Normalized to: Alberi, M.
[1]
oai:arXiv.org:1802.00327 [pdf] - 1628298
Accuracy of Flight Altitude Measured with Low-Cost GNSS, Radar and
Barometer Sensors: Implications for Airborne Radiometric Surveys
Alberi, Matteo;
Baldoncini, Marica;
Bottardi, Carlo;
Chiarelli, Enrico;
Fiorentini, Giovanni;
Raptis, Kassandra Giulia Cristina;
Realini, Eugenio;
Reguzzoni, Mirko;
Rossi, Lorenzo;
Sampietro, Daniele;
Strati, Virginia;
Mantovani, Fabio
Submitted: 2018-01-08
Flight height is a fundamental parameter for correcting the gamma signal
produced by terrestrial radionuclides measured during airborne surveys. The
frontiers of radiometric measurements with UAV require light and accurate
altimeters flying at some 10 m from the ground. We equipped an aircraft with
seven altimetric sensors (three low-cost GNSS receivers, one inertial
measurement unit, one radar altimeter and two barometers) and analyzed $\sim$ 3
h of data collected over the sea in the (35-2194) m altitude range. At low
altitudes (H $<$ 70 m) radar and barometric altimeters provide the best
performances, while GNSS data are used only for barometer calibration as they
are affected by a large noise due to the multipath from the sea. The $\sim$ 1 m
median standard deviation at 50 m altitude affects the estimation of the ground
radioisotope abundances with an uncertainty less than 1.3%. The GNSS
double-difference post-processing enhanced significantly the data quality for H
$>$ 80 m in terms of both altitude median standard deviation and agreement
between the reconstructed and measured GPS antennas distances. Flying at 100 m
the estimated uncertainty on the ground total activity due to the uncertainty
on the flight height is of the order of 2%.
[2]
oai:arXiv.org:1503.02486 [pdf] - 1231979
Performance of the VLT Planet Finder SPHERE II. Data analysis and
Results for IFS in laboratory
Mesa, D.;
Gratton, R.;
Zurlo, A.;
Vigan, A.;
Claudi, R. U.;
Alberi, M.;
Antichi, J.;
Baruffolo, A.;
Beuzit, J. -L.;
Boccaletti, A.;
Bonnefoy, M.;
Costille, A.;
Desidera, S.;
Dohlen, K.;
Fantinel, D.;
Feldt, M.;
Fusco, T.;
Giro, E.;
Henning, T.;
Kasper, M.;
Langlois, M.;
Maire, A. -L.;
Martinez, P.;
Moeller-Nilsson, O.;
Mouillet, D.;
Moutou, C.;
Pavlov, A.;
Puget, P.;
Salasnich, B.;
Sauvage, J. -F.;
Sissa, E.;
Turatto, M.;
Udry, S.;
Vakili, F.;
Waters, R.;
Wildi, F.
Submitted: 2015-03-09
We present the performance of the Integral Field Spectrograph (IFS) of
SPHERE, the high-contrast imager for the ESO VLT telescope designed to perform
imaging and spectroscopy of extrasolar planets, obtained from tests performed
at the Institute de Plan\'etologie et d'Astrophysique de Grenoble facility
during the integration phase of the instrument.} {The tests were performed
using the instrument software purposely prepared for SPHERE. The output data
were reduced applying the SPHERE data reduction and handling software, adding
an improved spectral deconvolution procedure. To this aim, we prepared an
alternative procedure for the spectral subtraction exploiting the principal
components analysis algorithm. Moreover, a simulated angular differential
imaging procedure was also implemented to estimate how the instrument performed
once this procedure was applied at telescope. The capability of the IFS to
faithfully retrieve the spectra of the detected faint companions was also
considered.} {We found that the application of the updated version of the
spectral deconvolution procedure alone, when the algorithm throughput is
properly taken into account, gives us a $5\sigma$ limiting contrast of the
order of 5$\times$$10^{-6}$ or slightly better. The further application of the
angular differential imaging procedure on these data should allow us to improve
the contrast by one order of magnitude down to around 7$\times$$10^{-7}$ at a
separation of 0.3 arcsec. The application of a principal components analysis
procedure that simultaneously uses spectral and angular data gives comparable
results. Finally, we found that the reproducibility of the spectra of the
detected faint companions is greatly improved when angular differential imaging
is applied in addition to the spectral deconvolution.