Normalized to: Araujo, G.
[1]
oai:arXiv.org:1902.04048 [pdf] - 1924972
Search for dark matter with a 231-day exposure of liquid argon using
DEAP-3600 at SNOLAB
Ajaj, R.;
Amaudruz, P. -A.;
Araujo, G. R.;
Baldwin, M.;
Batygov, M.;
Beltran, B.;
Bina, C. E.;
Bonatt, J.;
Boulay, M. G.;
Broerman, B.;
Bueno, J. F.;
Burghardt, P. M.;
Butcher, A.;
Cai, B.;
Cavuoti, S.;
Chen, M.;
Chen, Y.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
DiGioseffo, J.;
Doria, L.;
Duncan, F. A.;
Dunford, M.;
Erlandson, A.;
Fatemighomi, N.;
Fiorillo, G.;
Florian, S.;
Flower, A.;
Ford, R. J.;
Gagnon, R.;
Gallacher, D.;
Garcés, E. A.;
Garg, S.;
Giampa, P.;
Goeldi, D.;
Golovko, V. V.;
Gorel, P.;
Graham, K.;
Grant, D. R.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P. J.;
Hearns, C.;
Joy, A.;
Jillings, C. J.;
Kamaev, O.;
Kaur, G.;
Kemp, A.;
Kochanek, I.;
Kuźniak, M.;
Langrock, S.;
La Zia, F.;
Lehnert, B.;
Li, X.;
Lidgard, J.;
Lindner, T.;
Litvinov, O.;
Lock, J.;
Longo, G.;
Majewski, P.;
McDonald, A. B.;
McElroy, T.;
McGinn, T.;
McLaughlin, J. B.;
Mehdiyev, R.;
Mielnichuk, C.;
Monroe, J.;
Nadeau, P.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
O'Dwyer, E.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Piro, M. -C.;
Pollmann, T. R.;
Rand, E. T.;
Rethmeier, C.;
Retière, F.;
Seeburn, N.;
Singhrao, K.;
Skensved, P.;
Smith, B.;
Smith, N. J. T.;
Sonley, T.;
Soukup, J.;
Stainforth, R.;
Stone, C.;
Strickland, V.;
Sur, B.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Viel, S.;
Walding, J.;
Waqar, M.;
Ward, M.;
Westerdale, S.;
Willis, J.;
Zuñiga-Reyes, A.
Submitted: 2019-02-11, last modified: 2019-07-04
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter
experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The
detector consists of 3279 kg of LAr contained in a spherical acrylic vessel.
This paper reports on the analysis of a 758 tonne\cdot day exposure taken over
a period of 231 live-days during the first year of operation. No candidate
signal events are observed in the WIMP-search region of interest, which results
in the leading limit on the WIMP-nucleon spin-independent cross section on a
LAr target of $3.9\times10^{-45}$ cm$^{2}$ ($1.5\times10^{-44}$ cm$^{2}$) for a
100 GeV/c$^{2}$ (1 TeV/c$^{2}$) WIMP mass at 90\% C. L. In addition to a
detailed background model, this analysis demonstrates the best pulse-shape
discrimination in LAr at threshold, employs a Bayesian photoelectron-counting
technique to improve the energy resolution and discrimination efficiency, and
utilizes two position reconstruction algorithms based on PMT charge and photon
arrival times.
[2]
oai:arXiv.org:1905.03044 [pdf] - 1938412
Photoluminescence response of acrylic (PMMA) and polytetrafluoroethylene
(PTFE) to ultraviolet light
Submitted: 2019-05-08, last modified: 2019-05-20
Some publications indicate that poly(methyl methacrylate) (PMMA) and
polytetrafluoroethylene (PTFE) exhibit low levels of photoluminesence
(fluorescence and/or phosphorescence) when irradiated with photons in the
ultraviolet (UV) to visible range. PMMA (also known as acrylic) and PTFE are
commonly used to contain the liquid argon (LAr) or xenon (LXe) target material
in rare-event search experiments. LAr and LXe scintillate in the vacuum UV
region, and the PMMA and PTFE can be directly illuminated by these photons.
Photoluminescence from support materials could cause unexpected signals in
these detectors.
We investigate photoluminesence in the 400 nm to 550 nm region in response to
excitation with UV light between 130 nm and 250 nm at levels relevant to
rare-event search experiments. Measurements are done at room temperature and
the signal intensity is time-integrated over several minutes.
We tested PMMA and PTFE samples from the batches used in the DEAP-3600 and
LUX experiments and observed no photoluminescence signal. We put limits on the
efficiency of the plastics to shift UV photons to a wavelengths region of 400
nm to 550 nm at 0.05% to 0.35% relative to the wavelength shifting efficiency
of tetraphenyl-butadiene.
[3]
oai:arXiv.org:1905.05811 [pdf] - 1994027
Electromagnetic Backgrounds and Potassium-42 Activity in the DEAP-3600
Dark Matter Detector
Ajaj, R.;
Araujo, G. R.;
Batygov, M.;
Beltran, B.;
Bina, C. E.;
Boulay, M. G.;
Broerman, B.;
Bueno, J. F.;
Burghardt, P. M.;
Butcher, A.;
Cárdenas-Montes, M.;
Cavuoti, S.;
Chen, M.;
Chen, Y.;
Cleveland, B. T.;
Dering, K.;
Duncan, F. A.;
Dunford, M.;
Erlandson, A.;
Fatemighomi, N.;
Fiorillo, G.;
Flower, A.;
Ford, R. J.;
Gallacher, D.;
Abia, P. García;
Garg, S.;
Giampa, P.;
Goeldi, D.;
Golovko, V. V.;
Gorel, P.;
Graham, K.;
Grant, D. R.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P. J.;
Hearns, C.;
Joy, A.;
Jillings, C. J.;
Kamaev, O.;
Kaur, G.;
Kemp, A.;
Kochanek, I.;
Kuźniak, M.;
Langrock, S.;
La Zia, F.;
Lehnert, B.;
Li, X.;
Litvinov, O.;
Lock, J.;
Longo, G.;
Majewski, P.;
McDonald, A. B.;
McElroy, T.;
McGinn, T.;
McLaughlin, J. B.;
Mehdiyev, R.;
Mielnichuk, C.;
Monroe, J.;
Nadeau, P.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Pesudo, V.;
Piro, M. -C.;
Pollmann, T. R.;
Rand, E. T.;
Rethmeier, C.;
Retière, F.;
García, E. Sanchez;
Santorelli, R.;
Seeburn, N.;
Skensved, P.;
Smith, B.;
Smith, N. J. T.;
Sonley, T.;
Stainforth, R.;
Stone, C.;
Strickland, V.;
Sur, B.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Viel, S.;
Walding, J.;
Waqar, M.;
Ward, M.;
Westerdale, S.;
Willis, J.;
Zuñiga-Reyes, A.
Submitted: 2019-05-14
The DEAP-3600 experiment is searching for WIMP dark matter with a 3.3 tonne
single phase liquid argon (LAr) target, located 2.1 km underground at SNOLAB.
The experimental signature of dark matter interactions is keV-scale $^{40}$Ar
nuclear recoils (NR) producing 128 nm LAr scintillation photons observed by
PMTs. The largest backgrounds in DEAP-3600 are electronic recoils (ER) induced
by $\beta$ and $\gamma$-rays originating from internal and external
radioactivity in the detector material. A background model of the ER
interactions in DEAP-3600 was developed and is described in this work. The
model is based on several components which are expected from radioisotopes in
the LAr, from ex-situ material assay measurements, and from dedicated
independent in-situ analyses. This prior information is used in a Bayesian fit
of the ER components to a 247.2 d dataset to model the radioactivity in the
surrounding detector materials. While excellent discrimination between ERs and
NRs is reached with pulse shape discrimination, utilizing the large difference
between fast and slow components of LAr scintillation light, detailed knowledge
of the ER background and activity of detector components, sets valuable
constraints on other key types of backgrounds in the detector: neutrons and
alphas. In addition, the activity of $^{42}$Ar in LAr in DEAP-3600 is
determined by measuring the daughter decay of $^{42}$K. This cosmogenically
activated trace isotope is a relevant background at higher energies for other
rare event searches using atmospheric argon e.g. DarkSide-20k, GERDA or LEGEND.
The specific activity of $^{42}$Ar in the atmosphere is found to be $40.4 \pm
5.9$ $\mu$Bq/kg of argon.
[4]
oai:arXiv.org:1806.04020 [pdf] - 1858900
Polyethylene naphthalate film as a wavelength shifter in liquid argon
detectors
Submitted: 2018-06-11, last modified: 2019-03-15
Liquid argon-based scintillation detectors are important for dark matter
searches and neutrino physics. Argon scintillation light is in the vacuum
ultraviolet region, making it hard to be detected by conventional means.
Polyethylene naphthalate (PEN), an optically transparent thermoplastic
polyester commercially available as large area sheets or rolls, is proposed as
an alternative wavelength shifter to the commonly-used tetraphenyl butadiene
(TPB). By combining the existing literature data and spectrometer measurements
relative to TPB, we conclude that the fluorescence yield and timing of both
materials may be very close. The evidence collected suggests that PEN is a
suitable replacement for TPB in liquid argon neutrino detectors, and is also a
promising candidate for dark matter detectors. Advantages of PEN are discussed
in the context of scaling-up existing technologies to the next generation of
very large ktonne-scale detectors. Its simplicity has a potential to facilitate
such scale-ups, revolutionizing the field.
[5]
oai:arXiv.org:1802.07198 [pdf] - 1789406
DarkSide-50 532-day Dark Matter Search with Low-Radioactivity Argon
The DarkSide Collaboration;
Agnes, P.;
Albuquerque, I. F. M.;
Alexander, T.;
Alton, A. K.;
Araujo, G. R.;
Ave, M.;
Back, H. O.;
Baldin, B.;
Batignani, G.;
Biery, K.;
Bocci, V.;
Bonfini, G.;
Bonivento, W.;
Bottino, B.;
Budano, F.;
Bussino, S.;
Cadeddu, M.;
Cadoni, M.;
Calaprice, F.;
Caminata, A.;
Canci, N.;
Candela, A.;
Caravati, M.;
Cariello, M.;
Carlini, M.;
Carpinelli, M.;
Catalanotti, S.;
Cataudella, V.;
Cavalcante, P.;
Cavuoti, S.;
Chepurnov, A.;
Cicalò, C.;
Cocco, A. G.;
Covone, G.;
D'Angelo, D.;
D'Incecco, M.;
D'Urso, D.;
Davini, S.;
De Candia, A.;
De Cecco, S.;
De Deo, M.;
De Filippis, G.;
De Rosa, G.;
De Vincenzi, M.;
Derbin, A. V.;
Devoto, A.;
Di Eusanio, F.;
Di Pietro, G.;
Dionisi, C.;
Downing, M.;
Edkins, E.;
Empl, A.;
Fan, A.;
Fiorillo, G.;
Fitzpatrick, R. S.;
Fomenko, K.;
Franco, D.;
Gabriele, F.;
Galbiati, C.;
Ghiano, C.;
Giagu, S.;
Giganti, C.;
Giovanetti, G. K.;
Gorchakov, O.;
Goretti, A. M.;
Granato, F.;
Gromov, M.;
Guan, M.;
Guardincerri, Y.;
Gulino, M.;
Hackett, B. R.;
Herner, K.;
Hosseini, B.;
Hughes, D.;
Humble, P.;
Hungerford, E. V.;
Ianni, An.;
Ippolito, V.;
James, I.;
Johnson, T. N.;
Keeter, K.;
Kendziora, C. L.;
Kochanek, I.;
Koh, G.;
Korablev, D.;
Korga, G.;
Kubankin, A.;
Kuss, M.;
La Commara, M.;
Lai, M.;
Li, X.;
Lissia, M.;
Longo, G.;
Ma, Y.;
Machado, A. A.;
Machulin, I. N.;
Mandarano, A.;
Mapelli, L.;
Mari, S. M.;
Maricic, J.;
Martoff, C. J.;
Messina, A.;
Meyers, P. D.;
Milincic, R.;
Monte, A.;
Morrocchi, M.;
Mount, B. J.;
Muratova, V. N.;
Musico, P.;
Agasson, A. Navrer;
Nozdrina, A. O.;
Oleinik, A.;
Orsini, M.;
Ortica, F.;
Pagani, L.;
Pallavicini, M.;
Pandola, L.;
Pantic, E.;
Paoloni, E.;
Pelczar, K.;
Pelliccia, N.;
Pocar, A.;
Pordes, S.;
Poudel, S. S.;
Pugachev, D. A.;
Qian, H.;
Ragusa, F.;
Razeti, M.;
Razeto, A.;
Reinhold, B.;
Renshaw, A. L.;
Rescigno, M.;
Riffard, Q.;
Romani, A.;
Rossi, B.;
Rossi, N.;
Sablone, D.;
Samoylov, O.;
Sands, W.;
Sanfilippo, S.;
Savarese, C.;
Schlitzer, B.;
Segreto, E.;
Semenov, D. A.;
Shchagin, A.;
Sheshukov, A.;
Singh, P. N.;
Skorokhvatov, M. D.;
Smirnov, O.;
Sotnikov, A.;
Stanford, C.;
Stracka, S.;
Suvorov, Y.;
Tartaglia, R.;
Testera, G.;
Tonazzo, A.;
Trinchese, P.;
Unzhakov, E. V.;
Verducci, M.;
Vishneva, A.;
Vogelaar, B.;
Wada, M.;
Waldrop, T. J.;
Wang, H.;
Wang, Y.;
Watson, A. W.;
Westerdale, S.;
Wojcik, M. M.;
Xiang, X.;
Xiao, X.;
Yang, C.;
Ye, Z.;
Zhu, C.;
Zuzel, G.
Submitted: 2018-02-20, last modified: 2018-11-19
The DarkSide-50 direct-detection dark matter experiment is a dual-phase argon
time projection chamber operating at Laboratori Nazionali del Gran Sasso. This
paper reports on the blind analysis of a (16,660+-270) kg d exposure using a
target of low-radioactivity argon extracted from underground sources. We find
no events in the dark matter selection box and set a 90% C.L. upper limit on
the dark matter-nucleon spin-independent cross section of 1.14E-44 cm^2
(3.78E-44 cm^2, 3.43E-43 cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2, 10
TeV/c^2).
[7]
oai:arXiv.org:1802.06994 [pdf] - 1739878
Low-Mass Dark Matter Search with the DarkSide-50 Experiment
The DarkSide Collaboration;
Agnes, P.;
Albuquerque, I. F. M.;
Alexander, T.;
Alton, A. K.;
Araujo, G. R.;
Asner, D. M.;
Ave, M.;
Back, H. O.;
Baldin, B.;
Batignani, G.;
Biery, K.;
Bocci, V.;
Bonfini, G.;
Bonivento, W.;
Bottino, B.;
Budano, F.;
Bussino, S.;
Cadeddu, M.;
Cadoni, M.;
Calaprice, F.;
Caminata, A.;
Canci, N.;
Candela, A.;
Caravati, M.;
Cariello, M.;
Carlini, M.;
Carpinelli, M.;
Catalanotti, S.;
Cataudella, V.;
Cavalcante, P.;
Cavuoti, S.;
Cereseto, R.;
Chepurnov, A.;
Cicalò, C.;
Cifarelli, L.;
Cocco, A. G.;
Covone, G.;
D'Angelo, D.;
D'Incecco, M.;
D'Urso, D.;
Davini, S.;
De Candia, A.;
De Cecco, S.;
De Deo, M.;
De Filippis, G.;
De Rosa, G.;
De Vincenzi, M.;
Demontis, P.;
Derbin, A. V.;
Devoto, A.;
Di Eusanio, F.;
Di Pietro, G.;
Dionisi, C.;
Downing, M.;
Edkins, E.;
Empl, A.;
Fan, A.;
Fiorillo, G.;
Fomenko, K.;
Franco, D.;
Gabriele, F.;
Gabrieli, A.;
Galbiati, C.;
Abia, P. Garcia;
Ghiano, C.;
Giagu, S.;
Giganti, C.;
Giovanetti, G. K.;
Gorchakov, O.;
Goretti, A. M.;
Granato, F.;
Gromov, M.;
Guan, M.;
Guardincerri, Y.;
Gulino, M.;
Hackett, B. R.;
Hassanshahi, M. H.;
Herner, K.;
Hosseini, B.;
Hughes, D.;
Humble, P.;
Hungerford, E. V.;
Ianni, Al.;
Ianni, An.;
Ippolito, V.;
James, I.;
Johnson, T. N.;
Kahn, Y.;
Keeter, K.;
Kendziora, C. L.;
Kochanek, I.;
Koh, G.;
Korablev, D.;
Korga, G.;
Kubankin, A.;
Kuss, M.;
La Commara, M.;
Lai, M.;
Li, X.;
Lisanti, M.;
Lissia, M.;
Loer, B.;
Longo, G.;
Ma, Y.;
Machado, A. A.;
Machulin, I. N.;
Mandarano, A.;
Mapelli, L.;
Mari, S. M.;
Maricic, J.;
Martoff, C. J.;
Messina, A.;
Meyers, P. D.;
Milincic, R.;
Mishra-Sharma, S.;
Monte, A.;
Morrocchi, M.;
Mount, B. J.;
Muratova, V. N.;
Musico, P.;
Nania, R.;
Agasson, A. Navrer;
Nozdrina, A. O.;
Oleinik, A.;
Orsini, M.;
Ortica, F.;
Pagani, L.;
Pallavicini, M.;
Pandola, L.;
Pantic, E.;
Paoloni, E.;
Pazzona, F.;
Pelczar, K.;
Pelliccia, N.;
Pesudo, V.;
Pocar, A.;
Pordes, S.;
Poudel, S. S.;
Pugachev, D. A.;
Qian, H.;
Ragusa, F.;
Razeti, M.;
Razeto, A.;
Reinhold, B.;
Renshaw, A. L.;
Rescigno, M.;
Riffard, Q.;
Romani, A.;
Rossi, B.;
Rossi, N.;
Sablone, D.;
Samoylov, O.;
Sands, W.;
Sanfilippo, S.;
Sant, M.;
Santorelli, R.;
Savarese, C.;
Scapparone, E.;
Schlitzer, B.;
Segreto, E.;
Semenov, D. A.;
Shchagin, A.;
Sheshukov, A.;
Singh, P. N.;
Skorokhvatov, M. D.;
Smirnov, O.;
Sotnikov, A.;
Stanford, C.;
Stracka, S.;
Suffritti, G. B.;
Suvorov, Y.;
Tartaglia, R.;
Testera, G.;
Tonazzo, A.;
Trinchese, P.;
Unzhakov, E. V.;
Verducci, M.;
Vishneva, A.;
Vogelaar, B.;
Wada, M.;
Waldrop, T. J.;
Wang, H.;
Wang, Y.;
Watson, A. W.;
Westerdale, S.;
Wojcik, M. M.;
Wojcik, M.;
Xiang, X.;
Xiao, X.;
Yang, C.;
Ye, Z.;
Zhu, C.;
Zichichi, A.;
Zuzel, G.
Submitted: 2018-02-20, last modified: 2018-08-28
We present the results of a search for dark matter WIMPs in the mass range
below 20 GeV/c^2 using a target of low-radioactivity argon. The data were
obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso
(LNGS). The analysis is based on the ionization signal, for which the
DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The
observed rate in the detector at 0.5 keVee is about 1.5 events/keVee/kg/day and
is almost entirely accounted for by known background sources. We obtain a 90%
C.L. exclusion limit above 1.8 GeV/c^2 for the spin-independent cross section
of dark matter WIMPs on nucleons, extending the exclusion region for dark
matter below previous limits in the range 1.8-6 GeV/c^2.