Normalized to: Artusa, D.
[1]
oai:arXiv.org:1209.2519 [pdf] - 621874
The low energy spectrum of TeO2 bolometers: results and dark matter
perspectives for the CUORE-0 and CUORE experiments
Alessandria, F.;
Ardito, R.;
Artusa, D. R.;
Avignone, F. T.;
Azzolini, O.;
Balata, M.;
Banks, T. I.;
Bari, G.;
Beeman, J.;
Bellini, F.;
Bersani, A.;
Biassoni, M.;
Bloxham, T.;
Brofferio, C.;
Bucci, C.;
Cai, X. Z.;
Canonica, L.;
Capelli, S.;
Carbone, L.;
Cardani, L.;
Carrettoni, M.;
Casali, N.;
Chott, N.;
Clemenza, M.;
Cosmelli, C.;
Cremonesi, O.;
Creswick, R. J.;
Dafinei, I.;
Dally, A.;
Datskov, V.;
De Biasi, A.;
Decowski, M. P.;
Deninno, M. M.;
Di Domizio, S.;
di Vacri, M. L.;
Ejzak, L.;
Faccini, R.;
Fang, D. Q.;
Farach, H. A.;
Ferri, E.;
Ferroni, F.;
Fiorini, E.;
Franceschi, M. A.;
Freedman, S. J.;
Frossati, G.;
Fujikawa, B. K.;
Giachero, A.;
Gironi, L.;
Giuliani, A.;
Goett, J. J.;
Gorla, P.;
Gotti, C.;
Guardincerri, E.;
Gutierrez, T. D.;
Haller, E. E.;
Han, K.;
Heeger, K. M.;
Huang, H. Z.;
Kadel, R.;
Kazkaz, K.;
Keppel, G.;
Kogler, L.;
Kolomensky, Yu. G.;
Lenz, D.;
Li, Y. L.;
Ligi, C.;
Liu, X.;
Ma, Y. G.;
Maiano, C.;
Maino, M.;
Martinez, M.;
Maruyama, R. H.;
Moggi, N.;
Morganti, S.;
Napolitano, T.;
Newman, S.;
Nisi, S.;
Nones, C.;
Norman, E. B.;
Nucciotti, A.;
Orio, F.;
Orlandi, D.;
Ouellet, J. L.;
Pallavicini, M.;
Palmieri, V.;
Pattavina, L.;
Pavan, M.;
Pedretti, M.;
Pessina, G.;
Pirro, S.;
Previtali, E.;
Rampazzo, V.;
Rimondi, F.;
Rosenfeld, C.;
Rusconi, C.;
Sangiorgio, S.;
Scielzo, N. D.;
Sisti, M.;
Smith, A. R.;
Stivanello, F.;
Taffarello, L.;
Tenconi, M.;
Tian, W. D.;
Tomei, C.;
Trentalange, S.;
Ventura, G.;
Vignati, M.;
Wang, B. S.;
Wang, H. W.;
Whitten, C. A.;
Wise, y T.;
Woodcraft, A.;
Zanotti, L.;
Zarra, C.;
Zhu, B. X.;
Zucchelli, S.
Submitted: 2012-09-12, last modified: 2013-02-01
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three
of them we were able to set the energy threshold around 3 keV using a new
analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3
keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak
is presently unknown, but its presence is confirmed by a reanalysis of 62.7
kg.days of data from the finished CUORICINO experiment. Finally, we report the
expected sensitivities of the CUORE0 (52 bolometers) and CUORE (988 bolometers)
experiments to a WIMP annual modulation signal.
[2]
oai:arXiv.org:astro-ph/0206254 [pdf] - 49885
BOOMERANG: A Balloon-borne Millimeter Wave Telescope and Total Power
Receiver for Mapping Anisotropy in the Cosmic Microwave Background
Crill, B. P.;
Ade, P. A. R.;
Artusa, D. R.;
Bhatia, R. S.;
Bock, J. J.;
Boscaleri, A.;
Cardoni, P.;
Church, S. E.;
Coble, K.;
deBernardis, P.;
deTroia, G.;
Farese, P.;
Ganga, K. M.;
Giacometti, M.;
Haynes, C. V.;
Hivon, E.;
Hristov, V. V.;
Iacoangeli, A.;
Jones, W. C.;
Lange, A. E.;
Martinis, L.;
Masi, S.;
Mason, P. V.;
Mauskopf, P. D.;
Miglio, L.;
Montroy, T.;
Netterfield, C. B.;
Paine, C. G.;
Pascale, E.;
Piacentini, F.;
Polenta, G.;
Pongetti, F.;
Romeo, G.;
Ruhl, J. E.;
Scaramuzzi, F.;
Sforna, D.;
Turner, A. D.
Submitted: 2002-06-14, last modified: 2002-12-13
We describe BOOMERANG; a balloon-borne microwave telescope designed to map
the Cosmic Microwave Background (CMB) at a resolution of 10' from the Long
Duration Balloon (LDB) platform. The millimeter-wave receiver employs new
technology in bolometers, readout electronics, cold re-imaging optics,
millimeter-wave filters, and cryogenics to obtain high sensitivity to CMB
anisotropy. Sixteen detectors observe in 4 spectral bands centered at 90, 150,
240 and 410 GHz. The wide frequency coverage, the long duration flight, the
optical design and the observing strategy provide strong rejection of
systematic effects. We report the flight performance of the instrument during a
10.5 day stratospheric balloon flight launched from McMurdo Station, Antarctica
that mapped ~2000 square degrees of the sky.