Normalized to: Alessandro, G.
[1]
oai:arXiv.org:1402.4091 [pdf] - 826613
Efficient Differential Fourier-Transform Spectrometer for precision
Sunyaev-Zel'dovich effect measurements
Submitted: 2014-02-17, last modified: 2014-05-26
Precision measurements of the Sunyaev-Zel'dovich effect in clusters of
galaxies require excellent rejection of common-mode signals and wide frequency
coverage. We describe an imaging, efficient, differential Fourier transform
spectrometer (FTS), optimized for measurements of faint brightness gradients at
millimeter wavelengths. Our instrument is based on a Martin-Puplett
interferometer (MPI) configuration. We combined two MPIs working synchronously
to use the whole input power. In our implementation the observed sky field is
divided into two halves along the meridian, and each half-field corresponds to
one of the two input ports of the MPI. In this way, each detector in the FTS
focal planes measures the difference in brightness between two sky pixels,
symmetrically located with respect to the meridian. Exploiting the high
common-mode rejection of the MPI, we can measure low sky brightness gradients
over a high isotropic background. The instrument works in the range $\sim$
1$-$20 cm$^{-1}$ (30$-$600 GHz), has a maximum spectral resolution $1/(2 \ OPD)
= 0.063 \ cm^{-1}$ (1.9 GHz), and an unvignetted throughput of 2.3 cm$^2$sr. It
occupies a volume of 0.7$\times$0.7$\times$0.33 m$^3$ and has a weight of 70
kg. This design can be implemented as a cryogenic unit to be used in space, as
well as a room-temperature unit working at the focus of suborbital and
ground-based mm-wave telescopes. The first in-flight test of the instrument is
with the OLIMPO experiment on a stratospheric balloon; a larger implementation
is being prepared for the Sardinia radio telescope.
[2]
oai:arXiv.org:1212.3969 [pdf] - 1158547
On the emissivity of wire-grid polarizers for astronomical observations
at mm-wavelengths
Submitted: 2012-12-17
We have measured, using a custom setup, the emissivity of metallic
wire-grids, suitable for polarimeters and interferometers at mm and far
infrared wavelengths. We find that the effective emissivity of these devices is
of the order of a few %, depending on fabrication technology and aging. We
discuss their use in astronomical instruments, with special attention to Martin
Puplett Interferometers in low-background applications, like astronomical
observations of the Cosmic Microwave Background.
[3]
oai:arXiv.org:1208.0282 [pdf] - 1150439
SWIPE: a bolometric polarimeter for the Large-Scale Polarization
Explorer
de Bernardis, P.;
Aiola, S.;
Amico, G.;
Battistelli, E.;
Coppolecchia, A.;
Cruciani, A.;
Addabbo, A. D';
Alessandro, G. D';
De Gregori, S.;
De Petris, M.;
Goldie, D.;
Gualtieri, R.;
Haynes, V.;
Lamagna, L.;
Maffei, B.;
Masi, S.;
Nati, F.;
Ng, M. Wah;
Pagano, L.;
Piacentini, F.;
Piccirillo, L.;
Pisano, G.;
Romeo, G.;
Salatino, M.;
Schillaci, A.;
Tommasi, E.;
Withington, S.
Submitted: 2012-08-01
The balloon-borne LSPE mission is optimized to measure the linear
polarization of the Cosmic Microwave Background at large angular scales. The
Short Wavelength Instrument for the Polarization Explorer (SWIPE) is composed
of 3 arrays of multi-mode bolometers cooled at 0.3K, with optical components
and filters cryogenically cooled below 4K to reduce the background on the
detectors. Polarimetry is achieved by means of large rotating half-wave plates
and wire-grid polarizers in front of the arrays. The polarization modulator is
the first component of the optical chain, reducing significantly the effect of
instrumental polarization. In SWIPE we trade angular resolution for
sensitivity. The diameter of the entrance pupil of the refractive telescope is
45 cm, while the field optics is optimized to collect tens of modes for each
detector, thus boosting the absorbed power. This approach results in a FWHM
resolution of 1.8, 1.5, 1.2 degrees at 95, 145, 245 GHz respectively. The
expected performance of the three channels is limited by photon noise,
resulting in a final sensitivity around 0.1-0.2 uK per beam, for a 13 days
survey covering 25% of the sky.
[4]
oai:arXiv.org:1111.4588 [pdf] - 497111
Low-resolution spectroscopy of the Sunyaev-Zel'dovich effect and
estimates of cluster parameters
Submitted: 2011-11-19
The Sunyaev-Zel'dovich (SZ) effect is a powerful tool for studying clusters
of galaxies and cosmology. Large mm-wave telescopes are now routinely detecting
and mapping the SZ effect in a number of clusters, measure their comptonisation
parameter and use them as probes of the large-scale structure and evolution of
the universe. We show that estimates of the physical parameters of clusters
(optical depth, plasma temperature, peculiar velocity, non-thermal components
etc.) obtained from ground-based multi-band SZ photometry can be significantly
biased, owing to the reduced frequency coverage, to the degeneracy between the
parameters and to the presence of a number of independent components larger
than the number of frequencies measured. We demonstrate that low-resolution
spectroscopic measurements of the SZ effect that also cover frequencies $> 270$
GHz are effective in removing the degeneracy. We used accurate simulations of
observations with lines-of-sight through clusters of galaxies with different
experimental configurations (4-band photometers, 6-band photometer, multi-range
differential spectrometer, full coverage spectrometers) and different
intracluster plasma stratifications. We find that measurements carried out with
ground-based few-band photometers are biased towards high electron temperatures
and low optical depths, and require coverage of high frequency and/or
independent complementary observations to produce unbiased information; a
differential spectrometer that covers 4 bands with a resolution of $\sim 6 \
GHz$ eliminates most if not all bias; full-range differential spectrometers are
the ultimate resource that allows a full recovery of all parameters.