sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Agnese, P.

Normalized to: Agnese, P.

5 article(s) in total. 96 co-authors, from 1 to 4 common article(s). Median position in authors list is 6,0.

[1]  oai:arXiv.org:1007.2168  [pdf] - 1033659
CEA Bolometer Arrays: the First Year in Space
Comments: 11 pages, 11 figures, Proceedings of the SPIE conference, paper 7741-1
Submitted: 2010-07-13
The CEA/LETI and CEA/SAp started the development of far-infrared filled bolometer arrays for space applications over a decade ago. The unique design of these detectors makes possible the assembling of large focal planes comprising thousands of bolometers running at 300 mK with very low power dissipation. Ten arrays of 16x16 pixels were thoroughly tested on the ground, and integrated in the Herschel/PACS instrument before launch in May 2009. These detectors have been successfully commissioned and are now operating in their nominal environment at the second Lagrangian point of the Earth-Sun system. In this paper we briefly explain the functioning of CEA bolometer arrays, and we present the properties of the detectors focusing on their noise characteristics, the effect of cosmic rays on the signal, the repeatability of the measurements, and the stability of the system.
[2]  oai:arXiv.org:1005.1487  [pdf] - 1026738
The Photodetector Array Camera and Spectrometer (PACS) on the Herschel Space Observatory
Comments:
Submitted: 2010-05-10, last modified: 2010-05-20
The Photodetector Array Camera and Spectrometer (PACS) is one of the three science instruments on ESA's far infrared and submillimetre observatory. It employs two Ge:Ga photoconductor arrays (stressed and unstressed) with 16x25 pixels, each, and two filled silicon bolometer arrays with 16x32 and 32x64 pixels, respectively, to perform integral-field spectroscopy and imaging photometry in the 60-210\mu\ m wavelength regime. In photometry mode, it simultaneously images two bands, 60-85\mu\ m or 85-125\mu\m and 125-210\mu\ m, over a field of view of ~1.75'x3.5', with close to Nyquist beam sampling in each band. In spectroscopy mode, it images a field of 47"x47", resolved into 5x5 pixels, with an instantaneous spectral coverage of ~1500km/s and a spectral resolution of ~175km/s. We summarise the design of the instrument, describe observing modes, calibration, and data analysis methods, and present our current assessment of the in-orbit performance of the instrument based on the Performance Verification tests. PACS is fully operational, and the achieved performance is close to or better than the pre-launch predictions.
[3]  oai:arXiv.org:astro-ph/0606623  [pdf] - 83063
The Herschel/PACS 2560 bolometers imaging camera
Comments: 12 pages, 14 figures. To appear in Proc. SPIE 6265, "Space Telescopes and Instrumentation I", 2006 May 24-31, Orlando, Florida USA (6265-11). Higher resolution of the article available on demand (email nbillot at cea.fr)
Submitted: 2006-06-26
The development program of the flight model imaging camera for the PACS instrument on-board the Herschel spacecraft is nearing completion. This camera has two channels covering the 60 to 210 microns wavelength range. The focal plane of the short wavelength channel is made of a mosaic of 2x4 3-sides buttable bolometer arrays (16x16 pixels each) for a total of 2048 pixels, while the long wavelength channel has a mosaic of 2 of the same bolometer arrays for a total of 512 pixels. The 10 arrays have been fabricated, individually tested and integrated in the photometer. They represent the first filled arrays of fully collectively built bolometers with a cold multiplexed readout, allowing for a properly sampled coverage of the full instrument field of view. The camera has been fully characterized and the ground calibration campaign will take place after its delivery to the PACS consortium in mid 2006. The bolometers, working at a temperature of 300 mK, have a NEP close to the BLIP limit and an optical bandwidth of 4 to 5 Hz that will permit the mapping of large sky areas. This paper briefly presents the concept and technology of the detectors as well as the cryocooler and the warm electronics. Then we focus on the performances of the integrated focal planes (responsivity, NEP, low frequency noise, bandwidth).
[4]  oai:arXiv.org:astro-ph/0606436  [pdf] - 82876
A study on the use of the PACS bolometer arrays for submillimeter ground-based telescopes
Comments: 9 pages, 12 figures, to be published in the Proceedings of SPIE Vol. 6275, "Astronomical Telescopes and Instrumentation, Millimeter and Submillimeter Detectors and Instrumentation for Astronomy III"
Submitted: 2006-06-18
A new kind of bolometric architecture has been successfully developed for the PACS photometer onboard the Herschel submillimeter observatory. These new generation CCD-like arrays are buttable and enable the conception of large fully sampled focal planes. We present a feasibility study of the adaptation of these bolometer arrays to ground-based submillimeter telescopes. We have developed an electro-thermal numerical model to simulate the performances of the bolometers under specific ground-based conditions (different wavelengths and background powers for example). This simulation permits to determine the optimal parameters for each condition and shows that the bolometers can be background limited in each transmission window between 200 and 450 microns. We also present a new optical system that enables to have a maximum absorption of the bolometer in each atmospheric windows. The description of this system and measurements are showed.
[5]  oai:arXiv.org:astro-ph/0603086  [pdf] - 80295
Recent Achievements on the development of the Herschel/PACS Bolometer arrays
Comments: Proccedings of the 'Beaune 2005: New Developement In Photodetection International Conference' submitted to NIM section A
Submitted: 2006-03-03
A new type of bolometer arrays sensitive in the Far Infrared and Submillimeter range has been developped and manufactured by CEA/LETI/SLIR and will be integrated in the PACS instrument onboard the Herschel Space Observatory (launch date 2008). The main innovations are their collective manufacturing technique (production of 3-side buttable 16x16 arrays) and their high mapping efficiency (large format detector and instantaneous Nyquist sampling). Their measured NEP is 2x10^-16 W/Hz^-0.5 and their thermometric passband about 4-5 Hz. In this paper we describe CEA bolometers and present the results obtained during the last test campaign.