Normalized to: Asaoka, Y.
[1]
oai:arXiv.org:2004.04304 [pdf] - 2077341
Cosmic-Ray Signatures of Dark Matter from a Flavor Dependent Gauge
Symmetry Model with Neutrino Mass Mechanism
Submitted: 2020-04-08
We propose an extension to the Standard Model accommodating two families of
Dirac neutral fermions and Majorana fermions under additional ${U(1)_{e-\mu}
\times Z_3\times Z_2}$ symmetries where ${U(1)_{e-\mu}}$ is a flavor dependent
gauge symmetry related to the first and second family of the lepton sector,
which features a two-loop induced neutrino mass model. The two families are
favored by minimally reproducing the current neutrino oscillation data and two
mass difference squares and canceling the gauge anomalies at the same time. As
a result, we have a prediction for neutrino masses. The lightest Dirac neutral
fermion is a dark matter candidate with tree-level interaction restricted to
electron, muon and neutrinos, which makes it difficult to detect in direct dark
matter search as well as indirect search focusing on the ${\tau}$-channel, such
as through ${\gamma}$-rays. It may however be probed by search for dark matter
signatures in electron and positron cosmic rays, and allows interpretation of a
structure appearing in the CALET electron+positron spectrum around 350-400 GeV
as its signature, with a boost factor $\approx$40 Breit-Wigner enhancement of
the annihilation cross section.
[2]
oai:arXiv.org:1905.04229 [pdf] - 1881109
Direct Measurement of the Cosmic-Ray Proton Spectrum from 50 GeV to 10
TeV with the Calorimetric Electron Telescope on the International Space
Station
Adriani, O.;
Akaike, Y.;
Asano, K.;
Asaoka, Y.;
Bagliesi, M. G.;
Berti, E.;
Bigongiari, G.;
Binns, W. R.;
Bonechi, S.;
Bongi, M.;
Bruno, A.;
Buckley, J. H.;
Cannady, N.;
Castellini, G.;
Checchia, C.;
Cherry, M. L.;
Collazuol, G.;
Di Felice, V.;
Ebisawa, K.;
Fuke, H.;
Guzik, T. G.;
Hams, T.;
Hasebe, N.;
Hibino, K.;
Ichimura, M.;
Ioka, K.;
Ishizaki, W.;
Israel, M. H.;
Kasahara, K.;
Kataoka, J.;
Kataoka, R.;
Katayose, Y.;
Kato, C.;
Kawanaka, N.;
Kawakubo, Y.;
Kohri, K.;
Krawczynski, H. S.;
Krizmanic, J. F.;
Lomtadze, T.;
Maestro, P.;
Marrocchesi, P. S.;
Messineo, A. M.;
Mitchell, J. W.;
Miyake, S.;
Moiseev, A. A.;
Mori, K.;
Mori, M.;
Mori, N.;
Motz, H. M.;
Munakata, K.;
Murakami, H.;
Nakahira, S.;
Nishimura, J.;
de Nolfo, G. A.;
Okuno, S.;
Ormes, J. F.;
Ozawa, S.;
Pacini, L.;
Palma, F.;
Papini, P.;
Penacchioni, A. V.;
Rauch, B. F.;
Ricciarini, S. B.;
Sakai, K.;
Sakamoto, T.;
Sasaki, M.;
Shimizu, Y.;
Shiomi, A.;
Sparvoli, R.;
Spillantini, P.;
Stolzi, F.;
Suh, J. E.;
Sulaj, A.;
Takahashi, I.;
Takayanagi, M.;
Takita, M.;
Tamura, T.;
Terasawa, T.;
Tomida, H.;
Torii, S.;
Tsunesada, Y.;
Uchihori, Y.;
Ueno, S.;
Vannuccini, E.;
Wefel, J. P.;
Yamaoka, K.;
Yanagita, S.;
Yoshida, A.;
Yoshida, K.
Submitted: 2019-05-10
In this paper, we present the analysis and results of a direct measurement of
the cosmic-ray proton spectrum with the CALET instrument onboard the
International Space Station, including the detailed assessment of systematic
uncertainties. The observation period used in this analysis is from October 13,
2015 to August 31, 2018 (1054 days). We have achieved the very wide energy
range necessary to carry out measurements of the spectrum from 50 GeV to 10 TeV
covering, for the first time in space, with a single instrument the whole
energy interval previously investigated in most cases in separate subranges by
magnetic spectrometers (BESS-TeV, PAMELA, and AMS-02) and calorimetric
instruments (ATIC, CREAM, and NUCLEON). The observed spectrum is consistent
with AMS-02 but extends to nearly an order of magnitude higher energy, showing
a very smooth transition of the power-law spectral index from -2.81 +- 0.03
(50--500 GeV) neglecting solar modulation effects (or -2.87 +- 0.06 including
solar modulation effects in the lower energy region) to -2.56 +- 0.04 (1--10
TeV), thereby confirming the existence of spectral hardening and providing
evidence of a deviation from a single power law by more than 3 sigma.
[3]
oai:arXiv.org:1903.07271 [pdf] - 1854168
The CALorimetric Electron Telescope (CALET) on the International Space
Station: Results from the First Two Years On Orbit
Asaoka, Y.;
Adriani, O.;
Akaike, Y.;
Asano, K.;
Bagliesi, M. G.;
Berti, E.;
Bigongiari, G.;
Binns, W. R.;
Bonechi, S.;
Bongi, M.;
Bruno, A.;
Brogi, P.;
Buckley, J. H.;
Cannady, N.;
Castellini, G.;
Checchia, C.;
Cherry, M. L.;
Collazuol, G.;
Felice, V. Di.;
Ebisawa, K.;
Fuke, H.;
Guzik, T. G.;
Hams, T.;
Hasebe, N.;
Hibino, K.;
Ichimura, M.;
Ioka, K.;
Ishizaki, W.;
Israel, M. H.;
Kasahara, K.;
Kataoka, J.;
Kataoka, R.;
Katayose, Y.;
Kato, C.;
Kawanaka, N.;
Kawakubo, Y.;
Kohri, K.;
Krawczynski, H. S.;
Krizmanic, J. F.;
Lomtadze, T.;
Maestro, P.;
Marrocchesi, P. S.;
Messineo, A. M.;
Mitchell, J. W.;
Miyake, S.;
Moiseev, A. A.;
Mori, K.;
Mori, M.;
Mori, N.;
Motz, H. M.;
Munakata, K.;
Murakami, H.;
Nakahira, S.;
Nishimura, J.;
Nolfo, G. A. De.;
Okuno, S.;
Ormes, J. F.;
Ozawa, S.;
Pacini, L.;
Palma, F.;
Pal'shin, V.;
Papini, P.;
Penacchioni, A. V.;
Rauch, B. F.;
Ricciarini, S. B.;
Sakai, K.;
Sakamoto, T.;
Sasaki, M.;
Shimizu, Y.;
Shiomi, A.;
Sparvoli, R.;
Spillantini, P.;
Stolzi, F.;
Sugita, S.;
Suh, J. E.;
Sulaj, A.;
Takahashi, I.;
Takayanagi, M.;
Takita, M.;
Tamura, T.;
Tateyama, N.;
Terasawa, T.;
Tomida, H.;
Torii, S.;
Tsunesada, Y.;
Uchihori, Y.;
Ueno, S.;
Vannuccini, E.;
Wefel, J. P.;
Yamaoka, K.;
Yanagita, S.;
Yoshida, A.;
Yoshida, K.
Submitted: 2019-03-18
The CALorimetric Electron Telescope (CALET) is a high-energy astroparticle
physics space experiment installed on the International Space Station (ISS),
developed and operated by Japan in collaboration with Italy and the United
States. The CALET mission goals include the investigation of possible nearby
sources of high-energy electrons, of the details of galactic particle
acceleration and propagation, and of potential signatures of dark matter. CALET
measures the cosmic-ray electron + positron flux up to 20 TeV, gamma-rays up to
10 TeV, and nuclei with Z=1 to 40 up to 1,000 TeV for the more abundant
elements during a long-term observation aboard the ISS. Starting science
operation in mid-October 2015, CALET performed continuous observation without
major interruption with close to 20 million triggered events over 10 GeV per
month. Based on the data taken during the first two-years, we present an
overview of CALET observations: uses w/o major interruption 1) Electron +
positron energy spectrum, 2) Nuclei analysis, 3) Gamma-ray observation
including a characterization of on-orbit performance. Results of the
electromagnetic counterpart search for LIGO/Virgo gravitational wave events are
discussed as well.
[4]
oai:arXiv.org:1712.06265 [pdf] - 1770528
An Interpretation of the Cosmic Ray $e^+\, +\, e^-$ Spectrum from 10 GeV
to 3 TeV Measured by CALET on the ISS
Submitted: 2017-12-18, last modified: 2018-10-22
A combined interpretation of the CALET $e^+\, +\, e^-$ spectrum up to 3 TeV
and the AMS-02 positron spectrum up to 500 GeV was performed and the results
are discussed. To parametrize the background electron flux, we assume a
smoothly broken power-law spectrum with an exponential cut-off for electrons
and fit this parametrization to the measurements, with either a pulsar or
3-body decay of fermionic Dark Matter as the extra electron-positron pair
source responsible for the positron excess. We found that depending on the
parameters for the background, both Dark Matter decay and the pulsar model can
explain the combined measurements. While the Dark Matter decay scenario is
constrained by the Fermi-LAT $\gamma$-ray measurement, we show that 3-body
decay of a 800 GeV Dark Matter can be compatible with the $\gamma$-ray flux
measurement. We discuss the capability of CALET to discern decaying Dark Matter
models from a generic pulsar source scenario, based on simulated data for five
years of data-taking.
[5]
oai:arXiv.org:1807.01435 [pdf] - 1740024
Search for GeV Gamma-ray Counterparts of Gravitational Wave Events by
CALET
Adriani, O.;
Akaike, Y.;
Asano, K.;
Asaoka, Y.;
Bagliesi, M. G.;
Berti, E.;
Bigongiari, G.;
Binns, W. R.;
Bonechi, S.;
Bongi, M.;
Brogi, P.;
Buckley, J. H.;
Cannady, N.;
Castellini, G.;
Checchia, C.;
Cherry, M. L.;
Collazuol, G.;
Di Felice, V.;
Ebisawa, K.;
Fuke, H.;
Guzik, T. G.;
Hams, T.;
Hareyama, M.;
Hasebe, N.;
Hibino, K.;
Ichimura, M.;
Ioka, K.;
Ishizaki, W.;
Israel, M. H.;
Kasahara, K.;
Kataoka, J.;
Kataoka, R.;
Katayose, Y.;
Kato, C.;
Kawanaka, N.;
Kawakubo, Y.;
Krawczynski, H. S.;
Krizmanic, J. F.;
Kohri, K.;
Lomtadze, T.;
Maestro, P.;
Marrocchesi, P. S.;
Messineo, A. M.;
Mitchell, J. W.;
Miyake, S.;
Moiseev, A. A.;
Mori, K.;
Mori, M.;
Mori, N.;
Motz, H. M.;
Munakata, K.;
Murakami, H.;
Nakahira, S.;
Nishimura, J.;
de Nolfo, G. A.;
Okuno, S.;
Ormes, J. F.;
Ozawa, S.;
Pacini, L.;
Palma, F.;
Papini, P.;
Penacchioni, A. V.;
Rauch, B. F.;
Ricciarini, S. B.;
Sakai, K.;
Sakamoto, T.;
Sasaki, M.;
Shimizu, Y.;
Shiomi, A.;
Sparvoli, R.;
Spillantini, P.;
Stolzi, F.;
Suh, J. E.;
Sulaj, A.;
Takahashi, I.;
Takayanagi, M.;
Takita, M.;
Tamura, T.;
Tateyama, N.;
Terasawa, T.;
Tomida, H.;
Torii, S.;
Tsunesada, Y.;
Uchihori, Y.;
Ueno, S.;
Vannuccini, E.;
Wefel, J. P.;
Yamaoka, K.;
Yanagita, S.;
Yoshida, A.;
Yoshida, K.
Submitted: 2018-07-03
We present results on searches for gamma-ray counterparts of the LIGO/Virgo
gravitational-wave events using CALorimetric Electron Telescope ({\sl CALET})
observations. The main instrument of {\sl CALET}, CALorimeter (CAL), observes
gamma-rays from $\sim1$ GeV up to 10 TeV with a field of view of nearly 2 sr.
In addition, the {\sl CALET} gamma-ray burst monitor (CGBM) views $\sim$3 sr
and $\sim2\pi$ sr of the sky in the 7 keV -- 1 MeV and the 40 keV -- 20 MeV
bands, respectively, by using two different crystal scintillators. The {\sl
CALET} observations on the International Space Station started in October 2015,
and here we report analyses of events associated with the following
gravitational wave events: GW151226, GW170104, GW170608, GW170814 and GW170817.
Although only upper limits on gamma-ray emission are obtained, they correspond
to a luminosity of $10^{49}\sim10^{53}$ erg s$^{-1}$ in the GeV energy band
depending on the distance and the assumed time duration of each event, which is
approximately the order of luminosity of typical short gamma-ray bursts. This
implies there will be a favorable opportunity to detect high-energy gamma-ray
emission in further observations if additional gravitational wave events with
favorable geometry will occur within our field-of-view. We also show the
sensitivity of {\sl CALET} for gamma-ray transient events which is the order of
$10^{-7}$~erg\,cm$^{-2}$\,s$^{-1}$ for an observation of 100~s duration.
[6]
oai:arXiv.org:1806.09728 [pdf] - 1705412
Extended Measurement of the Cosmic-Ray Electron and Positron Spectrum
from 11 GeV to 4.8 TeV with the Calorimetric Electron Telescope on the
International Space Station
Adriani, O.;
Akaike, Y.;
Asano, K.;
Asaoka, Y.;
Bagliesi, M. G.;
Berti, E.;
Bigongiari, G.;
Binns, W. R.;
Bonechi, S.;
Bongi, M.;
Brogi, P.;
Buckley, J. H.;
Cannady, N.;
Castellini, G.;
Checchia, C.;
Cherry, M. L.;
Collazuol, G.;
Di Felice, V.;
Ebisawa, K.;
Fuke, H.;
Guzik, T. G.;
Hams, T.;
Hareyama, M.;
Hasebe, N.;
Hibino, K.;
Ichimura, M.;
Ioka, K.;
Ishizaki, W.;
Israel, M. H.;
Kasahara, K.;
Kataoka, J.;
Kataoka, R.;
Katayose, Y.;
Kato, C.;
Kawanaka, N.;
Kawakubo, Y.;
Kohri, K.;
Krawczynski, H. S.;
Krizmanic, J. F.;
Lomtadze, T.;
Maestro, P.;
Marrocchesi, P. S.;
Messineo, A. M.;
Mitchell, J. W.;
Miyake, S.;
Moiseev, A. A.;
Mori, K.;
Mori, M.;
Mori, N.;
Motz, H. M.;
Munakata, K.;
Murakami, H.;
Nakahira, S.;
Nishimura, J.;
de Nolfo, G. A.;
Okuno, S.;
Ormes, J. F.;
Ozawa, S.;
Pacini, L.;
Palma, F.;
Papini, P.;
Penacchioni, A. V.;
Rauch, B. F.;
Ricciarini, S. B.;
Sakai, K.;
Sakamoto, T.;
Sasaki, M.;
Shimizu, Y.;
Shiomi, A.;
Sparvoli, R.;
Spillantini, P.;
Stolzi, F.;
Suh, J. E.;
Sulaj, A.;
Takahashi, I.;
Takayanagi, M.;
Takita, M.;
Tamura, T.;
Tateyama, N.;
Terasawa, T.;
Tomida, H.;
Torii, S.;
Tsunesada, Y.;
Uchihori, Y.;
Ueno, S.;
Vannuccini, E.;
Wefel, J. P.;
Yamaoka, K.;
Yanagita, S.;
Yoshida, A.;
Yoshida, K.
Submitted: 2018-06-25
Extended results on the cosmic-ray electron + positron spectrum from 11 GeV
to 4.8 TeV are presented based on observations with the Calorimetric Electron
Telescope (CALET) on the International Space Station utilizing the data up to
November 2017. The analysis uses the full detector acceptance at high energies,
approximately doubling the statistics compared to the previous result. CALET is
an all-calorimetric instrument with a total thickness of 30 $X_0$ at normal
incidence and fine imaging capability, designed to achieve large proton
rejection and excellent energy resolution well into the TeV energy region. The
observed energy spectrum in the region below 1 TeV shows good agreement with
Alpha Magnetic Spectrometer (AMS-02) data. In the energy region below $\sim$300
GeV, CALET's spectral index is found to be consistent with the AMS-02, Fermi
Large Area Telescope (Fermi-LAT) and Dark Matter Particle Explorer (DAMPE),
while from 300 to 600 GeV the spectrum is significantly softer than the spectra
from the latter two experiments. The absolute flux of CALET is consistent with
other experiments at around a few tens of GeV. However, it is lower than those
of DAMPE and Fermi-LAT with the difference increasing up to several hundred
GeV. The observed energy spectrum above $\sim$1 TeV suggests a flux suppression
consistent within the errors with the results of DAMPE, while CALET does not
observe any significant evidence for a narrow spectral feature in the energy
region around 1.4 TeV. Our measured all-electron flux, including statistical
errors and a detailed breakdown of the systematic errors, is tabulated in the
Supplemental Material in order to allow more refined spectral analyses based on
our data.
[7]
oai:arXiv.org:1803.05834 [pdf] - 1650562
On-orbit Operations and Offline Data Processing of CALET onboard the ISS
Asaoka, Y.;
Ozawa, S.;
Torii, S.;
Adriani, O.;
Akaike, Y.;
Asano, K.;
Bagliesi, M. G.;
Bigongiari, G.;
Binns, W. R.;
Bonechi, S.;
Bongi, M.;
Brogi, P.;
Buckley, J. H.;
Cannady, N.;
Castellini, G.;
Checchia, C.;
Cherry, M. L.;
Collazuol, G.;
Di Felice, V.;
Ebisawa, K.;
Fuke, H.;
Guzik, T. G.;
Hams, T.;
Hareyama, M.;
Hasebe, N.;
Hibino, K.;
Ichimura, M.;
Ioka, K.;
Ishizaki, W.;
Israel, M. H.;
Javaid, A.;
Kasahara, K.;
Kataoka, J.;
Kataoka, R.;
Katayose, Y.;
Kato, C.;
Kawanaka, N.;
Kawakubo, Y.;
Kohri, K.;
Krawczynski, H. S.;
Krizmanic, J. F.;
Kuramata, S.;
Lomtadze, T.;
Maestro, P.;
Marrocchesi, P. S.;
Messineo, A. M.;
Mitchell, J. W.;
Miyake, S.;
Mizutani, K.;
Moiseev, A. A.;
Mori, K.;
Mori, M.;
Mori, N.;
Motz, H. M.;
Munakata, K.;
Murakami, H.;
Nakahira, S.;
Nishimura, J.;
de Nolfo, G. A.;
Okuno, S.;
Ormes, J. F.;
Pacini, L.;
Palma, F.;
Papini, P.;
Penacchioni, A. V.;
Rauch, B. F.;
Ricciarini, S. B.;
Sakai, K.;
Sakamoto, T.;
Sasaki, M.;
Shimizu, Y.;
Shiomi, A.;
Sparvoli, R.;
Spillantini, P.;
Stolzi, F.;
Takahashi, I.;
Takayanagi, M.;
Takita, M.;
Tamura, T.;
Tateyama, N.;
Terasawa, T.;
Tomida, H.;
Tsunesada, Y.;
Uchihori, Y.;
Ueno, S.;
Vannuccini, E.;
Wefel, J. P.;
Yamaoka, K.;
Yanagita, S.;
Yoshida, A.;
Yoshida, K.;
Yuda, T.
Submitted: 2018-03-15
The CALorimetric Electron Telescope (CALET), launched for installation on the
International Space Station (ISS) in August, 2015, has been accumulating
scientific data since October, 2015. CALET is intended to perform long-duration
observations of high-energy cosmic rays onboard the ISS. CALET directly
measures the cosmic-ray electron spectrum in the energy range of 1 GeV to 20
TeV with a 2% energy resolution above 30 GeV. In addition, the instrument can
measure the spectrum of gamma rays well into the TeV range, and the spectra of
protons and nuclei up to a PeV.
In order to operate the CALET onboard ISS, JAXA Ground Support Equipment
(JAXA-GSE) and the Waseda CALET Operations Center (WCOC) have been established.
Scientific operations using CALET are planned at WCOC, taking into account
orbital variations of geomagnetic rigidity cutoff. Scheduled command sequences
are used to control the CALET observation modes on orbit. Calibration data
acquisition by, for example, recording pedestal and penetrating particle
events, a low-energy electron trigger mode operating at high geomagnetic
latitude, a low-energy gamma-ray trigger mode operating at low geomagnetic
latitude, and an ultra heavy trigger mode, are scheduled around the ISS orbit
while maintaining maximum exposure to high-energy electrons and other
high-energy shower events by always having the high-energy trigger mode active.
The WCOC also prepares and distributes CALET flight data to collaborators in
Italy and the United States.
As of August 31, 2017, the total observation time is 689 days with a live
time fraction of the total time of approximately 84%. Nearly 450 million events
are collected with a high-energy (E>10 GeV) trigger. By combining all operation
modes with the excellent-quality on-orbit data collected thus far, it is
expected that a five-year observation period will provide a wealth of new and
interesting results.
[8]
oai:arXiv.org:1712.02940 [pdf] - 1648737
Detection of the thermal component in GRB 160107A
Kawakubo, Yuta;
Sakamoto, Takanori;
Nakahira, Satoshi;
Yamaoka, Kazutaka;
Serino, Motoko;
Asaoka, Yoichi;
Cherry, M. L.;
Matsukawa, Shohei;
Mori, Masaki;
Nakagawa, Yujin;
Ozawa, Shunsuke;
Penacchioni, A. V.;
Ricciarini, S. B.;
Tezuka, Akira;
Torii, Shoji;
Yamada, Yusuke;
Yoshida, Atsumasa
Submitted: 2017-12-08
We present the detection of a blackbody component in GRB 160107A emission by
using the combined spectral data of the CALET Gamma-ray Burst Monitor (CGBM)
and the MAXI Gas Slit Camera (GSC). The MAXI/GSC detected the emission $\sim$45
s prior to the main burst episode observed by the CGBM. The MAXI/GSC and the
CGBM spectrum of this prior emission period is well fit by a blackbody with the
temperature of $1.0^{+0.3}_{-0.2}$ keV plus a power-law with the photon index
of $-1.6 \pm 0.3$. We discuss the radius to the photospheric emission and the
main burst emission based on the observational properties. We stress the
importance of the coordinated observations via various instruments collecting
the high quality data over a broad energy coverage in order to understand the
GRB prompt emission mechanism.
[9]
oai:arXiv.org:1712.01757 [pdf] - 1598372
Energy Calibration of CALET Onboard the International Space Station
Asaoka, Y.;
Akaike, Y.;
Komiya, Y.;
Miyata, R.;
Torii, S.;
Adriani, O.;
Asano, K.;
Bagliesi, M. G.;
Bigongiari, G.;
Binns, W. R.;
Bonechi, S.;
Bongi, M.;
Brogi, P.;
Buckley, J. H.;
Cannady, N.;
Castellini, G.;
Checchia, C.;
Cherry, M. L.;
Collazuol, G.;
Di Felice, V.;
Ebisawa, K.;
Fuke, H.;
Guzik, T. G.;
Hams, T.;
Hareyama, M.;
Hasebe, N.;
Hibino, K.;
Ichimura, M.;
Ioka, K.;
Ishizaki, W.;
Israel, M. H.;
Javaid, A.;
Kasahara, K.;
Kataoka, J.;
Kataoka, R.;
Katayose, Y.;
Kato, C.;
Kawanaka, N.;
Kawakubo, Y.;
Kitamura, H.;
Krawczynski, H. S.;
Krizmanic, J. F.;
Kuramata, S.;
Lomtadze, T.;
Maestro, P.;
Marrocchesi, P. S.;
Messineo, A. M.;
Mitchell, J. W.;
Miyake, S.;
Mizutani, K.;
Moiseev, A. A.;
Mori, K.;
Mori, M.;
Mori, N.;
Motz, H. M.;
Munakata, K.;
Murakami, H.;
Nakagawa, Y. E.;
Nakahira, S.;
Nishimura, J.;
Okuno, S.;
Ormes, J. F.;
Ozawa, S.;
Pacini, L.;
Palma, F.;
Papini, P.;
Penacchioni, A. V.;
Rauch, B. F.;
Ricciarini, S.;
Sakai, K.;
Sakamoto, T.;
Sasaki, M.;
Shimizu, Y.;
Shiomi, A.;
Sparvoli, R.;
Spillantini, P.;
Stolzi, F.;
Takahashi, I.;
Takayanagi, M.;
Takita, M.;
Tamura, T.;
Tateyama, N.;
Terasawa, T.;
Tomida, H.;
Tsunesada, Y.;
Uchihori, Y.;
Ueno, S.;
Vannuccini, E.;
Wefel, J. P.;
Yamaoka, K.;
Yanagita, S.;
Yoshida, A.;
Yoshida, K.;
Yuda, T.
Submitted: 2017-12-05
In August 2015, the CALorimetric Electron Telescope (CALET), designed for
long exposure observations of high energy cosmic rays, docked with the
International Space Station (ISS) and shortly thereafter began tocollect data.
CALET will measure the cosmic ray electron spectrum over the energy range of 1
GeV to 20 TeV with a very high resolution of 2% above 100 GeV, based on a
dedicated instrument incorporating an exceptionally thick 30 radiation-length
calorimeter with both total absorption and imaging (TASC and IMC) units. Each
TASC readout channel must be carefully calibrated over the extremely wide
dynamic range of CALET that spans six orders of magnitude in order to obtain a
degree of calibration accuracy matching the resolution of energy measurements.
These calibrations consist of calculating the conversion factors between ADC
units and energy deposits, ensuring linearity over each gain range, and
providing a seamless transition between neighboring gain ranges. This paper
describes these calibration methods in detail, along with the resulting data
and associated accuracies. The results presented in this paper show that a
sufficient accuracy was achieved for the calibrations of each channel in order
to obtain a suitable resolution over the entire dynamic range of the electron
spectrum measurement.
[10]
oai:arXiv.org:1712.01711 [pdf] - 1598369
Energy Spectrum of Cosmic-ray Electron and Positron from 10 GeV to 3 TeV
Observed with the Calorimetric Electron Telescope on the International Space
Station
Adriani, O.;
Akaike, Y.;
Asano, K.;
Asaoka, Y.;
Bagliesi, M. G.;
Bigongiari, G.;
Binns, W. R.;
Bonechi, S.;
Bongi, M.;
Brogi, P.;
Buckley, J. H.;
Cannady, N.;
Castellini, G.;
Checchia, C.;
Cherry, M. L.;
Collazuol, G.;
Di Felice, V.;
Ebisawa, K.;
Fuke, H.;
Guzik, T. G.;
Hams, T.;
Hareyama, M.;
Hasebe, N.;
Hibino, K.;
Ichimura, M.;
Ioka, K.;
Ishizaki, W.;
Israel, M. H.;
Javaid, A.;
Kasahara, K.;
Kataoka, J.;
Kataoka, R.;
Katayose, Y.;
Kato, C.;
Kawanaka, N.;
Kawakubo, Y.;
Krawczynski, H. S.;
Krizmanic, J. F.;
Kuramata, S.;
Lomtadze, T.;
Maestro, P.;
Marrocchesi, P. S.;
Messineo, A. M.;
Mitchell, J. W.;
Miyake, S.;
Mizutani, K.;
Moiseev, A. A.;
Mori, K.;
Mori, M.;
Mori, N.;
Motz, H. M.;
Munakata, K.;
Murakami, H.;
Nakahira, S.;
Nishimura, J.;
de Nolfo, G. A.;
Okuno, S.;
Ormes, J. F.;
Ozawa, S.;
Pacini, L.;
Palma, F.;
Papini, P.;
Penacchioni, A. V.;
Rauch, B. F.;
Ricciarini, S. B.;
Sakai, K.;
Sakamoto, T.;
Sasaki, M.;
Shimizu, Y.;
Shiomi, A.;
Sparvoli, R.;
Spillantini, P.;
Stolzi, F.;
Takahashi, I.;
Takayanagi, M.;
Takita, M.;
Tamura, T.;
Tateyama, N.;
Terasawa, T.;
Tomida, H.;
Torii, S.;
Tsunesada, Y.;
Uchihori, Y.;
Ueno, S.;
Vannuccini, E.;
Wefel, J. P.;
Yamaoka, K.;
Yanagita, S.;
Yoshida, A.;
Yoshida, K.;
Yuda, T.
Submitted: 2017-12-05
First results of a cosmic-ray electron + positron spectrum, from 10 GeV to 3
TeV, is presented based upon observations with the CALET instrument on the ISS
starting in October, 2015. Nearly a half million electron + positron events are
included in the analysis. CALET is an all-calorimetric instrument with total
vertical thickness of 30 $X_0$ and a fine imaging capability designed to
achieve a large proton rejection and excellent energy resolution well into the
TeV energy region. The observed energy spectrum over 30 GeV can be fit with a
single power law with a spectral index of -3.152 $\pm$ 0.016 (stat.+ syst.).
Possible structure observed above 100 GeV requires further investigation with
increased statistics and refined data analysis.
[11]
oai:arXiv.org:1702.02546 [pdf] - 1581431
Decaying Fermionic Dark Matter Search with CALET
Submitted: 2017-02-08, last modified: 2017-05-09
The ISS-based CALET (CALorimetric Electron Telescope) detector can play an
important role in indirect search for Dark Matter (DM), measuring the
electron+positron flux in the TeV region for the first time directly. With its
fine energy resolution of approximately $2\%$ and good proton rejection ratio
($1:10^5$) it has the potential to search for fine structures in the Cosmic Ray
(CR) electron spectrum. In this context we discuss the ability of CALET to
discern between signals originating from astrophysical sources and DM decay or
annihilation. We fit a parametrization of the local interstellar electron and
positron spectra to current measurements, with either a pulsar or 3-body decay
of fermionic DM as the extra source causing the positron excess. The expected
CALET data for scenarios in which DM decay explains the excess are calculated
and analyzed. The signal from this particular 3-body DM decay which can explain
the recent measurements of from the AMS$-02$ experiment is shown to be
distinguishable from a single pulsar source causing the positron excess by 5
years of observation with CALET, based on the shape of the spectrum. We also
study the constraints from extra-galactic diffuse $\gamma$-ray data on this
DM-only explanation of the positron excess and show that especially for the
possibly remaining parameter space a clearly identifiable signature in the CR
electron spectrum exists.
[12]
oai:arXiv.org:1607.00233 [pdf] - 1490766
CALET Upper Limits on X-ray and Gamma-ray Counterparts of GW 151226
Adriani, O.;
Akaike, Y.;
Asano, K.;
Asaoka, Y.;
Bagliesi, M. G.;
Bigongiari, G.;
Binns, W. R.;
Bonechi, S.;
Bongi, M.;
Brog, P.;
Buckley, J. H.;
Cannady, N.;
Castellini, G.;
Checchia, C.;
Cherry, M. L.;
Collazuol, G.;
Di Felice, V.;
Ebisawa, K.;
Fuke, H.;
Guzik, T. G.;
Hams, T.;
Hareyama, M.;
Hasebe, N.;
Hibino, K.;
Ichimura, M.;
Ioka, K.;
Ishizaki, W.;
Israel, M. H.;
Javaid, A.;
Kasahara, K.;
Kataoka, J.;
Kataoka, R.;
Katayose, Y.;
Kato, C.;
Kawanaka, N.;
Kawakubo, Y.;
Kitamura, H.;
Krawczynski, H. S.;
Krizmanic, J. F.;
Kuramata, S.;
Lomtadze, T.;
Maestro, P.;
Marrocchesi, P. S.;
Messineo, A. M.;
Mitchell, J. W.;
Miyake, S.;
Mizutani, K.;
Moiseev, A. A.;
Mori, K.;
Mori, M.;
Mori, N.;
Motz, H. M.;
Munakata, K.;
Murakami, H.;
Nakagawa, Y. E.;
Nakahira, S.;
Nishimura, J.;
Okuno, S.;
Ormes, J. F.;
Ozawa, S.;
Pacini, L.;
Palma, F.;
Papini, P.;
Penacchioni, A. V.;
Rauch, B. F.;
Ricciarini, S.;
Sakai, K.;
Sakamoto, T.;
Sasaki, M.;
Shimizu, Y.;
Shiomi, A.;
Sparvoli, R.;
Spillantini, P.;
Stolzi, F.;
Takahashi, I.;
Takayanagi, M.;
Takita, M.;
Tamura, T.;
Tateyama, N.;
Terasawa, T.;
Tomida, H.;
Torii, S.;
Tsunesada, Y.;
Uchihori, Y.;
Ueno, S.;
Vannuccini, E.;
Wefel, J. P.;
Yamaoka, K.;
Yanagita, S.;
Yoshida, A.;
Yoshida, K.;
Yuda, T.
Submitted: 2016-07-01, last modified: 2016-09-02
We present upper limits in the hard X-ray and gamma-ray bands at the time of
the LIGO gravitational-wave event GW 151226 derived from the CALorimetric
Electron Telescope (CALET) observation. The main instrument of CALET,
CALorimeter (CAL), observes gamma-rays from ~1 GeV up to 10 TeV with a field of
view of ~2 sr. The CALET gamma-ray burst monitor (CGBM) views ~3 sr and ~2pi sr
of the sky in the 7 keV - 1 MeV and the 40 keV - 20 MeV bands, respectively, by
using two different scintillator-based instruments. The CGBM covered 32.5% and
49.1% of the GW 151226 sky localization probability in the 7 keV - 1 MeV and 40
keV - 20 MeV bands respectively. We place a 90% upper limit of 2 x 10^{-7} erg
cm-2 s-1 in the 1 - 100 GeV band where CAL reaches 15% of the integrated LIGO
probability (~1.1 sr). The CGBM 7 sigma upper limits are 1.0 x 10^{-6} erg cm-2
s-1 (7-500 keV) and 1.8 x 10^{-6} erg cm-2 s-1 (50-1000 keV) for one second
exposure. Those upper limits correspond to the luminosity of 3-5 x 10^{49} erg
s-1 which is significantly lower than typical short GRBs.
[13]
oai:arXiv.org:1510.03168 [pdf] - 1338982
CALET's Sensitivity to Dark Matter Annihilation in the Galactic Halo
Submitted: 2015-10-12
CALET (Calorimetric Electron Telescope), installed on the ISS in August 2015,
directly measures the electron+positron cosmic rays flux up to 20 TeV. With its
proton rejection capability of 1:10^5 and an aperture of 1200 cm^2 sr, it will
provide good statistics even well above one TeV, while also featuring an energy
resolution of 2%, which allows it to detect fine structures in the spectrum.
Such structures may originate from Dark Matter annihilation or decay, making
indirect Dark Matter search one of CALET's main science objectives among others
such as identification of signatures from nearby supernova remnants, study of
the heavy nuclei spectra and gamma astronomy. The latest results from AMS-02 on
positron fraction and total electron+positron flux can be fitted with a
parametrization including a single pulsar as an extra power law source with
exponential cut-off, which emits an equal amount of electrons and positrons.
This single pulsar scenario for the positron excess is extrapolated into the
TeV region and the expected CALET data for this case are simulated. Based on
this prediction for CALET data, the sensitivity of CALET to Dark Matter
annihilation in the galactic halo has been calculated. It is shown that CALET
could significantly improve the limits compared to current data, especially for
those Dark Matter candidates that feature a large fraction of annihilation
directly into electron+positron, such as the LKP (Lightest Kaluza-Klein
Particle).
[14]
oai:arXiv.org:1202.5656 [pdf] - 1116898
Cherenkov Tau Shower Earth-Skimming Method for PeV-EeV Tau Neutrino
Observation with Ashra
Submitted: 2012-02-25, last modified: 2012-10-01
We describe a method of observation for PeV--EeV tau neutrinos using
Cherenkov light from the air showers of decayed taus produced by tau neutrino
interactions in the Earth. Aiming for the realization of neutrino astronomy
utilizing the Earth-skimming tau neutrino detection technique, highly precise
determination of arrival direction is key due to the following issues: (1)
Clear identification of neutrinos by identifying those vertices originating
within the Earth's surface; (2) Identification of very high energy neutrino
sources. The Ashra detector uses newly developed light collectors which realize
both a 42 degree-diameter field-of-view and arcminute resolution. Therefore, it
has superior angular resolution for imaging Cherenkov air showers. In this
paper, we estimate the sensitivity of and cosmic-ray background resulting from
application of the Ashra-1 Cherenkov tau shower observation method. Both data
from a commissioning run and a long-term observation (with fully equipped
trigger system and one light collector) are presented. Our estimates are based
on a detailed Monte Carlo simulation which describes all relevant shower
processes from neutrino interaction to Cherenkov photon detection produced by
tau air showers. In addition, the potential to determine the arrival direction
of Cherenkov showers is evaluated by using the maximum likelihood method. We
conclude that the Ashra-1 detector is a unique probe into detection of very
high energy neutrinos and their accelerators.
[15]
oai:arXiv.org:1106.2572 [pdf] - 379400
Observational Search for PeV-EeV Tau Neutrino from GRB081203A
Aita, Y.;
Aoki, T.;
Asaoka, Y.;
Chonan, T.;
Jobashi, M.;
Masuda, M.;
Morimoto, Y.;
Noda, K.;
Sasaki, M.;
Asoh, J.;
Ishikawa, N.;
Ogawa, S.;
Learned, J. G.;
Matsuno, S.;
Olsen, S.;
Binder, P. -M.;
Hamilton, J.;
Sugiyama, N.;
Watanabe, Y.
Submitted: 2011-06-13, last modified: 2011-06-29
We report the first observational search for tau neutrinos from gamma ray
bursts (GRBs) using one of the Ashra light collectors. The earth-skimming
tau-neutrino technique of imaging Cherenkov tau showers was applied as a
detection method. We set stringent upper limits on the tau-neutrino fluence in
PeV-EeV region for 3780 s (between 2.83 and 1.78 hours before) and another 3780
s (between 21.2 and 22.2 hours after) surrounding GRB081203A triggered by the
Swift satellite. This first search for PeV-EeV tau neutrino complements other
experiments in energy range and methodology, and suggests the prologue of
"multi-particle astronomy" with a precise determination of time and location.
[16]
oai:arXiv.org:1106.2608 [pdf] - 399928
Performance of a 20-in. photoelectric lens image intensifier tube
Submitted: 2011-06-14
We have evaluated a 20-in. photoelectric lens image intensifier tube (PLI) to
be mounted on the spherical focal surface of the Ashra light collectors, where
Ashra stands for All-sky Survey High Resolution Air-shower Detector, an
unconventional optical collector complex that images air showers produced by
very high energy cosmic-ray particles in a 42$^\circ$-diameter field of view
with a resolution of a few arcminutes. The PLI, the worlds largest image
intensifier, has a very large effective photocathode area of 20-in. diameter
and reduces an image size to less than 1-inch diameter using the electric lens
effect. This enables us to use a solid-state imager to take focal surface
images in the Ashra light collector. Thus, PLI is a key technology for the
Ashra experiment to realize a much lower pixel cost in comparison with other
experiments using photomultiplier arrays at the focal surface. In this paper we
present the design and performance of the 20-in. PLI.
[17]
oai:arXiv.org:astro-ph/0403704 [pdf] - 880720
Measurements of Primary and Atmospheric Cosmic-Ray Spectra with the
BESS-TeV Spectrometer
Haino, S.;
Sanuki, T.;
Abe, K.;
Anraku, K.;
Asaoka, Y.;
Fuke, H.;
Imori, M.;
Itasaki, A.;
Maeno, T.;
Makida, Y.;
Matsuda, S.;
Matsui, N.;
Matsumoto, H.;
Mitchell, J. W.;
Moiseev, A. A.;
Nishimura, J.;
Nozaki, M.;
Orito, S.;
Ormes, J. F.;
Sasaki, M.;
Seo, E. S.;
Shikaze, Y.;
Streitmatter, R. E.;
Suzuki, J.;
Takasugi, Y.;
Tanaka, K.;
Tanizaki, K.;
Yamagami, T.;
Yamamoto, A.;
Yamamoto, Y.;
Yamato, K.;
Yoshida, T.;
Yoshimura, K.
Submitted: 2004-03-31
Primary and atmospheric cosmic-ray spectra were precisely measured with the
BESS-TeV spectrometer. The spectrometer was upgraded from BESS-98 to achieve
seven times higher resolution in momentum measurement. We report absolute
fluxes of primary protons and helium nuclei in the energy ranges, 1-540 GeV and
1-250 GeV/n, respectively, and absolute flux of atmospheric muons in the
momentum range 0.6-400 GeV/c.
[18]
oai:arXiv.org:astro-ph/0205427 [pdf] - 49501
Measurements of atmospheric muon spectra at mountain altitude
Sanuki, T.;
Fujikawa, M.;
Abe, K.;
Anraku, K.;
Asaoka, Y.;
Fuke, H.;
Haino, S.;
Imori, M.;
Izumi, K.;
Maeno, T.;
Makida, Y.;
Matsui, N.;
Matsumoto, H.;
Matsunaga, H.;
Motoki, M.;
Nishimura, J.;
Nozaki, M.;
Orito, S.;
Sasaki, M.;
Shikaze, Y.;
Sonoda, T.;
Suzuki, J.;
Tanaka, K.;
Toki, Y.;
Yamamoto, A.;
Yamamoto, Y.;
Yamato, K.;
Yoshida, T.;
Yoshimura, K.
Submitted: 2002-05-24, last modified: 2003-11-29
We report new measurements of the atmospheric muons at mountain altitude. The
measurement was carried out with the BESS detector at the top of Mt. Norikura,
Japan. The altitude is 2,770 m above sea level. Comparing our results and
predictions given by some interaction models, a further appropriate model has
been investigated. These studies would improve accuracy of atmospheric neutrino
calculations.
[19]
oai:arXiv.org:astro-ph/0304102 [pdf] - 56010
Measurements of Proton, Helium and Muon Spectra at Small Atmospheric
Depths with the BESS Spectrometer
Abe, K.;
Sanuki, T.;
Anraku, K.;
Asaoka, Y.;
Fuke, H.;
Haino, S.;
Ikeda, N.;
Imori, M.;
Izumi, K.;
Maeno, T.;
Makida, Y.;
Matsuda, S.;
Matsui, N.;
Matsukawa, T.;
Matsumoto, H.;
Mitchell, J. W.;
Moiseev, A. A.;
Nishimura, J.;
Nozaki, M.;
Orito, S.;
Ormes, J. F.;
Sasaki, M.;
Seo, E. S.;
Shikaze, Y.;
Sonoda, T.;
Streitmatter, R. E.;
Suzuki, J.;
Tanaka, K.;
Tanizaki, K.;
Yamagami, T.;
Yamamoto, A.;
Yamamoto, Y.;
Yamato, K.;
Yoshida, T.;
Yoshimura, K.
Submitted: 2003-04-05, last modified: 2003-05-06
The cosmic-ray proton, helium, and muon spectra at small atmospheric depths
of 4.5 -- 28 g/cm^2 were precisely measured during the slow descending period
of the BESS-2001 balloon flight. The variation of atmospheric secondary
particle fluxes as a function of atmospheric depth provides fundamental
information to study hadronic interactions of the primary cosmic rays with the
atmosphere.
[20]
oai:arXiv.org:astro-ph/0204167 [pdf] - 48712
Detecting Very High Energy Neutrinos by the Telescope Array
Submitted: 2002-04-09, last modified: 2002-07-15
We present the cosmic neutrino detecting potential of the Telescope Array for
quasihorizontally downward and upward air showers initiated by very high energy
neutrinos penetrating the air and the Earth respectively. We adopted model
predictions for extraterrestrial neutrino fluxes from active galactic nuclei,
gamma-ray bursters, Greisen photo production, the collapse of topological
defects, and Z-bursts. The Telescope Array, using a large array of bright and
wide field-of-view flourescence telescopes, can esplore these very high energy
cosmic neutrino sources.
[21]
oai:arXiv.org:astro-ph/0205344 [pdf] - 49418
Precise Measurements of Atmospheric Muon Fluxes with the BESS
Spectrometer
Motoki, M.;
Sanuki, T.;
Orito, S.;
Abe, K.;
Anraku, K.;
Asaoka, Y.;
Fujikawa, M.;
Fuke, H.;
Haino, S.;
Imori, M.;
Izumi, K.;
Maeno, T.;
Makida, Y.;
Matsui, N.;
Matsumoto, H.;
Matsunaga, H.;
Mitchell, J.;
Mitsui, T.;
Moiseev, A.;
Nishimura, J.;
Nozaki, M.;
Ormes, J.;
Saeki, T.;
Sasaki, M.;
Seo, E. S.;
Shikaze, Y.;
Sonoda, T.;
Streitmatter, R.;
Suzuki, J.;
Tanaka, K.;
Ueda, I.;
Wang, J. Z.;
Yajima, N.;
Yamagami, T.;
Yamamoto, A.;
Yamamoto, Y.;
Yamato, K.;
Yoshida, T.;
Yoshimura, K.
Submitted: 2002-05-21
The vertical absolute fluxes of atmospheric muons and muon charge ratio have
been measured precisely at different geomagnetic locations by using the BESS
spectrometer. The observations had been performed at sea level (30 m above sea
level) in Tsukuba, Japan, and at 360 m above sea level in Lynn Lake, Canada.
The vertical cutoff rigidities in Tsukuba (36.2 N, 140.1 E) and in Lynn Lake
(56.5 N, 101.0 W) are 11.4 GV and 0.4 GV, respectively. We have obtained
vertical fluxes of positive and negative muons in a momentum range from 0.6 to
20 GeV/c with systematic errors less than 3 % in both measurements. By
comparing the data collected at two different geomagnetic latitudes, we have
seen an effect of cutoff rigidity. The dependence on the atmospheric pressure
and temperature, and the solar modulation effect have been also clearly
observed. We also clearly observed the decrease of charge ratio of muons at low
momentum side with at higher cutoff rigidity region.
[22]
oai:arXiv.org:astro-ph/0203348 [pdf] - 387052
Design of UHECR telescope with 1 arcmin resolution and 50 degree field
of view
Submitted: 2002-03-20, last modified: 2002-04-27
A new telescope design based on Baker-Nunn optics is proposed for observation
of ultra high-energy cosmic rays (UHECRs). The optical system has an image
resolution of smaller than 0.02$^\circ$ within a wide field of view of
50$^\circ$ angular diameter. When combined with a high-quality imaging device,
the proposed design enables the directions of UHECRs and high-energy neutrinos
to be determined with accuracy of better than 1 arcmin. The outstanding
resolution of this telescope allows charge-separated cosmic-rays to be resolved
and the source to be determined accurately. This marked improvement in angular
resolution will allow the multi-wavelength and ``multi-particle'' observations
of astronomical objects through collaboration with established astronomical
observations.
[23]
oai:arXiv.org:astro-ph/0109007 [pdf] - 387045
Measurements of Cosmic-ray Low-energy Antiproton and Proton Spectra in a
Transient Period of the Solar Field Reversal
Asaoka, Y.;
Shikaze, Y.;
Abe, K.;
Anraku, K.;
Fujikawa, M.;
Fuke, H.;
Haino, S.;
Imori, M.;
Izumi, K.;
Maeno, T.;
Makida, Y.;
Matsuda, S.;
Matsui, N.;
Matsukawa, T.;
Matsumoto, H.;
Matsunaga, H.;
Mitchell, J.;
Mitsui, T.;
Moiseev, A.;
Motoki, M.;
Nishimura, J.;
Nozaki, M.;
Orito, S.;
Ormes, J. F.;
Saeki, T.;
Sanuki, T.;
Sasaki, M.;
Seo, E. S.;
Sonoda, T.;
Streitmatter, R.;
Suzuki, J.;
Tanaka, K.;
Tanizaki, K.;
Ueda, I.;
Wang, J. Z.;
Yajima, Y.;
Yamagami, Y.;
Yamamoto, A.;
Yamamoto, Y.;
Yamato, K.;
Yoshida, T.;
Yoshimura, K.
Submitted: 2001-09-02, last modified: 2002-01-25
The energy spectra of cosmic-ray low-energy antiprotons and protons have been
measured by BESS in 1999 and 2000, during a period covering the solar magnetic
field reversal. Based on these measurements, a sudden increase of the
antiproton to proton flux ratio following the solar magnetic field reversal was
observed, and it generally agrees with a drift model of the solar modulation.
[24]
oai:arXiv.org:astro-ph/0002481 [pdf] - 34824
Precise Measurement of Cosmic-Ray Proton and Helium Spectra with the
BESS Spectrometer
Sanuki, T.;
Motoki, M.;
Matsumoto, H.;
Seo, E. S.;
Wang, J. Z.;
Abe, K.;
Anraku, K.;
Asaoka, Y.;
Fujikawa, M.;
Imori, M.;
Maeno, T.;
Makida, Y.;
Matsui, N.;
Matsunaga, H.;
Mitchell, J.;
Mitsui, T.;
Moiseev, A.;
Nishimura, J.;
Nozaki, M.;
Orito, S.;
Ormes, J.;
Saeki, T.;
Sasaki, M.;
Shikaze, Y.;
Sonoda, T.;
Streitmatter, R.;
Suzuki, J.;
Tanaka, K.;
Ueda, I.;
Yajima, N.;
Yamagami, T.;
Yamamoto, A.;
Yoshida, T.;
Yoshimura, K.
Submitted: 2000-02-25
We report cosmic-ray proton and helium spectra in energy ranges of 1 to 120
GeV and 1 to 54 GeV/nucleon, respectively, measured by a balloon flight of the
BESS spectrometer in 1998. The magnetic-rigidity of the cosmic-rays was
reliably determined by highly precise measurement of the circular track in a
uniform solenoidal magnetic field of 1 Tesla. Those spectra were determined
within overall uncertainties of +-5 % for protons and +- 10 % for helium nuclei
including statistical and systematic errors.
[25]
oai:arXiv.org:astro-ph/9906426 [pdf] - 346614
Precision Measurement of Cosmic-Ray Antiproton Spectrum
Orito, S.;
Maeno, T.;
Matsunaga, H.;
Abe, K.;
Anraku, K.;
Asaoka, Y.;
Fujikawa, M.;
Imori, M.;
Ishino, M.;
Makida, Y.;
Matsui, N.;
Matsumoto, H.;
Mitchell, J.;
Mitsui, T.;
Moiseev, A.;
Motoki, M.;
Nishimura, J.;
Nozaki, M.;
Ormes, J.;
Saeki, T.;
Sanuki, T.;
Sasaki, M.;
Seo, E. S.;
Shikaze, Y.;
Sonoda, T.;
Streitmatter, R.;
Suzuki, J.;
Tanaka, K.;
Ueda, I.;
Yajima, N.;
Yamagami, T.;
Yamamoto, A.;
Yoshida, T.;
Yoshimura, K.
Submitted: 1999-06-26
The energy spectrum of cosmic-ray antiprotons has been measured in the range
0.18 to 3.56 GeV, based on 458 antiprotons collected by BESS in recent
solar-minimum period. We have detected for the first time a distinctive peak at
2 GeV of antiprotons originating from cosmic-ray interactions with the
interstellar gas. The peak spectrum is reproduced by theoretical calculations,
implying that the propagation models are basically correct and that different
cosmic-ray species undergo a universal propagation. Future BESS flights toward
the solar maximum will help us to study the solar modulation and the
propagation in detail and to search for primary antiproton components.