Normalized to: Agnese, P.
[1]
oai:arXiv.org:1007.2168 [pdf] - 1033659
CEA Bolometer Arrays: the First Year in Space
Billot, Nicolas;
Sauvage, M.;
Rodriguez, L.;
Horeau, B.;
Kiss, C.;
Aussel, H.;
Okumura, K.;
Boulade, O.;
Altieri, B.;
Poglitsch, A.;
Agnese, P.
Submitted: 2010-07-13
The CEA/LETI and CEA/SAp started the development of far-infrared filled
bolometer arrays for space applications over a decade ago. The unique design of
these detectors makes possible the assembling of large focal planes comprising
thousands of bolometers running at 300 mK with very low power dissipation. Ten
arrays of 16x16 pixels were thoroughly tested on the ground, and integrated in
the Herschel/PACS instrument before launch in May 2009. These detectors have
been successfully commissioned and are now operating in their nominal
environment at the second Lagrangian point of the Earth-Sun system. In this
paper we briefly explain the functioning of CEA bolometer arrays, and we
present the properties of the detectors focusing on their noise
characteristics, the effect of cosmic rays on the signal, the repeatability of
the measurements, and the stability of the system.
[2]
oai:arXiv.org:1005.1487 [pdf] - 1026738
The Photodetector Array Camera and Spectrometer (PACS) on the Herschel
Space Observatory
Poglitsch, A.;
Waelkens, C.;
Geis, N.;
Feuchtgruber, H.;
Vandenbussche, B.;
Rodriguez, L.;
Krause, O.;
Renotte, E.;
van Hoof, C.;
Saraceno, P.;
Cepa, J.;
Kerschbaum, F.;
Agnese, P.;
Ali, B.;
Altieri, B.;
Andreani, P.;
Augueres, J. -L.;
Balog, Z.;
Barl, L.;
Bauer, O. H.;
Belbachir, N.;
Benedettini, M.;
Billot, N.;
Boulade, O.;
Bischof, H.;
Blommaert, J.;
Callut, E.;
Cara, C.;
Cerulli, R.;
Cesarsky, D.;
Contursi, A.;
Creten, Y.;
De Meester, W.;
Doublier, V.;
Doumayrou, E.;
Duband, L.;
Exter, K.;
Genzel, R.;
Gillis, J. -M.;
Grözinger, U.;
Henning, T.;
Herreros, J.;
Huygen, R.;
Inguscio, M.;
Jakob, G.;
Jamar, C.;
Jean, C.;
de Jong, J.;
Katterloher, R.;
Kiss, C.;
Klaas, U.;
Lemke, D.;
Lutz, D.;
Madden, S.;
Marquet, B.;
Martignac, J.;
Mazy, A.;
Merken, P.;
Montfort, F.;
Morbidelli, L.;
Müller, T.;
Nielbock, M.;
Okumura, K.;
Orfei, R.;
Ottensamer, R.;
Pezzuto, S.;
Popesso, P.;
Putzeys, J.;
Regibo, S.;
Reveret, V.;
Royer, P.;
Sauvage, M.;
Schreiber, J.;
Stegmaier, J.;
Schmitt, D.;
Schubert, J.;
Sturm, E.;
Thiel, M.;
Tofani, G.;
Vavrek, R.;
Wetzstein, M.;
Wieprecht, E.;
Wiezorrek, E.
Submitted: 2010-05-10, last modified: 2010-05-20
The Photodetector Array Camera and Spectrometer (PACS) is one of the three
science instruments on ESA's far infrared and submillimetre observatory. It
employs two Ge:Ga photoconductor arrays (stressed and unstressed) with 16x25
pixels, each, and two filled silicon bolometer arrays with 16x32 and 32x64
pixels, respectively, to perform integral-field spectroscopy and imaging
photometry in the 60-210\mu\ m wavelength regime. In photometry mode, it
simultaneously images two bands, 60-85\mu\ m or 85-125\mu\m and 125-210\mu\ m,
over a field of view of ~1.75'x3.5', with close to Nyquist beam sampling in
each band. In spectroscopy mode, it images a field of 47"x47", resolved into
5x5 pixels, with an instantaneous spectral coverage of ~1500km/s and a spectral
resolution of ~175km/s. We summarise the design of the instrument, describe
observing modes, calibration, and data analysis methods, and present our
current assessment of the in-orbit performance of the instrument based on the
Performance Verification tests. PACS is fully operational, and the achieved
performance is close to or better than the pre-launch predictions.
[3]
oai:arXiv.org:astro-ph/0606623 [pdf] - 83063
The Herschel/PACS 2560 bolometers imaging camera
Billot, Nicolas;
Agnese, Patrick;
Augueres, Jean-Louis;
Beguin, Alain;
Bouere, Andre;
Boulade, Olivier;
Cara, Christophe;
Cloue, Christelle;
Doumayrou, Eric;
Duband, Lionel;
Horeau, Benoit;
Mer, Isabelle Le;
Pennec, Jean Le;
Martignac, Jerome;
Okumura, Koryo;
Reveret, Vincent;
Sauvage, Marc;
Simoens, Francois;
Vigroux, Laurent
Submitted: 2006-06-26
The development program of the flight model imaging camera for the PACS
instrument on-board the Herschel spacecraft is nearing completion. This camera
has two channels covering the 60 to 210 microns wavelength range. The focal
plane of the short wavelength channel is made of a mosaic of 2x4 3-sides
buttable bolometer arrays (16x16 pixels each) for a total of 2048 pixels, while
the long wavelength channel has a mosaic of 2 of the same bolometer arrays for
a total of 512 pixels. The 10 arrays have been fabricated, individually tested
and integrated in the photometer. They represent the first filled arrays of
fully collectively built bolometers with a cold multiplexed readout, allowing
for a properly sampled coverage of the full instrument field of view. The
camera has been fully characterized and the ground calibration campaign will
take place after its delivery to the PACS consortium in mid 2006. The
bolometers, working at a temperature of 300 mK, have a NEP close to the BLIP
limit and an optical bandwidth of 4 to 5 Hz that will permit the mapping of
large sky areas. This paper briefly presents the concept and technology of the
detectors as well as the cryocooler and the warm electronics. Then we focus on
the performances of the integrated focal planes (responsivity, NEP, low
frequency noise, bandwidth).
[4]
oai:arXiv.org:astro-ph/0606436 [pdf] - 82876
A study on the use of the PACS bolometer arrays for submillimeter
ground-based telescopes
Submitted: 2006-06-18
A new kind of bolometric architecture has been successfully developed for the
PACS photometer onboard the Herschel submillimeter observatory. These new
generation CCD-like arrays are buttable and enable the conception of large
fully sampled focal planes. We present a feasibility study of the adaptation of
these bolometer arrays to ground-based submillimeter telescopes. We have
developed an electro-thermal numerical model to simulate the performances of
the bolometers under specific ground-based conditions (different wavelengths
and background powers for example). This simulation permits to determine the
optimal parameters for each condition and shows that the bolometers can be
background limited in each transmission window between 200 and 450 microns. We
also present a new optical system that enables to have a maximum absorption of
the bolometer in each atmospheric windows. The description of this system and
measurements are showed.
[5]
oai:arXiv.org:astro-ph/0603086 [pdf] - 80295
Recent Achievements on the development of the Herschel/PACS Bolometer
arrays
Billot, N.;
Agnese, P.;
Boulade, O.;
Cigna, C.;
Doumeyrou, E.;
Horeau, B.;
Lepennec, J.;
Martignac, J.;
Pornin, J. -L.;
Reveret, V.;
Rodriguez, L.;
Sauvage, M.;
Simoens, F.;
Vigroux, L.
Submitted: 2006-03-03
A new type of bolometer arrays sensitive in the Far Infrared and
Submillimeter range has been developped and manufactured by CEA/LETI/SLIR and
will be integrated in the PACS instrument onboard the Herschel Space
Observatory (launch date 2008). The main innovations are their collective
manufacturing technique (production of 3-side buttable 16x16 arrays) and their
high mapping efficiency (large format detector and instantaneous Nyquist
sampling). Their measured NEP is 2x10^-16 W/Hz^-0.5 and their thermometric
passband about 4-5 Hz. In this paper we describe CEA bolometers and present the
results obtained during the last test campaign.