sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Balasubramanyam, R.

Normalized to: Balasubramanyam, R.

5 article(s) in total. 39 co-authors, from 1 to 2 common article(s). Median position in authors list is 2,0.

[1]  oai:arXiv.org:0910.2946  [pdf] - 29564
12 GHz Radio-Holographic surface measurement of the RRI 10.4 m telescope
Comments: 4 pages, 5 figures, ASP Conference Series, Vol. LFRU, 2009
Submitted: 2009-10-15
A modern Q-band low noise amplifier (LNA) front-end is being fitted to the 10.4 m millimeter-wave telescope at the Raman Research Institute (RRI) to support observations in the 40-50 GHz frequency range. To assess the suitability of the surface for this purpose, we measured the deviations of the primary surface from an ideal paraboloid using radio holography. We used the 11.6996 GHz beacon signal from the GSAT3 satellite, a 1.2 m reference antenna, commercial Ku-band Low Noise Block Convereters (LNBC) as the receiver front-ends and a Stanford Research Systems (SRS) lock-in amplifier as the backend. The LNBCs had independent free-running first local oscillators (LO). Yet, we recovered the correlation by using a radiatively injected common tone that served as the second local oscillator. With this setup, we mapped the surface deviations on a 64 x 64 grid and measured an rms surface deviation of ~350 um with a measurement accuracy of ~50 um.
[2]  oai:arXiv.org:0812.1708  [pdf] - 19305
Physical and chemical conditions in methanol maser selected hot-cores and UCHII regions
Comments:
Submitted: 2008-12-09
We present the results of a targeted 3-mm spectral line survey towards the eighty-three 6.67 GHz methanol maser selected star forming clumps observed by Purcell et al. 2006. In addition to the previously reported measurements of HCO+ (1 - 0), H13CO+ (1 - 0), and CH3CN (5 - 4) & (6 -5), we used the Mopra antenna to detect emission lines of N2H+ (1 - 0), HCN (1 - 0) and HNC (1 - 0) towards 82/83 clumps (99 per cent), and CH3OH (2 - 1) towards 78/83 clumps (94 per cent). The molecular line data have been used to derive virial and LTE masses, rotational temperatures and chemical abundances in the clumps, and these properties have been compared between sub-samples associated with different indicators of evolution. The greatest differences are found between clumps associated with 8.6 GHz radio emission, indicating the presence of an Ultra-Compact HII region, and `isolated' masers (without associated radio emission), and between clumps exhibiting CH3CN emission and those without. In particular, thermal CH3OH is found to be brighter and more abundant in Ultra-Compact HII (UCHII) regions and in sources with detected CH3CN, and may constitute a crude molecular clock in single dish observations. Clumps associated with 8.6 GHz radio emission tend to be more massive and more luminous than clumps without radio emission. This is likely because the most massive clumps evolve so rapidly that a Hyper-Compact HII or UCHII region is the first visible tracer of star-formation. The gas-mass to sub-mm/IR luminosity relation for the combined sample was found to be L proportional to M**0.68, considerably shallower than expected for massive main-sequence stars.
[3]  oai:arXiv.org:astro-ph/0703643  [pdf] - 90452
HI imaging of galaxies in X-ray bright groups
Comments: Accepted in MNRAS
Submitted: 2007-03-26
Environment plays an important role in the evolution of the gas contents of galaxies. Gas deficiency of cluster spirals and the role of the hot intracluster medium (ICM) in stripping gas from these galaxies is a well studied subject. Loose groups with diffuse X-ray emmision from the intragroup medium (IGM) offer an intermediate environment between clusters and groups without a hot IGM. These X-ray bright groups have smaller velocity dispersion and lower temperature than clusters, but higher IGM density than loose groups without diffuse X-ray emission. A single dish comparative study of loose groups with and without diffuse X-ray emission from the IGM, showed that the galaxies in X-ray bright groups have lost more gas on average than the galaxies in non X-ray bright groups. In this paper we present GMRT HI observations of 13 galaxies from 4 X-ray bright groups: NGC5044, NGC720, NGC1550 and IC1459. The aim of this work is to study the morphology of HI in these galaxies and to see if the hot IGM has in any way affected their HI content or distribution. In addition to disturbed HI morphology, we find that most galaxies have shrunken HI disks compared to the field spirals. This indicates that IGM assisted stripping processes like ram pressure may have stripped gas from the outer edges of the galaxies.
[4]  oai:arXiv.org:astro-ph/0604020  [pdf] - 81089
HI content in galaxies in loose groups
Comments: 9 pages, 4 figures, accepted in MNRAS
Submitted: 2006-04-03
Gas deficiency in cluster spirals is well known and ram-pressure stripping is considered the main gas removal mechanism. In some compact groups too gas deficiency is reported. However, gas deficiency in loose groups is not yet well established. Lower dispersion of the member velocities and the lower density of the intra-group medium in small loose groups favour tidal stripping as the main gas removal process in them. Recent releases of data from HI Parkes all sky survey (HIPASS) and catalogues of nearby loose groups with associated diffuse X-ray emission have allowed us to test this notion. In this paper, we address the following questions: (a) do galaxies in groups with diffuse X-ray emission statistically have lower gas content compared to the ones in groups without diffuse X-ray emission? (b) does HI deficiency vary with the X-ray luminosity of the loose group in a systematic way? We find that (a) galaxies in groups with diffuse X-ray emission, on average, are HI deficient, and have lost more gas compared to those in groups without X-ray emission; the later are found not to have significant HI deficiency; (b) no systematic dependence of the HI deficiency with X-ray luminosity is found. Ram pressure assisted tidal stripping and evaporation by thermal conduction are the two possible mechanisms to account for this excess gas loss.
[5]  oai:arXiv.org:astro-ph/0512589  [pdf] - 78789
A CH3CN and HCO+ survey towards southern methanol masers associated with star formation
Comments: 29 pages, 16 figures. Accepted for publication in MNRAS. For associated online figures please see http://www.phys.unsw.edu.au/~crp/papers/cpurcell_2005_online.pdf
Submitted: 2005-12-23
We present the initial results of a 3-mm spectral line survey towards 83 methanol maser selected massive star-forming regions. Here we report observations of the J=5-4 and 6-5 rotational transitions of methyl cyanide (CH3CN) and the J=1-0 transition of HCO+and H13CO+. CH3CN emission is detected in 58 sources (70 %) of our sample). We estimate the temperature and column density for 37 of these using the rotational diagram method. The temperatures we derive range from 28-166 K, and are lower than previously reported temperatures, derived from higher J transitions. We find that CH3CN is brighter and more commonly detected towards ultra-compact HII (UCHII) regions than towards isolated maser sources. Detection of CH3CN towards isolated maser sources strongly suggests that these objects are internally heated and that CH3CN is excited prior to the UCHII phase of massive star-formation. HCO+ is detected towards 82 sources (99 % of our sample), many of which exhibit asymmetric line profiles compared to H13CO+. Skewed profiles are indicative of inward or outward motions, however, we find approximately equal numbers of red and blue-skewed profiles among all classes. Column densities are derived from an analysis of the HCO+ and H13CO+ line profiles. 80 sources have mid-infrared counterparts: 68 seen in emission and 12 seen in absorption as `dark clouds'. Seven of the twelve dark clouds exhibit asymmetric HCO+ profiles, six of which are skewed to the blue, indicating infalling motions. CH3CN is also common in dark clouds, where it has a 90 % detection rate.