sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Amman, M.

Normalized to: Amman, M.

8 article(s) in total. 56 co-authors, from 1 to 8 common article(s). Median position in authors list is 11,0.

[1]  oai:arXiv.org:1908.04334  [pdf] - 1938619
The Compton Spectrometer and Imager
Comments: 11 pages, submitted to the Decadal Survey on Astronomy and Astrophysics (Astro2020) as an Activities, Projects, or State of the Profession Consideration (APC) White Paper
Submitted: 2019-08-12
In this Astro2020 APC White Paper, we describe a Small Explorer (SMEX) mission concept called the Compton Spectrometer and Imager. COSI is a Compton telescope that covers the bandpass often referred to as the "MeV Gap" because it is the least explored region of the whole electromagnetic spectrum. COSI provides a significant improvement in sensitivity along with high-resolution spectroscopy, enabling studies of 511 keV electron-positron annihilation emission and measurements of several radioactive elements that trace the Galactic history of supernovae. COSI also measures polarization of gamma-ray bursts (GRBs), accreting black holes, and pulsars as well as detecting and localizing multimessenger sources. In the following, we describe the COSI science, the instrument, and its capabilities. We highlight many Astro2020 science WPs that describe the COSI science in depth.
[2]  oai:arXiv.org:1705.02652  [pdf] - 1701499
A Combined Compton and Coded-aperture Telescope for Medium-energy Gamma-ray Astrophysics
Comments:
Submitted: 2017-05-07, last modified: 2018-01-31
A future mission in medium-energy gamma-ray astrophysics would allow for many scientific advancements, e.g. a possible explanation for the excess positron emission from the Galactic Center, a better understanding of nucleosynthesis and explosion mechanisms in Type Ia supernovae, and a look at the physical forces at play in compact objects such as black holes and neutron stars. Additionally, further observation in this energy regime would significantly extend the search parameter space for low-mass dark matter. In order to achieve these objectives, an instrument with good energy resolution, good angular resolution, and high sensitivity is required. In this paper we present the design and simulation of a Compton telescope consisting of cubic-centimeter Cadmium Zinc Telluride (CdZnTe) detectors as absorbers behind a silicon tracker with the addition of a passive coded mask. The goal of the design was to create a very sensitive instrument that is capable of high angular resolution. The simulated telescope showed achievable energy resolutions of 1.68$\%$ FWHM at 511 keV and 1.11$\%$ at 1809 keV, on-axis angular resolutions in Compton mode of 2.63$^{\circ}$ FWHM at 511 keV and 1.30$^{\circ}$ FWHM at 1809 keV, and is capable of resolving sources to at least 0.2$^{\circ}$ at lower energies with the use of the coded mask. An initial assessment of the instrument in Compton imaging mode yields an effective area of 183 cm$^{2}$ at 511 keV and an anticipated all-sky sensitivity of 3.6 x 10$^{-6}$ photons cm$^{-2}$ s$^{-1}$ for a broadened 511 keV source over a 2-year observation time. Additionally, combining a coded mask with a Compton imager to improve point source localization for positron detection has been demonstrated.
[3]  oai:arXiv.org:1709.05349  [pdf] - 1588457
Polarimetric Analysis of the Long Duration Gamma Ray Burst GRB 160530A With the Balloon Borne Compton Spectrometer and Imager
Comments: For more information regarding our implementation of maximum likelihood Compton polarimetry, please see our accompanying paper "Maximum Likelihood Compton Polarimetry with the Compton Spectrometer and Imager"
Submitted: 2017-09-15
A long duration gamma-ray burst, GRB 160530A, was detected by the Compton Spectrometer and Imager (COSI) during the 2016 COSI Super Pressure Balloon campaign. As a Compton telescope, COSI is inherently sensitive to the polarization of gamma-ray sources in the energy range 0.2-5.0 MeV. We measured the polarization of GRB 160530A using 1) a standard method (SM) based on fitting the distribution of azimuthal scattering angles with a modulation curve, and 2) an unbinned, maximum likelihood method (MLM). In both cases, the measured polarization level was below the $99\%$ confidence minimum detectable polarization levels of $72.3 \pm 0.8\%$ (SM) and $57.5 \pm 0.8\%$ (MLM). Therefore, COSI did not detect polarized gamma-ray emission from this burst. Our most constraining $90\%$ confidence upper limit on the polarization level was $46\%$ (MLM).
[4]  oai:arXiv.org:1709.05352  [pdf] - 1588460
Maximum Likelihood Compton Polarimetry with the Compton Spectrometer and Imager
Comments: This paper is meant to accompany another paper by the same authors: "Polarimetric Analysis of the Long Duration Gamma Ray Burst GRB 160530A With the Balloon Borne Compton Spectrometer and Imager"
Submitted: 2017-09-15
Astrophysical polarization measurements in the soft gamma-ray band are becoming more feasible as detectors with high position and energy resolution are deployed. Previous work has shown that the minimum detectable polarization (MDP) of an ideal Compton polarimeter can be improved by $\sim 21\%$ when an unbinned, maximum likelihood method is used instead of the standard approach of fitting a sinusoid to a histogram of azimuthal scattering angles. Here we outline a procedure for implementing this maximum likelihood approach for real, non-ideal polarimeters. As an example, we use the recent observation of GRB 160530A with the Compton Spectrometer and Imager. We find that the MDP for this observation is reduced by $20\%$ when the maximum likelihood method is used instead of the standard method.
[5]  oai:arXiv.org:1701.05558  [pdf] - 1534767
The 2016 Super Pressure Balloon flight of the Compton Spectrometer and Imager
Comments: 10 pages, 17 figures, Proceedings in 11th INTEGRAL Conference: Gamma-Ray Astrophysics in Multi-Wavelength Perspective, 10-14 October 2016, Amsterdam, The Netherlands
Submitted: 2017-01-19
The Compton Spectrometer and Imager (COSI) is a balloon-borne, soft-gamma ray imager, spectrometer, and polarimeter with sensitivity from 0.2 to 5 MeV. Utilizing a compact Compton telescope design with twelve cross-strip, high-purity germanium detectors, COSI has three main science goals: study the 511 keV positron annihilation line from the Galactic plane, image diffuse emission from stellar nuclear lines, and perform polarization studies of gamma-ray bursts and other extreme astrophysical environments. COSI has just completed a successful 46-day flight on NASA's new Super Pressure Balloon, launched from Wanaka, New Zealand, in May 2016. We present an overview of the instrument and the 2016 flight, and discuss COSI's main science goals, predicted performance, and preliminary results.
[6]  oai:arXiv.org:1701.05563  [pdf] - 1534770
Benchmarking COSI's detector effects engine
Comments: 10 pages, 11 figures, proceedings in 11th INTEGRAL Conference: Gamma-ray Astrophysics in Multi-Wavelength Perspective, 10-14 October 2016, Amsterdam, The Netherlands
Submitted: 2017-01-19
The Compton Spectrometer and Imager (COSI) is a balloon-borne gamma-ray (0.2-5 MeV) telescope with inherent sensitivity to polarization. COSI's main goal is to study astrophysical sources such as $\gamma$-ray bursts, positron annihilation, Galactic nucleosynthesis, and compact objects. COSI employs a compact Compton telescope design utilizing 12 high-purity cross strip germanium detectors (size: $8\times8\times1.5$ cm$^3$, 2 mm strip pitch). We require well-benchmarked simulations to simulate the full instrument response used for data analysis, to optimize our analysis algorithms, and to better understand our instrument and the in-flight performance. In order to achieve a reasonable agreement, we have built a comprehensive mass model of the instrument and developed a detailed detector effects engine, which takes into account the individual performance of each strip as well as the characteristics of the overall detector system. We performed detailed Monte-Carlo simulations with Cosima/Geant4, applied the detector effects engine, and benchmarked the results with pre-flight calibrations using radioactive sources. After applying the detector effects engine, the simulations closely resemble the measurements, and the standard calibration, event reconstruction, and imaging pipeline used for measurements can also be applied to the simulations. In this manuscript, we will describe the detector effects engine, the benchmarking tests with calibrations, and the application to preliminary results from COSI's 46-day balloon flight in 2016.
[7]  oai:arXiv.org:1609.08558  [pdf] - 1487065
First flight of the Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) instrument
Comments: 17 pages, 15 figures; presented at SPIE 9905 (Space Telescopes and Instrumentation 2016: Ultraviolet to Gamma Ray) in Edinburgh, Scotland
Submitted: 2016-09-27
The Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) is a balloon-borne telescope designed to study solar-flare particle acceleration and transport. We describe GRIPS's first Antarctic long-duration flight in Jan 2016 and report preliminary calibration and science results. Electron and ion dynamics, particle abundances and the ambient plasma conditions in solar flares can be understood by examining hard X-ray (HXR) and gamma-ray emission (20 keV to 10 MeV) with enhanced imaging, spectroscopy and polarimetry. GRIPS is specifically designed to answer questions including: What causes the spatial separation between energetic electrons producing HXRs and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? GRIPS's key technological improvements over the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) include 3D position-sensitive germanium detectors (3D-GeDs) and a single-grid, multi-pitch rotating modulator (MPRM) collimator. The 3D-GeDs have spectral FWHM resolution of a few hundred keV and spatial resolution $<$1 mm$^3$. For photons that Compton scatter, usually $\gtrsim$150 keV, the energy deposition sites can be tracked, providing polarization measurements as well as enhanced background reduction. The MPRM single-grid design provides twice the throughput of a bi-grid imaging system like RHESSI. The grid is composed of 2.5 cm thick W/Cu slats with 1-13 mm variable slit pitch, achieving quasi-continuous FWHM angular coverage over 12.5-162 arcsecs. This resolution is capable of imaging the separate magnetic loop footpoint emissions in a variety of flare sizes. (Abstract edited down from source.)
[8]  oai:arXiv.org:1106.0323  [pdf] - 1077028
Detection and Imaging of the Crab Nebula with the Nuclear Compton Telescope
Comments: 10 pages, 9 figures, accepted for publication in the Astrophysical Journal
Submitted: 2011-06-01
The Nuclear Compton Telescope (NCT) is a balloon-borne Compton telescope designed for the study of astrophysical sources in the soft gamma-ray regime (200 keV--20 MeV). NCT's ten high-purity germanium crossed-strip detectors measure the deposited energies and three-dimensional positions of gamma-ray interactions in the sensitive volume, and this information is used to restrict the initial photon to a circle on the sky using the Compton scatter technique. Thus NCT is able to perform spectroscopy, imaging, and polarization analysis on soft gamma-ray sources. NCT is one of the next generation of Compton telescopes --- so-called compact Compton telescopes (CCTs) --- which can achieve effective areas comparable to COMPTEL's with an instrument that is a fraction of the size. The Crab Nebula was the primary target for the second flight of the NCT instrument, which occurred on 17--18 May 2009 in Fort Sumner, New Mexico. Analysis of 29.3 ks of data from the flight reveals an image of the Crab at a significance of 4-sigma. This is the first reported detection of an astrophysical source by a CCT.