Normalized to: Andritschke, R.
[1]
oai:arXiv.org:1310.4848 [pdf] - 734731
ROAn, a ROOT based Analysis Framework
Submitted: 2013-10-17
The ROOT based Offline and Online Analysis (ROAn) framework was developed to
perform data analysis on data from Depleted P-channel Field Effect Transistor
(DePFET) detectors, a type of active pixel sensors developed at the MPI
Halbleiterlabor (HLL). ROAn is highly flexible and extensible, thanks to ROOT's
features like run-time type information and reflection. ROAn provides an
analysis program which allows to perform configurable step-by-step analysis on
arbitrary data, an associated suite of algorithms focused on DePFET data
analysis, and a viewer program for displaying and processing online or offline
detector data streams. The analysis program encapsulates the applied algorithms
in objects called steps which produce analysis results. The dependency between
results and thus the order of calculation is resolved automatically by the
program. To optimize algorithms for studying detector effects, analysis
parameters are often changed. Such changes of input parameters are detected in
subsequent analysis runs and only the necessary recalculations are triggered.
This saves time and simultaneously keeps the results consistent. The viewer
program offers a configurable Graphical User Interface (GUI) and process chain,
which allows the user to adapt the program to different tasks such as offline
viewing of file data, online monitoring of running detector systems, or
performing online data analysis (histogramming, calibration, etc.). Because of
its modular design, ROAn can be extended easily, e.g. be adapted to new
detector types and analysis processes.
[2]
oai:arXiv.org:1308.6785 [pdf] - 713385
The Hot and Energetic Universe: The Wide Field Imager (WFI) for Athena+
Rau, A.;
Meidinger, N.;
Nandra, K.;
Porro, M.;
Barret, D.;
Santangelo, A.;
Schmid, C.;
Struder, L.;
Tenzer, C.;
Wilms, J.;
Amoros, C.;
Andritschke, R.;
Aschauer, F.;
Bahr, A.;
Gunther, B.;
Furmetz, M.;
Ott, B.;
Perinati, E.;
Rambaud, D.;
Reiffers, J.;
Treis, J.;
von Kienlin, A.;
Weidenspointner, G.
Submitted: 2013-08-30
The Wide Field Imager (WFI) is one of the two scientific instruments proposed
for the Athena+ X-ray observatory. It will provide imaging in the 0.1-15 keV
band over a wide field, simultaneously with spectrally and time-resolved photon
counting. The instrument is designed to make optimal use of the grasp
(collecting area times solid angle product) provided by the optical design of
the Athena+ mirror system (Willingale et al. 2013), by combining a sensitive
approx. 40' diameter field of view (baseline; 50' goal) DEPFET detector with a
pixel size properly sampling the angular resolution of 5 arc sec on-axis (half
energy width).This synthesis makes the WFI a very powerful survey instrument,
significantly surpassing currently existing capabilities (Nandra et al. 2013;
Aird et al. 2013). In addition, the WFI will provide unprecedented simultaneous
high-time resolution and high count rate capabilities for the observation of
bright sources with low pile-up and high efficiency. In this paper, we
summarize the instrument design, the status of the technology development, and
the baseline performance.
[3]
oai:arXiv.org:astro-ph/0302500 [pdf] - 55127
Development of Silicon Strip Detectors for a Medium Energy Gamma-ray
Telescope
Submitted: 2003-02-24
We report on the design, production, and testing of advanced double-sided
silicon strip detectors under development at the Max-Planck-Institute as part
of the Medium Energy Gamma-ray Astronomy (MEGA) project. The detectors are
designed to form a stack, the "tracker," with the goal of recording the paths
of energetic electrons produced by Compton-scatter and pair-production
interactions. Each layer of the tracker is composed of a 3 x 3 array of 500
micron thick silicon wafers, each 6 cm x 6 cm and fitted with 128 orthogonal p
and n strips on opposite sides (470 micron pitch). The strips are biased using
the punch-through principle and AC-coupled via metal strips separated from the
strip implant by an insulating oxide/nitride layer. The strips from adjacent
wafers in the 3 x 3 array are wire-bonded in series and read out by 128-channel
TA1.1 ASICs, creating a total 19 cm x 19 cm position-sensitive area. At 20
degrees C a typical energy resolution of 15-20 keV FWHM, a position resolution
of 290 microns, and a time resolution of ~1 microsec is observed.
[4]
oai:arXiv.org:astro-ph/0110129 [pdf] - 1938814
The MEGA Advanced Compton Telescope Project
Submitted: 2001-10-05
The goal of the Medium Energy Gamma-ray Astronomy (MEGA) telescope is to
improve sensitivity at medium gamma-ray energies (0.4-50 MeV) by at least an
order of magnitude over that of COMPTEL. This will be achieved with a new
compact design that allows for a very wide field of view, permitting a
sensitive all-sky survey and the monitoring of transient and variable sources.
The key science objectives for MEGA include the investigation of cosmic
high-energy particle accelerators, studies of nucleosynthesis sites using
gamma-ray lines, and determination of the large-scale structure of galactic and
cosmic diffuse background emission. MEGA records and images gamma-ray events by
completely tracking both Compton and pair creation interactions in a tracker of
double-sided silicon strip detectors and a calorimeter of CsI crystals able to
resolve in three dimensions. We present initial laboratory calibration results
from a small prototype MEGA telescope.