Normalized to: Bancroft, C.
[1]
oai:arXiv.org:1602.07581 [pdf] - 1363984
Balloon Flight Test of a Compton Telescope Based on Scintillators with
Silicon Photomultiplier Readouts
Submitted: 2016-02-24
We present the results of the first high-altitude balloon flight test of a
concept for an advanced Compton telescope making use of modern scintillator
materials with silicon photomultiplier (SiPM) readouts. There is a need in the
fields of high-energy astronomy and solar physics for new medium-energy
gamma-ray (~0.4 - 10 MeV) detectors capable of making sensitive observations. A
fast scintillator- based Compton telescope with SiPM readouts is a promising
solution to this instrumentation challenge, since the fast response of the
scintillators permits the rejection of background via time-of-flight (ToF)
discrimination. The Solar Compton Telescope (SolCompT) prototype was designed
to demonstrate stable performance of this technology under balloon-flight
conditions. The SolCompT instrument was a simple two-element Compton telescope,
consisting of an approximately one-inch cylindrical stilbene crystal for a
scattering detector and a one-inch cubic LaBr3:Ce crystal for a calorimeter
detector. Both scintillator detectors were read out by 2 x 2 arrays of
Hamamatsu S11828-3344 MPPC devices. Custom front-end electronics provided
optimum signal rise time and linearity, and custom power supplies automatically
adjusted the SiPM bias voltage to compensate for temperature-induced gain
variations. A tagged calibration source, consisting of ~240 nCi of Co-60
embedded in plastic scintillator, was placed in the field of view and provided
a known source of gamma rays to measure in flight. The SolCompT balloon payload
was launched on 24 August 2014 from Fort Sumner, NM, and spent ~3.75 hours at a
float altitude of ~123,000 feet. The instrument performed well throughout the
flight. After correcting for small (~10%) residual gain variations, we measured
an in-flight ToF resolution of ~760 ps (FWHM). Advanced scintillators with SiPM
readouts continue to show great promise for future gamma-ray instruments.
[2]
oai:arXiv.org:0812.0782 [pdf] - 19123
Calibration of the Gamma-RAy Polarimeter Experiment (GRAPE) at a
Polarized Hard X-Ray Beam
Submitted: 2008-12-03
The Gamma-RAy Polarimeter Experiment (GRAPE) is a concept for an astronomical
hard X-ray Compton polarimeter operating in the 50 - 500 keV energy band. The
instrument has been optimized for wide-field polarization measurements of
transient outbursts from energetic astrophysical objects such as gamma-ray
bursts and solar flares. The GRAPE instrument is composed of identical modules,
each of which consists of an array of scintillator elements read out by a
multi-anode photomultiplier tube (MAPMT). Incident photons Compton scatter in
plastic scintillator elements and are subsequently absorbed in inorganic
scintillator elements; a net polarization signal is revealed by a
characteristic asymmetry in the azimuthal scattering angles. We have
constructed a prototype GRAPE module containing a single CsI(Na) calorimeter
element, at the center of the MAPMT, surrounded by 60 plastic elements. The
prototype has been combined with custom readout electronics and software to
create a complete "engineering model" of the GRAPE instrument. This engineering
model has been calibrated using a nearly 100% polarized hard X-ray beam at the
Advanced Photon Source at Argonne National Laboratory. We find modulation
factors of 0.46 +/- 0.06 and 0.48 +/- 0.03 at 69.5 keV and 129.5 keV,
respectively, in good agreement with Monte Carlo simulations. In this paper we
present details of the beam test, data analysis, and simulations, and discuss
the implications of our results for the further development of the GRAPE
concept.