Normalized to: Bandler, S.
[1]
oai:arXiv.org:1908.09010 [pdf] - 2040682
Micro-X Sounding Rocket: Transitioning from First Flight to a Dark
Matter Configuration
Adams, J. S.;
Anderson, A. J.;
Baker, R.;
Bandler, S. R.;
Bastidon, N.;
Castro, D.;
Danowski, M. E.;
Doriese, W. B.;
Eckart, M. E.;
Figueroa-Feliciano, E.;
Goldfinger, D. C.;
Heine, S. N. T.;
Hilton, G. C.;
Hubbard, A. J. F.;
Kelley, R. L.;
Kilbourne, C. A.;
Manzagol-Harwood, R. E.;
McCammon, D.;
Okajima, T.;
Porter, F. S.;
Reintsema, C. D.;
Serlemitsos, P.;
Smith, S. J.;
Wikus, P.
Submitted: 2019-08-22, last modified: 2020-01-30
The Micro-X sounding rocket flew for the first time on July 22, 2018,
becoming the first program to fly Transition-Edge Sensors and multiplexing
SQUID readout electronics in space. While a rocket pointing failure led to no
time on-target, the success of the flight systems was demonstrated. The
successful flight operation of the instrument puts the program in a position to
modify the payload for indirect galactic dark matter searches. The payload
modifications are motivated by the science requirements of this observation.
Micro-X can achieve world-leading sensitivity in the keV regime with a single
flight. Dark matter sensitivity projections have been updated to include recent
observations and the expected sensitivity of Micro-X to these observed fluxes.
If a signal is seen (as seen in the X-ray satellites), Micro-X can
differentiate an atomic line from a dark matter signature.
[2]
oai:arXiv.org:1908.09689 [pdf] - 2022786
First Operation of TES Microcalorimeters in Space with the Micro-X
Sounding Rocket
Adams, J. S.;
Baker, R.;
Bandler, S. R.;
Bastidon, N.;
Danowski, M. E.;
Doriese, W. B.;
Eckart, M. E.;
Figueroa-Feliciano, E.;
Goldfinger, D. C.;
Heine, S. N. T.;
Hilton, G. C.;
Hubbard, A. J. F.;
Kelley, R. L.;
Kilbourne, C. A.;
Manzagol-Harwood, R. E.;
McCammon, D.;
Okajima, T.;
Porter, F. S.;
Reintsema, C. D.;
Serlemitsos, P.;
Smith, S. J.;
Ullom, J. N.;
Wikus, P.
Submitted: 2019-08-26, last modified: 2020-01-05
Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter
array to perform high-resolution X-ray spectroscopy. This instrument flew for
the first time on July 22nd, 2018 from the White Sands Missile Range, USA. This
flight marks the first successful operation of a Transition-Edge Sensor array
and its time division multiplexing read-out system in space. This launch was
dedicated to the observation of the supernova remnant Cassiopeia A. A failure
in the attitude control system prevented the rocket from pointing and led to no
time on target. The on-board calibration source provided X-rays in flight, and
it is used to compare detector performance during pre-flight integration,
flight, and after the successful post-flight recovery. This calibration data
demonstrates the capabilities of the detector in a space environment as well as
its potential for future flights.
[3]
oai:arXiv.org:1908.02687 [pdf] - 2050188
Towards 100,000-pixel microcalorimeter arrays using multi-absorber
transition-edge sensors
Smith, S. J.;
Adams, J. S.;
Bandler, S. R.;
Beaumont, S.;
Chervenak, J. A.;
Datesman, A. M.;
Finkbeiner, F. M.;
Hummatov, R.;
Kelly, R. L.;
Kilbourne, C. A.;
Miniussi, A. R.;
Porter, F. S.;
Sadleir, J. E.;
Sakai, K.;
Wakeham, N. A.;
Wassell, E. J.;
Witthoeft, M. C.;
Ryu, K.
Submitted: 2019-08-07
We report on the development of multi-absorber transition edge sensors
(TESs), referred to as hydras. A hydra consists of multiple x-ray absorbers
each with a different thermal conductance to a TES. Position information is
encoded in the pulse shape. With some trade-off in performance, hydras enable
very large format arrays without the prohibitive increase in bias and read-out
components associated with arrays of individual TESs. Hydras are under
development for the next generation of space telescope such as Lynx. Lynx is a
NASA concept under study that will combine a < 1 arcsecond angular resolution
optic with 100,000-pixel microcalorimeter array with energy resolution of
deltaE_FWHM ~ 3 eV in the soft x-ray energy range. We present first results
from hydras with 25-pixels for Lynx. Designs with absorbers on a 25 micron and
50 micron pitch are studied. Arrays incorporate, for the first time, microstrip
buried wiring layers of suitable pitch and density required to readout a
full-scale Lynx array. The resolution from the coadded energy histogram
including all 25-pixels was deltaE_FWHM = 1.66+/-0.02 eV and 3.34+/-0.06 eV at
an energy of 1.5 keV for the 25 micron and 50 micron absorber designs
respectively. Position discrimination is demonstrated from parameterization of
the rise-time.
[4]
oai:arXiv.org:1807.06092 [pdf] - 1717296
The Athena X-ray Integral Field Unit
Barret, Didier;
Trong, Thien Lam;
Herder, Jan-Willem den;
Piro, Luigi;
Cappi, Massimo;
Huovelin, Juhani;
Kelley, Richard;
Mas-Hesse, J. Miguel;
Mitsuda, Kazuhisa;
Paltani, Stéphane;
Rauw, Gregor;
Rozanska, Agata;
Wilms, Joern;
Bandler, Simon;
Barbera, Marco;
Barcons, Xavier;
Bozzo, Enrico;
Ceballos, Maria Teresa;
Charles, Ivan;
Costantini, Elisa;
Decourchelle, Anne;
Hartog, Roland den;
Duband, Lionel;
Duval, Jean-Marc;
Fiore, Fabrizio;
Gatti, Flavio;
Goldwurm, Andrea;
Jackson, Brian;
Jonker, Peter;
Kilbourne, Caroline;
Macculi, Claudio;
Mendez, Mariano;
Molendi, Silvano;
Orleanski, Piotr;
Pajot, François;
Pointecouteau, Etienne;
Porter, Frederick;
Pratt, Gabriel W.;
Prêle, Damien;
Ravera, Laurent;
Sato, Kosuke;
Schaye, Joop;
Shinozaki, Keisuke;
Thibert, Tanguy;
Valenziano, Luca;
Valette, Veronique;
Vink, Jacco;
Webb, Natalie;
Wise, Michael;
Yamasaki, Noriko;
Delcelier-Douchin, Françoise;
Mesnager, Jean-Michel;
Pontet, Bernard;
Pradines, Alice;
Branduardi-Raymont, Graziella;
Bulbul, Esra;
Dadina, Mauro;
Ettori, Stefano;
Finoguenov, Alexis;
Fukazawa, Yasushi;
Janiuk, Agnieszka;
Kaastra, Jelle;
Mazzotta, Pasquale;
Miller, Jon;
Miniutti, Giovanni;
Nazé, Yaël;
Nicastro, Fabrizio;
Sciortino, Salvatore;
Simionescu, Aurora;
Torrejon, Jose Miguel;
Frezouls, Benoît;
Geoffray, Hervé;
Peille, Philippe;
Aicardi, Corinne;
André, Jérôme;
Clénet, Antoine;
Daniel, Christophe;
Etcheverry, Christophe;
Gloaguen, Emilie;
Hervet, Gilles;
Jolly, Antoine;
Ledot, Aurélien;
Maussang, Irwin;
Paillet, Alexis;
Schmisser, Roseline;
Vella, Bruno;
Damery, Jean-Charles;
Boyce, Kevin;
DiPirro, Michael;
Lotti, Simone;
Schwander, Denis;
Smith, Stephen;
van Leeuwen, Bert-Joost;
van Weers, Henk;
Clerc, Nicolas;
Cobo, Beatriz;
Dauser, Thomas;
de Plaa, Jelle;
Kirsch, Christian;
Cucchetti, Edoardo;
Eckart, Megan;
Ferrando, Philippe;
Natalucci, Lorenzo
Submitted: 2018-07-16
The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray
spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5'
equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a
spectral resolution of 2.5 eV up to 7 keV on ~5 arcsecond pixels. The X-IFU is
based on a large format array of super-conducting molybdenum-gold Transition
Edge Sensors cooled at about 90 mK, each coupled with an absorber made of gold
and bismuth with a pitch of 249 microns. A cryogenic anti-coincidence detector
located underneath the prime TES array enables the non X-ray background to be
reduced. A bath temperature of about 50 mK is obtained by a series of
mechanical coolers combining 15K Pulse Tubes, 4K and 2K Joule-Thomson coolers
which pre-cool a sub Kelvin cooler made of a 3He sorption cooler coupled with
an Adiabatic Demagnetization Refrigerator. Frequency domain multiplexing
enables to read out 40 pixels in one single channel. A photon interacting with
an absorber leads to a current pulse, amplified by the readout electronics and
whose shape is reconstructed on board to recover its energy with high accuracy.
The defocusing capability offered by the Athena movable mirror assembly enables
the X-IFU to observe the brightest X-ray sources of the sky (up to Crab-like
intensities) by spreading the telescope point spread function over hundreds of
pixels. Thus the X-IFU delivers low pile-up, high throughput (>50%), and
typically 10 eV spectral resolution at 1 Crab intensities, i.e. a factor of 10
or more better than Silicon based X-ray detectors. In this paper, the current
X-IFU baseline is presented, together with an assessment of its anticipated
performance in terms of spectral resolution, background, and count rate
capability. The X-IFU baseline configuration will be subject to a preliminary
requirement review that is scheduled at the end of 2018.
[5]
oai:arXiv.org:1807.01582 [pdf] - 1710730
Testing the X-IFU calibration requirements: an example for quantum
efficiency and energy resolution
Cucchetti, Edoardo;
Pajot, François;
Pointecouteau, Etienne;
Peille, Philippe;
Betancourt-Martinez, Gabriele;
Smith, Stephen J.;
Barbera, Marco;
Eckart, Megan E.;
Bandler, Simon R.;
Kilbourne, Caroline A.;
Cappi, Massimo;
Barret, Didier
Submitted: 2018-07-04
With its array of 3840 Transition Edge Sensors (TESs) operated at 90 mK, the
X-Ray Integral Field Unit (X-IFU) on board the ESA L2 mission Athena will
provide spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7
keV) over the 0.2 to 12 keV bandpass. The in-flight performance of the X-IFU
will be strongly affected by the calibration of the instrument. Uncertainties
in the knowledge of the overall system, from the filter transmission to the
energy scale, may introduce systematic errors in the data, which could
potentially compromise science objectives - notably those involving line
characterisation e.g. turbulence velocity measurements - if not properly
accounted for. Defining and validating calibration requirements is therefore of
paramount importance. In this paper, we put forward a simulation tool based on
the most up-to-date configurations of the various subsystems (e.g. filters,
detector absorbers) which allows us to estimate systematic errors related to
uncertainties in the instrumental response. Notably, the effect of
uncertainties in the energy resolution and of the instrumental quantum
efficiency on X-IFU observations is assessed, by taking as a test case the
measurements of the iron K complex in the hot gas surrounding clusters of
galaxies. In-flight and ground calibration of the energy resolution and the
quantum efficiency is also addressed. We demonstrate that provided an accurate
calibration of the instrument, such effects should be low in both cases with
respect to statistics during observations.
[6]
oai:arXiv.org:1701.00795 [pdf] - 1534088
Solving the Coronal Heating Problem using X-ray Microcalorimeters
Christe, Steven;
Bandler, Simon;
DeLuca, Edward;
Caspi, Amir;
Golub, Leon;
Smith, Randall;
Allred, Joel;
Brosius, Jeffrey W.;
Dennis, Brian;
Klimchuk, James
Submitted: 2017-01-03
Even in the absence of resolved flares, the corona is heated to several
million degrees. However, despite its importance for the structure, dynamics,
and evolution of the solar atmosphere, the origin of this heating remains
poorly understood. Several observational and theoretical considerations suggest
that the heating is driven by small, impulsive energy bursts which could be
Parker-style "nanoflares" (Parker 1988) that arise via reconnection within the
tangled and twisted coronal magnetic field. The classical "smoking gun"
(Klimchuk 2009; Cargill et al. 2013) for impulsive heating is the direct
detection of widespread hot plasma (T > 6 MK) with a low emission measure. In
recent years there has been great progress in the development of Transition
Edge Sensor (TES) X-ray microcalorimeters that make them more ideal for
studying the Sun. When combined with grazing-incidence focusing optics, they
provide direct spectroscopic imaging over a broad energy band (0.5 to 10 keV)
combined with extremely impressive energy resolution in small pixels, as low as
0.7 eV (FWHM) at 1.5 keV (Lee 2015), and 1.56 eV (FWHM) at 6 keV (Smith 2012),
two orders of magnitude better than the current best traditional solid state
photon-counting spectrometers. Decisive observations of the hot plasma
associated with nanoflare models of coronal heating can be provided by new
solar microcalorimeters. These measurements will cover the most important part
of the coronal spectrum for searching for the nanoflare-related hot plasma and
will characterize how much nanoflares can heat the corona both in active
regions and the quiet Sun. Finally, microcalorimeters will enable to study all
of this as a function of time and space in each pixel simultaneously a
capability never before available.
[7]
oai:arXiv.org:1611.00956 [pdf] - 1521434
Development of frequency domain multiplexing for the X-ray Integral
Field Unit (X-IFU) on the Athena
Akamatsu, Hiroki;
Gottardi, Luciano;
van der Kuur, Jan;
de Vries, Cor P.;
Ravensberg, Kevin;
Adams, Joseph S.;
Bandler, Simon R.;
Bruijn, Marcel P.;
Chervenak, James A.;
Kilbourne, Caroline A;
Kiviranta, Mikko;
Linden, A. J. van den;
Jackson, Brian D.;
Smith, Stephen J.
Submitted: 2016-11-03
We are developing the frequency domain multiplexing (FDM) read-out of
transition-edge sensor (TES) microcalorimeters for the X-ray Integral Field
Unit (X-IFU) instrument on board of the future European X-Ray observatory
Athena. The X-IFU instrument consists of an array of $\sim$3840 TESs with a
high quantum efficiency ($>$90 \%) and spectral resolution $\Delta E$=2.5 eV
$@$ 7 keV ($E/\Delta E\sim$2800). FDM is currently the baseline readout system
for the X-IFU instrument. Using high quality factor LC filters and room
temperature electronics developed at SRON and low-noise two stage SQUID
amplifiers provided by VTT, we have recently demonstrated good performance with
the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. An integrated
noise equivalent power resolution of about 2.0 eV at 1.7 MHz has been
demonstrated with a pixel from a new TES array from NASA/Goddard (GSFC-A2). We
have achieved X-ray energy resolutions $\sim$2.5 eV at AC bias frequency at 1.7
MHz in the single pixel read-out. We have also demonstrated for the first time
an X-ray energy resolution around 3.0 eV in a 6 pixel FDM read-out with TES
array (GSFC-A1). In this paper we report on the single pixel performance of
these microcalorimeters under MHz AC bias, and further results of the
performance of these pixels under FDM.
[8]
oai:arXiv.org:1608.08105 [pdf] - 1467926
The Athena X-ray Integral Field Unit (X-IFU)
Barret, Didier;
Trong, Thien Lam;
Herder, Jan-Willem den;
Piro, Luigi;
Barcons, Xavier;
Huovelin, Juhani;
Kelley, Richard;
Mas-Hesse, J. Miguel;
Mitsuda, Kazuhisa;
Paltani, Stéphane;
Rauw, Gregor;
Rożanska, Agata;
Wilms, Joern;
Barbera, Marco;
Bozzo, Enrico;
Ceballos, Maria Teresa;
Charles, Ivan;
Decourchelle, Anne;
Hartog, Roland den;
Duval, Jean-Marc;
Fiore, Fabrizio;
Gatti, Flavio;
Goldwurm, Andrea;
Jackson, Brian;
Jonker, Peter;
Kilbourne, Caroline;
Macculi, Claudio;
Mendez, Mariano;
Molendi, Silvano;
Orleanski, Piotr;
Pajot, François;
Pointecouteau, Etienne;
Porter, Frederick;
Pratt, Gabriel W.;
Prêle, Damien;
Ravera, Laurent;
Renotte, Etienne;
Schaye, Joop;
Shinozaki, Keisuke;
Valenziano, Luca;
Vink, Jacco;
Webb, Natalie;
Yamasaki, Noriko;
Delcelier-Douchin, Françoise;
Du, Michel Le;
Mesnager, Jean-Michel;
Pradines, Alice;
Branduardi-Raymont, Graziella;
Dadina, Mauro;
Finoguenov, Alexis;
Fukazawa, Yasushi;
Janiuk, Agnieszka;
Miller, Jon;
Nazé, Yaël;
Nicastro, Fabrizio;
Sciortino, Salvatore;
Torrejon, Jose Miguel;
Geoffray, Hervé;
Hernandez, Isabelle;
Luno, Laure;
Peille, Philippe;
André, Jérôme;
Daniel, Christophe;
Etcheverry, Christophe;
Gloaguen, Emilie;
Hassin, Jérémie;
Hervet, Gilles;
Maussang, Irwin;
Moueza, Jérôme;
Paillet, Alexis;
Vella, Bruno;
Garrido, Gonzalo Campos;
Damery, Jean-Charles;
Panem, Chantal;
Panh, Johan;
Bandler, Simon;
Biffi, Jean-Marc;
Boyce, Kevin;
Clénet, Antoine;
DiPirro, Michael;
Jamotton, Pierre;
Lotti, Simone;
Schwander, Denis;
Smith, Stephen;
van Leeuwen, Bert-Joost;
van Weers, Henk;
Brand, Thorsten;
Cobo, Beatriz;
Dauser, Thomas;
de Plaa, Jelle;
Cucchetti, Edoardo
Submitted: 2016-08-29
The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for
High-ENergy Astrophysics (Athena) will provide spatially resolved
high-resolution X-ray spectroscopy from 0.2 to 12 keV, with 5 arc second pixels
over a field of view of 5 arc minute equivalent diameter and a spectral
resolution of 2.5 eV up to 7 keV. In this paper, we first review the core
scientific objectives of Athena, driving the main performance parameters of the
X-IFU, namely the spectral resolution, the field of view, the effective area,
the count rate capabilities, the instrumental background. We also illustrate
the breakthrough potential of the X-IFU for some observatory science goals.
Then we briefly describe the X-IFU design as defined at the time of the mission
consolidation review concluded in May 2016, and report on its predicted
performance. Finally, we discuss some options to improve the instrument
performance while not increasing its complexity and resource demands (e.g.
count rate capability, spectral resolution).
The X-IFU will be provided by an international consortium led by France, The
Netherlands and Italy, with further ESA member state contributions from
Belgium, Finland, Germany, Poland, Spain, Switzerland and two international
partners from the United States and Japan.
[9]
oai:arXiv.org:1311.5243 [pdf] - 749819
Solar Eruptive Events (SEE) 2020 Mission Concept
Lin, R. P.;
Caspi, A.;
Krucker, S.;
Hudson, H.;
Hurford, G.;
Bandler, S.;
Christe, S.;
Davila, J.;
Dennis, B.;
Holman, G.;
Milligan, R.;
Shih, A. Y.;
Kahler, S.;
Kontar, E.;
Wiedenbeck, M.;
Cirtain, J.;
Doschek, G.;
Share, G. H.;
Vourlidas, A.;
Raymond, J.;
Smith, D. M.;
McConnell, M.;
Emslie, G.
Submitted: 2013-11-20
Major solar eruptive events (SEEs), consisting of both a large flare and a
near simultaneous large fast coronal mass ejection (CME), are the most powerful
explosions and also the most powerful and energetic particle accelerators in
the solar system, producing solar energetic particles (SEPs) up to tens of GeV
for ions and hundreds of MeV for electrons. The intense fluxes of escaping SEPs
are a major hazard for humans in space and for spacecraft. Furthermore, the
solar plasma ejected at high speed in the fast CME completely restructures the
interplanetary medium (IPM) - major SEEs therefore produce the most extreme
space weather in geospace, the interplanetary medium, and at other planets.
Thus, understanding the flare/CME energy release process(es) and the related
particle acceleration processes are major goals in Heliophysics. To make the
next major breakthroughs, we propose a new mission concept, SEE 2020, a single
spacecraft with a complement of advanced new instruments that focus directly on
the coronal energy release and particle acceleration sites, and provide the
detailed diagnostics of the magnetic fields, plasmas, mass motions, and
energetic particles required to understand the fundamental physical processes
involved.
[10]
oai:arXiv.org:1308.6784 [pdf] - 713384
The Hot and Energetic Universe: The X-ray Integral Field Unit (X-IFU)
for Athena+
Barret, D.;
Herder, J. W. den;
Piro, L.;
Ravera, L.;
Hartog, R. Den;
Macculi, C.;
Barcons, X.;
Page, M.;
Paltani, S.;
Rauw, G.;
Wilms, J.;
Ceballos, M.;
Duband, L.;
Gottardi, L.;
Lotti, S.;
de Plaa, J.;
Pointecouteau, E.;
Schmid, C.;
Akamatsu, H.;
Bagliani, D.;
Bandler, S.;
Barbera, M.;
Bastia, P.;
Biasotti, M.;
Branco, M.;
Camon, A.;
Cara, C.;
Cobo, B.;
Colasanti, L.;
Costa-Kramer, J. L.;
Corcione, L.;
Doriese, W.;
Duval, J. M.;
Fabrega, L.;
Gatti, F.;
de Gerone, M.;
Guttridge, P.;
Kelley, R.;
Kilbourne, C.;
van der Kuur, J.;
Mineo, T.;
Mitsuda, K.;
Natalucci, L.;
Ohashi, T.;
Peille, P.;
Perinati, E.;
Pigot, C.;
Pizzigoni, G.;
Pobes, C.;
Porter, F.;
Renotte, E.;
Sauvageot, J. L.;
Sciortino, S.;
Torrioli, G.;
Valenziano, L.;
Willingale, D.;
de Vries, C.;
van Weers, H.
Submitted: 2013-08-30
The Athena+ mission concept is designed to implement the Hot and Energetic
Universe science theme submitted to the European Space Agency in response to
the call for White Papers for the definition of the L2 and L3 missions of its
science program. The Athena+ science payload consists of a large aperture high
angular resolution X-ray optics and twelve meters away, two interchangeable
focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide
Field Imager (WFI). The X-IFU is a cryogenic X-ray spectrometer, based on a
large array of Transition Edge Sensors (TES), offering 2.5 eV spectral
resolution, with ~5" pixels, over a field of view of 5 arc minutes in diameter.
In this paper, we briefly describe the Athena+ mission concept and the X-IFU
performance requirements. We then present the X-IFU detector and readout
electronics principles, the current design of the focal plane assembly, the
cooling chain and review the global architecture design. Finally, we describe
the current performance estimates, in terms of effective area, particle
background rejection, count rate capability and velocity measurements. Finally,
we emphasize on the latest technology developments concerning TES array
fabrication, spectral resolution and readout performance achieved to show that
significant progresses are being accomplished towards the demanding X-IFU
requirements.
[11]
oai:arXiv.org:1112.1327 [pdf] - 447714
The Extreme Physics Explorer
Garcia, Michael;
Elvis, Martin;
Bookbinder, Jay;
Brenneman, Laura;
Bulbul, Esra;
Nulsen, Paul;
Patnaude, Dan;
Smith, Randall;
Bandler, Simon;
Okajima, Takashi;
Ptak, Andy;
Figueroa-Feliciano, Enectali;
Chakrabarty, Deepto;
Danner, Rolf;
Daily, Dean;
Fraser, George;
Willingale, Richard;
Miller, Jon;
Turner, T. J.;
Risalti, Guido;
Galeazzi, Massimiliano
Submitted: 2011-12-06
A non-proprietary Mission Concept available for presentation to NASA,
providing High Area, High Resolution Imaging Spectroscopy and Timing with
Arcmin Angular Resolution Submitted in response to NASA 2011 RFI NNH11ZDA018L
'Concepts for the Next NASA X-ray Astronomy Mission'
[12]
oai:arXiv.org:1108.4632 [pdf] - 1083577
Proximity Effects and Nonequilibrium Superconductivity in
Transition-Edge Sensors
Submitted: 2011-08-23
We have recently shown that normal-metal/superconductor (N/S) bilayer TESs
(superconducting Transition-Edge Sensors) exhibit weak-link behavior.1 Here we
extend our understanding to include TESs with added noise-mitigating
normal-metal structures (N structures). We find TESs with added Au structures
also exhibit weak-link behavior as evidenced by exponential temperature
dependence of the critical current and Josephson-like oscillations of the
critical current with applied magnetic field. We explain our results in terms
of an effect converse to the longitudinal proximity effect (LoPE)1, the lateral
inverse proximity effect (LaiPE), for which the order parameter in the N/S
bilayer is reduced due to the neighboring N structures. Resistance and critical
current measurements are presented as a function of temperature and magnetic
field taken on square Mo/Au bilayer TESs with lengths ranging from 8 to 130
{\mu}m with and without added N structures. We observe the inverse proximity
effect on the bilayer over in-plane distances many tens of microns and find the
transition shifts to lower temperatures scale approximately as the inverse
square of the in- plane N-structure separation distance, without appreciable
broadening of the transition width. We also present evidence for nonequilbrium
superconductivity and estimate a quasiparticle lifetime of 1.8 \times 10-10 s
for the bilayer. The LoPE model is also used to explain the increased
conductivity at temperatures above the bilayer's steep resistive transition.
[13]
oai:arXiv.org:1104.2048 [pdf] - 576598
ORIGIN: Metal Creation and Evolution from the Cosmic Dawn
Herder, J. W. den;
Piro, L.;
Ohashi, T.;
Kouveliotou, C.;
Hartmann, D. H.;
Kaastra, J. S.;
Amati, L.;
Andersen, M. I.;
Arnaud, M.;
Attéia, J-L.;
Bandler, S.;
Barbera, M.;
Barcons, X.;
Barthelmy, S.;
Basa, S.;
Basso, S.;
Boer, M.;
Branchini, E.;
Branduardi-Raymont, G.;
Borgani, S.;
Boyarsky, A.;
Brunetti, G.;
Budtz-Jorgensen, C.;
Burrows, D.;
Butler, N.;
Campana, S.;
Caroli, E.;
Ceballos, M.;
Christensen, F.;
Churazov, E.;
Comastri, A.;
Colasanti, L.;
Cole, R.;
Content, R.;
Corsi, A.;
Costantini, E.;
Conconi, P.;
Cusumano, G.;
de Plaa, J.;
De Rosa, A.;
Del Santo, M.;
Di Cosimo, S.;
De Pasquale, M.;
Doriese, R.;
Ettori, S.;
Evans, P.;
Ezoe, Y.;
Ferrari, L.;
Finger, H.;
Figueroa-Feliciano, T.;
Friedrich, P.;
Fujimoto, R.;
Furuzawa, A.;
Fynbo, J.;
Gatti, F.;
Galeazzi, M.;
Gehrels, N.;
Gendre, B.;
Ghirlanda, G.;
Ghisellini, G.;
Gilfanov, M.;
Giommi, P.;
Girardi, M.;
Grindlay, J.;
Cocchi, M.;
Godet, O.;
Guedel, M.;
Haardt, F.;
Hartog, R. den;
Hepburn, I.;
Hermsen, W.;
Hjorth, J.;
Hoekstra, H.;
Holland, A.;
Hornstrup, A.;
van der Horst, A.;
Hoshino, A.;
Zand, J. in 't;
Irwin, K.;
Ishisaki, Y.;
Jonker, P.;
Kitayama, T.;
Kawahara, H.;
Kawai, N.;
Kelley, R.;
Kilbourne, C.;
de Korte, P.;
Kusenko, A.;
Kuvvetli, I.;
Labanti, M.;
Macculi, C.;
Maiolino, R.;
Hesse, M. Mas;
Matsushita, K.;
Mazzotta, P.;
McCammon, D.;
Méndez, M.;
Mignani, R.;
Mineo, T.;
Mitsuda, K.;
Mushotzky, R.;
Molendi, S.;
Moscardini, L.;
Natalucci, L.;
Nicastro, F.;
O'Brien, P.;
Osborne, J.;
Paerels, F.;
Page, M.;
Paltani, S.;
Pedersen, K.;
Perinati, E.;
Ponman, T.;
Pointecouteau, E.;
Predehl, P.;
Porter, S.;
Rasmussen, A.;
Rauw, G.;
Röttgering, H.;
Roncarelli, M.;
Rosati, P.;
Quadrini, E.;
Ruchayskiy, O.;
Salvaterra, R.;
Sasaki, S.;
Sato, K.;
Savaglio, S.;
Schaye, J.;
Sciortino, S.;
Shaposhnikov, M.;
Sharples, R.;
Shinozaki, K.;
Spiga, D.;
Sunyaev, R.;
Suto, Y.;
Takei, Y.;
Tanvir, N.;
Tashiro, M.;
Tamura, T.;
Tawara, Y.;
Troja, E.;
Tsujimoto, M.;
Tsuru, T.;
Ubertini, P.;
Ullom, J.;
Ursino, E.;
Verbunt, F.;
van de Voort, F.;
Viel, M.;
Wachter, S.;
Watson, D.;
Weisskopf, M.;
Werner, N.;
White, N.;
Willingale, R.;
Wijers, R.;
Yamasaki, N.;
Yoshikawa, K.;
Zane, S.
Submitted: 2011-04-11, last modified: 2011-04-15
ORIGIN is a proposal for the M3 mission call of ESA aimed at the study of
metal creation from the epoch of cosmic dawn. Using high-spectral resolution in
the soft X-ray band, ORIGIN will be able to identify the physical conditions of
all abundant elements between C and Ni to red-shifts of z=10, and beyond. The
mission will answer questions such as: When were the first metals created? How
does the cosmic metal content evolve? Where do most of the metals reside in the
Universe? What is the role of metals in structure formation and evolution? To
reach out to the early Universe ORIGIN will use Gamma-Ray Bursts (GRBs) to
study their local environments in their host galaxies. This requires the
capability to slew the satellite in less than a minute to the GRB location. By
studying the chemical composition and properties of clusters of galaxies we can
extend the range of exploration to lower redshifts (z ~ 0.2). For this task we
need a high-resolution spectral imaging instrument with a large field of view.
Using the same instrument, we can also study the so far only partially detected
baryons in the Warm-Hot Intergalactic Medium (WHIM). The less dense part of the
WHIM will be studied using absorption lines at low redshift in the spectra for
GRBs.
[14]
oai:arXiv.org:1011.4052 [pdf] - 264469
Science Objectives for an X-Ray Microcalorimeter Observing the Sun
Laming, J. Martin;
Adams, J.;
Alexander, D.;
Aschwanden, M;
Bailey, C.;
Bandler, S.;
Bookbinder, J.;
Bradshaw, S.;
Brickhouse, N.;
Chervenak, J.;
Christe, S.;
Cirtain, J.;
Cranmer, S.;
Deiker, S.;
DeLuca, E.;
Del Zanna, G.;
Dennis, B.;
Doschek, G.;
Eckart, M.;
Fludra, A.;
Finkbeiner, F.;
Grigis, P.;
Harrison, R.;
Ji, L.;
Kankelborg, C.;
Kashyap, V.;
Kelly, D.;
Kelley, R.;
Kilbourne, C.;
Klimchuk, J.;
Ko, Y. -K.;
Landi, E.;
Linton, M.;
Longcope, D.;
Lukin, V.;
Mariska, J.;
Martinez-Galarce, D.;
Mason, H.;
McKenzie, D.;
Osten, R.;
Peres, G.;
Pevtsov, A.;
Porter, K. Phillips F. S.;
Rabin, D.;
Rakowski, C.;
Raymond, J.;
Reale, F.;
Reeves, K.;
Sadleir, J.;
Savin, D.;
Schmelz, J.;
Smith, R. K.;
Smith, S.;
Stern, R.;
Sylwester, J.;
Tripathi, D.;
Ugarte-Urra, I.;
Young, P.;
Warren, H.;
Wood, B.
Submitted: 2010-11-17
We present the science case for a broadband X-ray imager with high-resolution
spectroscopy, including simulations of X-ray spectral diagnostics of both
active regions and solar flares. This is part of a trilogy of white papers
discussing science, instrument (Bandler et al. 2010), and missions (Bookbinder
et al. 2010) to exploit major advances recently made in transition-edge sensor
(TES) detector technology that enable resolution better than 2 eV in an array
that can handle high count rates. Combined with a modest X-ray mirror, this
instrument would combine arcsecondscale imaging with high-resolution spectra
over a field of view sufficiently large for the study of active regions and
flares, enabling a wide range of studies such as the detection of microheating
in active regions, ion-resolved velocity flows, and the presence of non-thermal
electrons in hot plasmas. It would also enable more direct comparisons between
solar and stellar soft X-ray spectra, a waveband in which (unusually) we
currently have much better stellar data than we do of the Sun.
[15]
oai:arXiv.org:0910.2451 [pdf] - 902050
Longitudinal Proximity Effects in Superconducting Transition-Edge
Sensors
Submitted: 2009-10-13
We have found experimentally that the critical current of a square
superconducting transition-edge sensor (TES) depends exponentially upon the
side length L and the square root of the temperature T. As a consequence, the
effective transition temperature Tc of the TES is current-dependent and at
fixed current scales as 1/L^2. We also have found that the critical current can
show clear Fraunhofer-like oscillations in an applied magnetic field, similar
to those found in Josephson junctions. The observed behavior has a natural
theoretical explanation in terms of longitudinal proximity effects if the TES
is regarded as a weak link between superconducting leads. We have observed the
proximity effect in these devices over extraordinarily long lengths exceeding
100 um.