oai:arXiv.org:2002.00599 [pdf] - 2041548
On Fabry-P\'erot Etalon-based Instruments. III. Instrument applications
Submitted: 2020-02-03
The spectral, imaging, and polarimetric behavior of Fabry-P\'erot etalons
have an influence on imaging vector magnetograph instruments based on these
devices. The impact depends, among others, on the optical configuration
(collimated or telecentric), on the relative position of the etalon with
respect to the polarimeter, on the type of etalon (air-gapped or crystalline),
and even on the polarimetric technique to be used (single-beam or dual-beam).
In this paper we evaluate the artificial line-of-sight velocities and magnetic
field strengths that arise in etalon-based instruments attending to the
mentioned factors. We differentiate between signals that are implicit to
telecentric mounts due to the wavelength dependence of the point-spread
function and those emerging in both collimated and telecentric setups from the
polarimetric response of birefringent etalons. For the anisotropic case we
consider two possible locations of the etalon, between the modulator and the
analyzer or after it, and we include the effect on different channels when
dual-beam polarimetry is employed. We also evaluate the impact of the loss of
symmetry produced in telecentric mounts due to imperfections in the
illumination and/or to a tilt of the etalon relative to the incident beam.
[2]
oai:arXiv.org:1906.10361 [pdf] - 1905952
On Fabry P\'erot Etalon based Instruments. II. The Anisotropic
(Birefringent) Case
Submitted: 2019-06-25
Crystalline etalons present several advantages with respect to other types of
filtergraphs when employed in magnetographs. Specially that they can be tuned
by only applying electric fields. However, anisotropic crystalline etalons can
also introduce undesired birefringent effects that corrupt the polarization of
the incoming light. In particular, uniaxial Fabry-P\'erots, such as LiNbO3
etalons, are birefringent when illuminated with an oblique beam. The farther
the incidence from the normal, the larger the induced retardance between the
two orthogonal polarization states. The application of high-voltages, as well
as fabrication defects, can also change the direction of the optical axis of
the crystal, introducing birefringence even at normal illumination. Here we
obtain analytical expressions for the induced retardance and for the Mueller
matrix of uniaxial etalons located in both collimated and telecentric
configurations. We also evaluate the polarimetric behavior of Z-cut crystalline
etalons with the incident angle, with the orientation of the optical axis, and
with the f-number of the incident beam for the telecentric case. We study
artificial signals produced in the output Stokes vector in the two
configurations. Last, we discuss the polarimetric dependence of the imaging
response of the etalon for both collimated and telecentric setups.
[3]
oai:arXiv.org:1903.06403 [pdf] - 1850008
On Fabry P\'erot Etalon based Instruments. I. The Isotropic Case
Submitted: 2019-03-15
Here we assess the spectral and imaging properties of Fabry P\'erot etalons
when located in solar magnetographs. We discuss the chosen configuration
(collimated or telecentric) for both ideal and real cases. For the real cases,
we focus on the effects caused by the polychromatic illumination of the filter
by the irregularities in the optical thickness of the etalon and by deviations
from the ideal illumination in both setups. We first review the general
properties of Fabry P\'erots and we then address the different sources of
degradation of the spectral transmission profile. We review and extend the
general treatment of defects followed by different authors. We discuss the
differences between the point spread functions (PSFs) of the collimated and
telecentric configurations for both monochromatic and (real)
quasi-monochromatic illumination of the etalon. The PSF corresponding to
collimated mounts is shown to have a better performance, although it varies
from point to point due to an apodization of the image inherent to this
configuration. This is in contrast to the (perfect) telecentric case, where the
PSF remains constant but produces artificial velocities and magnetic field
signals because of its strong spectral dependence. We find that the unavoidable
presence of imperfections in the telecentrism produces a decrease of flux of
photons and a shift, a broadening and a loss of symmetrization of both the
spectral and PSF profiles over the field of view, thus compromising their
advantages over the collimated configuration. We evaluate these effects for
different apertures of the incident beam.