Normalized to: Artal, E.
[1]
oai:arXiv.org:1802.04594 [pdf] - 1634424
The QUIJOTE Experiment: Prospects for CMB B-MODE polarization detection
and foregrounds characterization
Poidevin, F.;
Rubino-Martin, J. A.;
Genova-Santos, R.;
Rebolo, R.;
Aguiar, M.;
Gomez-Renasco, F.;
Guidi., F.;
Gutierrez, C.;
Hoyland, R. J.;
Lopez-Caraballo, C.;
Carreras, A. Oria;
Pelaez-Santos, A. E.;
Perez-De-Taoro, M. R.;
Ruiz-Granados, B.;
Tramonte, D.;
Vega-Moreno, A.;
Viera-Curbelo, T.;
Vignaga, R.;
Martinez-Gonzalez, E.;
Barreiro, R. B.;
Casaponsa, B.;
Casas, F. J.;
Diego, J. M.;
Fernandez-Cobos, R.;
Herranz, D.;
Lopez-Caniego, M.;
Ortiz, D.;
Vielva, P.;
Artal, E.;
Aja, B.;
Cagigas, J.;
Cano, J. L.;
De La Fuente, L.;
Mediavilla, A.;
Teran, J. V.;
Villa, E.;
Piccirillo, L.;
Dickinson, C.;
Grainge, K.;
Harper, S.;
Mcculloch, M.;
Melhuish, S.;
Pisano, G.;
Watson, R. A.;
Lasenby, A.;
Ashdown, M.;
Perrott, Y.;
Razavi-Ghods, N.;
Titterington, D.;
Scott, P.
Submitted: 2018-02-13
QUIJOTE (Q-U-I JOint TEnerife) is an experiment designed to achieve CMB
B-mode polarization detection and sensitive enough to detect a primordial
gravitational-wave component if the B-mode amplitude is larger than r = 0.05.
It consists in two telescopes and three instruments observing in the frequency
range 10-42 GHz installed at the Teide Observatory in the Canary Islands,
Spain. The observing strategy includes three raster scan deep integration
fields for cosmology, a nominal wide survey covering the Northen Sky and
specific raster scan deep integration observations in regions of specific
interest. The main goals of the project are presented and the first scientific
results obtained with the first instrument are reviewed.
[2]
oai:arXiv.org:1706.04516 [pdf] - 1935364
Exploring Cosmic Origins with CORE: Survey requirements and mission
design
Delabrouille, J.;
de Bernardis, P.;
Bouchet, F. R.;
Achúcarro, A.;
Ade, P. A. R.;
Allison, R.;
Arroja, F.;
Artal, E.;
Ashdown, M.;
Baccigalupi, C.;
Ballardini, M.;
Banday, A. J.;
Banerji, R.;
Barbosa, D.;
Bartlett, J.;
Bartolo, N.;
Basak, S.;
Baselmans, J. J. A.;
Basu, K.;
Battistelli, E. S.;
Battye, R.;
Baumann, D.;
Benoît, A.;
Bersanelli, M.;
Bideaud, A.;
Biesiada, M.;
Bilicki, M.;
Bonaldi, A.;
Bonato, M.;
Borrill, J.;
Boulanger, F.;
Brinckmann, T.;
Brown, M. L.;
Bucher, M.;
Burigana, C.;
Buzzelli, A.;
Cabass, G.;
Cai, Z. -Y.;
Calvo, M.;
Caputo, A.;
Carvalho, C. -S.;
Casas, F. J.;
Castellano, G.;
Catalano, A.;
Challinor, A.;
Charles, I.;
Chluba, J.;
Clements, D. L.;
Clesse, S.;
Colafrancesco, S.;
Colantoni, I.;
Contreras, D.;
Coppolecchia, A.;
Crook, M.;
D'Alessandro, G.;
D'Amico, G.;
da Silva, A.;
de Avillez, M.;
de Gasperis, G.;
De Petris, M.;
de Zotti, G.;
Danese, L.;
Désert, F. -X.;
Desjacques, V.;
Di Valentino, E.;
Dickinson, C.;
Diego, J. M.;
Doyle, S.;
Durrer, R.;
Dvorkin, C.;
Eriksen, H. -K.;
Errard, J.;
Feeney, S.;
Fernández-Cobos, R.;
Finelli, F.;
Forastieri, F.;
Franceschet, C.;
Fuskeland, U.;
Galli, S.;
Génova-Santos, R. T.;
Gerbino, M.;
Giusarma, E.;
Gomez, A.;
González-Nuevo, J.;
Grandis, S.;
Greenslade, J.;
Goupy, J.;
Hagstotz, S.;
Hanany, S.;
Handley, W.;
Henrot-Versillé, S.;
Hernández-Monteagudo, C.;
Hervias-Caimapo, C.;
Hills, M.;
Hindmarsh, M.;
Hivon, E.;
Hoang, D. T.;
Hooper, D. C.;
Hu, B.;
Keihänen, E.;
Keskitalo, R.;
Kiiveri, K.;
Kisner, T.;
Kitching, T.;
Kunz, M.;
Kurki-Suonio, H.;
Lagache, G.;
Lamagna, L.;
Lapi, A.;
Lasenby, A.;
Lattanzi, M.;
Brun, A. M. C. Le;
Lesgourgues, J.;
Liguori, M.;
Lindholm, V.;
Lizarraga, J.;
Luzzi, G.;
Macìas-Pérez, J. F.;
Maffei, B.;
Mandolesi, N.;
Martin, S.;
Martinez-Gonzalez, E.;
Martins, C. J. A. P.;
Masi, S.;
Massardi, M.;
Matarrese, S.;
Mazzotta, P.;
McCarthy, D.;
Melchiorri, A.;
Melin, J. -B.;
Mennella, A.;
Mohr, J.;
Molinari, D.;
Monfardini, A.;
Montier, L.;
Natoli, P.;
Negrello, M.;
Notari, A.;
Noviello, F.;
Oppizzi, F.;
O'Sullivan, C.;
Pagano, L.;
Paiella, A.;
Pajer, E.;
Paoletti, D.;
Paradiso, S.;
Partridge, R. B.;
Patanchon, G.;
Patil, S. P.;
Perdereau, O.;
Piacentini, F.;
Piat, M.;
Pisano, G.;
Polastri, L.;
Polenta, G.;
Pollo, A.;
Ponthieu, N.;
Poulin, V.;
Prêle, D.;
Quartin, M.;
Ravenni, A.;
Remazeilles, M.;
Renzi, A.;
Ringeval, C.;
Roest, D.;
Roman, M.;
Roukema, B. F.;
Rubino-Martin, J. -A.;
Salvati, L.;
Scott, D.;
Serjeant, S.;
Signorelli, G.;
Starobinsky, A. A.;
Sunyaev, R.;
Tan, C. Y.;
Tartari, A.;
Tasinato, G.;
Toffolatti, L.;
Tomasi, M.;
Torrado, J.;
Tramonte, D.;
Trappe, N.;
Triqueneaux, S.;
Tristram, M.;
Trombetti, T.;
Tucci, M.;
Tucker, C.;
Urrestilla, J.;
Väliviita, J.;
Van de Weygaert, R.;
Van Tent, B.;
Vennin, V.;
Verde, L.;
Vermeulen, G.;
Vielva, P.;
Vittorio, N.;
Voisin, F.;
Wallis, C.;
Wandelt, B.;
Wehus, I.;
Weller, J.;
Young, K.;
Zannoni, M.
Submitted: 2017-06-14
Future observations of cosmic microwave background (CMB) polarisation have
the potential to answer some of the most fundamental questions of modern
physics and cosmology. In this paper, we list the requirements for a future CMB
polarisation survey addressing these scientific objectives, and discuss the
design drivers of the CORE space mission proposed to ESA in answer to the "M5"
call for a medium-sized mission. The rationale and options, and the
methodologies used to assess the mission's performance, are of interest to
other future CMB mission design studies. CORE is designed as a near-ultimate
CMB polarisation mission which, for optimal complementarity with ground-based
observations, will perform the observations that are known to be essential to
CMB polarisation scienceand cannot be obtained by any other means than a
dedicated space mission.
[3]
oai:arXiv.org:1605.04741 [pdf] - 1494692
QUIJOTE Scientific Results. II. Polarisation Measurements of the
Microwave Emission in the Galactic molecular complexes W43 and W47 and
supernova remnant W44
Génova-Santos, R.;
Rubiño-Martín, J. A.;
Peláez-Santos, A.;
Poidevin, F.;
Rebolo, R.;
Vignaga, R.;
Artal, E.;
Harper, S.;
Hoyland, R.;
Lasenby, A.;
Martínez-González, E.;
Piccirillo, L.;
Tramonte, D.;
Watson, R. A.
Submitted: 2016-05-16, last modified: 2016-09-28
We present Q-U-I JOint TEnerife (QUIJOTE) intensity and polarisation maps at
10-20 GHz covering a region along the Galactic plane 24<l<45 deg, |b|<8 deg.
These maps result from 210 h of data, have a sensitivity in polarisation of ~40
muK/beam and an angular resolution of ~1 deg. Our intensity data are crucial to
confirm the presence of anomalous microwave emission (AME) towards the two
molecular complexes W43 (22 sigma) and W47 (8 sigma). We also detect at high
significance (6 sigma) AME associated with W44, the first clear detection of
this emission towards a SNR. The new QUIJOTE polarisation data, in combination
with WMAP, are essential to: i) Determine the spectral index of the synchrotron
emission in W44, beta_sync =-0.62 +/-0.03, in good agreement with the value
inferred from the intensity spectrum once a free-free component is included in
the fit. ii) Trace the change in the polarisation angle associated with Faraday
rotation in the direction of W44 with rotation measure -404 +/- 49 rad/m2. And
iii) set upper limits on the polarisation of W43 of Pi_AME <0.39 per cent (95
per cent C.L.) from QUIJOTE 17~GHz, and <0.22 per cent from WMAP 41 GHz data,
which are the most stringent constraints ever obtained on the polarisation
fraction of the AME. For typical physical conditions (grain temperature and
magnetic field strengths), and in the case of perfect alignment between the
grains and the magnetic field, the models of electric or magnetic dipole
emissions predict higher polarisation fractions.
[4]
oai:arXiv.org:1504.03514 [pdf] - 979173
The QUIJOTE experiment: project overview and first results
Génova-Santos, R.;
Rubiño-Martín, J. A.;
Rebolo, R.;
Aguiar, M.;
Gómez-Reñasco, F.;
Gutiérrez, C.;
Hoyland, R. J.;
López-Caraballo, C.;
Peláez-Santos, A. E.;
de Taoro, M. R. Pérez;
Poidevin, F.;
de la Rosa, V. Sánchez;
Tramonte, D.;
Vega-Moreno, A.;
Viera-Curbelo, T.;
Vignaga, R.;
Martínez-González, E.;
Barreiro, R. B.;
Casaponsa, B.;
Casas, F. J.;
Diego, J. M.;
Fernández-Cobos, R.;
Herranz, D.;
López-Caniego, M.;
Ortiz, D.;
Vielva, P.;
Artal, E.;
Aja, B.;
Cagigas, J.;
Cano, J. L.;
de la Fuente, L.;
Mediavilla, A.;
Terán, J. V.;
Villa, E.;
Piccirillo, L.;
Davies;
Davis, R. J.;
Dickinson, C.;
Grainge, K.;
Harper, S.;
Maffei, B.;
McCulloch, M.;
Melhuish, S.;
Pisano, G.;
Watson, R. A.;
Lasenby, A.;
Ashdown, M.;
Hobson, M.;
Perrott, Y.;
Razavi-Ghods, N.;
Saunders, R.;
Titterington, D.;
Scott, P.
Submitted: 2015-04-14
QUIJOTE (Q-U-I JOint TEnerife) is a new polarimeter aimed to characterize the
polarization of the Cosmic Microwave Background and other Galactic and
extragalactic signals at medium and large angular scales in the frequency range
10-40 GHz. The multi-frequency (10-20~GHz) instrument, mounted on the first
QUIJOTE telescope, saw first light on November 2012 from the Teide Observatory
(2400~m a.s.l). During 2014 the second telescope has been installed at this
observatory. A second instrument at 30~GHz will be ready for commissioning at
this telescope during summer 2015, and a third additional instrument at 40~GHz
is now being developed. These instruments will have nominal sensitivities to
detect the B-mode polarization due to the primordial gravitational-wave
component if the tensor-to-scalar ratio is larger than r=0.05.
[5]
oai:arXiv.org:1401.4690 [pdf] - 780687
The QUIJOTE CMB Experiment: status and first results with the
multi-frequency instrument
López-Caniego, M.;
Rebolo, R.;
Aguiar, M.;
Génova-Santos, R.;
Gómez-Reñasco, F.;
Gutierrez, C.;
Herreros, J. M.;
Hoyland, R. J.;
López-Caraballo, C.;
Santos, A. E. Pelaez;
Poidevin, F.;
Rubiño-Martín, J. A.;
de la Rosa, V. Sanchez;
Tramonte, D.;
Vega-Moreno, A.;
Viera-Curbelo, T.;
Vignaga, R.;
Martínez-González, E.;
Barreiro, R. B.;
Casaponsa, B.;
Casas, F. J.;
Diego, J. M.;
Fernández-Cobos, R.;
Herranz, D.;
Ortiz, D.;
Vielva, P.;
Artal, E.;
Aja, B.;
Cagigas, J.;
Cano, J. L.;
de la Fuente, L.;
Mediavilla, A.;
Terán, J. V.;
Villa, E.;
Piccirillo, L.;
Battye, R.;
Blackhurst, E.;
Brown, M.;
Davies, R. D.;
Davis, R. J.;
Dickinson, C.;
Grainge, K.;
Harper, S.;
Maffei, B.;
McCulloch, M.;
Melhuish, S.;
Pisano, G.;
Watson, R. A.;
Hobson, M.;
Lasenby, A.;
Saunders, R.;
Scott, P.
Submitted: 2014-01-19, last modified: 2014-02-05
The QUIJOTE (Q-U-I JOint Tenerife) CMB Experiment is designed to observe the
polarization of the Cosmic Microwave Background and other Galactic and
extragalactic signals at medium and large angular scales in the frequency range
of 10-40 GHz. The first of the two QUIJOTE telescopes and the multi-frequency
(10-20 GHz) instrument have been in operation since November 2012. In 2014 a
second telescope and a new instrument at 30GHz will be ready for commissioning,
and an additional instrument at 40 GHz is in its final design stages. After
three years of effective observations, the data obtained by these telescopes
and instruments will have the required sensitivity to detect a primordial
gravitational-wave component if the tensor-to-scalar ratio is larger than r =
0.05. At the moment, we have completed half of the wide Galactic survey with
the multi-frequency instrument covering 18 000 square degrees of the Northern
hemisphere. When we finish this survey in early 2014, we shall have reached
approximately 14{\mu}K per one degree beam at 11, 13, 17 and 19 GHz, in both Q
and U.
[6]
oai:arXiv.org:1101.2038 [pdf] - 955981
Planck early results. III. First assessment of the Low Frequency
Instrument in-flight performance
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Curto, A.;
Cuttaia, F.;
Davis, R. J.;
Dick, J.;
Frailis, M.;
Galeotta, S.;
Gregorio, A.;
Kurki-Suonio, H.;
Lawrence, C. R.;
Leach, S.;
Leahy, J. P.;
Lowe, S.;
Maino, D.;
Mandolesi, N.;
Maris, M.;
Martínez-González, E.;
Meinhold, P. R.;
Morgante, G.;
Pearson, D.;
Perrotta, F.;
Polenta, G.;
Poutanen, T.;
Sandri, M.;
Seiffert, M. D.;
Suur-Uski, A. -S.;
Tavagnacco, D.;
Terenzi, L.;
Tomasi, M.;
Valiviita, J.;
Villa, F.;
Watson, R.;
Wilkinson, A.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Baccigalupi, C.;
Banday, A. J.;
Barreiro, R. B.;
Bartlett, J. G.;
Bartolo, N.;
Battaglia, P.;
Bennett, K.;
Bonaldi, A.;
Bonavera, L.;
Borrill, J.;
Bouchet, F. R.;
Burigana, C.;
Cabella, P.;
Cappellini, B.;
Chen, X.;
Colombo, L.;
Cruz, M.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
de Gasperis, G.;
de Rosa, A.;
de Zotti, G.;
Dickinson, C.;
Diego, J. M.;
Donzelli, S.;
Efstathiou, G.;
Enßlin, T. A.;
Eriksen, H. K.;
Falvella, M. C.;
Finelli, F.;
Foley, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T. C.;
Génova-Santos, R. T.;
George, D.;
Gómez, F.;
González-Nuevo, J.;
Górski, K. M.;
Gruppuso, A.;
Hansen, F. K.;
Herranz, D.;
Herreros, J. M.;
Hoyland, R. J.;
Hughes, N.;
Jewell, J.;
Jukkala, P.;
Juvela, M.;
Kangaslahti, P.;
Keihänen, E.;
Keskitalo, R.;
Kilpia, V. -H.;
Kisner, T. S.;
Knoche, J.;
Knox, L.;
Laaninen, M.;
Lähteenmäki, A.;
Lamarre, J. -M.;
Leonardi, R.;
León-Tavares, J.;
Leutenegger, P.;
Lilje, P. B.;
López-Caniego, M.;
Lubin, P. M.;
Malaspina, M.;
Marinucci, D.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Melchiorri, A.;
Mendes, L.;
Miccolis, M.;
Migliaccio, M.;
Mitra, S.;
Moss, A.;
Natoli, P.;
Nesti, R.;
Nørgaard-Nielsen, H. U.;
Pagano, L.;
Paladini, R.;
Paoletti, D.;
Partridge, B.;
Pasian, F.;
Pettorino, V.;
Pietrobon, D.;
Pospieszalski, M.;
Prézeau, G.;
Prina, M.;
Procopio, P.;
Puget, J. -L.;
Quercellini, C.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Ricciardi, S.;
Robbers, G.;
Rocha, G.;
Roddis, N.;
Rubiño-Martín, J. A.;
Savelainen, M.;
Scott, D.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Tauber, J. A.;
Tofani, G.;
Toffolatti, L.;
Tuovinen, J.;
Türler, M.;
Umana, G.;
Valenziano, L.;
Varis, J.;
Vielva, P.;
Vittorio, N.;
Wade, L. A.;
Watson, C.;
White, S. D. M.;
Winder, F.
Submitted: 2011-01-11, last modified: 2011-12-19
The scientific performance of the Planck Low Frequency Instrument (LFI) after
one year of in-orbit operation is presented. We describe the main optical
parameters and discuss photometric calibration, white noise sensitivity, and
noise properties. A preliminary evaluation of the impact of the main systematic
effects is presented. For each of the performance parameters, we outline the
methods used to obtain them from the flight data and provide a comparison with
pre-launch ground assessments, which are essentially confirmed in flight.
[7]
oai:arXiv.org:1005.2541 [pdf] - 1032478
Planck pre-launch status: calibration of the Low Frequency Instrument
flight model radiometers
Villa, F.;
Terenzi, L.;
Sandri, M.;
Meinhold, P.;
Poutanen, T.;
Battaglia, P.;
Franceschet, C.;
Hughes, N.;
Laaninen, M.;
Lapolla, P.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Frailis, M.;
Franceschi, E.;
Galeotta, S.;
Gregorio, A.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Stringhetti, L.;
Tomasi, M.;
Valenziano, L.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Balasini, M.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Cappellini, B.;
Cavaliere, F.;
Colin, A.;
Colombo, F.;
Davis, R. J.;
De La Fuente, L.;
Edgeley, J.;
Gaier, T.;
Galtress, A.;
Hoyland, R.;
Jukkala, P.;
Kettle, D.;
Kilpia, V-H.;
Lawrence, C. R.;
Lawson, D.;
Leahy, J. P.;
Leutenegger, P.;
Levin, S.;
Maino, D.;
Malaspina, M.;
Mediavilla, A.;
Miccolis, M.;
Pagan, L.;
Pascual, J. P.;
Pasian, F.;
Pecora, M.;
Pospieszalski, M.;
Roddis, N.;
Salmon, M. J.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Sozzi, C.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-05-14
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries
eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each
composed of a pair of pseudo-correlation receivers. We describe the on-ground
calibration campaign performed to qualify the flight model RCAs and to measure
their pre-launch performances. Each RCA was calibrated in a dedicated
flight-like cryogenic environment with the radiometer front-end cooled to 20K
and the back-end at 300K, and with an external input load cooled to 4K. A
matched load simulating a blackbody at different temperatures was placed in
front of the sky horn to derive basic radiometer properties such as noise
temperature, gain, and noise performance, e.g. 1/f noise. The spectral response
of each detector was measured as was their susceptibility to thermal variation.
All eleven LFI RCAs were calibrated. Instrumental parameters measured in these
tests, such as noise temperature, bandwidth, radiometer isolation, and
linearity, provide essential inputs to the Planck-LFI data analysis.
[8]
oai:arXiv.org:1001.4771 [pdf] - 33190
LFI 30 and 44 GHz receivers Back-End Modules
Artal, E.;
Aja, B.;
de la Fuente, M. L.;
Pascual, J. P.;
Mediavilla, A.;
Martinez-Gonzalez, E.;
Pradell, L.;
de Paco, P.;
Bara, M.;
Blanco, E.;
Garcia, E.;
Davis, R.;
Kettle, D.;
Roddis, N.;
Wilkinson, A.;
Bersanelli, M.;
Mennella, A.;
Tomasi, M.;
Butler, R. C.;
Cuttaia, F.;
Mandolesi, N.;
Stringhetti, L.
Submitted: 2010-01-26, last modified: 2010-01-27
The 30 and 44 GHz Back End Modules (BEM) for the Planck Low Frequency
Instrument are broadband receivers (20% relative bandwidth) working at room
temperature. The signals coming from the Front End Module are amplified, band
pass filtered and finally converted to DC by a detector diode. Each receiver
has two identical branches following the differential scheme of the Planck
radiometers. The BEM design is based on MMIC Low Noise Amplifiers using GaAs
P-HEMT devices, microstrip filters and Schottky diode detectors. Their
manufacturing development has included elegant breadboard prototypes and
finally qualification and flight model units. Electrical, mechanical and
environmental tests were carried out for the characterization and verification
of the manufactured BEMs. A description of the 30 and 44 GHz Back End Modules
of Planck-LFI radiometers is given, with details of the tests done to determine
their electrical and environmental performances. The electrical performances of
the 30 and 44 GHz Back End Modules: frequency response, effective bandwidth,
equivalent noise temperature, 1/f noise and linearity are presented.
[9]
oai:arXiv.org:1001.4610 [pdf] - 33148
The linearity response of the Planck-LFI flight model receivers
Mennella, A.;
Villa, F.;
Terenzi, L.;
Cuttaia, F.;
Battaglia, P.;
Bersanelli, M.;
Butler, R. C.;
D'Arcangelo, O.;
Artal, E.;
Davis, R.;
Frailis, M.;
Franceschet, C.;
Galeotta, S.;
Gregorio, A.;
Hughes, N.;
Jukkala, P.;
Kettle, D.;
Kilpiä, V. -H.;
Laaninen, M.;
Lapolla, P. M.;
Leonardi, R.;
Leutenegger, P.;
Lowe, S.;
Mandolesi, N.;
Maris, M.;
Meinhold, P.;
Mendes, L.;
Miccolis, M.;
Morgante, G.;
Roddis, N.;
Sandri, M.;
Silvestri, R.;
Stringhetti, L.;
Tomasi, M.;
Tuovinen, J.;
Valenziano, L.;
Zacchei, A.;
Varis, J.;
Wilkinson, A.;
Zonca, A.
Submitted: 2010-01-26
In this paper we discuss the linearity response of the Planck-LFI receivers,
with particular reference to signal compression measured on the 30 and 44 GHz
channels. In the article we discuss the various sources of compression and
present a model that accurately describes data measured during tests performed
with individual radiomeric chains. After discussing test results we present the
best parameter set representing the receiver response and discuss the impact of
non linearity on in-flight calibration, which is shown to be negligible.
[10]
oai:arXiv.org:1001.4589 [pdf] - 33143
Planck-LFI radiometers' spectral response
Zonca, A;
Franceschet, C;
Battaglia, P;
Villa, F;
Mennella, A;
D'Arcangelo, O;
Silvestri, R;
Bersanelli, M;
Artal, E;
Butler, R C;
Cuttaia, F;
Davis, R J;
Galeotta, S;
Hughes, N;
Jukkala, P;
Kilpia, V-H;
Laaninen, M;
Mandolesi, N;
Maris, M;
Mendes, L;
Sandri, M;
Terenzi, L;
Tuovinen, J;
Varis, J;
Wilkinson, A
Submitted: 2010-01-26
The Low Frequency Instrument (LFI) is an array of pseudo-correlation
radiometers on board the Planck satellite, the ESA mission dedicated to
precision measurements of the Cosmic Microwave Background. The LFI covers three
bands centred at 30, 44 and 70 GHz, with a goal bandwidth of 20% of the central
frequency.
The characterization of the broadband frequency response of each radiometer
is necessary to understand and correct for systematic effects, particularly
those related to foreground residuals and polarization measurements. In this
paper we present the measured band shape of all the LFI channels and discuss
the methods adopted for their estimation. The spectral characterization of each
radiometer was obtained by combining the measured spectral response of
individual units through a dedicated RF model of the LFI receiver scheme.
As a consistency check, we also attempted end-to-end spectral measurements of
the integrated radiometer chain in a cryogenic chamber. However, due to
systematic effects in the measurement setup, only qualitative results were
obtained from these tests. The measured LFI bandpasses exhibit a moderate level
of ripple, compatible with the instrument scientific requirements.
[11]
oai:arXiv.org:1001.4608 [pdf] - 33147
Noise Properties of the Planck-LFI Receivers
Meinhold, P.;
Leonardi, R.;
Aja, B.;
Artal, E.;
Battaglia, P.;
Bersanelli, M.;
Blackhurst, E.;
Butler, C. R.;
Cuevas, L. P.;
Cuttaia, F.;
D'Arcangelo, O.;
Davis, R.;
de la Fuente, M. L.;
Frailis, M.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Galeotta, S.;
Gregorio, A.;
Hoyland, R.;
Hughes, N.;
Jukkala, P.;
Kettle, D.;
Laaninen, M.;
Leutenegger, P.;
Lowe, S. R.;
Malaspina, M.;
Mandolesi, R.;
Maris, M.;
Martínez-González, E.;
Mendes, L.;
Mennella, A.;
Miccolis, M.;
Morgante, G.;
Roddis, N.;
Sandri, M.;
Seiffert, M.;
Salmón, M.;
Stringhetti, L.;
Poutanen, T.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Varis, J.;
Valenziano, L.;
Villa, F.;
Wilkinson, A.;
Winder, F.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-26
The Planck Low Frequency Instrument (LFI) radiometers have been tested
extensively during several dedicated campaigns. The present paper reports the
principal noise properties of the LFI radiometers.
[12]
oai:arXiv.org:1001.4743 [pdf] - 33184
Design, development and verification of the 30 and 44 GHz front-end
modules for the Planck Low Frequency Instrument
Davis, R. J.;
Wilkinson, A.;
Davies, R. D.;
Winder, W. F.;
Roddis, N.;
Blackhurst, E. J.;
Lawson, D.;
Lowe, S. R.;
Baines, C.;
Butlin, M.;
Galtress, A.;
Shepherd, D.;
Aja, B.;
Artal, E.;
Bersanelli, M.;
Butler, R. C.;
Castelli, C.;
Cuttaia, F.;
D'Arcangelo, O.;
Gaier, T.;
Hoyland, R.;
Kettle, D.;
Leonardi, R.;
Mandolesi, N.;
Mennella, A.;
Meinhold, P.;
Pospieszalski, M.;
Stringhetti, L.;
Tomasi, M.;
Valenziano, L.;
Zonca, A.
Submitted: 2010-01-26
We give a description of the design, construction and testing of the 30 and
44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the
Planck mission to be launched in 2009. The scientific requirements of the
mission determine the performance parameters to be met by the FEMs, including
their linear polarization characteristics.
The FEM design is that of a differential pseudo-correlation radiometer in
which the signal from the sky is compared with a 4-K blackbody load. The Low
Noise Amplifier (LNA) at the heart of the FEM is based on indium phosphide High
Electron Mobility Transistors (HEMTs). The radiometer incorporates a novel
phase-switch design which gives excellent amplitude and phase match across the
band.
The noise temperature requirements are met within the measurement errors at
the two frequencies. For the most sensitive LNAs, the noise temperature at the
band centre is 3 and 5 times the quantum limit at 30 and 44 GHz respectively.
For some of the FEMs, the noise temperature is still falling as the ambient
temperature is reduced to 20 K. Stability tests of the FEMs, including a
measurement of the 1/f knee frequency, also meet mission requirements.
The 30 and 44 GHz FEMs have met or bettered the mission requirements in all
critical aspects. The most sensitive LNAs have reached new limits of noise
temperature for HEMTs at their band centres. The FEMs have well-defined linear
polarization characteristcs.
[13]
oai:arXiv.org:1001.4562 [pdf] - 1024812
Planck pre-launch status: Low Frequency Instrument calibration and
expected scientific performance
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Davis, R. J.;
Frailis, M.;
Galeotta, S.;
Gregorio, A.;
Lawrence, C. R.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Meinhold, P.;
Mendes, L.;
Morgante, G.;
Sandri, M.;
Stringhetti, L.;
Terenzi, L.;
Tomasi, M.;
Valenziano, L.;
Villa, F.;
Zacchei, A.;
Zonca, A.;
Balasini, M.;
Franceschet, C.;
Battaglia, P.;
Lapolla, P. M.;
Leutenegger, P.;
Miccolis, M.;
Pagan, L.;
Silvestri, R.;
Aja, B.;
Artal, E.;
Baldan, G.;
Bastia, P.;
Bernardino, T.;
Boschini, L.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
de La Fuente, L.;
Edgeley, J.;
Falvella, M. C.;
Ferrari, F.;
Fogliani, S.;
Franceschi, E.;
Gaier, T.;
Gomez, F.;
Herreros, J. M.;
Hildebrandt, S.;
Hoyland, R.;
Hughes, N.;
Jukkala, P.;
Kettle, D.;
Laaninen, M.;
Lawson, D.;
Leahy, P.;
Levin, S.;
Lilje, P. B.;
Maino, D.;
Malaspina, M.;
Manzato, P.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Pasian, F.;
Pascual, J. P.;
Pecora, M.;
Peres-Cuevas, L.;
Platania, P.;
Pospieszalsky, M.;
Poutanen, T.;
Rebolo, R.;
Roddis, N.;
Salmon, M.;
Seiffert, M.;
Simonetto, A.;
Sozzi, C.;
Tauber, J.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-01-25
We give the calibration and scientific performance parameters of the Planck
Low Frequency Instrument (LFI) measured during the ground cryogenic test
campaign. These parameters characterise the instrument response and constitute
our best pre-launch knowledge of the LFI scientific performance. The LFI shows
excellent $1/f$ stability and rejection of instrumental systematic effects;
measured noise performance shows that LFI is the most sensitive instrument of
its kind. The set of measured calibration parameters will be updated during
flight operations through the end of the mission.
[14]
oai:arXiv.org:1001.3321 [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency
Instrument
Bersanelli, M.;
Mandolesi, N.;
Butler, R. C.;
Mennella, A.;
Villa, F.;
Aja, B.;
Artal, E.;
Artina, E.;
Baccigalupi, C.;
Balasini, M.;
Baldan, G.;
Banday, A.;
Bastia, P.;
Battaglia, P.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Burigana, C.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
Crone, G.;
Cuttaia, F.;
D'Arcangelo, O.;
Danese, L.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
De Gasperis, G. C.;
De La Fuente, L.;
De Rosa, A.;
De Zotti, G.;
Falvella, M. C.;
Ferrari, F.;
Ferretti, R.;
Figini, L.;
Fogliani, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Garavaglia, S.;
Gomez, F.;
Gorski, K.;
Gregorio, A.;
Guzzi, P.;
Herreros, J. M.;
Hildebrandt, S. R.;
Hoyland, R.;
Hughes, N.;
Janssen, M.;
Jukkala, P.;
Kettle, D.;
Kilpia, V. H.;
Laaninen, M.;
Lapolla, P. M.;
Lawrence, C. R.;
Leahy, J. P.;
Leonardi, R.;
Leutenegger, P.;
Levin, S.;
Lilje, P. B.;
Lowe, S. R.;
Lubin, D. Lawson P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Meinhold, P.;
Miccolis, M.;
Morgante, G.;
Natoli, P.;
Nesti, R.;
Pagan, L.;
Paine, C.;
Partridge, B.;
Pascual, J. P.;
Pasian, F.;
Pearson, D.;
Pecora, M.;
Perrotta, F.;
Platania, P.;
Pospieszalski, M.;
Poutanen, T.;
Prina, M.;
Rebolo, R.;
Roddis, N.;
Rubino-Martin, J. A.;
Salmon, n M. J.;
Sandri, M.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Taddei, E.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Valenziano, L.;
Varis, J.;
Vittorio, N.;
Wade, L. A.;
Wilkinson, A.;
Winder, F.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and
developed as part of the Planck space mission, the ESA program dedicated to
precision imaging of the cosmic microwave background (CMB). Planck-LFI will
observe the full sky in intensity and polarisation in three frequency bands
centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be
covered by the HFI instrument. The LFI is an array of microwave radiometers
based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers
implemented in a differential system using blackbody loads as reference
signals. The front-end is cooled to 20K for optimal sensitivity and the
reference loads are cooled to 4K to minimise low frequency noise. We provide an
overview of the LFI, discuss the leading scientific requirements and describe
the design solutions adopted for the various hardware subsystems. The main
drivers of the radiometric, optical and thermal design are discussed, including
the stringent requirements on sensitivity, stability, and rejection of
systematic effects. Further details on the key instrument units and the results
of ground calibration are provided in a set of companion papers.
[15]
oai:arXiv.org:1001.2657 [pdf] - 1024642
Planck pre-launch status: the Planck-LFI programme
Mandolesi, N.;
Bersanelli, M.;
Butler, R. C.;
Artal, E.;
Baccigalupi, C.;
Balbi, A.;
Banday, A. J.;
Barreiro, R. B.;
Bartelmann, M.;
Bennett, K.;
Bhandari, P.;
Bonaldi, A.;
Borrill, J.;
Bremer, M.;
Burigana, C.;
Bowman, R. C.;
Cabella, P.;
Cantalupo, C.;
Cappellini, B.;
Courvoisier, T.;
Crone, G.;
Cuttaia, F.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
de Gasperis, G.;
De Rosa, A.;
De Troia, G.;
de Zotti, G.;
Dick, J.;
Dickinson, C.;
Diego, J. M.;
Donzelli, S.;
Dörl, U.;
Dupac, X.;
Enßlin, T. A.;
Eriksen, H. K.;
Falvella, M. C.;
Finelli, F.;
Frailis, M.;
Franceschi, E.;
Gaier, T.;
Galeotta, S.;
Gasparo, F.;
Giardino, G.;
Gomez, F.;
Gonzalez-Nuevo, J.;
Górski, K. M.;
Gregorio, A.;
Gruppuso, A.;
Hansen, F.;
Hell, R.;
Herranz, D.;
Herreros, J. M.;
Hildebrandt, S.;
Hovest, W.;
Hoyland, R.;
Huffenberger, K.;
Janssen, M.;
Jaffe, T.;
Keihänen, E.;
Keskitalo, R.;
Kisner, T.;
Kurki-Suonio, H.;
Lähteenmäki, A.;
Lawrence, C. R.;
Leach, S. M.;
Leahy, J. P.;
Leonardi, R.;
Levin, S.;
Lilje, P. B.;
López-Caniego, M.;
Lowe, S. R.;
Lubin, P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Meinhold, P.;
Melchiorri, A.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Morigi, G.;
Morisset, N.;
Moss, A.;
Nash, A.;
Natoli, P.;
Nesti, R.;
Paine, C.;
Partridge, B.;
Pasian, F.;
Passvogel, T.;
Pearson, D.;
Pérez-Cuevas, L.;
Perrotta, F.;
Polenta, G.;
Popa, L. A.;
Poutanen, T.;
Prezeau, G.;
Prina, M.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Ricciardi, S.;
Riller, T.;
Rocha, G.;
Roddis, N.;
Rohlfs, R.;
Rubiño-Martin, J. A.;
Salerno, E.;
Sandri, M.;
Scott, D.;
Seiffert, M.;
Silk, J.;
Simonetto, A.;
Smoot, G. F.;
Sozzi, C.;
Sternberg, J.;
Stivoli, F.;
Stringhetti, L.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Türler, M.;
Valenziano, L.;
Varis, J.;
Vielva, P.;
Villa, F.;
Vittorio, N.;
Wade, L.;
White, M.;
White, S.;
Wilkinson, A.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-15
This paper provides an overview of the Low Frequency Instrument (LFI)
programme within the ESA Planck mission. The LFI instrument has been developed
to produce high precision maps of the microwave sky at frequencies in the range
27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation
spectrum. The scientific goals are described, ranging from fundamental
cosmology to Galactic and extragalactic astrophysics. The instrument design and
development are outlined, together with the model philosophy and testing
strategy. The instrument is presented in the context of the Planck mission. The
LFI approach to ground and inflight calibration is described. We also describe
the LFI ground segment. We present the results of a number of tests
demonstrating the capability of the LFI data processing centre (DPC) to
properly reduce and analyse LFI flight data, from telemetry information to
calibrated and cleaned time ordered data, sky maps at each frequency (in
temperature and polarization), component emission maps (CMB and diffuse
foregrounds), catalogs for various classes of sources (the Early Release
Compact Source Catalogue and the Final Compact Source Catalogue). The
organization of the LFI consortium is briefly presented as well as the role of
the core team in data analysis and scientific exploitation. All tests carried
out on the LFI flight model demonstrate the excellent performance of the
instrument and its various subunits. The data analysis pipeline has been tested
and its main steps verified. In the first three months after launch, the
commissioning, calibration, performance, and verification phases will be
completed, after which Planck will begin its operational life, in which LFI
will have an integral part.
[16]
oai:arXiv.org:0810.3141 [pdf] - 1000998
The Quijote CMB Experiment
Rubino-Martin, J. A.;
Rebolo, R.;
Tucci, M.;
Genova-Santos, R.;
Hildebrandt, S. R.;
Hoyland, R.;
Herreros, J. M.;
Gomez-Renasco, F.;
Caraballo, C. Lopez;
Martinez-Gonzalez, E.;
Vielva, P.;
Herranz, D.;
Casas, F. J.;
Artal, E.;
Aja, B.;
de la Fuente, L.;
Cano, J. L.;
Villa, E.;
Mediavilla, A.;
Pascual, J. P.;
Piccirillo, L.;
Maffei, B.;
Pisano, G.;
Watson, R. A.;
Davis, R.;
Davies, R.;
Battye, R.;
Saunders, R.;
Grainge, K.;
Scott, P.;
Hobson, M.;
Lasenby, A.;
Murga, G.;
Gomez, C.;
Gomez, A.;
Arino, J.;
Sanquirce, R.;
Pan, J.;
Vizcarguenaga, A.;
Etxeita, B.
Submitted: 2008-10-17
We present the current status of the QUIJOTE (Q-U-I JOint TEnerife) CMB
Experiment, a new instrument which will start operations early 2009 at Teide
Observatory, with the aim of characterizing the polarization of the CMB and
other processes of galactic and extragalactic emission in the frequency range
10-30 GHz and at large angular scales. QUIJOTE will be a valuable complement at
low frequencies for the PLANCK mission, and will have the required sensitivity
to detect a primordial gravitational-wave component if the tensor-to-scalar
ratio is larger than r=0.05.
[17]
oai:arXiv.org:astro-ph/0307116 [pdf] - 57829
Advanced pseudo-correlation radiometers for the Planck-LFI instrument
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Maino, D.;
Mandolesi, N.;
Morgante, G.;
Valenziano, L.;
Villa, F.;
Gaier, T.;
Seiffert, M.;
Levin, S.;
Lawrence, C.;
Meinhold, P.;
Lubin, P.;
Tuovinen, J.;
Varis, J.;
Karttaavi, T.;
Hughes, N.;
Jukkala, P.;
Sjman, P.;
Kangaslahti, P.;
Roddis, N.;
Kettle, D.;
Winder, F.;
Blackhurst, E.;
Davis, R.;
Wilkinson, A.;
Castelli, C.;
Aja, B.;
Artal, E.;
de la Fuente, L.;
Mediavilla, A.;
Pascual, J. P.;
Gallegos, J.;
Martinez-Gonzalez, E.;
de Paco, P.;
Pradell, L.
Submitted: 2003-07-07
The LFI (Low Frequency Instrument) on board the ESA Planck satellite is
constituted by an array of radiometric detectors actively cooled at 20 K in the
30-70 GHz frequency range in the focal plane of the Planck telescope. In this
paper we present an overview of the LFI instrument, with a particular focus on
the radiometer design. The adopted pseudo-correlation scheme uses a software
balancing technique (with a tunable parameter called gain modulation factor)
which is effective in reducing the radiometer susceptibility to amplifier
instabilities also in presence of small non-idealities in the radiometric chain
components, provided that the gain modulation factor is estimated with an
accuracy of the order of 0.2%. These results have been recently confirmed by
experimental laboratory measurements conducted on the LFI prototype radiometers
at 30, 70 and 100 GHz.