sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

André, Y.

Normalized to: André, Y.

4 article(s) in total. 125 co-authors, from 1 to 2 common article(s). Median position in authors list is 7,5.

[1]  oai:arXiv.org:1909.10598  [pdf] - 2017716
Space test of the Equivalence Principle: first results of the MICROSCOPE mission
Comments: To appear in CQG
Submitted: 2019-09-23
The Weak Equivalence Principle (WEP), stating that two bodies of different compositions and/or mass fall at the same rate in a gravitational field (universality of free fall), is at the very foundation of General Relativity. The MICROSCOPE mission aims to test its validity to a precision of $10^{-15}$, two orders of magnitude better than current on-ground tests, by using two masses of different compositions (titanium and platinum alloys) on a quasi-circular trajectory around the Earth. This is realised by measuring the accelerations inferred from the forces required to maintain the two masses exactly in the same orbit. Any significant difference between the measured accelerations, occurring at a defined frequency, would correspond to the detection of a violation of the WEP, or to the discovery of a tiny new type of force added to gravity. MICROSCOPE's first results show no hint for such a difference, expressed in terms of E\"otv\"os parameter $\delta(Ti,Pt)=[-1\pm{}9{\rm (stat)}\pm{}9{\rm (syst)}] \times{}10^{-15}$ (both 1$\sigma$ uncertainties) for a titanium and platinum pair of materials. This result was obtained on a session with 120 orbital revolutions representing 7\% of the current available data acquired during the whole mission. The quadratic combination of 1$\sigma$ uncertainties leads to a current limit on $\delta$ of about $1.3\times{}10^{-14}$.
[2]  oai:arXiv.org:1804.05645  [pdf] - 1810141
PILOT balloon-borne experiment in-flight performance
Comments:
Submitted: 2018-04-16, last modified: 2019-01-07
The Polarized Instrument for Long-wavelength Observation of the Tenuous interstellar medium (PILOT) is a balloon-borne experiment aiming at measuring the polarized emission of thermal dust at a wavelength of 240 mm (1.2 THz). A first PILOT flight (flight#1) of the experiment took place from Timmins, Ontario, Canada, in September 2015 and a second flight (flight#2) took place from Alice Springs, Australia in april 2017. In this paper, we present the inflight performance of the instrument during these two flights. We concentrate on performances during flight#2, but allude to flight#1 performances if significantly different. We first present a short description of the instrument and the flights. We determine the time constants of our detectors combining inflight information from the signal decay following high energy particle impacts (glitches) and of our internal calibration source. We use these time constants to deconvolve the data timelines and analyse the optical quality of the instrument as measured on planets. We then analyse the structure and polarization of the instrumental background. We measure the detector response flat field and its time variations using the signal from the residual atmosphere and of our internal calibration source. Finally, we analyze the detector noise spectral and temporal properties. The in-flight performances are found to be satisfactory and globally in line with expectations from ground calibrations. We conclude by assessing the expected in-flight sensitivity of the instrument in light of the above in-flight performances.
[3]  oai:arXiv.org:1712.01176  [pdf] - 1878642
The MICROSCOPE mission: first results of a space test of the Equivalence Principle
Comments: Typos corrected
Submitted: 2017-12-04, last modified: 2017-12-06
According to the Weak Equivalence Principle, all bodies should fall at the same rate in a gravitational field. The MICROSCOPE satellite, launched in April 2016, aims to test its validity at the $10^{-15}$ precision level, by measuring the force required to maintain two test masses (of titanium and platinum alloys) exactly in the same orbit. A non-vanishing result would correspond to a violation of the Equivalence Principle, or to the discovery of a new long-range force. Analysis of the first data gives $\delta\rm{(Ti,Pt)}= [-1 \pm 9 (\mathrm{stat}) \pm 9 (\mathrm{syst})] \times 10^{-15}$ (1$\sigma$ statistical uncertainty) for the titanium-platinum E\"otv\"os parameter characterizing the relative difference in their free-fall accelerations.
[4]  oai:arXiv.org:astro-ph/0308504  [pdf] - 58783
INTEGRAL/SPI ground calibration
Comments: 9 pages, 12 figures, 2 tables. Accepted for publication in A&AL (INTEGRAL Special issue)
Submitted: 2003-08-28
Three calibration campaigns of the spectrometer SPI have been performed before launch in order to determine the instrument characteristics, such as the effective detection area, the spectral resolution and the angular resolution. Absolute determination of the effective area has been obtained from simulations and measurements. At 1 MeV, the effective area is 65 cm^2 for a point source on the optical axis, the spectral resolution ~2.3 keV. The angular resolution is better than 2.5 deg and the source separation capability about 1 deg. Some temperature dependant parameters will require permanent in-flight calibration.