Normalized to: Amato, S.
[1]
oai:arXiv.org:1905.03320 [pdf] - 1898058
Binospec: A Wide-field Imaging Spectrograph for the MMT
Fabricant, Daniel;
Fata, Robert;
Epps, Harland;
Gauron, Thomas;
Mueller, Mark;
Zajac, Joseph;
Amato, Stephen;
Barberis, Jack;
Bergner, Henry;
Brennan, Patricia;
Brown, Warren;
Chilingarian, Igor;
Geary, John;
Kradinov, Vladimir;
McLeod, Brian;
Smith, Matthew;
Woods, Deborah
Submitted: 2019-05-08
Binospec is a high throughput, 370 to 1000 nm, imaging spectrograph that
addresses two adjacent 8' by 15' fields of view. Binospec was commissioned in
late 2017 at the f/5 focus of the 6.5m MMT and is now available to all MMT
observers. Aperture masks cut from stainless steel with a laser cutter are used
to define the entrance apertures that range from 15' long slits to hundreds of
2" slitlets. System throughputs, including the MMT's mirrors and the f/5
wide-field corrector peak at ~30%. Three reflection gratings, duplicated for
the two beams, provide resolutions ($\lambda$/$\Delta \lambda$) between 1300
and $>$5000 with a 1" wide slit. Two through-the-mask guiders are used for
target acquisition, mask alignment, guiding, and precision offsets. A full-time
Shack-Hartmann wave front sensor allows continuous adjustment of primary mirror
support forces, telescope collimation and focus. Active flexure control
maintains spectrograph alignment and focus under varying gravity and thermal
conditions.
[2]
oai:arXiv.org:1211.6174 [pdf] - 610858
MMT & Magellan Infrared Spectrograph
McLeod, Brian;
Fabricant, Daniel;
Nystrom, George;
McCracken, Ken;
Amato, Stephen;
Bergner, Henry;
Brown, Warren;
Burke, Michael;
Chilingarian, Igor;
Conroy, Maureen;
Curley, Dylan;
Furesz, Gabor;
Geary, John;
Hertz, Edward;
Holwell, Justin;
Matthews, Anne;
Norton, Tim;
Park, Sang;
Roll, John;
Zajac, Joseph;
Epps, Harland;
Martini, Paul
Submitted: 2012-11-26
The MMT and Magellan infrared spectrograph (MMIRS) is a cryogenic multiple
slit spectrograph operating in the wavelength range 0.9-2.4 micron. MMIRS'
refractive optics offer a 6.9 by 6.9 arcmin field of view for imaging with a
spatial resolution of 0.2 arcsec per pixel on a HAWAII-2 array. For
spectroscopy, MMIRS can be used with long slits up to 6.9 arcmin long, or with
custom slit masks having slitlets distributed over a 4 by 6.9 arcmin area. A
range of dispersers offer spectral resolutions of 800 to 3000. MMIRS is
designed to be used at the f/5 foci of the MMT or Magellan Clay 6.5m
telescopes. MMIRS was commissioned in 2009 at the MMT and has been in routine
operation at the Magellan Clay Telescope since 2010. MMIRS is being used for a
wide range of scientific investigations from exoplanet atmospheres to Ly-alpha
emitters.