Normalized to: Akimov, D.
[3]
oai:arXiv.org:1611.07168 [pdf] - 1567614
New method of 85Kr reduction in a noble gas based low-background
detector
Submitted: 2016-11-22
Krypton-85 is an anthropogenic beta-decaying isotope which produces low
energy backgrounds in dark matter and neutrino experiments, especially those
based upon liquid xenon. Several technologies have been developed to reduce the
Kr concentration in such experiments. We propose to augment those separation
technologies by first adding to the xenon an 85Kr-free sample of krypton in an
amount much larger than the natural krypton that is already present. After the
purification system reduces the total Kr concentration to the same level, the
final 85Kr concentration will have been reduced even further by the dilution
factor. A test cell for measurement of the activity of various Kr samples has
been assembled, and the activity of 25-year-old Krypton has been measured. The
measured activity agrees well with the expected activity accounting for the
85Kr abundance of the earth atmosphere in 1990 and the half-life of the
isotope. Additional tests with a Kr sample produced in the year 1944 (before
the atomic era) have been done in order to demonstrate the sensitivity of the
test cell.
[4]
oai:arXiv.org:1509.02910 [pdf] - 1286987
LUX-ZEPLIN (LZ) Conceptual Design Report
The LZ Collaboration;
Akerib, D. S.;
Akerlof, C. W.;
Akimov, D. Yu.;
Alsum, S. K.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Balashov, S.;
Barry, M. J.;
Bauer, P.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boast, K. E.;
Bolozdynya, A. I.;
Boulton, E. M.;
Bramante, R.;
Buckley, J. H.;
Bugaev, V. V.;
Bunker, R.;
Burdin, S.;
Busenitz, J. K.;
Carels, C.;
Carlsmith, D. L.;
Carlson, B.;
Carmona-Benitez, M. C.;
Cascella, M.;
Chan, C.;
Cherwinka, J. J.;
Chiller, A. A.;
Chiller, C.;
Craddock, W. W.;
Currie, A.;
Cutter, J. E.;
da Cunha, J. P.;
Dahl, C. E.;
Dasu, S.;
Davison, T. J. R.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edberg, T. K.;
Edwards, B. N.;
Edwards, W. R.;
Elnimr, M. M.;
Emmet, W. T.;
Faham, C. H.;
Fiorucci, S.;
Ford, P.;
Francis, V. B.;
Fu, C.;
Gaitskell, R. J.;
Gantos, N. J.;
Gehman, V. M.;
Gerhard, R. M.;
Ghag, C.;
Gilchriese, M. G. D.;
Gomber, B.;
Hall, C. R.;
Harris, A.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hoff, M. D.;
Holbrook, B.;
Holtom, E.;
Huang, D. Q.;
Hurteau, T. W.;
Ignarra, C. M.;
Jacobsen, R. G.;
Ji, W.;
Ji, X.;
Johnson, M.;
Ju, Y.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Khazov, A.;
Khromov, A. V.;
Konovalov, A. M.;
Korolkova, E. V.;
Kraus, H.;
Krebs, H. J.;
Kudryavtsev, V. A.;
Kumpan, A. V.;
Kyre, S.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Liao, F. -T.;
Lin, J.;
Lindote, A.;
Lippincott, W. H.;
Liu, J.;
Liu, X.;
Lopes, M. I.;
Lorenzon, W.;
Luitz, S.;
Majewski, P.;
Malling, D. C.;
Manalaysay, A. G.;
Manenti, L.;
Mannino, R. L.;
Markley, D. J.;
Martin, T. J.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. -M.;
Meng, Y.;
Miller, E. H.;
Mock, J.;
Monzani, M. E.;
Morad, J. A.;
Murphy, A. St. J.;
Nelson, H. N.;
Neves, F.;
Nikkel, J. A.;
O'Neill, F. G.;
O'Dell, J.;
O'Sullivan, K.;
Olevitch, M. A.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pangilinan, M.;
Patton, S. J.;
Pease, E. K.;
Piepke, A.;
Powell, S.;
Preece, R. M.;
Pushkin, K.;
Ratcliff, B. N.;
Reichenbacher, J.;
Reichhart, L.;
Rhyne, C.;
Rodrigues, J. P.;
Rose, H. J.;
Rosero, R.;
Saba, J. S.;
Sarychev, M.;
Schnee, R. W.;
Schubnell, M. S. G.;
Scovell, P. R.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Skarpaas, K.;
Skulski, W.;
Solovov, V. N.;
Sorensen, P.;
Sosnovtsev, V. V.;
Stancu, I.;
Stark, M. R.;
Stephenson, S.;
Stiegler, T. M.;
Sumner, T. J.;
Sundarnath, K.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W.;
Tennyson, B. P.;
Terman, P. A.;
Thomas, K. J.;
Thomson, J. A.;
Tiedt, D. R.;
To, W. H.;
Tomás, A.;
Tripathi, M.;
Tull, C. E.;
Tvrznikova, L.;
Uvarov, S.;
Va'vra, J.;
van der Grinten, M. G. D.;
Verbus, J. R.;
Vuosalo, C. O.;
Waldron, W. L.;
Wang, L.;
Webb, R. C.;
Wei, W. -Z.;
While, M.;
White, D. T.;
Whitis, T. J.;
Wisniewski, W. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woods, E.;
Woodward, D.;
Worm, S. D.;
Yeh, M.;
Yin, J.;
Young, S. K.;
Zhang, C.
Submitted: 2015-09-09, last modified: 2015-09-23
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of
March 2015 in this Conceptual Design Report. LZ is a second-generation
dark-matter detector with the potential for unprecedented sensitivity to weakly
interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds
of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most
sensitive experiment for WIMPs in this mass region by the end of the decade.
This report describes in detail the design of the LZ technical systems.
Expected backgrounds are quantified and the performance of the experiment is
presented. The LZ detector will be located at the Sanford Underground Research
Facility in South Dakota. The organization of the LZ Project and a summary of
the expected cost and current schedule are given.
[5]
oai:arXiv.org:1112.1481 [pdf] - 1092209
Position Reconstruction in a Dual Phase Xenon Scintillation Detector
Solovov, V. N.;
Belov, V. A.;
Akimov, D. Yu.;
Araújo, H. M.;
Barnes, E. J.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Lüscher, R.;
Majewski, P.;
Murphy, A. St J.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Silva, C.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-12-07, last modified: 2012-09-26
We studied the application of statistical reconstruction algorithms, namely
maximum likelihood and least squares methods, to the problem of event
reconstruction in a dual phase liquid xenon detector. An iterative method was
developed for in-situ reconstruction of the PMT light response functions from
calibration data taken with an uncollimated gamma-ray source. Using the
techniques described, the performance of the ZEPLIN-III dark matter detector
was studied for 122 keV gamma-rays. For the inner part of the detector (R<100
mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the
horizontal plane for primary and secondary scintillation, respectively. An
energy resolution of 8.1% FWHM was achieved at that energy. The possibility of
using this technique for improving performance and reducing cost of
scintillation cameras for medical applications is currently under study.
[6]
oai:arXiv.org:1110.4769 [pdf] - 1085051
WIMP-nucleon cross-section results from the second science run of
ZEPLIN-III
Akimov, D. Yu.;
Araujo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Bewick, A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Jones, W. G.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Murphy, A. StJ.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-10-21, last modified: 2011-12-16
We report experimental upper limits on WIMP-nucleon elastic scattering cross
sections from the second science run of ZEPLIN-III at the Boulby Underground
Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days
of continuous operation between June 2010 and May 2011. A total of eight events
was observed in the signal acceptance region in the nuclear recoil energy range
7-29 keV, which is compatible with background expectations. This allows the
exclusion of the scalar cross-section above 4.8E-8 pb near 50 GeV/c^2 WIMP mass
with 90% confidence. Combined with data from the first run, this result
improves to 3.9E-8 pb. The corresponding WIMP-neutron spin-dependent
cross-section limit is 8.0E-3 pb. The ZEPLIN programme reaches thus its
conclusion at Boulby, having deployed and exploited successfully three liquid
xenon experiments of increasing reach.
[7]
oai:arXiv.org:1111.2248 [pdf] - 1091528
Quenching Factor for Low Energy Nuclear Recoils in a Plastic
Scintillator
Reichhart, L.;
Akimov, D. Yu.;
Araujo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Francis, V.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Murphy, A. St J.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-11-09
Plastic scintillators are widely used in industry, medicine and scientific
research, including nuclear and particle physics. Although one of their most
common applications is in neutron detection, experimental data on their
response to low-energy nuclear recoils are scarce. Here, the relative
scintillation efficiency for neutron-induced nuclear recoils in a
polystyrene-based plastic scintillator (UPS-923A) is presented, exploring
recoil energies between 125 keV and 850 keV. Monte Carlo simulations,
incorporating light collection efficiency and energy resolution effects, are
used to generate neutron scattering spectra which are matched to observed
distributions of scintillation signals to parameterise the energy-dependent
quenching factor. At energies above 300 keV the dependence is reasonably
described using the semi-empirical formulation of Birks and a kB factor of
(0.014+/-0.002) g/MeVcm^2 has been determined. Below that energy the measured
quenching factor falls more steeply than predicted by the Birks formalism.
[8]
oai:arXiv.org:1106.0808 [pdf] - 1077078
ZE3RA: The ZEPLIN-III Reduction and Analysis Package
Neves, F.;
Akimov, D. Yu.;
Araújo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Lüscher, R.;
Majewski, P.;
Murphy, A. St J.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Rodrigues, S.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-06-04
ZE3RA is the software package responsible for processing the raw data from
the ZEPLIN-III dark matter experiment and its reduction into a set of
parameters used in all subsequent analyses. The detector is a liquid xenon time
projection chamber with scintillation and electroluminescence signals read out
by an array of 31 photomultipliers. The dual range 62-channel data stream is
optimised for the detection of scintillation pulses down to a single
photoelectron and of ionisation signals as small as those produced by single
electrons. We discuss in particular several strategies related to data
filtering, pulse finding and pulse clustering which are tuned to recover the
best electron/nuclear recoil discrimination near the detection threshold, where
most dark matter elastic scattering signatures are expected. The software was
designed assuming only minimal knowledge of the physics underlying the
detection principle, allowing an unbiased analysis of the experimental results
and easy extension to other detectors with similar requirements.
[9]
oai:arXiv.org:1103.0393 [pdf] - 385243
Performance of the veto detector incorporated into the ZEPLIN-III
experiment
Ghag, C.;
Akimov, D. Yu.;
Araújo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
DeViveiros, L.;
Edwards, B.;
Francis, V.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Lüscher, R.;
Lyons, K.;
Majewski, P.;
St, A.;
Murphy, J.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Thorne, C.;
Walker, R. J.
Submitted: 2011-03-02, last modified: 2011-05-01
The ZEPLIN-III experiment is operating in its second phase at the Boulby
Underground Laboratory in search of dark matter WIMPs. The major upgrades to
the instrument over its first science run include lower background
photomultiplier tubes and installation of a plastic scintillator veto system.
Performance results from the veto detector using calibration and science data
in its first six months of operation in coincidence with ZEPLIN-III are
presented. With fully automated operation and calibration, the veto system has
maintained high stability and achieves near unity live time relative to
ZEPLIN-III. Calibrations with a neutron source demonstrate a rejection of 60%
of neutron-induced nuclear recoils in ZEPLIN-III that might otherwise be
misidentified as WIMPs. This tagging efficiency reduces the expected untagged
nuclear recoil background from neutrons during science data taking to a very
low rate of ~0.2 events per year in the WIMP acceptance region. Additionally,
the veto detector provides rejection of 28% of gamma-ray induced background
events, allowing the sampling of the dominant source of background in
ZEPLIN-III - multiple scatter gamma-rays with rare topologies. Since WIMPs will
not be tagged by the veto detector, and tags due to gamma-rays and neutrons are
separable, this population of multiple scatter events may be characterised
without biasing the analysis of candidate WIMP signals in the data.
[10]
oai:arXiv.org:1004.4207 [pdf] - 325335
The ZEPLIN-III Anti-Coincidence Veto Detector
Akimov, D. Yu.;
Araujo, H. M.;
Barnes, E. J.;
Belov, V. A.;
Burenkov, A. A.;
Chepel, V.;
Currie, A.;
Edwards, B.;
Francis, V.;
Ghag, C.;
Hollingsworth, A.;
Horn, M.;
Kalmus, G. E.;
Kobyakin, A. S.;
Kovalenko, A. G.;
Lebedenko, V. N.;
Lindote, A.;
Lopes, M. I.;
Luscher, R.;
Lyons, K.;
Majewski, P.;
Murphy, A. StJ.;
Neves, F.;
Paling, S. M.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Reichhart, L.;
Scovell, P. R.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Stekhanov, V. N.;
Sumner, T. J.;
Taylor, R.;
Thorne, C.;
Walker, R. J.
Submitted: 2010-04-23, last modified: 2010-04-27
The design, optimisation and construction of an anti-coincidence veto
detector to complement the ZEPLIN-III direct dark matter search instrument is
described. One tonne of plastic scintillator is arranged into 52 bars
individually read out by photomultipliers and coupled to a gadolinium-loaded
passive polypropylene shield. Particular attention has been paid to
radiological content. The overall aim has been to achieve a veto detector of
low threshold and high efficiency without the creation of additional background
in ZEPLIN-III, all at a reasonable cost. Extensive experimental measurements of
the components have been made, including radioactivity levels and performance
characteristics. These have been used to inform a complete end-to-end Monte
Carlo simulation that has then been used to calculate the expected performance
of the new instrument, both operating alone and as an anti-coincidence detector
for ZEPLIN-III. The veto device will be capable of rejecting over 65% of
coincident nuclear recoil events from neutron background in the energy range of
interest in ZEPLIN-III. This will reduce the background in ZEPLIN-III from ~0.4
to ~0.14 events per year in the WIMP acceptance region, a significant factor in
the event of a non-zero observation. Furthermore, in addition to providing
valuable diagnostic capabilities, the veto is capable of tagging over 15% for
gamma-ray rejection, all whilst contributing no significant additional
background. In conjunction with the replacement of the internal ZEPLIN-III
photomultiplier array, the new veto is expected to improve significantly the
sensitivity of the ZEPLIN-III instrument to dark matter, allowing spin
independent WIMP-nucleon cross sections below 1E-8 pb to be probed.
[11]
oai:arXiv.org:astro-ph/0605500 [pdf] - 82187
The ZEPLIN-III dark matter detector: instrument design, manufacture and
commissioning
Akimov, D. Yu.;
Alner, G. J.;
Araujo, H. M.;
Bewick, A.;
Bungau, C.;
Burenkov, A. A.;
Carson, M. J.;
Chepel, V.;
Cline, D.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Chag, C.;
Hollingworth, R. J.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Kirkpatrick, J.;
Kovalenko, A.;
Kudryavtsev, V. A.;
Kuznetsov, I. S.;
Lawson, T.;
Lebedenko, V. N.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
McMillan, J. E.;
Morgan, B.;
Muna, D.;
Murphy, A. S.;
Neves, F.;
Nicklin, G. G.;
Paling, S. M.;
Muna, D.;
da Cunha, J. Pinto;
Plank, S. J. S.;
Preece, R.;
Quenby, J. J.;
Robinson, M.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Stekhanov, V.;
Sumner, T. J.;
Thorne, C.;
Tovey, D. R.;
Tziaferi, E.;
Walker, R. J.;
Wang, H.;
White, J.;
Wolfs, F.
Submitted: 2006-05-19
We present details of the technical design and manufacture of the ZEPLIN-III
dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures
both the scintillation light and the ionisation charge generated in the liquid
by interacting particles and radiation. The instrument design is driven by both
the physics requirements and by the technology requirements surrounding the use
of liquid xenon. These include considerations of key performance parameters,
such as the efficiency of scintillation light collection, restrictions placed
on the use of materials to control the inherent radioactivity levels,
attainment of high vacuum levels and chemical contamination control. The
successful solution has involved a number of novel design and manufacturing
features which will be of specific use to future generations of direct dark
matter search experiments as they struggle with similar and progressively more
demanding requirements.
[12]
oai:arXiv.org:astro-ph/0603243 [pdf] - 80452
The ZEPLIN-III dark matter detector: performance study using an
end-to-end simulation tool
Araujo, H. M.;
Akimov, D. Yu.;
Alner, G. J.;
Bewick, A.;
Bungau, C.;
Camanzi, B.;
Carson, M. J.;
Chepel, V.;
Chagani, H.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Ghag, C.;
Hollingworth, R.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Kirkpatrick, J.;
Kovalenko, A.;
Kudryavtsev, V. A.;
Lebedenko, V. N.;
Lawson, T.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Mavrokoridis, K.;
McMillan, J.;
Morgan, B.;
Muna, D.;
Murphy, A. S.;
Neves, F.;
Nicklin, G.;
Paling, S.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Robinson, M.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Stekhanov, V.;
Sumner, T. J.;
Tovey, D. R.;
Thorne, C.;
Tziaferi, E.;
Walker, R. J.
Submitted: 2006-03-09
We present results from a GEANT4-based Monte Carlo tool for end-to-end
simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase
detector which measures both the scintillation light and the ionisation charge
generated in liquid xenon by interacting particles and radiation. The software
models the instrument response to radioactive backgrounds and calibration
sources, including the generation, ray-tracing and detection of the primary and
secondary scintillations in liquid and gaseous xenon, and subsequent processing
by data acquisition electronics. A flexible user interface allows easy
modification of detector parameters at run time. Realistic datasets can be
produced to help with data analysis, an example of which is the position
reconstruction algorithm developed from simulated data. We present a range of
simulation results confirming the original design sensitivity of a few times
$10^{-8}$ pb to the WIMP-nucleon cross-section.
[13]
oai:arXiv.org:physics/9704021 [pdf] - 119221
Low-Background Experiments with High Pressure Gas Scintillation
Proportional Detector
Submitted: 1997-04-16
A scintillation proportional counter with wavelength shifting fiber readout
filled with Xe or Kr under a pressure of up to 20 atm is proposed for the
low-background experiments on search for dark matter of the Universe and
2K-decay of 78 Kr.
[14]
oai:arXiv.org:hep-ex/9703011 [pdf] - 113379
Development of High Pressure Xe Scintillation Proportional Counter for
Experiments in "Low-Background" Physics
Submitted: 1997-03-20
Characteristics of a scintillation proportional counter with WLS fiber optics
readout is described. The possibility of detection of the proportional
scintillation signal produced by the single electron of primary ionization is
shown. The counter can be applied for the experiments in "low--background"
physics which require a low energy threshold.