Normalized to: Athiray, P.
[1]
oai:arXiv.org:2002.04200 [pdf] - 2061733
FOXSI-2 Solar Microflares I : Multi-instrument Differential Emission
Measure Analysis and Thermal Energies
Athiray, P. S.;
Vievering, Juliana;
Glesener, Lindsay;
Ishikawa, Shin-nosuke;
Narukage, Noriyuki;
Buitrago-Casas, Juan Camilo;
Musset, Sophie;
Inglis, Andrew;
Christe, Steven;
Krucker, Sam;
Ryan, Daniel
Submitted: 2020-02-10
In this paper we present the differential emission measures (DEMs) of two
sub-A class microflares observed in hard X-rays (HXRs) by the FOXSI-2 sounding
rocket experiment, on 2014 December 11. The second FOXSI (Focusing Optics X-ray
Solar Imager) flight was coordinated with instruments Hinode/XRT and SDO/AIA,
which provided observations in soft X-rays (SXR) and Extreme Ultraviolet (EUV).
This unique dataset offers an unprecedented temperature coverage useful for
characterizing the plasma temperature distribution of microflares. By combining
data from FOXSI-2, XRT, and AIA, we determined a well-constrained DEM for the
microflares. The resulting DEMs peak around 3MK and extend beyond 10MK. The
emission measures determined from FOXSI-2 were lower than 10 26cm-5 for
temperatures higher than 5MK; faint emission in this range is best measured in
HXRs. The coordinated FOXSI-2 observations produce one of the few definitive
measurements of the distribution and the amount of plasma above 5MK in
microflares. We utilize the multi-thermal DEMs to calculate the amount of
thermal energy released during both the microflares as ~ 5.0 x 10 28 ergs for
Microflare 1 and ~ 1.6 x 10 28 ergs for Microflare 2. We also show the
multi-thermal DEMs provide a more comprehensive thermal energy estimates than
isothermal approximation, which systematically underestimates the amount of
thermal energy released.
[2]
oai:arXiv.org:1909.02541 [pdf] - 2047563
Solar Active Region Heating Diagnostics from High Temperature Emission
using the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS)
Athiray, P. S.;
Winebarger, Amy R.;
Barnes, Will T.;
Bradshaw, Stephen J.;
Savage, Sabrina;
Warren, Harry P.;
Kobayashi, Ken;
Champey, Patrick;
Golub, Leon;
Glesener, Lindsay
Submitted: 2019-09-05
The relative amount of high temperature plasma has been found to be a useful
diagnostic to determine the frequency of coronal heating on sub-resolution
structures. When the loops are infrequently heated, a broad emission measure
(EM) over a wider range of temperatures is expected. A narrower EM is expected
for high frequency heating where the loops are closer to equilibrium. The soft
X-ray spectrum contains many spectral lines that provide high temperature
diagnostics, including lines from Fe XVII-XIX. This region of the solar
spectrum will be observed by the Marshall Grazing Incidence Spectrometer
(MaGIXS) in 2020. In this paper, we derive the expected spectral lines
intensity in MaGIXS to varying amounts of high temperature plasma to
demonstrate that a simple line ratio of these provides a powerful diagnostic to
determine the heating frequency. Similarly, we examine ratios of AIA channel
intensities, filter ratios from a XRT, and energy bands from the FOXSI sounding
rocket to determine their sensitivity to this parameter. We find that both
FOXSI and MaGIXS provide good diagnostic capability for high-temperature
plasma. We then compare the predicted line ratios to the output of a numerical
model and confirm the MaGIXS ratios provide an excellent diagnostic for heating
frequency.
[3]
oai:arXiv.org:1509.09046 [pdf] - 1286168
Simulating charge transport to understand the spectral response of Swept
Charge Devices
Submitted: 2015-09-30
Swept Charge Devices (SCD) are novel X-ray detectors optimized for improved
spectral performance without any demand for active cooling. The Chandrayaan-1
X-ray Spectrometer (C1XS) experiment onboard the Chandrayaan-1 spacecraft used
an array of SCDs to map the global surface elemental abundances on the Moon
using the X-ray fluorescence (XRF) technique. The successful demonstration of
SCDs in C1XS spurred an enhanced version of the spectrometer on Chandrayaan-2
using the next-generation SCD sensors.
The objective of this paper is to demonstrate validation of a physical model
developed to simulate X-ray photon interaction and charge transportation in a
SCD. The model helps to understand and identify the origin of individual
components that collectively contribute to the energy-dependent spectral
response of the SCD. Furthermore, the model provides completeness to various
calibration tasks, such as generating spectral response matrices (RMFs -
redistribution matrix files), estimating efficiency, optimizing event selection
logic, and maximizing event recovery to improve photon-collection efficiency in
SCDs.
We compare simulation results of the SCD CCD54 with measurements obtained
during the ground calibration of C1XS and clearly demonstrate that our model
reproduces all the major spectral features seen in calibration data. We also
describe our understanding of interactions at different layers of SCD that
contribute to the observed spectrum. Using simulation results, we identify the
origin of different spectral features and quantify their contributions.
[4]
oai:arXiv.org:1310.1336 [pdf] - 728456
Experimental validation of XRF inversion code for Chandrayaan-1
Submitted: 2013-10-04
We have developed an algorithm (x2abundance) to derive the lunar surface
chemistry from X-ray fluorescence (XRF) data for the Chandrayaan-1 X-ray
Spectrometer (C1XS) experiment. The algorithm converts the observed XRF line
fluxes to elemental abundances with uncertainties. We validated the algorithm
in the laboratory using high Z elements (20 < Z < 30) published in Athiray et
al. (2013). In this paper, we complete the exercise of validation using samples
containing low Z elements, which are also analogous to the lunar surface
composition (ie., contains major elements between 11 < Z < 30). The paper
summarizes results from XRF experiments performed on Lunar simulant (JSC-1A)
and anorthosite using a synchrotron beam excitation. We also discuss results
from the validation of x2abundance using Monte Carlo simulation (GEANT4 XRF
simulation).
[5]
oai:arXiv.org:1305.6218 [pdf] - 1171607
Mapping lunar surface chemistry: new prospects with the Chandrayaan-2
Large Area Soft x-ray Spectrometer (CLASS)
Submitted: 2013-05-27
Surface chemistry of airless bodies in the solar system can be derived from
remote x-ray spectral measurements from an orbiting spacecraft. X- rays from
planetary surfaces are excited primarily by solar x-rays. Several experiments
in the past have used this technique of x-ray fluorescence for deriving
abundances of the major rock forming elements. The Chandrayaan- 2 orbiter
carries an x-ray fluorescence experiment named CLASS that is designed based on
results from its predecessor C1XS flown on Chandrayaan-1. We discuss the new
aspects of lunar science that can be potentially achieved with CLASS.
[6]
oai:arXiv.org:1210.7312 [pdf] - 583033
Modeling charge transport in Swept Charge Devices for X-ray spectroscopy
Submitted: 2012-10-27, last modified: 2012-10-30
We present the formulation of an analytical model which simulates charge
transport in Swept Charge Devices (SCDs) to understand the nature of the
spectral redistribution function (SRF). We attempt to construct the
energy-dependent and position dependent SRF by modeling the photon interaction,
charge cloud generation and various loss mechanisms viz., recombination,
partial charge collection and split events. The model will help in optimizing
event selection, maximize event recovery and improve spectral modeling for
Chandrayaan-2 (slated for launch in 2014). A proto-type physical model is
developed and the algorithm along with its results are discussed in this paper.