Normalized to: Askin, A.
[1]
oai:arXiv.org:1101.3866 [pdf] - 956174
Study of the electromagnetic background in the XENON100 experiment
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. -L.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-01-20, last modified: 2013-02-21
The XENON100 experiment, located at the Laboratori Nazionali del Gran Sasso
(LNGS), aims to directly detect dark matter in the form of Weakly Interacting
Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. We
present a comprehensive study of the predicted electronic recoil background
coming from radioactive decays inside the detector and shield materials, and
intrinsic contamination. Based on GEANT4 Monte Carlo simulations using a
detailed geometry together with the measured radioactivity of all detector
components, we predict an electronic recoil background in the WIMP-search
energy range (0-100 keV) in the 30 kg fiducial mass of less than 10e-2
events/(kg-day-keV), consistent with the experiment's design goal. The
predicted background spectrum is in very good agreement with the data taken
during the commissioning of the detector, in Fall 2009.
[2]
oai:arXiv.org:1107.2155 [pdf] - 474250
The XENON100 Dark Matter Experiment
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Brown, E.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. L.;
Kish, A.;
Lam, C. W.;
Lang, R. F.;
Lim, K. E.;
Lopes, J. A. M.;
Undagoitia, T. Marrodan;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Teymourian, A.;
Tziaferi, E.;
Wang, H.;
Yamashita, M.
Submitted: 2011-07-11, last modified: 2012-02-08
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time
projection chamber (TPC) to search for Xe nuclear recoils resulting from the
scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this
paper we present a detailed description of the detector design and present
performance results, as established during the commissioning phase and during
the first science runs.
The active target of XENON100 contains 62 kg of LXe, surrounded by an LXe
veto of 99 kg, both instrumented with photomultiplier tubes (PMTs) operating
inside the liquid or in Xe gas. The LXe target and veto are contained in a
low-radioactivity stainless steel vessel, embedded in a passive radiation
shield. The experiment is installed underground at the Laboratori Nazionali del
Gran Sasso (LNGS), Italy and has recently published results from a 100
live-days dark matter search. The ultimate design goal of XENON100 is to
achieve a spin-independent WIMP-nucleon scattering cross section sensitivity of
\sigma = 2x10^-45 cm^2 for a 100 GeV/c^2 WIMP.
[3]
oai:arXiv.org:1103.2125 [pdf] - 1052646
Gator: a low-background counting facility at the Gran Sasso Underground
Laboratory
Baudis, L.;
Ferella, A. D.;
Askin, A.;
Angle, J.;
Aprile, E.;
Bruch, T.;
Kish, A.;
Laubenstein, M.;
Manalaysay, A.;
Undagoitia, T. Marrodan;
Schumann, M.
Submitted: 2011-03-10, last modified: 2012-01-10
A low-background germanium spectrometer has been installed and is being
operated in an ultra-low background shield (the Gator facility) at the Gran
Sasso underground laboratory in Italy (LNGS). With an integrated rate of ~0.16
events/min in the energy range between 100-2700 keV, the background is
comparable to those of the world's most sensitive germanium detectors. After a
detailed description of the facility, its background sources as well as the
calibration and efficiency measurements are introduced. Two independent
analysis methods are described and compared using examples from selected sample
measurements. The Gator facility is used to screen materials for XENON, GERDA,
and in the context of next-generation astroparticle physics facilities such as
DARWIN.
[4]
oai:arXiv.org:1104.3121 [pdf] - 418418
Implications on Inelastic Dark Matter from 100 Live Days of XENON100
Data
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Bruch, T.;
Bruno, G.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Gao, F.;
Giboni, K. -L.;
Gross, E.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodán;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schumann, M.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-04-15, last modified: 2011-09-09
The XENON100 experiment has recently completed a dark matter run with 100.9
live-days of data, taken from January to June 2010. Events in a 48kg fiducial
volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A
total of three events have been found in the predefined signal region,
compatible with the background prediction of (1.8 \pm 0.6) events. Based on
this analysis we present limits on the WIMP-nucleon cross section for inelastic
dark matter. With the present data we are able to rule out the explanation for
the observed DAMA/LIBRA modulation as being due to inelastic dark matter
scattering off iodine at a 90% confidence level.
[5]
oai:arXiv.org:1104.2549 [pdf] - 966664
Dark Matter Results from 100 Live Days of XENON100 Data
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Bruch, T.;
Bruno, G.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Gao, F.;
Giboni, K. -L.;
Gross, E.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schumann, M.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-04-13, last modified: 2011-09-07
We present results from the direct search for dark matter with the XENON100
detector, installed underground at the Laboratori Nazionali del Gran Sasso of
INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg
liquid xenon target. Interaction vertex reconstruction in three dimensions with
millimeter precision allows to select only the innermost 48 kg as ultra-low
background fiducial target. In 100.9 live days of data, acquired between
January and June 2010, no evidence for dark matter is found. Three candidate
events were observed in a pre-defined signal region with an expected background
of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter
interactions today, excluding spin-independent elastic WIMP-nucleon scattering
cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90%
confidence level.
[6]
oai:arXiv.org:1103.0303 [pdf] - 427646
Likelihood Approach to the First Dark Matter Results from XENON100
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Bruch, T.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. -L.;
Gross, E.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Lim, K. E.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Undagoitia, T. Marrodán;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-03-01, last modified: 2011-09-07
Many experiments that aim at the direct detection of Dark Matter are able to
distinguish a dominant background from the expected feeble signals, based on
some measured discrimination parameter. We develop a statistical model for such
experiments using the Profile Likelihood ratio as a test statistic in a
frequentist approach. We take data from calibrations as control measurements
for signal and background, and the method allows the inclusion of data from
Monte Carlo simulations. Systematic detector uncertainties, such as
uncertainties in the energy scale, as well as astrophysical uncertainties, are
included in the model. The statistical model can be used to either set an
exclusion limit or to make a discovery claim, and the results are derived with
a proper treatment of statistical and systematic uncertainties. We apply the
model to the first data release of the XENON100 experiment, which allows to
extract additional information from the data, and place stronger limits on the
spin-independent elastic WIMP-nucleon scattering cross-section. In particular,
we derive a single limit, including all relevant systematic uncertainties, with
a minimum of 2.4x10^-44 cm^2 for WIMPs with a mass of 50 GeV/c^2.
[7]
oai:arXiv.org:1005.0380 [pdf] - 325339
First Dark Matter Results from the XENON100 Experiment
The XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Brown, E.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D. B.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. -L.;
Hugenberg, K.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Lim, K. E.;
Lopes, J. A. M.;
Undagoitia, T. Marrodán;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Wang, H.;
Weinheimer, C.
Submitted: 2010-05-03, last modified: 2011-03-01
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran
Sasso in Italy, is designed to search for dark matter WIMPs scattering off 62
kg of liquid xenon in an ultra-low background dual-phase time projection
chamber. In this letter, we present first dark matter results from the analysis
of 11.17 live days of non-blind data, acquired in October and November 2009. In
the selected fiducial target of 40 kg, and within the pre-defined signal
region, we observe no events and hence exclude spin-independent WIMP-nucleon
elastic scattering cross-sections above 3.4 x 10^-44 cm^2 for 55 GeV/c^2 WIMPs
at 90% confidence level. Below 20 GeV/c^2, this result constrains the
interpretation of the CoGeNT and DAMA signals as being due to spin-independent,
elastic, light mass WIMP interactions.
[8]
oai:arXiv.org:0908.0616 [pdf] - 205480
Spatially uniform calibration of a liquid xenon detector at low energies
using 83m-Kr
Manalaysay, A.;
Undagoitia, T. Marrodan;
Askin, A.;
Baudis, L.;
Behrens, A.;
Ferella, A. D.;
Kish, A.;
Lebeda, O.;
Santorelli, R.;
Venos, D.;
Vollhardt, A.
Submitted: 2009-08-05, last modified: 2010-05-16
A difficult task with many particle detectors focusing on interactions below
~100 keV is to perform a calibration in the appropriate energy range that
adequately probes all regions of the detector. Because detector response can
vary greatly in various locations within the device, a spatially uniform
calibration is important. We present a new method for calibration of liquid
xenon (LXe) detectors, using the short-lived 83m-Kr. This source has
transitions at 9.4 and 32.1 keV, and as a noble gas like Xe, it disperses
uniformly in all regions of the detector. Even for low source activities, the
existence of the two transitions provides a method of identifying the decays
that is free of background. We find that at decreasing energies, the LXe light
yield increases, while the amount of electric field quenching is diminished.
Additionally, we show that if any long-lived radioactive backgrounds are
introduced by this method, they will present less than 67E-6 events/kg/day in
the next generation of LXe dark matter direct detection searches