Normalized to: Altariba, E.
[1]
oai:arXiv.org:1007.4968 [pdf] - 1033973
The third version of the AMBER data reduction software
Malbet, Fabien;
Duvert, Gilles;
Millour, Florentin;
Bouquin, Jean-Baptiste Le;
Mella, Guillaume;
Halipré, Luc;
Chelli, Alain;
Lafrasse, Sylvain;
Altariba, Evelyne;
Zins, Gérard
Submitted: 2010-07-28
We present the third release of the AMBER data reduction software by the
JMMC. This software is based on core algorithms optimized after several years
of operation. An optional graphic interface in a high level language allows the
user to control the process step by step or in a completely automatic manner.
Ongoing improvement is the implementation of a robust calibration scheme,
making use of the full calibration sets available during the night. The output
products are standard OI-FITS files, which can be used directly in high level
software like model fitting or image reconstruction tools. The software
performances are illustrated on a full data set of calibrators observed with
AMBER during 5 years taken in various instrumental setup.
[2]
oai:arXiv.org:0705.1636 [pdf] - 1000395
AMBER on the VLTI: data processing and calibration issues
Millour, Florentin;
Petrov, Romain;
Malbet, Fabien;
Tatulli, Eric;
Duvert, Gilles;
Zins, Gérard;
Altariba, Evelyne;
Vannier, Martin;
Hernandez, Oscar;
Causi, Gianluca Li
Submitted: 2007-05-11
We present here the current performances of the AMBER / VLTI instrument for
standard use and compare these with the offered modes of the instrument. We
show that the instrument is able to reach its specified precision only for
medium and high spectral resolution modes, differential observables and bright
objects. For absolute observables, the current achievable accuracy is strongly
limited by the vibrations of the Unit Telescopes, and also by the observing
procedure which does not take into account the night-long transfer function
monitoring. For low-resolution mode, the current limitation is more in the data
reduction side, since several effects negligible at medium spectral resolution
are not taken into account in the current pipeline. Finally, for faint objects
(SNR around 1 per spectral channel), electromagnetic interferences in the VLTI
interferometric laboratory with the detector electronics prevents currently to
get unbiased measurements. Ideas are under study to correct in the data
processing side this effect, but a hardware fix should be investigated
seriously since it limits seriously the effective limiting magnitude of the
instrument.