Normalized to: Banyal, R.
[1]
oai:arXiv.org:2006.01453 [pdf] - 2105844
Developement of a stabilized Fabry-Perot etalon based calibrator for
Hanle Echelle Spectrograph (HESP)
Submitted: 2020-06-02
Accurate wavelength calibration is an important factor for any measurement
with high resolution spectrographs. Stellar spectrum comprises of discrete
absorption or emission lines whose position is precisely determined by
calibrating the spectrograph using known reference lines generated from
laboratory sources. For the spectrograph to measure small variations in Doppler
shift, the wavelength calibration must be sufficiently stable during
observation time. Instrument instability, mainly due to environmental factors
like temperature and pressure variations, limitations of traditional
calibration methods, for example Th-Ar lamps, are the main challenges which
high precision spectroscopy. Through proper environmental control, by
maintaining pressure at few mbar and temperature fluctuations within
$\pm$0.05$^{\circ}$C, Fabry P\'erot etalon (FP) can yield a velocity precision
of 1-10 m/s, when used for wavelength calibration. We have developed a
passively stabilized FP based wavelength calibrator for Hanle Echelle
Spectrograph (HESP) installed on Himalayan Chandra Telescope (HCT) at Indian
Astronomical Observatory (IAO), Hanle, India. The etalon has been characterized
using Fourier Transform Spectrograph (FTS) and initial test runs have been
performed with HESP. In this paper we present the design and construction of
the instrument along with preliminary test results obtained from HESP.
[2]
oai:arXiv.org:1908.11027 [pdf] - 1951540
Development of image motion compensation system for 1.3 m telescope at
Vainu Bappu Observatory
Submitted: 2019-08-28
We developed a tip-tilt system to compensate the turbulence induced image
motion for 1.3 m telescope at Vainu Bappu Observatory, Kavalur. The instrument
is designed to operate at visible wavelength band (480-700 nm) with a field of
view $1^{\prime}\times1^{\prime}$. The tilt corrected images have shown up to
$\approx$ 57% improvement in image resolution and a corresponding peak
intensity increase by a factor of $\approx$ 2.8. A closed-loop correction
bandwidth of $\approx$ 26 Hz has been achieved with on-sky tests and the root
mean square motion of the star image has been reduced by a factor of $\sim$ 14.
These results are consistent with theoretical and numerical predictions of
wave-front aberrations caused by atmospheric turbulence and image quality
improvement expected from a real-time control system. In this paper, we present
the details of the instrument design, laboratory calibration studies and
quantify its performance on the telescope.
[3]
oai:arXiv.org:1908.03623 [pdf] - 1935816
High-resolution Infrared Spectrograph for Exoplanet Characterization
with the Keck and Thirty Meter Telescopes
Mawet, Dimitri;
Fitzgerald, Michael;
Konopacky, Quinn;
Beichman, Charles;
Jovanovic, Nemanja;
Dekany, Richard;
Hover, David;
Chisholm, Eric;
Ciardi, David;
Artigau, Etienne;
Banyal, Ravinder;
Beatty, Thomas;
Benneke, Bjorn;
Blake, Geoffrey A.;
Burgasser, Adam;
Canalizo, Gabriela;
Chen, Guo;
Do, Tuan;
Doppmann, Greg;
Doyon, Rene;
Dressing, Courtney;
Fang, Min;
Greene, Thomas;
Hillenbrand, Lynne;
Howard, Andrew;
Kane, Stephen;
Kataria, Tiffany;
Kempton, Eliza;
Knutson, Heather;
Kotani, Takayuki;
Lafreniere, David;
Liu, Chao;
Nishiyama, Shogo;
Pandey, Gajendra;
Plavchan, Peter;
Prato, Lisa;
Rajaguru, S. P.;
Robertson, Paul;
Salyk, Colette;
Sato, Bunei;
Schlawin, Everett;
Sengupta, Sujan;
Sivarani, Thirupathi;
Skidmore, Warren;
Tamura, Motohide;
Terada, Hiroshi;
Vasisht, Gautam;
Wang, Ji;
Zhang, Hui
Submitted: 2019-08-09
HISPEC (High-resolution Infrared Spectrograph for Exoplanet Characterization)
is a proposed diffraction-limited spectrograph for the W.M. Keck Observatory,
and a pathfinder for the MODHIS facility project (Multi-Object
Diffraction-limited High-resolution Infrared Spectrograph) on the Thirty Meter
Telescope. HISPEC/MODHIS builds on diffraction-limited spectrograph designs
which rely on adaptively corrected single-mode fiber feeds. Seeing-limited
high-resolution spectrographs, by virtue of the conservation of beam etendue,
grow in volume following a D^3 power law (D is the telescope diameter), and are
subject to daunting challenges associated with their large size.
Diffraction-limited spectrographs fed by single mode fibers are decoupled from
the telescope input, and are orders of magnitude more compact and have
intrinsically stable line spread functions. Their efficiency is directly
proportional to the performance of the adaptive optics (AO) system. AO
technologies have matured rapidly over the past two decades and are baselined
for future extremely large telescopes. HISPEC/MODHIS will take R>100,000
spectra of a few objects in a 10" field-of-view sampled at the diffraction
limit (~10-50 mas), simultaneously from 0.95 to 2.4 microns (y-K). The
scientific scope ranges from exoplanet infrared precision radial velocities,
spectroscopy of transiting, close-in, and directly imaged exoplanets
(atmospheric composition and dynamics, RM effect, spin measurements, Doppler
imaging), brown dwarf characterization, stellar physics/chemistry,
proto-planetary disk kinematics/composition, Solar system, extragalactic
science, and cosmology. HISPEC/MODHIS features a compact, cost-effective design
optimized to fully exploit the existing Keck-AO and future TMT-NFIRAOS
infrastructures and boost the scientific reach of Keck Observatory and TMT soon
after first light.
[4]
oai:arXiv.org:1906.05064 [pdf] - 1899454
Estimation and correction of the instrumental perturbations of Vainu
Bappu Telescope Echelle spectrograph using a model-based approach
Submitted: 2019-06-12
The Echelle spectrograph operating at Vainu Bappu Telescope (VBT), India, is
a general purpose instrument used for many high-resolution spectroscopic
observations. A concerted effort is being made to expand the scientific
capability of the instrument in emerging areas of observational astronomy. The
present study is aimed at evaluating the feasibility of the spectrograph to
carry out precision Radial Velocity (RV) measurements. In the current design,
major factors limiting the RV precision of the spectrograph arise from the
movable grating and slit; optical aberrations; positional uncertainty
associated with optomechanical mounts and environmental and thermal
instabilities in the spectrograph room. RV instabilities due to temperature and
pressure variations in the environment are estimated to vary around 120 $
\textrm{ms}^{-1} $ and 400 $ \textrm{ms}^{-1} $ respectively. The positional
uncertainty of the grating in the spectrograph could induce a spectral shift
$\sim1.4\,\textrm{kms}^{-1} $ across the Echelle orders. A Zemax model is used
to overcome the uncertainty in the zero-positioning and lack of repeatability
of the moving components. We propose to obtain the ThAr lamp observations and
using the Zemax model as the reference, predict the drifts in the positions of
the optical components. The perturbations of the optical components from the
nominal position are corrected at the beginning of the observational run. After
a good match is obtained between the model and the observations, we propose to
use a Zemax model to improve the wavelength calibration solution. We could
match the observations and model within $\pm$~1 pixels accuracy after the model
parameters were perturbed in a real-time setup of the spectrograph. In this
paper, we present the estimation of the perturbations of optical components and
the effect on the RV obtained.
[5]
oai:arXiv.org:1905.10539 [pdf] - 1889669
Toward precision radial velocity measurements using Echelle spectrograph
at Vainu Bappu Telescope
Submitted: 2019-05-25
The Echelle spectrograph operating at Vainu Bappu Telescope (VBT) is a
general purpose instrument designed for high resolution spectroscopy. It is
being considered for precision Doppler measurements without altering the
existing design and basic usage. However, the design level limitations and
environmental perturbations are a major source of instability and systematic
errors. As a result, a small Doppler signal in the stellar spectra is
completely swamped by the large and uncontrolled instrumental drift. In this
paper, we discuss some of the remedial measures we took to improve the radial
velocity performance of the spectrograph. We show that a new auto-guider
assembly has greatly reduced the mechanical jitter of the star image at the
fibre input, making the illumination of the spectrograph slit at the other end
stable. We have also installed an iodine absorption cell to track and eliminate
the instrumental drifts to facilitate precision radial velocity observations.
Furthermore, we have developed a generic algorithm that uses iodine exposures
to extract the stellar radial velocities without the need for the complex
forward modeling. Our algorithm is not accurate to the level of traditional
iodine technique. However it is convenient to use on a low-cost general-purpose
spectrograph targeting a moderate Radial Velocity (RV) precision at a few
10-100~$\textrm{ms}^{-1}$ level. Finally, we have demonstrated the usefulness
of our approach by measuring the RV signal of a well known short-period,
planet-hosting star.
[6]
oai:arXiv.org:1901.02187 [pdf] - 1811335
Measurements of atmospheric turbulence parameters at Vainu Bappu
Observatory using short-exposure CCD images
Submitted: 2019-01-08
We report the atmospheric turbulence parameters namely, atmospheric seeing,
the tilt-anisoplanatic angle ($\theta_0$) and the coherence time ($\tau_0$),
measured under various sky conditions, at Vainu Bappu Observatory in Kavalur.
Bursts of short exposure images of selected stars were recorded with a
high-speed, frame-transfer CCD mounted on the Cassegrain focus of a newly
commissioned 1.3 m telescope. The estimated median seeing is $ \approx
1.85^{\prime\prime} $ at wavelength of $\sim 600$ nm, the image motion
correlation between different pairs of stars is $\sim 44\%$ for $\theta_0
\approx 36^{\prime\prime}$ and mean $\tau_0$ is $\approx 2.4$ ms. This work was
motivated by the design considerations and expected the performance of an
adaptive optics system that is currently being planned for the telescope.
[7]
oai:arXiv.org:1809.08385 [pdf] - 1775703
Properties and occurrence rates of $Kepler$ exoplanet candidates as a
function of host star metallicity from the DR25 catalog
Submitted: 2018-09-22
Correlations between the occurrence rate of exoplanets and their host star
properties provide important clues about the planet formation processes. We
studied the dependence of the observed properties of exoplanets (radius, mass,
and orbital period) as a function of their host star metallicity. We analyzed
the planetary radii and orbital periods of over 2800 $Kepler$ candidates from
the latest $Kepler$ data release DR25 (Q1-Q17) with revised planetary radii
based on $Gaia$~DR2 as a function of host star metallicity (from the Q1-Q17
(DR25) stellar and planet catalog). With a much larger sample and improved
radius measurements, we are able to reconfirm previous results in the
literature. We show that the average metallicity of the host star increases as
the radius of the planet increases. We demonstrate this by first calculating
the average host star metallicity for different radius bins and then
supplementing these results by calculating the occurrence rate as a function of
planetary radius and host star metallicity. We find a similar trend between
host star metallicity and planet mass: the average host star metallicity
increases with increasing planet mass. This trend, however, reverses for masses
$> 4.0\, M_\mathrm{J}$: host star metallicity drops with increasing planetary
mass. We further examined the correlation between the host star metallicity and
the orbital period of the planet. We find that for planets with orbital periods
less than 10 days, the average metallicity of the host star is higher than that
for planets with periods greater than 10 days.
[8]
oai:arXiv.org:1808.07643 [pdf] - 1738003
Installation of Solar Chromospheric Telescope at the Indian Astronomical
Observatory, Merak
Submitted: 2018-08-23
We report the observations of the solar chromosphere from a newly
commissioned solar telescope at the incursion site near Pangong Tso lake in
Merak (Leh/Ladakh). This new H$_{\alpha}$ telescope at the Merak site is
identical to the Kodaikanal H$_{\alpha}$ telescope. The telescope is installed
in the month of August, 2017 at the Merak site. A 20-cm doublet lens with
additional re-imaging optics makes the telescope. A Lyot filter with
0.5~\AA~passband isolates the Balmer line of the hydrogen spectra to make the
observations of the solar chromosphere. The observations made in H$_{\alpha}$
wavelength delineates the magnetic field directions at the sunspot and the
quiet regions. A CCD detector records the images of the chromosphere with a
pixel resolution of 0.27$^{\prime\prime}$ and covers 9.2$^{\prime}$
field-of-view. This telescope has a good guiding system that keeps the FOV in
the intended position. We report the development of control software for tuning
the filter unit, control detector system, observations, and calibration of the
data to make it useful for the scientific community. Some preliminary results
obtained from the Merak H$_{\alpha}$ telescope are also presented. This high
altitude facility is a timely addition to regularly available H$_{\alpha}$
images around the globe.
[9]
oai:arXiv.org:1802.00372 [pdf] - 1628305
Development of a Lunar Scintillometer as part of the National Large
Optical Telescope Site Survey
Submitted: 2018-02-01
Ground layer turbulence is a very important site characterization parameter
used to assess the quality of an astronomical site. The Lunar Scintillometer is
a simple and effective site-testing device for measuring the ground layer
turbulence. It consists of a linear array of photodiodes which are sensitive to
the slight variations in the moon's brightness due to scintillation by the
lower layers of the Earth's atmosphere. The covariance of intensity values
between the non-redundant photodiode baselines can be used to measure the
turbulence profile from the ground up to a height determined by the furthest
pair of detectors. The six channel lunar scintillometer that has been developed
at the Indian Institute of Astrophysics is based closely on an instrument built
by the team led by Andrei Tokovinin of Cerro Tololo Inter-American Observatory
(CTIO), Chile. We have fabricated the instrument based on the existing
electronic design, and have worked on the noise analysis, an EMI
(Electromagnetic Induction) resistant PCB design and the software pipeline for
analyzing the data from the same. The results from the instrument's multi-year
campaign at Mount Saraswati, Hanle is also presented.
[10]
oai:arXiv.org:1706.09202 [pdf] - 1585246
Stability analysis of VBT Echelle spectrograph for precise radial
velocity measurements
Submitted: 2017-06-28
A fiber-fed Echelle spectrograph at 2.3 m Vainu Bappu Telescope (VBT),
Kavalur, has been in operation since 2005. Owing to various technological
advancements in precision spectroscopy in recent years, several research
avenues have been opened in observational astronomy. These developments have
created a demand to improve the Doppler precision of our spectrograph.
Currently, the stability of the instrument is compromised by the temperature
and pressure fluctuations inside the Echelle room. Further, a better wavelength
calibration approach is needed to carefully track and disentangle the
instrumental effects from stellar spectra. While planning a possible upgrade
with an Iodine absorption gas cell, we measured the raw stability of the
spectrograph using a series of calibration frames taken with the ThAr gas
discharge lamp. The time series data were analysed with cross-correlation
method and the shift in ThAr emission lines was accurately measured across
different Echelle orders. In this paper, we present our stability analysis
methodology and results for the Kavalur spectrograph. We also identify possible
sources of error and discuss our strategy to mitigate them.
[11]
oai:arXiv.org:1706.07385 [pdf] - 1585045
Trigger of successive filament eruptions observed by SDO and STEREO
Submitted: 2017-06-22
Using multi-wavelength observation from SDO and STEREO, we investigated the
mechanism of two successive eruptions (F1 & F2) of a filament in active region
NOAA 11444 on 27 march, 2012. The filament was inverse `J' shaped and lying
along a quasi-circular polarity inversion line (PIL). The first part of the
filament (F1) erupted at ~2:30UT on 27 March 2012, the second part of the
filament (F2) erupted at around 4:20 UT on the same day. A precursor/pre-flare
brightening was observed below filament's main axis about 30 min prior to F1.
The brightening was followed by a jet-like ejection below filament, which
triggered the eruption. Before the eruption of F2, the filament seems to be
trapped within the overlying arcade loops almost for $\sim$1.5~hr before its
successful eruption. Interestingly, we observed simultaneously contraction
(~12km/s) and expansion (~20km/s) of arcade loops in the active region before
F2. HMI magnetograms show the converging motion of the opposite polarities
resulting in flux cancellation near PIL. We suggest that flux cancellation at
PIL resulted jet-like ejection below filament's main axis, which triggered the
eruption F1 similar to tether-cutting process. The eruption F2 was triggered by
removal of the overlying arcade loops via reconnection process. Both filament
eruptions produced high speed (~1000km/s) CMEs.
[12]
oai:arXiv.org:1612.07431 [pdf] - 1533767
A dual cavity Fabry-Perot device for high precision Doppler measurements
in astronomy
Submitted: 2016-12-21, last modified: 2017-01-24
We propose a dual cavity Fabry-Perot interferometer as a wavelength
calibrator and a stability tracking device for astronomical spectrograph. The
FPI consists of two adjoining cavities engraved on a low expansion monoblock
spacer. A low-finesse astro-cavity is intended for generating a uniform grid of
reference lines to calibrate the spectrograph and a high-finesse lock-cavity is
meant for tracking the stability of the reference lines using optical frequency
standards. The differential length changes in two cavities due to temperature
and vibration perturbations are quantitatively analyzed using finite element
method. An optimized mounting geometry with fractional length changes $\Delta
L/L \approx 1.5\times 10^{-12}$ is suggested. We also identify conditions
necessary to suppress relative length variations between two cavities well
below 10$^{-10}$~m, thus facilitating accurate dimension tracking and
generation of stable reference spectra for Doppler measurement at 10 cms$^{-1}$
level.
[13]
oai:arXiv.org:1512.06512 [pdf] - 1343020
Fabry-P\'erot based Narrow Band Imager for Solar Filament Observations
Submitted: 2015-12-21
We have recently developed a narrow band imager (NBI) using an air gap based
Fabry-P\'erot (FP) interferometer at the Indian Institute of Astrophysics,
Bangalore. Narrow band imaging is achieved by using an FP interferometer
working in combination with an order sorting pre-filter. The NBI can be tuned
to a different wavelength position on the line profile by changing the plate
separation of the FP. The interferometer has a 50 mm clear aperture with a
bandpass of $\sim$247.8 m\AA and a free spectral range of $\sim$5.3\AA at
$\lambda$ = 656.3 nm. The developed NBI is used to observe the solar filament
in the H$\alpha$ wavelength. The instrument is being used to image the Sun at
chromospheric height and it is also able to scan the H$\alpha$ spectral line
profile at different wavelength positions. We have also made Doppler velocity
maps at chromospheric height by taking the blue and red wing images at $\pm$176
m\AA wavelength positions separately away from the line center of the spectral
line. In this paper, we present a description of the NBI including lab test
results of individual components and some initial observations carried out with
this instrument.
[14]
oai:arXiv.org:1410.3592 [pdf] - 882027
Observations of Photospheric Vortical Motions During the Early Stage of
Filament Eruption
Submitted: 2014-10-14
Solar filaments/prominences exhibit rotational motion during different phases
of their evolution from their formation to eruption. We have observed the
rotational/vortical motion in the photosphere near the ends of ten filaments
during their initial phase of eruption, at the onset of the fast rise phase.
All the filaments were associated with active regions. The photospheric
vortical motions we observed lasted for 4--20 minutes. In the vicinity of the
conjugate ends of the filament the direction of rotation was opposite, except
for two cases, where rotational motion was observed at only one end point. The
sudden onset of a large photospheric vortex motion could have played a role in
destabilizing the filament by transporting axial flux into the activated
filament thereby increasing the outward magnetic pressure in it. The outward
magnetic pressure may have pushed the filament/flux rope to the height where
the torus instability criterion was satisfied, and hence it could have caused
the filament instability and eruption.
[15]
oai:arXiv.org:1408.6111 [pdf] - 1216521
A laser-lock concept to reach cm/s-precision in Doppler experiments with
Fabry-Perot wavelength calibrators
Submitted: 2014-08-26
State-of-the-art Doppler experiments require wavelength calibration with
precision at the cm/s level. A low-finesse Fabry-Perot interferometer (FPI) can
provide a wavelength comb with a very large bandwidth as required for
astronomical experiments, but unavoidable spectral drifts are difficult to
control. Instead of actively controlling the FPI cavity, we propose to
passively stabilize the interferometer and track the time-dependent cavity
length drift externally. A dual-finesse cavity allows drift tracking during
observation. The drift of the cavity length is monitored in the high-finesse
range relative to an external standard: a single narrow transmission peak is
locked to an external cavity diode laser and compared to an atomic frequency.
Following standard locking schemes, tracking at sub-mm/s precision can be
achieved. This is several orders of magnitude better than currently planned
high-precision Doppler experiments. It allows freedom for relaxed designs
rendering this approach particularly interesting for upcoming Doppler
experiments. We also show that the large number of interference modes used in
an FPI allows us to unambiguously identify the interference mode of each FPI
transmission peak defining its absolute wavelength solution. The accuracy
reached in each resonance with the laser concept is then defined by the cavity
length that is determined from the one locked peak and by the group velocity
dispersion. The latter can vary by several 100m/s over the relevant frequency
range and severely limits the accuracy of individual peak locations. A
potential way to determine the absolute peak positions is to externally measure
the frequency of each individual peak with a laser frequency comb (LFC). Thus,
the concept of laser-locked FPIs may be useful for applying the absolute
accuracy of an LFC to astronomical spectrographs without the need for an LFC at
the observatory.
[16]
oai:arXiv.org:1307.7248 [pdf] - 699286
Filament eruption in association with rotational motion near the
filament footpoints
Submitted: 2013-07-27
The active region magnetic field surrounding the filament plays an important
role in filament formation, their evolution and disruption. We investigated a
filament eruption that occurred in southern hemisphere of the Sun on July 08,
2011 using AIA and HMI data. The filament was located in a region close to the
active region NOAA 11247 with its West-most footpoint anchored in the negative
polarity plage region and the East-most in the positive polarity plage region.
During observations, the magnetic flux was emerging in the active region and
also in the plage regions. The flux emergence was stopped in West-most
footpoint of the plage region about an hour before the filament eruption. A
converging motion was also observed for many hours in the Western footpoint of
the filament. The filament had left-handed twist and the net injected magnetic
helicity was positive in both footpoints. Both sign of magnetic helicity were
observed in the Western footpoint of the filament where the eruption has
initiated. Further, an anti-clockwise rotational motion was observed in both
the footpoints just after the onset of filament eruption which lasted for 6 min
during the eruption process. The emerging flux, converging motion and injection
of opposite magnetic helicity could be responsible for destabilizing of the
Western footpoint of the filament leading to eruption. The torque imbalance
between the expanded portion of the flux tube and the photosphere may have
caused the rotation in the footpoint region which changed the trend in the
injected magnetic helicity after the filament eruption.
[17]
oai:arXiv.org:1302.6600 [pdf] - 1164872
Opto-thermal analysis of a lightweighted mirror for solar telescope
Submitted: 2013-02-26
In this paper, an opto-thermal analysis of a moderately heated lightweighted
solar telescope mirror is carried out using 3D finite element analysis (FEA). A
physically realistic heat transfer model is developed to account for the
radiative heating and energy exchange of the mirror with surroundings. The
numerical simulations show the non-uniform temperature distribution and
associated thermo-elastic distortions of the mirror blank clearly mimicking the
underlying discrete geometry of the lightweighted substrate. The computed
mechanical deformation data is analyzed with surface polynomials and the
optical quality of the mirror is evaluated with the help of a ray-tracing
software. The thermal print-through distortions are further shown to contribute
to optical figure changes and mid-spatial frequency errors of the mirror
surface. A comparative study presented for three commonly used substrate
materials, namely, Zerodur, Pyrex and Silicon Carbide (SiC) is relevant to vast
area of large optics requirements in ground and space applications.
[18]
oai:arXiv.org:1102.0111 [pdf] - 1051804
Thermal characteristics of a classical solar telescope primary mirror
Submitted: 2011-02-01
We present a detailed thermal and structural analysis of a 2m class solar
telescope mirror which is subjected to a varying heat load at an observatory
site. A 3-dimensional heat transfer model of the mirror takes into account the
heating caused by a smooth and gradual increase of the solar flux during the
day-time observations and cooling resulting from the exponentially decaying
ambient temperature at night. The thermal and structural response of two
competing materials for optical telescopes, namely Silicon Carbide -best known
for excellent heat conductivity and Zerodur -preferred for its extremely low
coefficient of thermal expansion, is investigated in detail. The insight gained
from these simulations will provide a valuable input for devising an efficient
and stable thermal control system for the primary mirror.
[19]
oai:arXiv.org:0911.0817 [pdf] - 30290
Phase characteristics of reflecting and transmitting type twisted
nematic spatial light modulators
Submitted: 2009-11-04
The phase characteristics of reflecting and transmitting type twisted nematic
liquid crystal based Spatial Light Modulators (SLMs) were measured using
interferometry. Device parameters like contrast, brightness, input and output
polarizer angles have been optimized and SLM phase nonlinearity was reduced by
higher order polynomial interpolation. Higher order aberration production
ability of SLMs was tested by measuring the shift in the spots of a Shack
Hartmann Sensor.
[20]
oai:arXiv.org:0909.3413 [pdf] - 28521
Spatial Light Modulator for wavefront correction
Submitted: 2009-09-18
We present a liquid crystal method of correcting the phase of an aberrated
wavefront using a spatial light modulator. A simple and efficient lab model has
been demonstrated for wavefront correction. The crux of a wavefront correcting
system in an adaptive optics system lies in the speed and the image quality
that can be achieved. The speeds and the accuracy of wavefront representation
using Zernike polynomials have been presented using a very fast method of
computation.