieu;
Tucker, Greg;
Westbrook, Ben;
Zilic, Kyle
Submitted: 2014-07-22
EBEX is a balloon-borne telescope designed to measure the polarization of the
cosmic microwave background radiation. During its eleven day science flight in
the Austral Summer of 2012, it operated 955 spider-web transition edge sensor
(TES) bolometers separated into bands at 150, 250 and 410 GHz. This is the
first time that an array of TES bolometers has been used on a balloon platform
to conduct science observations. Polarization sensitivity was provided by a
wire grid and continuously rotating half-wave plate. The balloon implementation
of the bolometer array and readout electronics presented unique development
requirements. Here we present an outline of the readout system, the remote
tuning of the bolometers and Superconducting QUantum Interference Device
(SQUID) amplifiers, and preliminary current noise of the bolometer array and
readout system.
[8]
oai:arXiv.org:1112.3057 [pdf] - 488565
The Impact of the Spectral Response of an Achromatic Half-Wave Plate on
the Measurement of the Cosmic Microwave Background Polarization
Bao, C.;
Gold, B.;
Baccigalupi, C.;
Didier, J.;
Hanany, S.;
Jaffe, A.;
Johnson, B. R.;
Leach, S.;
Matsumura, T.;
Miller, A.;
O'Dea, D.
Submitted: 2011-12-13
We study the impact of the spectral dependence of the linear polarization
rotation induced by an achromatic half-wave plate on measurements of cosmic
microwave background polarization in the presence of astrophysical foregrounds.
We focus on the systematic effects induced on the measurement of inflationary
gravitational waves by uncertainties in the polarization and spectral index of
Galactic dust. We find that for the experimental configuration and noise levels
of the balloon-borne EBEX experiment, which has three frequency bands centered
at 150, 250, and 410 GHz, a crude dust subtraction process mitigates systematic
effects to below detectable levels for 10% polarized dust and tensor to scalar
ratio of as low as r = 0.01. We also study the impact of uncertainties in the
spectral response of the instrument. With a top-hat model of the spectral
response for each band, characterized by band-center and band-width, and with
the same crude dust subtraction process, we find that these parameters need to
be determined to within 1 and 0.8 GHz at 150 GHz; 9 and 2.0 GHz at 250 GHz; and
20 and 14 GHz at 410 GHz, respectively. The approach presented in this paper is
applicable to other optical elements that exhibit polarization rotation as a
function of frequency.
[9]
oai:arXiv.org:1007.3672 [pdf] - 1033814
EBEX: A balloon-borne CMB polarization experiment
Reichborn-Kjennerud, Britt;
Aboobaker, Asad M.;
Ade, Peter;
Aubin, Françcois;
Baccigalupi, Carlo;
Bao, Chaoyun;
Borrill, Julian;
Cantalupo, Christopher;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grain, Julien;
Grainger, William;
Hanany, Shaul;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Jones, Terry;
Kisner, Theodore;
Klein, Jeff;
Korotkov, Andrei;
Leach, Sam;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Matsumura, Tomotake;
Meng, Xiaofan;
Miller, Amber;
Milligan, Michael;
Pascale, Enzo;
Polsgrove, Daniel;
Ponthieu, Nicolas;
Raach, Kate;
Sagiv, Ilan;
Smecher, Graeme;
Stivoli, Federico;
Stompor, Radek;
Tran, Huan;
Tristram, Matthieu;
Tucker, Gregory S.;
Vinokurov, Yury;
Yadav, Amit;
Zaldarriaga, Matias;
Zilic, Kyle
Submitted: 2010-07-21
EBEX is a NASA-funded balloon-borne experiment designed to measure the
polarization of the cosmic microwave background (CMB). Observations will be
made using 1432 transition edge sensor (TES) bolometric detectors read out with
frequency multiplexed SQuIDs. EBEX will observe in three frequency bands
centered at 150, 250, and 410 GHz, with 768, 384, and 280 detectors in each
band, respectively. This broad frequency coverage is designed to provide
valuable information about polarized foreground signals from dust. The
polarized sky signals will be modulated with an achromatic half wave plate
(AHWP) rotating on a superconducting magnetic bearing (SMB) and analyzed with a
fixed wire grid polarizer. EBEX will observe a patch covering ~1% of the sky
with 8' resolution, allowing for observation of the angular power spectrum from
\ell = 20 to 1000. This will allow EBEX to search for both the primordial
B-mode signal predicted by inflation and the anticipated lensing B-mode signal.
Calculations to predict EBEX constraints on r using expected noise levels show
that, for a likelihood centered around zero and with negligible foregrounds,
99% of the area falls below r = 0.035. This value increases by a factor of 1.6
after a process of foreground subtraction. This estimate does not include
systematic uncertainties. An engineering flight was launched in June, 2009,
from Ft. Sumner, NM, and the long duration science flight in Antarctica is
planned for 2011. These proceedings describe the EBEX instrument and the North
American engineering flight.
[10]
oai:arXiv.org:1006.5256 [pdf] - 229058
Software systems for operation, control, and monitoring of the EBEX
instrument
Milligan, Michael;
Ade, Peter;
Aubin, François;
Baccigalupi, Carlo;
Bao, Chaoyun;
Borrill, Julian;
Cantalupo, Christopher;
Chapman, Daniel;
Didier, Joy;
Dobbs, Matt;
Grainger, Will;
Hanany, Shaul;
Hillbrand, Seth;
Hubmayr, Johannes;
Jaffe, Andrew;
Johnson, Bradley;
Kisner, Theodore;
Klein, Jeff;
Korotkov, Andrei;
Leach, Sam;
Lee, Adrian;
Levinson, Lorne;
Limon, Michele;
MacDermid, Kevin;
Matsumura, Tomotake;
Miller, Amber;
Pascale, Enzo;
Polsgrove, Daniel;
Ponthieu, Nicolas;
Raach, Kate;
Reichborn-Kjennerud, Britt;
Sagiv, Ilan;
Tran, Huan;
Tucker, Gregory S.;
Vinokurov, Yury;
Yadav, Amit;
Zaldarriaga, Matias;
Zilic, Kyle
Submitted: 2010-06-27, last modified: 2010-07-05
We present the hardware and software systems implementing autonomous
operation, distributed real-time monitoring, and control for the EBEX
instrument. EBEX is a NASA-funded balloon-borne microwave polarimeter designed
for a 14 day Antarctic flight that circumnavigates the pole. To meet its
science goals the EBEX instrument autonomously executes several tasks in
parallel: it collects attitude data and maintains pointing control in order to
adhere to an observing schedule; tunes and operates up to 1920 TES bolometers
and 120 SQUID amplifiers controlled by as many as 30 embedded computers;
coordinates and dispatches jobs across an onboard computer network to manage
this detector readout system; logs over 3~GiB/hour of science and housekeeping
data to an onboard disk storage array; responds to a variety of commands and
exogenous events; and downlinks multiple heterogeneous data streams
representing a selected subset of the total logged data. Most of the systems
implementing these functions have been tested during a recent engineering
flight of the payload, and have proven to meet the target requirements. The
EBEX ground segment couples uplink and downlink hardware to a client-server
software stack, enabling real-time monitoring and command responsibility to be
distributed across the public internet or other standard computer networks.
Using the emerging dirfile standard as a uniform intermediate data format, a
variety of front end programs provide access to different components and views
of the downlinked data products. This distributed architecture was demonstrated
operating across multiple widely dispersed sites prior to and during the EBEX
engineering flight.
[11]
oai:arXiv.org:1005.3339 [pdf] - 168465
The EBEX Cryostat and Supporting Electronics
Sagiv, Ilan;
Aboobaker, Asad M.;
Bao, Chaoyun;
Hanany, Shaul;
Jones, Terry;
Klein, Jeffrey;
Milligan, Michael;
Polsgrove, Daniel E.;
Raach, Kate;
Zilic, Kyle;
Korotkov, Andrei;
Tucker, Gregory S.;
Vinukurov, Yuri;
Matsumura, Tomotake;
Ade, Peter;
Grainger, Will;
Pascale, Enzo;
Chapman, Daniel;
Didier, Joy;
Hillbrand, Seth;
Reichborn-Kjennerud, Britt;
Limon, Michele;
Miller, Amber;
Jaffe, Andrew;
Yadav, Amit;
Zaldarriaga, Matias;
Ponthieu, Nicolas;
Tristram, Matthieu;
Borrill, Julian;
Cantalupo, Christopher;
Kisner, Ted;
Aubin, Francois;
Dobbs, Matt;
MacDermid, Kevin;
Hilton, Gene;
Hubmayr, Johhannes;
Irwin, Kent;
Reintsema, Carl;
Baccigalupi, Carlo;
Leach, Sam;
Johnson, Bradley;
Lee, Adrian;
Tran, Huan;
Levinson, Lorne
Submitted: 2010-05-18
We describe the cryostat and supporting electronics for the EBEX experiment.
EBEX is a balloon-borne polarimeter designed to measure the B-mode polarization
of the cosmic microwave background radiation. The instrument includes a 1.5
meter Gregorian-type telescope and 1432 bolometric transition edge sensor
detectors operating at 0.3 K. Electronics for monitoring temperatures and
controlling cryostat refrigerators is read out over CANbus. A timing system
ensures the data from all subsystems is accurately synchronized. EBEX completed
an engineering test flight in June 2009 during which the cryogenics and
supporting electronics performed according to predictions. The temperatures of
the cryostat were stable, and an analysis of a subset of the data finds no scan
synchronous signal in the cryostat temperatures. Preparations are underway for
an Antarctic flight.