Normalized to: Araujo-Hauck, C.
[1]
oai:arXiv.org:1208.1129 [pdf] - 1150535
Beating the confusion limit: The necessity of high angular resolution
for probing the physics of Sagittarius A* and its environment: Opportunities
for LINC-NIRVANA (LBT), GRAVITY (VLTI) and and METIS (E-ELT)
Eckart, A.;
Sabha, N.;
Witzel, G.;
Straubmeier, C.;
Shahzamanian, B.;
Valencia-S., M.;
Garcia-Marin, M.;
Horrobin, M.;
Moser, L.;
Zuther, J.;
Fischer, S.;
Rauch, C.;
Rost, S.;
Iserlohe, C.;
Yazici, S.;
Smajic, S.;
Wiest, M.;
Araujo-Hauck, C.;
Wank, I.
Submitted: 2012-08-06
The super-massive 4 million solar mass black hole (SMBH) SgrA* shows variable
emission from the millimeter to the X-ray domain. A detailed analysis of the
infrared light curves allows us to address the accretion phenomenon in a
statistical way. The analysis shows that the near-infrared flux density
excursions are dominated by a single state power law, with the low states of
SgrA* limited by confusion through the unresolved stellar background. We show
that for 8-10m class telescopes blending effects along the line of sight will
result in artificial compact star-like objects of 0.5-1 mJy that last for about
3-4 years. We discuss how the imaging capabilities of GRAVITY at the VLTI,
LINC-NIRVANA at the LBT and METIS at the E-ELT will contribute to the
investigation of the low variability states of SgrA*.
[2]
oai:arXiv.org:1007.1765 [pdf] - 1033617
The Fringe Detection Laser Metrology for the GRAVITY Interferometer at
the VLTI
Bartko, H.;
Gillessen, S.;
Rabien, S.;
Thiel, M.;
Gräter, A.;
Haug, M.;
Kellner, S.;
Eisenhauer, F.;
Lacour, S.;
Straubmeier, C.;
Berger, J. -P.;
Jocou, L.;
Chibani, W.;
Lüst, S.;
Moch, D.;
Pfuhl, O.;
Fabian, W.;
Araujo-Hauck, C.;
Perraut, K.;
Brandner, W.;
Perrin, G.;
Amorim, A.
Submitted: 2010-07-11
Interferometric measurements of optical path length differences of stars over
large baselines can deliver extremely accurate astrometric data. The
interferometer GRAVITY will simultaneously measure two objects in the field of
view of the Very Large Telescope Interferometer (VLTI) of the European Southern
Observatory (ESO) and determine their angular separation to a precision of 10
micro arcseconds in only 5 minutes. To perform the astrometric measurement with
such a high accuracy, the differential path length through the VLTI and the
instrument has to be measured (and tracked since Earth's rotation will
permanently change it) by a laser metrology to an even higher level of accuracy
(corresponding to 1 nm in 3 minutes). Usually, heterodyne differential path
techniques are used for nanometer precision measurements, but with these
methods it is difficult to track the full beam size and to follow the light
path up to the primary mirror of the telescope. Here, we present the
preliminary design of a differential path metrology system, developed within
the GRAVITY project. It measures the instrumental differential path over the
full pupil size and up to the entrance pupil location. The differential phase
is measured by detecting the laser fringe pattern both on the telescopes'
secondary mirrors as well as after reflection at the primary mirror. Based on
our proposed design we evaluate the phase measurement accuracy based on a full
budget of possible statistical and systematic errors. We show that this
metrology design fulfills the high precision requirement of GRAVITY.
[3]
oai:arXiv.org:1007.1612 [pdf] - 1033604
GRAVITY: a four-telescope beam combiner instrument for the VLTI
Gillessen, S.;
Eisenhauer, F.;
Perrin, G.;
Brandner, W.;
Straubmeier, C.;
Perraut, K.;
Amorim, A.;
Schöller, M.;
Araujo-Hauck, C.;
Bartko, H.;
Baumeister, H.;
Berger, J. -P.;
Carvas, P.;
Cassaing, F.;
Chapron, F.;
Choquet, E.;
Clenet, Y.;
Collin, C.;
Eckart, A.;
Fedou, P.;
Fischer, S.;
Gendron, E.;
Genzel, R.;
Gitton, P.;
Gonte, F.;
Gräter, A.;
Haguenauer, P.;
Haug, M.;
Haubois, X.;
Henning, T.;
Hippler, S.;
Hofmann, R.;
Jocou, L.;
Kellner, S.;
Kervella, P.;
Klein, R.;
Kudryavtseva, N.;
Lacour, S.;
Lapeyrere, V.;
Laun, W.;
Lena, P.;
Lenzen, R.;
Lima, J.;
Moch, D.;
Moratschke, D.;
Moulin, T.;
Naranjo, V.;
Neumann, U.;
Nolot, A.;
Paumard, T.;
Pfuhl, O.;
Rabien, S.;
Ramos, J.;
Rees, J. M.;
Rohloff, R. -R.;
Rouan, D.;
Rousset, G.;
Sevin, A.;
Thiel, M.;
Wagner, K.;
Wiest, M.;
Yazici, S.;
Ziegler, D.
Submitted: 2010-07-09
GRAVITY is an adaptive optics assisted Beam Combiner for the second
generation VLTI instrumentation. The instrument will provide high-precision
narrow-angle astrometry and phase-referenced interferometric imaging in the
astronomical K-band for faint objects. We describe the wide range of science
that will be tackled with this instrument, highlighting the unique capabilities
of the VLTI in combination with GRAVITY. The most prominent goal is to observe
highly relativistic motions of matter close to the event horizon of Sgr A*, the
massive black hole at center of the Milky Way. We present the preliminary
design that fulfils the requirements that follow from the key science drivers:
It includes an integrated optics, 4-telescope, dual feed beam combiner operated
in a cryogenic vessel; near-infrared wavefrontsensing adaptive optics;
fringe-tracking on secondary sources within the field of view of the VLTI and a
novel metrology concept. Simulations show that 10 {\mu}as astrometry within few
minutes is feasible for a source with a magnitude of mK = 15 like Sgr A*, given
the availability of suitable phase reference sources (mK = 10). Using the same
setup, imaging of mK = 18 stellar sources in the interferometric field of view
is possible, assuming a full night of observations and the corresponding UV
coverage of the VLTI.
[4]
oai:arXiv.org:0809.1663 [pdf] - 16147
Laser frequency combs for astronomical observations
Steinmetz, Tilo;
Wilken, Tobias;
Araujo-Hauck, Constanza;
Holzwarth, Ronald;
Hänsch, Theodor W.;
Pasquini, Luca;
Manescau, Antonio;
D'Odorico, Sandro;
Murphy, Michael T.;
Kentischer, Thomas;
Schmidt, Wolfgang;
Udem, Thomas
Submitted: 2008-09-09
A direct measurement of the universe's expansion history could be made by
observing in real time the evolution of the cosmological redshift of distant
objects. However, this would require measurements of Doppler velocity drifts of
about 1 centimeter per second per year, and astronomical spectrographs have not
yet been calibrated to this tolerance. We demonstrate the first use of a laser
frequency comb for wavelength calibration of an astronomical telescope. Even
with a simple analysis, absolute calibration is achieved with an equivalent
Doppler precision of approximately 9 meters per second at about 1.5 micrometers
- beyond state-of-the-art accuracy. We show that tracking complex, time-varying
systematic effects in the spectrograph and detector system is a particular
advantage of laser frequency comb calibration. This technique promises an
effective means for modeling and removal of such systematic effects to the
accuracy required by future experiments to see direct evidence of the
universe's putative acceleration.
[5]
oai:arXiv.org:astro-ph/0703622 [pdf] - 90431
High-precision wavelength calibration of astronomical spectrographs with
laser frequency combs
Murphy, M. T.;
Udem, Th.;
Holzwarth, R.;
Sizmann, A.;
Pasquini, L.;
Araujo-Hauck, C.;
Dekker, H.;
D'Odorico, S.;
Fischer, M.;
Hänsch, T. W.;
Manescau, A.
Submitted: 2007-03-23, last modified: 2007-06-28
We describe a possible new technique for precise wavelength calibration of
high-resolution astronomical spectrographs using femtosecond-pulsed mode-locked
lasers controlled by stable oscillators such as atomic clocks. Such `frequency
combs' provide a series of narrow modes which are uniformly spaced according to
the laser's pulse repetition rate and whose absolute frequencies are known a
priori with relative precision better than 10^{-12}. Simulations of frequency
comb spectra show that the photon-limited wavelength calibration precision
achievable with existing echelle spectrographs should be ~1 cm/s when
integrated over a 4000A range. Moreover, comb spectra may be used to accurately
characterise distortions of the wavelength scale introduced by the spectrograph
and detector system. The simulations show that frequency combs with pulse
repetition rates of 5-30GHz are required, given the typical resolving power of
existing and possible future echelle spectrographs. Achieving such high
repetition rates, together with the desire to produce all comb modes with
uniform intensity over the entire optical range, represent the only significant
challenges in the design of a practical system. Frequency comb systems may
remove wavelength calibration uncertainties from all practical spectroscopic
experiments, even those combining data from different telescopes over many
decades.