sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Baù, A.

Normalized to: Baù, A.

11 article(s) in total. 291 co-authors, from 1 to 11 common article(s). Median position in authors list is 7,0.

[1]  oai:arXiv.org:2005.01187  [pdf] - 2089273
Progress report on the Large Scale Polarization Explorer
Comments: 8 pages, 5 figures, Accepted for publication in Journal of Low Temperature Physics
Submitted: 2020-05-03, last modified: 2020-05-05
The Large Scale Polarization Explorer (LSPE) is a cosmology program for the measurement of large scale curl-like features (B-modes) in the polarization of the Cosmic Microwave Background. Its goal is to constrain the background of inflationary gravity waves traveling through the universe at the time of matter-radiation decoupling. The two instruments of LSPE are meant to synergically operate by covering a large portion of the northern microwave sky. LSPE/STRIP is a coherent array of receivers planned to be operated from the Teide Observatory in Tenerife, for the control and characterization of the low-frequency polarized signals of galactic origin; LSPE/SWIPE is a balloon-borne bolometric polarimeter based on 330 large throughput multi-moded detectors, designed to measure the CMB polarization at 150 GHz and to monitor the polarized emission by galactic dust above 200 GHz. The combined performance and the expected level of systematics mitigation will allow LSPE to constrain primordial B-modes down to a tensor/scalar ratio of $10^{-2}$. We here report the status of the STRIP pre-commissioning phase and the progress in the characterization of the key subsystems of the SWIPE payload (namely the cryogenic polarization modulation unit and the multi-moded TES pixels) prior to receiver integration.
[2]  oai:arXiv.org:2001.10272  [pdf] - 2065386
QUBIC: the Q & U Bolometric Interferometer for Cosmology
Battistelli, E. S.; Ade, P.; Alberro, J. G.; Almela, A.; Amico, G.; Arnaldi, L. H.; Auguste, D.; Aumont, J.; Azzoni, S.; Banfi, S.; Battaglia, P.; Baù, A.; Bèlier, B.; Bennett, D.; Bergè, L.; Bernard, J. -Ph.; Bersanelli, M.; Bigot-Sazy, M. -A.; Bleurvacq, N.; Bonaparte, J.; Bonis, J.; Bottani, A.; Bunn, E.; Burke, D.; Buzi, D.; Buzzelli, A.; Cavaliere, F.; Chanial, P.; Chapron, C.; Charlassier, R.; Columbro, F.; Coppi, G.; Coppolecchia, A.; D'Alessandro, G.; de Bernardis, P.; De Gasperis, G.; De Leo, M.; De Petris, M.; Dheilly, S.; Di Donato, A.; Dumoulin, L.; Etchegoyen, A.; Fasciszewski, A.; Ferreyro, L. P.; Fracchia, D.; Franceschet, C.; Lerena, M. M. Gamboa; Ganga, K.; Garcìa, B.; Redondo, M. E. Garcìa; Gaspard, M.; Gault, A.; Gayer, D.; Gervasi, M.; Giard, M.; Gilles, V.; Giraud-Heraud, Y.; Berisso, M. Gòmez; Gonzàlez, M.; Gradziel, M.; Grandsire, L.; Hamilton, J. -Ch.; Harari, D.; Haynes, V.; Henrot-Versillè, S.; Hoang, D. T.; Incardona, F.; Jules, E.; Kaplan, J.; Korotkov, A.; Kristukat, C.; Lamagna, L.; Loucatos, S.; Louis, T.; Luterstein, R.; Maffei, B.; Marnieros, S.; Marty, W.; Masi, S.; Mattei, A.; May, A.; McCulloch, M.; Medina, M. C.; Mele, L.; Melhuish, S.; Mennella, A.; Montier, L.; Mousset, L.; Mundo, L. M.; Murphy, J. A.; Murphy, J. D.; Nati, F.; Olivieri, E.; Oriol, C.; O'Sullivan, C.; Paiella, A.; Pajot, F.; Passerini, A.; Pastoriza, H.; Pelosi, A.; Perbost, C.; Perciballi, M.; Pezzotta, F.; Piacentini, F.; Piat, M.; Piccirillo, L.; Pisano, G.; Platino, M.; Polenta, G.; Prèle, D.; Puddu, R.; Rambaud, D.; Ringegni, P.; Romero, G. E.; Salatino, M.; Salum, J. M.; Schillaci, A.; Scòccola, C.; Scully, S.; Spinelli, S.; Stankowiak, G.; Stolpovskiy, M.; Suarez, F.; Tartari, A.; Thermeau, J. -P.; Timbie, P.; Tomasi, M.; Torchinsky, S.; Tristram, M.; Tucker, C.; Tucker, G.; Vanneste, S.; Viganò, D.; Vittorio, N.; Voisin, F.; Watson, B.; Wicek, F.; Zannoni, M.; Zullo, A.
Comments: Accepted for publication in the Journal of Low Temperature Physics
Submitted: 2020-01-28
The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative experiment designed to measure the polarization of the Cosmic Microwave Background and in particular the signature left therein by the inflationary expansion of the Universe. The expected signal is extremely faint, thus extreme sensitivity and systematic control are necessary in order to attempt this measurement. QUBIC addresses these requirements using an innovative approach combining the sensitivity of Transition Edge Sensor cryogenic bolometers, with the deep control of systematics characteristic of interferometers. This makes QUBIC unique with respect to others classical imagers experiments devoted to the CMB polarization. In this contribution we report a description of the QUBIC instrument including recent achievements and the demonstration of the bolometric interferometry performed in lab. QUBIC will be deployed at the observation site in Alto Chorrillos, in Argentina at the end of 2019.
[3]  oai:arXiv.org:1911.12418  [pdf] - 2011325
QUBIC: using NbSi TESs with a bolometric interferometer to characterize the polarisation of the CMB
Piat, M.; Bélier, B.; Bergé, L.; Bleurvacq, N.; Chapron, C.; Dheilly, S.; Dumoulin, L.; González, M.; Grandsire, L.; Hamilton, J. -Ch.; Henrot-Versillé, S.; Hoang, D. T.; Marnieros, S.; Marty, W.; Montier, L.; Olivieri, E.; Oriol, C.; Perbost, C.; Prêle, D.; Rambaud, D.; Salatino, M.; Stankowiak, G.; Thermeau, J. -P.; Torchinsky, S.; Voisin, F.; Ade, P.; Alberro, J. G.; Almela, A.; Amico, G.; Arnaldi, L. H.; Auguste, D.; Aumont, J.; Azzoni, S.; Banfi, S.; Battaglia, P.; Battistelli, E. S.; Baù, A.; Bennett, D.; Bernard, J. -Ph.; Bersanelli, M.; Bigot-Sazy, M. -A.; Bonaparte, J.; Bonis, J.; Bottani, A.; Bunn, E.; Burke, D.; Buzi, D.; Buzzelli, A.; Cavaliere, F.; Chanial, P.; Charlassier, R.; Columbro, F.; Coppi, G.; Coppolecchia, A.; D'Alessandro, G.; de Bernardis, P.; De Gasperis, G.; De Leo, M.; De Petris, M.; Di Donato, A.; Etchegoyen, A.; Fasciszewski, A.; Ferreyro, L. P.; Fracchia, D.; Franceschet, C.; Lerena, M. M. Gamboa; Ganga, K.; García, B.; Redondo, M. E. García; Gaspard, M.; Gault, A.; Gayer, D.; Gervasi, M.; Giard, M.; Gilles, V.; Giraud-Heraud, Y.; Berisso, M. Gómez; Gradziel, M.; Harari, D.; Haynes, V.; Incardona, F.; Jules, E.; Kaplan, J.; Korotkov, A.; Kristukat, C.; Lamagna, L.; Loucatos, S.; Louis, T.; Luterstein, R.; Maffei, B.; Masi, S.; Mattei, A.; May, A.; McCulloch, M.; Medina, M. C.; Mele, L.; Melhuish, S.; Mennella, A.; Mousset, L.; Mundo, L. M.; Murphy, J. A.; Murphy, J. D.; Nati, F.; O'Sullivan, C.; Paiella, A.; Pajot, F.; Passerini, A.; Pastoriza, H.; Pelosi, A.; Perciballi, M.; Pezzotta, F.; Piacentini, F.; Piccirillo, L.; Pisano, G.; Platino, M.; Polenta, G.; Puddu, R.; Ringegni, P.; Romero, G. E.; Salum, J. M.; Schillaci, A.; Scóccola, C.; Scully, S.; Spinelli, S.; Stolpovskiy, M.; Suarez, F.; Tartari, A.; Timbie, P.; Tomasi, M.; Tucker, C.; Tucker, G.; Vanneste, S.; Viganò, D.; Vittorio, N.; Watson, B.; Wicek, F.; Zannoni, M.; Zullo, A.
Comments: Conference proceedings submitted to the Journal of Low Temperature Physics for LTD18
Submitted: 2019-11-27, last modified: 2019-12-09
QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international ground-based experiment dedicated in the measurement of the polarized fluctuations of the Cosmic Microwave Background (CMB). It is based on bolometric interferometry, an original detection technique which combine the immunity to systematic effects of an interferometer with the sensitivity of low temperature incoherent detectors. QUBIC will be deployed in Argentina, at the Alto Chorrillos mountain site near San Antonio de los Cobres, in the Salta province. The QUBIC detection chain consists in 2048 NbSi Transition Edge Sensors (TESs) cooled to 350mK.The voltage-biased TESs are read out with Time Domain Multiplexing based on Superconducting QUantum Interference Devices (SQUIDs) at 1 K and a novel SiGe Application-Specific Integrated Circuit (ASIC) at 60 K allowing to reach an unprecedented multiplexing (MUX) factor equal to 128. The QUBIC experiment is currently being characterized in the lab with a reduced number of detectors before upgrading to the full instrument. I will present the last results of this characterization phase with a focus on the detectors and readout system.
[4]  oai:arXiv.org:1812.00785  [pdf] - 1820173
QUBIC: Exploring the primordial Universe with the Q\&U Bolometric Interferometer
Mennella, Aniello; Ade, Peter; Amico, Giorgio; Auguste, Didier; Aumont, Jonathan; Banfi, Stefano; Barbaràn, Gustavo; Battaglia, Paola; Battistelli, Elia; Baù, Alessandro; Bélier, Benoit; Bennett, David G.; Bergé, Laurent; Bernard, Jean Philippe; Bersanelli, Marco; Sazy, Marie Anne Bigot; Bleurvacq, Nathat; Bonaparte, Juan; Bonis, Julien; Bunn, Emory F.; Burke, David; Buzi, Daniele; Buzzelli, Alessandro; Cavaliere, Francesco; Chanial, Pierre; Chapron, Claude; Charlassier, Romain; Columbro, Fabio; Coppi, Gabriele; Coppolecchia, Alessandro; D'Agostino, Rocco; D'Alessandro, Giuseppe; De Bernardis, Paolo; De Gasperis, Giancarlo; De Leo, Michele; De Petris, Marco; Di Donato, Andres; Dumoulin, Louis; Etchegoyen, Alberto; Fasciszewski, Adrián; Franceschet, Cristian; Lerena, Martin Miguel Gamboa; Garcia, Beatriz; Garrido, Xavier; Gaspard, Michel; Gault, Amanda; Gayer, Donnacha; Gervasi, Massimo; Giard, Martin; Héraud, Yannick Giraud; Berisso, Mariano Gómez; González, Manuel; Gradziel, Marcin; Grandsire, Laurent; Guerard, Eric; Hamilton, Jean Christophe; Harari, Diego; Haynes, Vic; Versillé, Sophie Henrot; Hoang, Duc Thuong; Holtzer, Nicolas; Incardona, Federico; Jules, Eric; Kaplan, Jean; Korotkov, Andrei; Kristukat, Christian; Lamagna, Luca; Loucatos, Soutiris; Lowitz, Amy; Lukovic, Vladimir; Thibault, Louis; Luterstein, Raùl Horacio; Maffei, Bruno; Marnieros, Stefanos; Masi, Silvia; Mattei, Angelo; May, Andrew; McCulloch, Mark; Medina, Maria C.; Mele, Lorenzo; Melhuish, Simon J.; Montier, Ludovic; Mousset, Louise; Mundo, Luis Mariano; Murphy, John Anthony; Murphy, James; O'Sullivan, Creidhe; Olivieri, Emiliano; Paiella, Alessandro; Pajot, Francois; Passerini, Andrea; Pastoriza, Hernan; Pelosi, Alessandro; Perbost, Camille; Perciballi, Maurizio; Pezzotta, Federico; Piacentini, Francesco; Piat, Michel; Piccirillo, Lucio; Pisano, Giampaolo; Polenta, Gianluca; Prêle, Damien; Puddu, Roberto; Rambaud, Damien; Ringegni, Pablo; Romero, Gustavo E.; Salatino, Maria; Schillaci, Alessandro; Scóccola, Claudia G.; Scully, Stephen P.; Spinelli, Sebastiano; Stolpovskiy, Michail; Suarez, Federico; Stankowiak, Guillaume; Tartari, Andrea; Thermeau, Jean Pierre; Timbie, Peter; Tomasi, Maurizio; Torchinsky, Steve A.; Tristram, Mathieu; Tucker, Gregory S.; Tucker, Carole E.; Vanneste, Sylvain; Viganò, Daniele; Vittorio, Nicola; Voisin, Fabrice; Watson, Robert; Wicek, Francois; Zannoni, Mario; Zullo, Antonio
Comments: Proceedings of the 2018 ICNFP conference, Crete. Published by Universe arXiv admin note: text overlap with arXiv:1801.03730
Submitted: 2018-11-30, last modified: 2019-01-23
In this paper we describe QUBIC, an experiment that will observe the polarized microwave sky with a novel approach, which combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. QUBIC unique features are the so-called "self-calibration", a technique that allows us to clean the measured data from instrumental effects, and its spectral imaging power, i.e. the ability to separate the signal in various sub-bands within each frequency band. QUBIC will observe the sky in two main frequency bands: 150 GHz and 220 GHz. A technological demonstrator is currently under testing and will be deployed in Argentina during 2019, while the final instrument is expected to be installed during 2020.
[5]  oai:arXiv.org:1812.03687  [pdf] - 1795038
The STRIP instrument of the Large Scale Polarization Explorer: microwave eyes to map the Galactic polarized foregrounds
Comments: 17 pages, 15 figures, proceedings of the SPIE Astronomical Telescopes + Instrumentation conference "Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy IX", on June 15th, 2018, Austin (TX)
Submitted: 2018-12-10
In this paper we discuss the latest developments of the STRIP instrument of the "Large Scale Polarization Explorer" (LSPE) experiment. LSPE is a novel project that combines ground-based (STRIP) and balloon-borne (SWIPE) polarization measurements of the microwave sky on large angular scales to attempt a detection of the "B-modes" of the Cosmic Microwave Background polarization. STRIP will observe approximately 25% of the Northern sky from the "Observatorio del Teide" in Tenerife, using an array of forty-nine coherent polarimeters at 43 GHz, coupled to a 1.5 m fully rotating crossed-Dragone telescope. A second frequency channel with six-elements at 95 GHz will be exploited as an atmospheric monitor. At present, most of the hardware of the STRIP instrument has been developed and tested at sub-system level. System-level characterization, starting in July 2018, will lead STRIP to be shipped and installed at the observation site within the end of the year. The on-site verification and calibration of the whole instrument will prepare STRIP for a 2-years campaign for the observation of the CMB polarization.
[6]  oai:arXiv.org:1801.03730  [pdf] - 1616675
QUBIC - The Q&U Bolometric Interferometer for Cosmology - A novel way to look at the polarized Cosmic Microwave Background
Comments: Presented at the EPS Conference on High Energy Physics, Venice (Italy), 5-12 July 2017 Accepted for publication in conference proceedings
Submitted: 2018-01-11
In this paper we describe QUBIC, an experiment that takes up the challenge posed by the detection of primordial gravitational waves with a novel approach, that combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. The so-called "self-calibration" is a technique deeply rooted in the interferometric nature of the instrument and allows us to clean the measured data from instrumental effects. The first module of QUBIC is a dual band instrument (150 GHz and 220 GHz) that will be deployed in Argentina during the Fall 2018.
[7]  oai:arXiv.org:1609.04372  [pdf] - 1576378
QUBIC Technical Design Report
Comments: 139 pages ; high resolution version can be found on the qubic website (http://qubic.in2p3.fr/QUBIC/Home.html) minor changes : update author list & affiliations ; correct title
Submitted: 2016-09-14, last modified: 2017-05-11
QUBIC is an instrument aiming at measuring the B mode polarisation anisotropies at medium scales angular scales (30-200 multipoles). The search for the primordial CMB B-mode polarization signal is challenging, because of many difficulties: smallness of the expected signal, instrumental systematics that could possibly induce polarization leakage from the large E signal into B, brighter than anticipated polarized foregrounds (dust) reducing to zero the initial hope of finding sky regions clean enough to have a direct primordial B-modes observation. The QUBIC instrument is designed to address all aspects of this challenge with a novel kind of instrument, a Bolometric Interferometer, combining the background-limited sensitivity of Transition-Edge-Sensors and the control of systematics allowed by the observation of interference fringe patterns, while operating at two frequencies to disentangle polarized foregrounds from primordial B mode polarization. Its characteristics are described in details in this Technological Design Report.
[8]  oai:arXiv.org:1208.0164  [pdf] - 1150428
A coherent polarimeter array for the Large Scale Polarization Explorer balloon experiment
Comments: In press on the Proceedings of the SPIE Conference Astronomical Telescopes + instrumentation 2012, Amsterdam, paper 8446-279
Submitted: 2012-08-01
We discuss the design and expected performance of STRIP (STRatospheric Italian Polarimeter), an array of coherent receivers designed to fly on board the LSPE (Large Scale Polarization Explorer) balloon experiment. The STRIP focal plane array comprises 49 elements in Q band and 7 elements in W-band using cryogenic HEMT low noise amplifiers and high performance waveguide components. In operation, the array will be cooled to 20 K and placed in the focal plane of a $\sim 0.6$ meter telescope providing an angular resolution of $\sim1.5$ degrees. The LSPE experiment aims at large scale, high sensitivity measurements of CMB polarization, with multi-frequency deep measurements to optimize component separation. The STRIP Q-band channel is crucial to accurately measure and remove the synchrotron polarized component, while the W-band channel, together with a bolometric channel at the same frequency, provides a crucial cross-check for systematic effects.
[9]  oai:arXiv.org:1208.0281  [pdf] - 544717
The Large-Scale Polarization Explorer (LSPE)
Comments: In press. Copyright 2012 Society of Photo-Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited
Submitted: 2012-08-01
The LSPE is a balloon-borne mission aimed at measuring the polarization of the Cosmic Microwave Background (CMB) at large angular scales, and in particular to constrain the curl component of CMB polarization (B-modes) produced by tensor perturbations generated during cosmic inflation, in the very early universe. Its primary target is to improve the limit on the ratio of tensor to scalar perturbations amplitudes down to r = 0.03, at 99.7% confidence. A second target is to produce wide maps of foreground polarization generated in our Galaxy by synchrotron emission and interstellar dust emission. These will be important to map Galactic magnetic fields and to study the properties of ionized gas and of diffuse interstellar dust in our Galaxy. The mission is optimized for large angular scales, with coarse angular resolution (around 1.5 degrees FWHM), and wide sky coverage (25% of the sky). The payload will fly in a circumpolar long duration balloon mission during the polar night. Using the Earth as a giant solar shield, the instrument will spin in azimuth, observing a large fraction of the northern sky. The payload will host two instruments. An array of coherent polarimeters using cryogenic HEMT amplifiers will survey the sky at 43 and 90 GHz. An array of bolometric polarimeters, using large throughput multi-mode bolometers and rotating Half Wave Plates (HWP), will survey the same sky region in three bands at 95, 145 and 245 GHz. The wide frequency coverage will allow optimal control of the polarized foregrounds, with comparable angular resolution at all frequencies.
[10]  oai:arXiv.org:1203.5615  [pdf] - 1117549
Intensity and polarization of the atmospheric emission at millimetric wavelengths at Dome Concordia
Comments: MNRAS accepted for publication. Refined analysis
Submitted: 2012-03-26, last modified: 2012-04-20
Atmospheric emission is a dominant source of disturbance in ground-based astronomy at mm wavelengths. The Antarctic plateau is recognized to be an ideal site for mm and sub-mm observations, and the French/Italian base of Dome C is among the best sites on Earth for these observations. In this paper we present measurements, performed using the BRAIN-pathfinder experiment, at Dome C of the atmospheric emission in intensity and polarization at 150GHz, one of the best observational frequencies for CMB observations when considering cosmic signal intensity, atmospheric transmission, detectors sensitivity, and foreground removal. Careful characterization of the air-mass synchronous emission has been performed, acquiring more that 380 elevation scans (i.e. "skydip") during the third BRAIN-pathfinder summer campaign in December 2009/January 2010. The extremely high transparency of the Antarctic atmosphere over Dome Concordia is proven by the very low measured optical depth: <tau_I>=0.050 \pm 0.003 \pm 0.011 where the first error is statistical and the second is systematic error. Mid term stability, over the summer campaign, of the atmosphere emission has also been studied. Adapting the radiative transfer atmosphere emission model "am" to the particular conditions found at Dome C, we also infer the level of the PWV content of the atmosphere, notoriously the main source of disturbance in millimetric astronomy (<PWV>=0.77 +/- 0.06 + 0.15 - 0.12 mm). Upper limits on the air-mass correlated polarized signal are also placed for the first time. The degree of circular polarization of atmospheric emission is found to be lower than 0.2% (95%CL), while the degree of linear polarization is found to be lower than 0.1% (95%CL). These limits include signal-correlated instrumental spurious polarization.
[11]  oai:arXiv.org:1010.0645  [pdf] - 1041046
QUBIC: The QU Bolometric Interferometer for Cosmology
Comments: 12 pages, 10 figures, submitted to Astronomy and Astrophysics
Submitted: 2010-10-04
One of the major challenges of modern cosmology is the detection of B-mode polarization anisotropies in the CMB. These originate from tensor fluctuations of the metric produced during the inflationary phase. Their detection would therefore constitute a major step towards understanding the primordial Universe. The expected level of these anisotropies is however so small that it requires a new generation of instruments with high sensitivity and extremely good control of systematic effects. We propose the QUBIC instrument based on the novel concept of bolometric interferometry, bringing together the sensitivity advantages of bolometric detectors with the systematics effects advantages of interferometry. Methods: The instrument will directly observe the sky through an array of entry horns whose signals will be combined together using an optical combiner. The whole set-up is located inside a cryostat. Polarization modulation will be achieved using a rotating half-wave plate and interference fringes will be imaged on two focal planes (separated by a polarizing grid) tiled with bolometers. We show that QUBIC can be considered as a synthetic imager, exactly similar to a usual imager but with a synthesized beam formed by the array of entry horns. Scanning the sky provides an additional modulation of the signal and improve the sky coverage shape. The usual techniques of map-making and power spectrum estimation can then be applied. We show that the sensitivity of such an instrument is comparable with that of an imager with the same number of horns. We anticipate a low level of beam-related systematics thanks to the fact that the synthesized beam is determined by the location of the primary horns. Other systematics should be under good control thanks to an autocalibration technique, specific to our concept, that will permit the accurate determination of most of the systematics parameters.