oai:arXiv.org:1509.08358 [pdf] - 1284118
Development of an ELT XAO testbed using a Mach-Zehnder wavefront sensor:
calibration of the deformable mirror
Submitted: 2015-09-28
(abridged) Extreme adaptive optics (XAO) encounters severe difficulties to
cope with the high speed (>1kHz), high accuracy and high order requirements for
future extremely large telescopes. An innovative high order adaptive optics
system using a self-referenced Mach-Zehnder wavefront sensor (MZWFS) allows
counteracting these limitations. This sensor estimates very accurately the
wavefront phase at small spatial scale by measuring intensity differences
between two outputs, with a $\lambda /4$ path length difference between its two
legs, but is limited in dynamic range due to phase ambiguity. During the past
few years, such an XAO system has been studied by our team in the framework of
8-meter class telescopes. In this work, we report on our latest results with
the XAO testbed recently installed in our lab, and dedicated to high contrast
imaging with 30m-class telescopes (such as the E-ELT or the TMT). After
reminding the principle of a MZWFS and describing the optical layout of our
experiment, we will show the results of the assessment of the woofer-tweeter
phase correctors, i.e., a Boston Micromachine continuous membrane deformable
mirror (DM) and a Boulder Nonlinear Systems liquid crystal spatial light
modulator (SLM). In particular, we will detail the calibration of the DM using
Zygo interferometer metrology. Our method consists in the precise measurement
of the membrane deformation while applying a constant deformation to 9 out of
140 actuators at the same time. By varying the poke voltage across the DM
operating range, we propose a simple but efficient way of modeling the DM
influence function using a Gaussian model. Finally, we show the DM flattening
on the MZWFS allowing to compensate for low order aberrations.