sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Artal, E.

Normalized to: Artal, E.

17 article(s) in total. 471 co-authors, from 1 to 14 common article(s). Median position in authors list is 14,0.

[1]  oai:arXiv.org:1802.04594  [pdf] - 1634424
The QUIJOTE Experiment: Prospects for CMB B-MODE polarization detection and foregrounds characterization
Comments: 8 pages, 1 logo, 6 figures
Submitted: 2018-02-13
QUIJOTE (Q-U-I JOint TEnerife) is an experiment designed to achieve CMB B-mode polarization detection and sensitive enough to detect a primordial gravitational-wave component if the B-mode amplitude is larger than r = 0.05. It consists in two telescopes and three instruments observing in the frequency range 10-42 GHz installed at the Teide Observatory in the Canary Islands, Spain. The observing strategy includes three raster scan deep integration fields for cosmology, a nominal wide survey covering the Northen Sky and specific raster scan deep integration observations in regions of specific interest. The main goals of the project are presented and the first scientific results obtained with the first instrument are reviewed.
[2]  oai:arXiv.org:1706.04516  [pdf] - 1935364
Exploring Cosmic Origins with CORE: Survey requirements and mission design
Delabrouille, J.; de Bernardis, P.; Bouchet, F. R.; Achúcarro, A.; Ade, P. A. R.; Allison, R.; Arroja, F.; Artal, E.; Ashdown, M.; Baccigalupi, C.; Ballardini, M.; Banday, A. J.; Banerji, R.; Barbosa, D.; Bartlett, J.; Bartolo, N.; Basak, S.; Baselmans, J. J. A.; Basu, K.; Battistelli, E. S.; Battye, R.; Baumann, D.; Benoît, A.; Bersanelli, M.; Bideaud, A.; Biesiada, M.; Bilicki, M.; Bonaldi, A.; Bonato, M.; Borrill, J.; Boulanger, F.; Brinckmann, T.; Brown, M. L.; Bucher, M.; Burigana, C.; Buzzelli, A.; Cabass, G.; Cai, Z. -Y.; Calvo, M.; Caputo, A.; Carvalho, C. -S.; Casas, F. J.; Castellano, G.; Catalano, A.; Challinor, A.; Charles, I.; Chluba, J.; Clements, D. L.; Clesse, S.; Colafrancesco, S.; Colantoni, I.; Contreras, D.; Coppolecchia, A.; Crook, M.; D'Alessandro, G.; D'Amico, G.; da Silva, A.; de Avillez, M.; de Gasperis, G.; De Petris, M.; de Zotti, G.; Danese, L.; Désert, F. -X.; Desjacques, V.; Di Valentino, E.; Dickinson, C.; Diego, J. M.; Doyle, S.; Durrer, R.; Dvorkin, C.; Eriksen, H. -K.; Errard, J.; Feeney, S.; Fernández-Cobos, R.; Finelli, F.; Forastieri, F.; Franceschet, C.; Fuskeland, U.; Galli, S.; Génova-Santos, R. T.; Gerbino, M.; Giusarma, E.; Gomez, A.; González-Nuevo, J.; Grandis, S.; Greenslade, J.; Goupy, J.; Hagstotz, S.; Hanany, S.; Handley, W.; Henrot-Versillé, S.; Hernández-Monteagudo, C.; Hervias-Caimapo, C.; Hills, M.; Hindmarsh, M.; Hivon, E.; Hoang, D. T.; Hooper, D. C.; Hu, B.; Keihänen, E.; Keskitalo, R.; Kiiveri, K.; Kisner, T.; Kitching, T.; Kunz, M.; Kurki-Suonio, H.; Lagache, G.; Lamagna, L.; Lapi, A.; Lasenby, A.; Lattanzi, M.; Brun, A. M. C. Le; Lesgourgues, J.; Liguori, M.; Lindholm, V.; Lizarraga, J.; Luzzi, G.; Macìas-Pérez, J. F.; Maffei, B.; Mandolesi, N.; Martin, S.; Martinez-Gonzalez, E.; Martins, C. J. A. P.; Masi, S.; Massardi, M.; Matarrese, S.; Mazzotta, P.; McCarthy, D.; Melchiorri, A.; Melin, J. -B.; Mennella, A.; Mohr, J.; Molinari, D.; Monfardini, A.; Montier, L.; Natoli, P.; Negrello, M.; Notari, A.; Noviello, F.; Oppizzi, F.; O'Sullivan, C.; Pagano, L.; Paiella, A.; Pajer, E.; Paoletti, D.; Paradiso, S.; Partridge, R. B.; Patanchon, G.; Patil, S. P.; Perdereau, O.; Piacentini, F.; Piat, M.; Pisano, G.; Polastri, L.; Polenta, G.; Pollo, A.; Ponthieu, N.; Poulin, V.; Prêle, D.; Quartin, M.; Ravenni, A.; Remazeilles, M.; Renzi, A.; Ringeval, C.; Roest, D.; Roman, M.; Roukema, B. F.; Rubino-Martin, J. -A.; Salvati, L.; Scott, D.; Serjeant, S.; Signorelli, G.; Starobinsky, A. A.; Sunyaev, R.; Tan, C. Y.; Tartari, A.; Tasinato, G.; Toffolatti, L.; Tomasi, M.; Torrado, J.; Tramonte, D.; Trappe, N.; Triqueneaux, S.; Tristram, M.; Trombetti, T.; Tucci, M.; Tucker, C.; Urrestilla, J.; Väliviita, J.; Van de Weygaert, R.; Van Tent, B.; Vennin, V.; Verde, L.; Vermeulen, G.; Vielva, P.; Vittorio, N.; Voisin, F.; Wallis, C.; Wandelt, B.; Wehus, I.; Weller, J.; Young, K.; Zannoni, M.
Comments: 79 pages, 14 figures
Submitted: 2017-06-14
Future observations of cosmic microwave background (CMB) polarisation have the potential to answer some of the most fundamental questions of modern physics and cosmology. In this paper, we list the requirements for a future CMB polarisation survey addressing these scientific objectives, and discuss the design drivers of the CORE space mission proposed to ESA in answer to the "M5" call for a medium-sized mission. The rationale and options, and the methodologies used to assess the mission's performance, are of interest to other future CMB mission design studies. CORE is designed as a near-ultimate CMB polarisation mission which, for optimal complementarity with ground-based observations, will perform the observations that are known to be essential to CMB polarisation scienceand cannot be obtained by any other means than a dedicated space mission.
[3]  oai:arXiv.org:1605.04741  [pdf] - 1494692
QUIJOTE Scientific Results. II. Polarisation Measurements of the Microwave Emission in the Galactic molecular complexes W43 and W47 and supernova remnant W44
Comments: Accepted for publication in MNRAS
Submitted: 2016-05-16, last modified: 2016-09-28
We present Q-U-I JOint TEnerife (QUIJOTE) intensity and polarisation maps at 10-20 GHz covering a region along the Galactic plane 24<l<45 deg, |b|<8 deg. These maps result from 210 h of data, have a sensitivity in polarisation of ~40 muK/beam and an angular resolution of ~1 deg. Our intensity data are crucial to confirm the presence of anomalous microwave emission (AME) towards the two molecular complexes W43 (22 sigma) and W47 (8 sigma). We also detect at high significance (6 sigma) AME associated with W44, the first clear detection of this emission towards a SNR. The new QUIJOTE polarisation data, in combination with WMAP, are essential to: i) Determine the spectral index of the synchrotron emission in W44, beta_sync =-0.62 +/-0.03, in good agreement with the value inferred from the intensity spectrum once a free-free component is included in the fit. ii) Trace the change in the polarisation angle associated with Faraday rotation in the direction of W44 with rotation measure -404 +/- 49 rad/m2. And iii) set upper limits on the polarisation of W43 of Pi_AME <0.39 per cent (95 per cent C.L.) from QUIJOTE 17~GHz, and <0.22 per cent from WMAP 41 GHz data, which are the most stringent constraints ever obtained on the polarisation fraction of the AME. For typical physical conditions (grain temperature and magnetic field strengths), and in the case of perfect alignment between the grains and the magnetic field, the models of electric or magnetic dipole emissions predict higher polarisation fractions.
[4]  oai:arXiv.org:1504.03514  [pdf] - 979173
The QUIJOTE experiment: project overview and first results
Comments: To appear in "Highlights of Spanish Astrophysics VIII", Proceedings of the XI Scientific Meeting of the Spanish Astronomical Society, Teruel, Spain (2014)
Submitted: 2015-04-14
QUIJOTE (Q-U-I JOint TEnerife) is a new polarimeter aimed to characterize the polarization of the Cosmic Microwave Background and other Galactic and extragalactic signals at medium and large angular scales in the frequency range 10-40 GHz. The multi-frequency (10-20~GHz) instrument, mounted on the first QUIJOTE telescope, saw first light on November 2012 from the Teide Observatory (2400~m a.s.l). During 2014 the second telescope has been installed at this observatory. A second instrument at 30~GHz will be ready for commissioning at this telescope during summer 2015, and a third additional instrument at 40~GHz is now being developed. These instruments will have nominal sensitivities to detect the B-mode polarization due to the primordial gravitational-wave component if the tensor-to-scalar ratio is larger than r=0.05.
[5]  oai:arXiv.org:1401.4690  [pdf] - 780687
The QUIJOTE CMB Experiment: status and first results with the multi-frequency instrument
Comments: Rencontres du Vietnam 2013: Cosmology in the Planck Era. Conference Proceedings. Typos added
Submitted: 2014-01-19, last modified: 2014-02-05
The QUIJOTE (Q-U-I JOint Tenerife) CMB Experiment is designed to observe the polarization of the Cosmic Microwave Background and other Galactic and extragalactic signals at medium and large angular scales in the frequency range of 10-40 GHz. The first of the two QUIJOTE telescopes and the multi-frequency (10-20 GHz) instrument have been in operation since November 2012. In 2014 a second telescope and a new instrument at 30GHz will be ready for commissioning, and an additional instrument at 40 GHz is in its final design stages. After three years of effective observations, the data obtained by these telescopes and instruments will have the required sensitivity to detect a primordial gravitational-wave component if the tensor-to-scalar ratio is larger than r = 0.05. At the moment, we have completed half of the wide Galactic survey with the multi-frequency instrument covering 18 000 square degrees of the Northern hemisphere. When we finish this survey in early 2014, we shall have reached approximately 14{\mu}K per one degree beam at 11, 13, 17 and 19 GHz, in both Q and U.
[6]  oai:arXiv.org:1101.2038  [pdf] - 955981
Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance
Mennella, A.; Bersanelli, M.; Butler, R. C.; Curto, A.; Cuttaia, F.; Davis, R. J.; Dick, J.; Frailis, M.; Galeotta, S.; Gregorio, A.; Kurki-Suonio, H.; Lawrence, C. R.; Leach, S.; Leahy, J. P.; Lowe, S.; Maino, D.; Mandolesi, N.; Maris, M.; Martínez-González, E.; Meinhold, P. R.; Morgante, G.; Pearson, D.; Perrotta, F.; Polenta, G.; Poutanen, T.; Sandri, M.; Seiffert, M. D.; Suur-Uski, A. -S.; Tavagnacco, D.; Terenzi, L.; Tomasi, M.; Valiviita, J.; Villa, F.; Watson, R.; Wilkinson, A.; Zacchei, A.; Zonca, A.; Aja, B.; Artal, E.; Baccigalupi, C.; Banday, A. J.; Barreiro, R. B.; Bartlett, J. G.; Bartolo, N.; Battaglia, P.; Bennett, K.; Bonaldi, A.; Bonavera, L.; Borrill, J.; Bouchet, F. R.; Burigana, C.; Cabella, P.; Cappellini, B.; Chen, X.; Colombo, L.; Cruz, M.; Danese, L.; D'Arcangelo, O.; Davies, R. D.; de Gasperis, G.; de Rosa, A.; de Zotti, G.; Dickinson, C.; Diego, J. M.; Donzelli, S.; Efstathiou, G.; Enßlin, T. A.; Eriksen, H. K.; Falvella, M. C.; Finelli, F.; Foley, S.; Franceschet, C.; Franceschi, E.; Gaier, T. C.; Génova-Santos, R. T.; George, D.; Gómez, F.; González-Nuevo, J.; Górski, K. M.; Gruppuso, A.; Hansen, F. K.; Herranz, D.; Herreros, J. M.; Hoyland, R. J.; Hughes, N.; Jewell, J.; Jukkala, P.; Juvela, M.; Kangaslahti, P.; Keihänen, E.; Keskitalo, R.; Kilpia, V. -H.; Kisner, T. S.; Knoche, J.; Knox, L.; Laaninen, M.; Lähteenmäki, A.; Lamarre, J. -M.; Leonardi, R.; León-Tavares, J.; Leutenegger, P.; Lilje, P. B.; López-Caniego, M.; Lubin, P. M.; Malaspina, M.; Marinucci, D.; Massardi, M.; Matarrese, S.; Matthai, F.; Melchiorri, A.; Mendes, L.; Miccolis, M.; Migliaccio, M.; Mitra, S.; Moss, A.; Natoli, P.; Nesti, R.; Nørgaard-Nielsen, H. U.; Pagano, L.; Paladini, R.; Paoletti, D.; Partridge, B.; Pasian, F.; Pettorino, V.; Pietrobon, D.; Pospieszalski, M.; Prézeau, G.; Prina, M.; Procopio, P.; Puget, J. -L.; Quercellini, C.; Rachen, J. P.; Rebolo, R.; Reinecke, M.; Ricciardi, S.; Robbers, G.; Rocha, G.; Roddis, N.; Rubiño-Martín, J. A.; Savelainen, M.; Scott, D.; Silvestri, R.; Simonetto, A.; Sjoman, P.; Smoot, G. F.; Sozzi, C.; Stringhetti, L.; Tauber, J. A.; Tofani, G.; Toffolatti, L.; Tuovinen, J.; Türler, M.; Umana, G.; Valenziano, L.; Varis, J.; Vielva, P.; Vittorio, N.; Wade, L. A.; Watson, C.; White, S. D. M.; Winder, F.
Comments: Published version
Submitted: 2011-01-11, last modified: 2011-12-19
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used to obtain them from the flight data and provide a comparison with pre-launch ground assessments, which are essentially confirmed in flight.
[7]  oai:arXiv.org:1005.2541  [pdf] - 1032478
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
Comments: 15 pages, 18 figures. Accepted for publication in Astronomy and Astrophysics
Submitted: 2010-05-14
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.
[8]  oai:arXiv.org:1001.4771  [pdf] - 33190
LFI 30 and 44 GHz receivers Back-End Modules
Comments:
Submitted: 2010-01-26, last modified: 2010-01-27
The 30 and 44 GHz Back End Modules (BEM) for the Planck Low Frequency Instrument are broadband receivers (20% relative bandwidth) working at room temperature. The signals coming from the Front End Module are amplified, band pass filtered and finally converted to DC by a detector diode. Each receiver has two identical branches following the differential scheme of the Planck radiometers. The BEM design is based on MMIC Low Noise Amplifiers using GaAs P-HEMT devices, microstrip filters and Schottky diode detectors. Their manufacturing development has included elegant breadboard prototypes and finally qualification and flight model units. Electrical, mechanical and environmental tests were carried out for the characterization and verification of the manufactured BEMs. A description of the 30 and 44 GHz Back End Modules of Planck-LFI radiometers is given, with details of the tests done to determine their electrical and environmental performances. The electrical performances of the 30 and 44 GHz Back End Modules: frequency response, effective bandwidth, equivalent noise temperature, 1/f noise and linearity are presented.
[9]  oai:arXiv.org:1001.4610  [pdf] - 33148
The linearity response of the Planck-LFI flight model receivers
Comments: this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst; This is an author-created, un-copyedited version of an article accepted for publication in JINST. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher authenticated version is available online at 10.1088/1748-0221/4/12/T12011.
Submitted: 2010-01-26
In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article we discuss the various sources of compression and present a model that accurately describes data measured during tests performed with individual radiomeric chains. After discussing test results we present the best parameter set representing the receiver response and discuss the impact of non linearity on in-flight calibration, which is shown to be negligible.
[10]  oai:arXiv.org:1001.4589  [pdf] - 33143
Planck-LFI radiometers' spectral response
Comments: 16 pages, 9 figures, this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst
Submitted: 2010-01-26
The Low Frequency Instrument (LFI) is an array of pseudo-correlation radiometers on board the Planck satellite, the ESA mission dedicated to precision measurements of the Cosmic Microwave Background. The LFI covers three bands centred at 30, 44 and 70 GHz, with a goal bandwidth of 20% of the central frequency. The characterization of the broadband frequency response of each radiometer is necessary to understand and correct for systematic effects, particularly those related to foreground residuals and polarization measurements. In this paper we present the measured band shape of all the LFI channels and discuss the methods adopted for their estimation. The spectral characterization of each radiometer was obtained by combining the measured spectral response of individual units through a dedicated RF model of the LFI receiver scheme. As a consistency check, we also attempted end-to-end spectral measurements of the integrated radiometer chain in a cryogenic chamber. However, due to systematic effects in the measurement setup, only qualitative results were obtained from these tests. The measured LFI bandpasses exhibit a moderate level of ripple, compatible with the instrument scientific requirements.
[11]  oai:arXiv.org:1001.4608  [pdf] - 33147
Noise Properties of the Planck-LFI Receivers
Comments: this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst
Submitted: 2010-01-26
The Planck Low Frequency Instrument (LFI) radiometers have been tested extensively during several dedicated campaigns. The present paper reports the principal noise properties of the LFI radiometers.
[12]  oai:arXiv.org:1001.4743  [pdf] - 33184
Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument
Comments: 39 pages, 33 figures (33 EPS files), 12 tables. Planck LFI technical papers published by JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221
Submitted: 2010-01-26
We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launched in 2009. The scientific requirements of the mission determine the performance parameters to be met by the FEMs, including their linear polarization characteristics. The FEM design is that of a differential pseudo-correlation radiometer in which the signal from the sky is compared with a 4-K blackbody load. The Low Noise Amplifier (LNA) at the heart of the FEM is based on indium phosphide High Electron Mobility Transistors (HEMTs). The radiometer incorporates a novel phase-switch design which gives excellent amplitude and phase match across the band. The noise temperature requirements are met within the measurement errors at the two frequencies. For the most sensitive LNAs, the noise temperature at the band centre is 3 and 5 times the quantum limit at 30 and 44 GHz respectively. For some of the FEMs, the noise temperature is still falling as the ambient temperature is reduced to 20 K. Stability tests of the FEMs, including a measurement of the 1/f knee frequency, also meet mission requirements. The 30 and 44 GHz FEMs have met or bettered the mission requirements in all critical aspects. The most sensitive LNAs have reached new limits of noise temperature for HEMTs at their band centres. The FEMs have well-defined linear polarization characteristcs.
[13]  oai:arXiv.org:1001.4562  [pdf] - 1024812
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
Comments: Accepted for publications in Astronomy and Astrophysics. Astronomy & Astrophysics, 2010 (acceptance date: 12 Jan 2010)
Submitted: 2010-01-25
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.
[14]  oai:arXiv.org:1001.3321  [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency Instrument
Bersanelli, M.; Mandolesi, N.; Butler, R. C.; Mennella, A.; Villa, F.; Aja, B.; Artal, E.; Artina, E.; Baccigalupi, C.; Balasini, M.; Baldan, G.; Banday, A.; Bastia, P.; Battaglia, P.; Bernardino, T.; Blackhurst, E.; Boschini, L.; Burigana, C.; Cafagna, G.; Cappellini, B.; Cavaliere, F.; Colombo, F.; Crone, G.; Cuttaia, F.; D'Arcangelo, O.; Danese, L.; Davies, R. D.; Davis, R. J.; De Angelis, L.; De Gasperis, G. C.; De La Fuente, L.; De Rosa, A.; De Zotti, G.; Falvella, M. C.; Ferrari, F.; Ferretti, R.; Figini, L.; Fogliani, S.; Franceschet, C.; Franceschi, E.; Gaier, T.; Garavaglia, S.; Gomez, F.; Gorski, K.; Gregorio, A.; Guzzi, P.; Herreros, J. M.; Hildebrandt, S. R.; Hoyland, R.; Hughes, N.; Janssen, M.; Jukkala, P.; Kettle, D.; Kilpia, V. H.; Laaninen, M.; Lapolla, P. M.; Lawrence, C. R.; Leahy, J. P.; Leonardi, R.; Leutenegger, P.; Levin, S.; Lilje, P. B.; Lowe, S. R.; Lubin, D. Lawson P. M.; Maino, D.; Malaspina, M.; Maris, M.; Marti-Canales, J.; Martinez-Gonzalez, E.; Mediavilla, A.; Meinhold, P.; Miccolis, M.; Morgante, G.; Natoli, P.; Nesti, R.; Pagan, L.; Paine, C.; Partridge, B.; Pascual, J. P.; Pasian, F.; Pearson, D.; Pecora, M.; Perrotta, F.; Platania, P.; Pospieszalski, M.; Poutanen, T.; Prina, M.; Rebolo, R.; Roddis, N.; Rubino-Martin, J. A.; Salmon, n M. J.; Sandri, M.; Seiffert, M.; Silvestri, R.; Simonetto, A.; Sjoman, P.; Smoot, G. F.; Sozzi, C.; Stringhetti, L.; Taddei, E.; Tauber, J.; Terenzi, L.; Tomasi, M.; Tuovinen, J.; Valenziano, L.; Varis, J.; Vittorio, N.; Wade, L. A.; Wilkinson, A.; Winder, F.; Zacchei, A.; Zonca, A.
Comments: 23 pages, 31 figures, accepted by Astronomy and Astrophysics, Planck LFI technical papers published by JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.
[15]  oai:arXiv.org:1001.2657  [pdf] - 1024642
Planck pre-launch status: the Planck-LFI programme
Mandolesi, N.; Bersanelli, M.; Butler, R. C.; Artal, E.; Baccigalupi, C.; Balbi, A.; Banday, A. J.; Barreiro, R. B.; Bartelmann, M.; Bennett, K.; Bhandari, P.; Bonaldi, A.; Borrill, J.; Bremer, M.; Burigana, C.; Bowman, R. C.; Cabella, P.; Cantalupo, C.; Cappellini, B.; Courvoisier, T.; Crone, G.; Cuttaia, F.; Danese, L.; D'Arcangelo, O.; Davies, R. D.; Davis, R. J.; De Angelis, L.; de Gasperis, G.; De Rosa, A.; De Troia, G.; de Zotti, G.; Dick, J.; Dickinson, C.; Diego, J. M.; Donzelli, S.; Dörl, U.; Dupac, X.; Enßlin, T. A.; Eriksen, H. K.; Falvella, M. C.; Finelli, F.; Frailis, M.; Franceschi, E.; Gaier, T.; Galeotta, S.; Gasparo, F.; Giardino, G.; Gomez, F.; Gonzalez-Nuevo, J.; Górski, K. M.; Gregorio, A.; Gruppuso, A.; Hansen, F.; Hell, R.; Herranz, D.; Herreros, J. M.; Hildebrandt, S.; Hovest, W.; Hoyland, R.; Huffenberger, K.; Janssen, M.; Jaffe, T.; Keihänen, E.; Keskitalo, R.; Kisner, T.; Kurki-Suonio, H.; Lähteenmäki, A.; Lawrence, C. R.; Leach, S. M.; Leahy, J. P.; Leonardi, R.; Levin, S.; Lilje, P. B.; López-Caniego, M.; Lowe, S. R.; Lubin, P. M.; Maino, D.; Malaspina, M.; Maris, M.; Marti-Canales, J.; Martinez-Gonzalez, E.; Massardi, M.; Matarrese, S.; Matthai, F.; Meinhold, P.; Melchiorri, A.; Mendes, L.; Mennella, A.; Morgante, G.; Morigi, G.; Morisset, N.; Moss, A.; Nash, A.; Natoli, P.; Nesti, R.; Paine, C.; Partridge, B.; Pasian, F.; Passvogel, T.; Pearson, D.; Pérez-Cuevas, L.; Perrotta, F.; Polenta, G.; Popa, L. A.; Poutanen, T.; Prezeau, G.; Prina, M.; Rachen, J. P.; Rebolo, R.; Reinecke, M.; Ricciardi, S.; Riller, T.; Rocha, G.; Roddis, N.; Rohlfs, R.; Rubiño-Martin, J. A.; Salerno, E.; Sandri, M.; Scott, D.; Seiffert, M.; Silk, J.; Simonetto, A.; Smoot, G. F.; Sozzi, C.; Sternberg, J.; Stivoli, F.; Stringhetti, L.; Tauber, J.; Terenzi, L.; Tomasi, M.; Tuovinen, J.; Türler, M.; Valenziano, L.; Varis, J.; Vielva, P.; Villa, F.; Vittorio, N.; Wade, L.; White, M.; White, S.; Wilkinson, A.; Zacchei, A.; Zonca, A.
Comments: 25 pages, 16 figures. In press on Astronomy and Astrophysics
Submitted: 2010-01-15
This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps of the microwave sky at frequencies in the range 27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation spectrum. The scientific goals are described, ranging from fundamental cosmology to Galactic and extragalactic astrophysics. The instrument design and development are outlined, together with the model philosophy and testing strategy. The instrument is presented in the context of the Planck mission. The LFI approach to ground and inflight calibration is described. We also describe the LFI ground segment. We present the results of a number of tests demonstrating the capability of the LFI data processing centre (DPC) to properly reduce and analyse LFI flight data, from telemetry information to calibrated and cleaned time ordered data, sky maps at each frequency (in temperature and polarization), component emission maps (CMB and diffuse foregrounds), catalogs for various classes of sources (the Early Release Compact Source Catalogue and the Final Compact Source Catalogue). The organization of the LFI consortium is briefly presented as well as the role of the core team in data analysis and scientific exploitation. All tests carried out on the LFI flight model demonstrate the excellent performance of the instrument and its various subunits. The data analysis pipeline has been tested and its main steps verified. In the first three months after launch, the commissioning, calibration, performance, and verification phases will be completed, after which Planck will begin its operational life, in which LFI will have an integral part.
[16]  oai:arXiv.org:0810.3141  [pdf] - 1000998
The Quijote CMB Experiment
Comments: 9 pages, 5 figures. To appear in "Highlights of Spanish Astrophysics V", Proceedings of the VIII Scientific Meeting of the Spanish Astronomical Society (SEA) held in Santander, 7-11 July, 2008. Edited by J. Gorgas, L. J. Goicoechea, J. I. Gonzalez-Serrano, J. M. Diego
Submitted: 2008-10-17
We present the current status of the QUIJOTE (Q-U-I JOint TEnerife) CMB Experiment, a new instrument which will start operations early 2009 at Teide Observatory, with the aim of characterizing the polarization of the CMB and other processes of galactic and extragalactic emission in the frequency range 10-30 GHz and at large angular scales. QUIJOTE will be a valuable complement at low frequencies for the PLANCK mission, and will have the required sensitivity to detect a primordial gravitational-wave component if the tensor-to-scalar ratio is larger than r=0.05.
[17]  oai:arXiv.org:astro-ph/0307116  [pdf] - 57829
Advanced pseudo-correlation radiometers for the Planck-LFI instrument
Comments: 6 pages, 3 figures
Submitted: 2003-07-07
The LFI (Low Frequency Instrument) on board the ESA Planck satellite is constituted by an array of radiometric detectors actively cooled at 20 K in the 30-70 GHz frequency range in the focal plane of the Planck telescope. In this paper we present an overview of the LFI instrument, with a particular focus on the radiometer design. The adopted pseudo-correlation scheme uses a software balancing technique (with a tunable parameter called gain modulation factor) which is effective in reducing the radiometer susceptibility to amplifier instabilities also in presence of small non-idealities in the radiometric chain components, provided that the gain modulation factor is estimated with an accuracy of the order of 0.2%. These results have been recently confirmed by experimental laboratory measurements conducted on the LFI prototype radiometers at 30, 70 and 100 GHz.