Normalized to: Baba, N.
[1]
oai:arXiv.org:1507.00017 [pdf] - 1286958
The Subaru Coronagraphic Extreme Adaptive Optics system: enabling
high-contrast imaging on solar-system scales
Jovanovic, N.;
Martinache, F.;
Guyon, O.;
Clergeon, C.;
Singh, G.;
Kudo, T.;
Garrel, V.;
Newman, K.;
Doughty, D.;
Lozi, J.;
Males, J.;
Minowa, Y.;
Hayano, Y.;
Takato, N.;
Morino, J.;
Kuhn, J.;
Serabyn, E.;
Norris, B.;
Tuthill, P.;
Schworer, G.;
Stewart, P.;
Close, L.;
Huby, E.;
Perrin, G.;
Lacour, S.;
Gauchet, L.;
Vievard, S.;
Murakami, N.;
Oshiyama, F.;
Baba, N.;
Matsuo, T.;
Nishikawa, J.;
Tamura, M.;
Lai, O.;
Marchis, F.;
Duchene, G.;
Kotani, T.;
Woillez, J.
Submitted: 2015-06-30
The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument is a
multipurpose high-contrast imaging platform designed for the discovery and
detailed characterization of exoplanetary systems and serves as a testbed for
high-contrast imaging technologies for ELTs. It is a multi-band instrument
which makes use of light from 600 to 2500nm allowing for coronagraphic direct
exoplanet imaging of the inner 3 lambda/D from the stellar host. Wavefront
sensing and control are key to the operation of SCExAO. A partial correction of
low-order modes is provided by Subaru's facility adaptive optics system with
the final correction, including high-order modes, implemented downstream by a
combination of a visible pyramid wavefront sensor and a 2000-element deformable
mirror. The well corrected NIR (y-K bands) wavefronts can then be injected into
any of the available coronagraphs, including but not limited to the phase
induced amplitude apodization and the vector vortex coronagraphs, both of which
offer an inner working angle as low as 1 lambda/D. Non-common path, low-order
aberrations are sensed with a coronagraphic low-order wavefront sensor in the
infrared (IR). Low noise, high frame rate, NIR detectors allow for active
speckle nulling and coherent differential imaging, while the HAWAII 2RG
detector in the HiCIAO imager and/or the CHARIS integral field spectrograph
(from mid 2016) can take deeper exposures and/or perform angular, spectral and
polarimetric differential imaging. Science in the visible is provided by two
interferometric modules: VAMPIRES and FIRST, which enable sub-diffraction
limited imaging in the visible region with polarimetric and spectroscopic
capabilities respectively. We describe the instrument in detail and present
preliminary results both on-sky and in the laboratory.
[2]
oai:arXiv.org:1108.3157 [pdf] - 398626
The SPICA coronagraphic instrument (SCI) for the study of exoplanets
Enya, K.;
Kotani, T.;
Haze, K.;
Aono, K.;
Nakagawa, T.;
Matsuhara, H.;
Kataza, H.;
Wada, T.;
Kawada, M.;
Fujiwara, K.;
Mita, M.;
Takeuchi, S.;
Komatsu, K.;
Sakai, S.;
Uchida, H.;
Mitani, S.;
Yamawaki, T.;
Miyata, T.;
Sako, S.;
Nakamura, T.;
Asano, K.;
Yamashita, T.;
Narita, N.;
Matsuo, T.;
Tamura, M.;
Nishikawa, J.;
Kokubo, E.;
Hayano, Y.;
Oya, S.;
Fukagawa, M.;
Shibai, H.;
Baba, N.;
Murakami, N.;
Itoh, Y.;
Honda, M.;
Okamoto, B.;
Ida, S.;
Takami, M.;
Abe, L.;
Guyon, O.;
Bierden, P.;
Yamamuro, T.
Submitted: 2011-08-16
We present the SPICA Coronagraphic Instrument (SCI), which has been designed
for a concentrated study of extra-solar planets (exoplanets). SPICA mission
provides us with a unique opportunity to make high contrast observations
because of its large telescope aperture, the simple pupil shape, and the
capability for making infrared observations from space. The primary objectives
for the SCI are the direct coronagraphic detection and spectroscopy of Jovian
exoplanets in infrared, while the monitoring of transiting planets is another
important target. The specification and an overview of the design of the
instrument are shown. In the SCI, coronagraphic and non-coronagraphic modes are
applicable for both an imaging and a spectroscopy. The core wavelength range
and the goal contrast of the coronagraphic mode are 3.5--27$\mu$m, and
10$^{-6}$, respectively. Two complemental designs of binary shaped pupil mask
coronagraph are presented. The SCI has capability of simultaneous observations
of one target using two channels, a short channel with an InSb detector and a
long wavelength channel with a Si:As detector. We also give a report on the
current progress in the development of key technologies for the SCI.
[3]
oai:arXiv.org:0809.1510 [pdf] - 16122
An Eight-Octant Phase-Mask Coronagraph
Submitted: 2008-09-09
We present numerical simulations and laboratory experiments on an
eight-octant phase-mask (EOPM) coronagraph. The numerical simulations suggest
that an achievable contrast for the EOPM coronagraph can be greatly improved as
compared to that of a four-quadrant phase-mask (FQPM) coronagraph for a
partially resolved star. On-sky transmission maps reveal that the EOPM
coronagraph has relatively high optical throughput, a small inner working angle
and large discovery space. We have manufactured an eight-segment phase mask
utilizing a nematic liquid-crystal device, which can be easily switched between
the FQPM and the EOPM modes. The laboratory experiments demonstrate that the
EOPM coronagraph has a better tolerance of the tip-tilt error than the FQPM
one. We also discuss feasibility of a fully achromatic and high-throughput EOPM
coronagraph utilizing a polarization interferometric technique.