Normalized to: Arruda, L.
[1]
oai:arXiv.org:1006.2266 [pdf] - 188620
GAW - A very large field-of-view Imaging Atmospheric Cherenkov Telescope
Submitted: 2010-06-11
GAW (Gamma Air Watch) is a pathfinder experiment in the TeV range to test the
feasibility of a new generation of Imaging Atmospheric Cherenkov Telescopes
(IACT). It combines high flux sensitivity with large field-of-view (FoV=24deg x
24deg) using Fresnel lenses, stereoscopic observational approach and
single-photon counting mode. This particular counting mode, in comparison with
the usual charge integration one, allows the triggering of events with a
smaller number of collected Cherenkov photons keeping a good signal/background
separation. GAW is conceived as an array of three identical imaging telescopes
with 2.13 m diameter placed at the vertices of an equilateral triangle of 80 m
side. The telescope will be built at the Calar Alto Observatory site (Sierra de
Los Filabres - Almeria Spain, 2168 m a.s.l.) and is a joint effort of research
institutes in Italy, Portugal and Spain. The main characteristics of the
experiment will be reported.
[2]
oai:arXiv.org:0802.0110 [pdf] - 9662
Velocity and charge reconstruction with the AMS/RICH detector
Submitted: 2008-02-01
The Alpha Magnetic Spectrometer (AMS), to be installed on the International
Space Station (ISS) in 2008, will be equipped with a proximity focusing Ring
Imaging CHerenkov detector (RICH). This detector will be equipped with a dual
radiator (aerogel+NaF), a lateral conical mirror and a detection plane made of
680 photomultipliers and light-guides, enabling measurements of particle
electric charge and velocity. A likelihood method for the Cherenkov angle
reconstruction was applied leading to a velocity determination for protons with
a resolution around 0.1%. The electric charge reconstruction is based on the
counting of the number of photoelectrons and on an overall efficiency
estimation on an event-by-event basis. Results from the application of both
methods are presented.
[3]
oai:arXiv.org:0801.4957 [pdf] - 9635
AMS - a magnetic spectrometer on the international space station
Submitted: 2008-01-31
The Alpha Magnetic Spectrometer (AMS) is a particle detector, designed to
search for cosmic antimatter and dark matter and to study the elemental and
isotopic composition of primary cosmic rays, that will be installed on the
International Space Station (ISS) in 2008 to operate for at least three years.
The detector will be equipped with a ring imaging Cherenkov detector (RICH)
enabling measurements of particle electric charge and velocity with
unprecedented accuracy. Physics prospects and test beam results are shortly
presented.
[4]
oai:arXiv.org:0801.4952 [pdf] - 9632
Cosmic ray velocity and electric charge measurements with the AMS/RICH
detector: prototype results
Submitted: 2008-01-31
The Alpha Magnetic Spectrometer (AMS) to be installed on the International
Space Station (ISS) will measure charged cosmic ray spectra of elements up to
iron, in the rigidity range from 1 GV to 1 TV, for at least three years. AMS is
a large angular spectrometer composed of different subdetectors, including a
proximity focusing Ring Imaging CHerenkov (RICH) detector. This will be
equipped with a mixed radiator made of aerogel and sodium fluoride (NaF), a
lateral conical mirror and a detection plane made of 680 photomultipliers
coupled to light guides. The RICH detector allows measurements of particle's
electric charge up to iron, and particle's velocity. Two possible methods for
reconstructing the Cherenkov angle and the electric charge with the RICH will
be discussed.
A RICH prototype consisting of a detection matrix with 96 photomultipliers, a
segment of a conical mirror and samples of the radiator materials was built and
its performance was evaluated using ion beam data. Results from the last test
beam performed with ion fragments resulting from the collision of a 158
GeV/c/nucleon primary beam of indium ions (CERN SPS) on a lead target are
reported. The large amount of collected data allowed to test and characterize
different aerogel samples and the NaF radiator. In addition, the reflectivity
of the mirror was evaluated. The data analysis confirms the design goals.
[5]
oai:arXiv.org:0801.4656 [pdf] - 9559
Cosmic Ray Velocity and Electric Charge Measurements in the AMS
experiment
Submitted: 2008-01-30
The Alpha Magnetic Spectrometer (AMS) is a particle physics detector designed
to measure charged cosmic ray spectra with energies up to the TeV region and
with high energy photon detection capability up to few hundred GeV. It will be
installed on the International Space Station (ISS) in 2008 and will operate for
more than three years. Due to its large acceptance, the flight duration and the
state-of-art of particle identification techniques, AMS will have a remarkable
sensitivity on antimatter and dark matter searches. The addition of different
detector systems provide AMS with complementary and redundant electric charge
and velocity measurements. The velocity of singly charged particles is expected
to be measured with a precision of 0.1% and charge separation up to iron is
attainable. The AMS capability of measuring a large range of electric charges
and accurate velocities, will largely contribute to a better understanding of
cosmic ray production, acceleration and propagation mechanisms in the galaxy.
[6]
oai:arXiv.org:0801.4658 [pdf] - 9561
Isotopic mass separation with the RICH detector of the AMS Experiment
Submitted: 2008-01-30
The Alpha Magnetic Spectrometer (AMS) to be installed on the International
Space Station (ISS) will be equipped with a proximity focusing Ring Imaging
Cerenkov detector (RICH). Reconstruction of the Cerenkov angle and the electric
charge with RICH are discussed. A likelihood method for the Cerenkov angle
reconstruction was applied leading to a velocity determination for protons with
a resolution around 0.1%. The electric charge reconstruction is based on the
counting of the number of photoelectrons and on an overall efficiency
estimation on an event-by-event basis. The isotopic mass separation of helium
and beryllium is presented.
[7]
oai:arXiv.org:0801.4484 [pdf] - 268578
The Ring Imaging Cherenkov detector of the AMS experiment: test beam
results with a prototype
Submitted: 2008-01-29
The Alpha Magnetic Spectrometer (AMS) to be installed on the International
Space Station (ISS) will be equipped with a proximity Ring Imaging Cherenkov
(RICH) detector for measuring the velocity and electric charge of the charged
cosmic particles. This detector will contribute to the high level of redundancy
required for AMS as well as to the rejection of albedo particles. Charge
separation up to iron and a velocity resolution of the order of 0.1% for singly
charged particles are expected. A RICH protoptype consisting of a detection
matrix with 96 photomultiplier units, a segment of a conical mirror and samples
of the radiator materials was built and its performance was evaluated. Results
from the last test beam performed with ion fragments resulting from the
collision of a 158 GeV/c/nucleon primary beam of indium ions (CERN SPS) on a
lead target are reported. The large amount of collected data allowed to test
and characterize different aerogel samples and the sodium fluoride radiator. In
addition, the reflectivity of the mirror was evaluated. The data analysis
confirms the design goals.
[8]
oai:arXiv.org:0801.3250 [pdf] - 1579278
The RICH detector of the AMS-02 experiment: status and physics prospects
Pereira, Rui;
Aguilar-Benitez, M.;
Arruda, L.;
Barao, F.;
Baret, B.;
Barrau, A.;
Barreira, G.;
Belmont, E.;
Berdugo, J.;
Borges, J.;
Buenerd, M.;
Casadei, D.;
Casaus, J.;
Cortina, E.;
Costado, M.;
Crespo, D.;
Delgado, C.;
Diaz, C.;
Derome, L.;
Goncalves, P.;
Garcia-Lopez, R.;
de la Guia, C.;
Herrero, A.;
Lanciotti, E.;
Laurenti, G.;
Malinin, A.;
Mana, C.;
Marin, J.;
Mangin-Brinet, M.;
Martinez, G.;
Menchaca-Rocha, A.;
Palomares, C.;
Pimenta, M.;
Putze, A.;
Sallaz-Damaz, Y.;
Seo, E. S.;
Sevilla, I.;
Torrento, A.;
Vargas-Trevino, M.;
Veziant, O.
Submitted: 2008-01-21
The Alpha Magnetic Spectrometer (AMS), whose final version AMS-02 is to be
installed on the International Space Station (ISS) for at least 3 years, is a
detector designed to measure charged cosmic ray spectra with energies up to the
TeV region and with high energy photon detection capability up to a few hundred
GeV. It is equipped with several subsystems, one of which is a proximity
focusing RICH detector with a dual radiator (aerogel+NaF) that provides
reliable measurements for particle velocity and charge. The assembly and
testing of the AMS RICH is currently being finished and the full AMS detector
is expected to be ready by the end of 2008. The RICH detector of AMS-02 is
presented. Physics prospects are briefly discussed.
[9]
oai:arXiv.org:0801.3243 [pdf] - 9234
Particle identification with the AMS-02 RICH detector: D/p and
anti-D/anti-p separation
Submitted: 2008-01-21
The Alpha Magnetic Spectrometer (AMS), whose final version AMS-02 is to be
installed on the International Space Station (ISS) for at least 3 years, is a
detector designed to measure charged cosmic ray spectra with energies up to the
TeV region and with high energy photon detection capability up to a few hundred
GeV, using state-of-the art particle identification techniques. Among several
detector subsystems, AMS includes a proximity focusing RICH enabling precise
measurements of particle electric charge and velocity. The combination of both
these measurements together with the particle rigidity measured on the silicon
tracker endows a reliable measurement of the particle mass. The main topics of
the AMS-02 physics program include detailed measurements of the nuclear
component of the cosmic-ray spectrum and the search for indirect signatures of
dark matter. Mass separation of singly charged particles, and in particular the
separation of deuterons and antideuterons from massive backgrounds of protons
and antiprotons respectively, is essential in this context. Detailed Monte
Carlo simulations of AMS-02 have been used to evaluate the detector's
performance for mass separation at different energies. The obtained results and
physics prospects are presented.
[10]
oai:arXiv.org:0710.0993 [pdf] - 5676
Particle identification with the AMS-02 RICH detector: search for dark
matter with antideuterons
Submitted: 2007-10-04
The Alpha Magnetic Spectrometer (AMS), whose final version AMS-02 is to be
installed on the International Space Station (ISS) for at least 3 years, is a
detector designed to measure charged cosmic ray spectra with energies up to the
TeV region and with high energy photon detection capability up to a few hundred
GeV, using state-of-the art particle identification techniques. It is equipped
with several subsystems, one of which is a proximity focusing Ring Imaging
Cherenkov (RICH) detector equipped with a dual radiator (aerogel+NaF), a
lateral conical mirror and a detection plane made of 680 photomultipliers and
light guides, enabling precise measurements of particle electric charge and
velocity (Delta beta / beta ~ 10^-3 and 10^-4 for Z=1 and Z=10-20,
respectively) at kinetic energies of a few GeV/nucleon. Combining velocity
measurements with data on particle rigidity from the AMS-02 Tracker (Delta R /
R ~ 2% for R=1-10 GV) it is possible to obtain a reliable measurement for
particle mass. One of the main topics of the AMS-02 physics program is the
search for indirect signatures of dark matter. Experimental data indicate that
dark, non-baryonic matter of unknown composition is much more abundant than
baryonic matter, accounting for a large fraction of the energy content of the
Universe. Apart from antideuterons produced in cosmic-ray propagation, the
annihilation of dark matter will produce additional antideuteron fluxes.
Detailed Monte Carlo simulations of AMS-02 have been used to evaluate the
detector's performance for mass separation, a key issue for anti-D/anti-p
separation. Results of these studies are presented.
[11]
oai:arXiv.org:0710.0846 [pdf] - 1579258
Isotope separation with the RICH detector of the AMS Experiment
Submitted: 2007-10-03
The Alpha Magnetic Spectrometer (AMS), to be installed on the International
Space Station (ISS) in 2008, is a cosmic ray detector with several subsystems,
one of which is a proximity focusing Ring Imaging Cherenkov (RICH) detector.
This detector will be equipped with a dual radiator (aerogel+NaF), a lateral
conical mirror and a detection plane made of 680 photomultipliers and light
guides, enabling precise measurements of particle electric charge and velocity.
Combining velocity measurements with data on particle rigidity from the AMS
Tracker it is possible to obtain a measurement for particle mass, allowing the
separation of isotopes. A Monte Carlo simulation of the RICH detector, based on
realistic properties measured at ion beam tests, was performed to evaluate
isotope separation capabilities. Results for three elements -- H (Z=1), He
(Z=2) and Be (Z=4) -- are presented.
[12]
oai:arXiv.org:0709.2154 [pdf] - 4935
The AMS-RICH velocity and charge reconstruction
Barao, F.;
Aguilar-Benitez, M.;
Arruda, L.;
Baret, B.;
Barrau, A.;
Barreira, G.;
Belmont, E.;
Berdugo, J.;
Borges, J.;
Buenerd, M.;
Casadei, D.;
Casaus, J.;
Cortina, E.;
Costado, M.;
Crespo, D.;
Delgado, C.;
Diaz, C.;
Derome, L.;
Goncalves, P.;
Garcia-Lopez, R.;
de la Guia, C.;
Herrero, A.;
Lanciotti, E.;
Laurenti, G.;
Malinin, A.;
Mana, C.;
Marin, J.;
Mangin-Brinet, M.;
Martinez, G.;
Menchaca-Rocha, A.;
Palomares, C.;
Pereira, R.;
Pimenta, M.;
Putze, A.;
Sallaz-Damaz, Y.;
Seo, E. S.;
Sevilla, I.;
Torrento, A.;
Vargas-Trevino, M.;
Veziant, O.
Submitted: 2007-09-13
The AMS detector, to be installed on the International Space Station,
includes a Ring Imaging Cerenkov detector with two different radiators, silica
aerogel (n=1.05) and sodium fluoride (n=1.334). This detector is designed to
provide very precise measurements of velocity and electric charge in a wide
range of cosmic nuclei energies and atomic numbers. The detector geometry, in
particular the presence of a reflector for acceptance purposes, leads to
complex Cerenkov patterns detected in a pixelized photomultiplier matrix. The
results of different reconstruction methods applied to test beam data as well
as to simulated samples are presented. To ensure nominal performances
throughout the flight, several detector parameters have to be carefully
monitored. The algorithms developed to fulfill these requirements are
presented. The velocity and charge measurements provided by the RICH detector
endow the AMS spectrometer with precise particle identification capabilities in
a wide energy range. The expected performances on light isotope separation are
discussed.
[13]
oai:arXiv.org:astro-ph/0603852 [pdf] - 81061
The Ring Imaging Cherenkov detector (RICH) of the AMS experiment
Barao, F.;
Benitez, M. Aguilar;
Alcaraz, J.;
Arruda, L.;
Barrau, A.;
Barreira, G.;
Belmont, E.;
Berdugo, J.;
Brinet, M.;
Buenerd, M.;
Casadei, D.;
Casaus, J.;
Cortina, E.;
Delgado, C.;
Diaz, C.;
Derome, L.;
Eraud, L.;
Garcia-Lopez, R. J.;
Gallin-Martel, L.;
Giovacchini, F.;
Goncalves, P.;
Lanciotti, E.;
Laurenti, G.;
Malinine, A.;
Mana, C.;
Marin, J.;
Martinez, G.;
Menchaca-Rocha, A.;
Molla, M.;
Palomares, C.;
Panniello, M.;
Pereira, R.;
Pimenta, M.;
Protasov, K.;
Sanchez, E.;
Seo, E-S.;
Sevilla, N.;
Torrento, A.;
Vargas-Trevino, M.;
Veziant, O.
Submitted: 2006-03-31
The Alpha Magnetic Spectrometer (AMS) experiment to be installed on the
International Space Station (ISS) will be equipped with a proximity focusing
Ring Imaging Cherenkov (RICH) detector for measuring the electric charge and
velocity of the charged cosmic particles. A RICH prototype consisting of 96
photomultiplier units, including a piece of the conical reflector, was built
and its performance evaluated with ion beam data. Preliminary results of the
in-beam tests performed with ion fragments resulting from collisions of a 158
GeV/c/nuc primary beam of Indium ions (CERN SPS) on a Pb target are reported.
The collected data included tests to the final front-end electronics and to
different aerogel radiators. Cherenkov rings for a large range of charged
nuclei and with reflected photons were observed. The data analysis confirms the
design goals. Charge separation up to Fe and velocity resolution of the order
of 0.1% for singly charged particles are obtained.
[14]
oai:arXiv.org:astro-ph/0306224 [pdf] - 57305
The AMS-02 RICH Imager Prototype - In-Beam Tests with 20 GeV/c per
Nucleon Ions -
Buenerd, M.;
Aguayo, P.;
Benitez, M. Aguilar;
Arruda, L.;
Barao, F.;
Barrau, A.;
Baret, B.;
Belmont, E.;
Berdugo, J.;
Boudoul, G.;
Borges, J.;
Casadei, D.;
Casaus, J.;
Delgado, C.;
Diaz, C.;
Derome, L.;
Eraud, L.;
Gallin-Martel, L.;
Giovacchini, F.;
Goncalves, P.;
Lanciotti, E.;
Laurenti, G.;
Malinine, A.;
Mana, C.;
Marin, J.;
Martinez, G.;
Menchaca-Rocha, A.;
Palomares, C.;
Pimenta, M.;
Protasov, K.;
Sanchez, E.;
Seo, E-S.;
Sevilla, I.;
Torrento, A.;
Vargas-Trevino, M.
Submitted: 2003-06-11
A prototype of the AMS Cherenkov imager (RICH) has been tested at CERN by
means of a low intensity 20 GeV/c per nucleon ion beam obtained by
fragmentation of a primary beam of Pb ions. Data have been collected with a
single beam setting, over the range of nuclear charges 2<Z<~45 in various beam
conditions and using different radiators. The charge Z and velocity beta
resolutions have been measured.