Normalized to: André, Y.
[1]
oai:arXiv.org:1909.10598 [pdf] - 2017716
Space test of the Equivalence Principle: first results of the MICROSCOPE
mission
Touboul, Pierre;
Métris, Gilles;
Rodrigues, Manuel;
André, Yves;
Baghi, Quentin;
Bergé, Joel;
Boulanger, Damien;
Bremer, Stefanie;
Chhun, Ratana;
Christophe, Bruno;
Cipolla, Valerio;
Damour, Thibault;
Danto, Pascale;
Dittus, Hansjoerg;
Fayet, Pierre;
Foulon, Bernard;
Guidotti, Pierre-Yves;
Hardy, Emilie;
Huynh, Phuong-Anh;
Lämmerzahl, Claus;
Lebat, Vincent;
Liorzou, Françoise;
List, Meike;
Panet, Isabelle;
Pires, Sandrine;
Pouilloux, Benjamin;
Prieur, Pascal;
Reynaud, Serge;
Rievers, Benny;
Robert, Alain;
Selig, Hanns;
Serron, Laura;
Sumner, Timothy;
Visser, Pieter
Submitted: 2019-09-23
The Weak Equivalence Principle (WEP), stating that two bodies of different
compositions and/or mass fall at the same rate in a gravitational field
(universality of free fall), is at the very foundation of General Relativity.
The MICROSCOPE mission aims to test its validity to a precision of $10^{-15}$,
two orders of magnitude better than current on-ground tests, by using two
masses of different compositions (titanium and platinum alloys) on a
quasi-circular trajectory around the Earth. This is realised by measuring the
accelerations inferred from the forces required to maintain the two masses
exactly in the same orbit. Any significant difference between the measured
accelerations, occurring at a defined frequency, would correspond to the
detection of a violation of the WEP, or to the discovery of a tiny new type of
force added to gravity. MICROSCOPE's first results show no hint for such a
difference, expressed in terms of E\"otv\"os parameter
$\delta(Ti,Pt)=[-1\pm{}9{\rm (stat)}\pm{}9{\rm (syst)}] \times{}10^{-15}$ (both
1$\sigma$ uncertainties) for a titanium and platinum pair of materials. This
result was obtained on a session with 120 orbital revolutions representing 7\%
of the current available data acquired during the whole mission. The quadratic
combination of 1$\sigma$ uncertainties leads to a current limit on $\delta$ of
about $1.3\times{}10^{-14}$.
[2]
oai:arXiv.org:1804.05645 [pdf] - 1810141
PILOT balloon-borne experiment in-flight performance
Mangilli, A.;
Foënard, G.;
Aumont, J.;
Hughes, A.;
Mot, B.;
Bernard, J-Ph.;
Lacourt, A.;
Ristorcelli, I.;
Longval, Y.;
Ade, P.;
André, Y.;
Bautista, L.;
deBernardis, P.;
Boulade, O.;
Bousqet, F.;
Bouzit, M.;
Buttice, V.;
Charra, M.;
Crane, B.;
Doumayrou, E.;
Dubois, J. P.;
Engel, C.;
Griffin, M.;
Grabarnik, S.;
Hargrave, P.;
Laureijs, R.;
Leriche, B.;
Maestre, S.;
Maffei, B.;
Marty, C.;
Marty, W.;
Masi, S.;
Misawa, R.;
Montel, J.;
Montier, L.;
Narbonne, J.;
Pajot, F.;
Pérot, E.;
Pimentao, J.;
Pisano, G.;
Ponthieu, N.;
Rodriguez, L.;
Roudil, G.;
Salatino, M.;
Savini, G.;
Simonella, O.;
Saccoccio, M.;
Stever, S.;
Tauber, J.;
Tibbs, C.;
Tucker, C.
Submitted: 2018-04-16, last modified: 2019-01-07
The Polarized Instrument for Long-wavelength Observation of the Tenuous
interstellar medium (PILOT) is a balloon-borne experiment aiming at measuring
the polarized emission of thermal dust at a wavelength of 240 mm (1.2 THz). A
first PILOT flight (flight#1) of the experiment took place from Timmins,
Ontario, Canada, in September 2015 and a second flight (flight#2) took place
from Alice Springs, Australia in april 2017. In this paper, we present the
inflight performance of the instrument during these two flights. We concentrate
on performances during flight#2, but allude to flight#1 performances if
significantly different. We first present a short description of the instrument
and the flights. We determine the time constants of our detectors combining
inflight information from the signal decay following high energy particle
impacts (glitches) and of our internal calibration source. We use these time
constants to deconvolve the data timelines and analyse the optical quality of
the instrument as measured on planets. We then analyse the structure and
polarization of the instrumental background. We measure the detector response
flat field and its time variations using the signal from the residual
atmosphere and of our internal calibration source. Finally, we analyze the
detector noise spectral and temporal properties. The in-flight performances are
found to be satisfactory and globally in line with expectations from ground
calibrations. We conclude by assessing the expected in-flight sensitivity of
the instrument in light of the above in-flight performances.
[3]
oai:arXiv.org:1712.01176 [pdf] - 1878642
The MICROSCOPE mission: first results of a space test of the Equivalence
Principle
Touboul, Pierre;
Métris, Gilles;
Rodrigues, Manuel;
André, Yves;
Baghi, Quentin;
Bergé, Joel;
Boulanger, Damien;
Bremer, Stefanie;
Carle, Patrice;
Chhun, Ratana;
Christophe, Bruno;
Cipolla, Valerio;
Damour, Thibault;
Danto, Pascale;
Dittus, Hansjoerg;
Fayet, Pierre;
Foulon, Bernard;
Gageant, Claude;
Guidotti, Pierre-Yves;
Hagedorn, Daniel;
Hardy, Emilie;
Huynh, Phuong-Anh;
Inchauspe, Henri;
Kayser, Patrick;
Lala, Stéphanie;
Lämmerzahl, Claus;
Lebat, Vincent;
Leseur, Pierre;
Liorzou, Françoise;
List, Meike;
Löffle, Frank;
Panet, Isabelle;
Pouilloux, Benjamin;
Prieur, Pascal;
Rebray, Alexandre;
Reynaud, Serge;
Rievers, Benny;
Robert, Alain;
Selig, Hanns;
Serron, Laura;
Sumner, Timothy;
Tanguy, Nicolas;
Visser, Pieter
Submitted: 2017-12-04, last modified: 2017-12-06
According to the Weak Equivalence Principle, all bodies should fall at the
same rate in a gravitational field. The MICROSCOPE satellite, launched in April
2016, aims to test its validity at the $10^{-15}$ precision level, by measuring
the force required to maintain two test masses (of titanium and platinum
alloys) exactly in the same orbit. A non-vanishing result would correspond to a
violation of the Equivalence Principle, or to the discovery of a new long-range
force. Analysis of the first data gives $\delta\rm{(Ti,Pt)}= [-1 \pm 9
(\mathrm{stat}) \pm 9 (\mathrm{syst})] \times 10^{-15}$ (1$\sigma$ statistical
uncertainty) for the titanium-platinum E\"otv\"os parameter characterizing the
relative difference in their free-fall accelerations.
[4]
oai:arXiv.org:astro-ph/0308504 [pdf] - 58783
INTEGRAL/SPI ground calibration
Attié, D.;
Cordier, B.;
Gros, M.;
Laurent, Ph.;
Schanne, S.;
Tauzin, G.;
von Ballmoos, P.;
Bouchet, L.;
Jean, P.;
Knödlseder, J.;
Mandrou, P.;
Paul, Ph.;
Roques, J. -P.;
Skinner, G.;
Vedrenne, G.;
Georgii, R.;
von Kienlin, A.;
Lichti, G.;
Schönfelder, V.;
Strong, A.;
Wunderer, C.;
Shrader, C.;
Sturner, S.;
Teegarden, B.;
Weidenspointner, G.;
Kiener, J.;
Porquet, M. -G.;
Tatischeff, V.;
Crespin, S.;
Joly, S.;
André, Y.;
Sanchez, F.;
Leleux, P.
Submitted: 2003-08-28
Three calibration campaigns of the spectrometer SPI have been performed
before launch in order to determine the instrument characteristics, such as the
effective detection area, the spectral resolution and the angular resolution.
Absolute determination of the effective area has been obtained from simulations
and measurements. At 1 MeV, the effective area is 65 cm^2 for a point source on
the optical axis, the spectral resolution ~2.3 keV. The angular resolution is
better than 2.5 deg and the source separation capability about 1 deg. Some
temperature dependant parameters will require permanent in-flight calibration.