sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Aboobaker, A. M.

Normalized to: Aboobaker, A.

12 article(s) in total. 89 co-authors, from 1 to 10 common article(s). Median position in authors list is 2,0.

[1]  oai:arXiv.org:1803.01018  [pdf] - 1783724
The EBEX Balloon Borne Experiment - Detectors and Readout
Comments: Accepted by The Astrophysical Journal Supplement Series (APJS). 49 pages, 28 figures, 11 tables
Submitted: 2018-03-02, last modified: 2018-07-30
EBEX was a long-duration balloon-borne experiment to measure the polarization of the cosmic microwave background. The experiment had three frequency bands centered at 150, 250, and 410 GHz and was the first to use a kilo-pixel array of transition edge sensor (TES) bolometers aboard a balloon platform; shortly after reaching float we operated 504, 342, and 109 TESs at each of the bands, respectively. We describe the design and characterization of the array and the readout system. We give the distributions of measured thermal conductances, normal resistances, and transition temperatures. With the exception of the thermal conductance at 150 GHz. We measured median low-loop-gain time constants $\tau_{0}=$ 88, 46, and 57 ms and compare them to predictions. Two measurements of bolometer absorption efficiency show high ($\sim$0.9) efficiency at 150 GHz and medium ($\sim$0.35, and $\sim$0.25) at the two higher bands, respectively. We measure a median total optical load of 3.6, 5.3 and 5.0 pW absorbed at the three bands, respectively. EBEX pioneered the use of the digital version of the frequency domain multiplexing (FDM) system which multiplexed the bias and readout of 16 bolometers onto two wires. We present accounting of the measured noise equivalent power. The median per-detector noise equivalent temperatures referred to a black body with a temperature of 2.725 K are 400, 920, and 14500 $\mu$K$\sqrt{s}$ for the three bands, respectively. We compare these values to our pre-flight predictions and to a previous balloon payload, discuss the sources of excess noise, and the path for a future payload to make full use of the balloon environment.
[2]  oai:arXiv.org:1711.01314  [pdf] - 1877825
Intensity-Coupled-Polarization in Instruments with a Continuously Rotating Half-Wave Plate
Comments: 43 pages, 12 figures, submitted to the Astrophysical Journal
Submitted: 2017-11-03, last modified: 2018-02-28
We discuss a systematic effect associated with measuring polarization with a continuously rotating half-wave plate. The effect was identified with the data from the E and B Experiment (EBEX), which was a balloon-borne instrument designed to measure the polarization of the CMB as well as that from Galactic dust. The data show polarization fraction larger than 10\% while less than 3\% were expected from instrumental polarization. We give evidence that the excess polarization is due to detector non-linearity in the presence of a continuously rotating HWP. The non-linearity couples intensity signals into polarization. We develop a map-based method to remove the excess polarization. Applying this method for the 150 (250) GHz bands data we find that 81\% (92\%) of the excess polarization was removed. Characterization and mitigation of this effect is important for future experiments aiming to measure the CMB B-modes with a continuously rotating HWP.
[3]  oai:arXiv.org:1703.03847  [pdf] - 1783689
The EBEX Balloon Borne Experiment - Optics, Receiver, and Polarimetry
Comments: 49 pages, 32 figures, submitted to The Astrophysical Journal Supplement
Submitted: 2017-03-10, last modified: 2017-05-30
The E and B Experiment (EBEX) was a long-duration balloon-borne cosmic microwave background polarimeter that flew over Antarctica in 2013. We describe the experiment's optical system, receiver, and polarimetric approach, and report on their in-flight performance. EBEX had three frequency bands centered on 150, 250, and 410 GHz. To make efficient use of limited mass and space we designed a 115 cm$^{2}$sr high throughput optical system that had two ambient temperature mirrors and four anti-reflection coated polyethylene lenses per focal plane. All frequency bands shared the same optical train. Polarimetry was achieved with a continuously rotating achromatic half-wave plate (AHWP) that was levitated with a superconducting magnetic bearing (SMB). Rotation stability was 0.45 % over a period of 10 hours, and angular position accuracy was 0.01 degrees. This is the first use of a SMB in astrophysics. The measured modulation efficiency was above 90 % for all bands. To our knowledge the 109 % fractional bandwidth of the AHWP was the broadest implemented to date. The receiver that contained one lens and the AHWP at a temperature of 4 K, the polarizing grid and other lenses at 1 K, and the two focal planes at 0.25 K performed according to specifications giving focal plane temperature stability with fluctuation power spectrum that had $1/f$ knee at 2 mHz. EBEX was the first balloon-borne instrument to implement technologies characteristic of modern CMB polarimeters including high throughput optical systems, and large arrays of transition edge sensor bolometric detectors with mutiplexed readouts.
[4]  oai:arXiv.org:1702.01861  [pdf] - 1568902
A Double Vacuum Window Mechanism for Space-borne Applications
Comments: 7 pages, 6 Figures, Published in Review of Scientific Instruments
Submitted: 2017-02-06, last modified: 2017-04-26
We present a vacuum window mechanism that is useful for applications requiring two different vacuum windows in series, with one of them movable and resealable. Such applications include space borne instruments that can benefit from a thin vacuum window at low ambient pressures, but must also have an optically open aperture at atmospheric pressures. We describe the implementation and successful operation with the EBEX balloon-borne payload, a millimeter-wave instrument designed to measure the polarization of the cosmic microwave background radiation.
[5]  oai:arXiv.org:1702.07020  [pdf] - 1783687
The EBEX Balloon-Borne Experiment - Gondola, Attitude Control, and Control Software
Comments: 37 pages, 16 figures, accepted for publication in ApJ Supp
Submitted: 2017-02-22, last modified: 2017-04-11
The E and B Experiment (EBEX) was a long-duration balloon-borne instrument designed to measure the polarization of the cosmic microwave background (CMB) radiation. EBEX was the first balloon-borne instrument to implement a kilo-pixel array of transition edge sensor (TES) bolometric detectors and the first CMB experiment to use the digital version of the frequency domain multiplexing system for readout of the TES array. The scan strategy relied on 40 s peak-to-peak constant velocity azimuthal scans. We discuss the unique demands on the design and operation of the payload that resulted from these new technologies and the scan strategy. We describe the solutions implemented including the development of a power system designed to provide a total of at least 2.3 kW, a cooling system to dissipate 590 W consumed by the detectors' readout system, software to manage and handle the data of the kilo-pixel array, and specialized attitude reconstruction software. We present flight performance data showing faultless management of the TES array, adequate powering and cooling of the readout electronics, and constraint of attitude reconstruction errors such that the spurious B-modes they induced were less than 10% of CMB B-mode power spectrum with $r=0.05$.
[6]  oai:arXiv.org:1602.03249  [pdf] - 1356056
A high-resolution pointing system for fast scanning platforms: The EBEX example
Comments: 14 pages, Proceedings of the 2015 IEEE Aerospace Conference
Submitted: 2016-02-09
The E and B experiment (EBEX) is a balloon-borne telescope designed to measure the polarization of the cosmic microwave background with 8' resolution employing a gondola scanning with speeds of order degree per second. In January 2013, EBEX completed 11 days of observations in a flight over Antarctica covering $\sim$ 6000 square degrees of the sky. The payload is equipped with two redundant star cameras and two sets of three orthogonal gyroscopes to reconstruct the telescope attitude. The EBEX science goals require the pointing to be reconstructed to approximately 10" in the map domain, and in-flight attitude control requires the real time pointing to be accurate to $\sim$ 0.5$^{\circ}$ . The high velocity scan strategy of EBEX coupled to its float altitude only permits the star cameras to take images at scan turnarounds, every $\sim$ 40 seconds, and thus requires the development of a pointing system with low noise gyroscopes and carefully controlled systematic errors. Here we report on the design of the pointing system and on a simulation pipeline developed to understand and minimize the effects of systematic errors. The performance of the system is evaluated using the 2012/2013 flight data, and we show that we achieve a pointing error with RMS=25" on 40 seconds azimuth throws, corresponding to an error of $\sim$ 4.6" in the map domain.
[7]  oai:arXiv.org:1601.07923  [pdf] - 1350058
Temperature calibration of the E and B experiment
Comments: 6 pages, 3 figures, Proceedings of the 14th Marcel Grossman Conference
Submitted: 2016-01-28
The E and B Experiment (EBEX) is a balloon-borne polarimeter designed to measure the polarization of the cosmic microwave background radiation and to characterize the polarization of galactic dust. EBEX was launched December 29, 2012 and circumnavigated Antarctica observing $\sim$6,000 square degrees of sky during 11 days at three frequency bands centered around 150, 250 and 410 GHz. EBEX was the first experiment to operate a kilo-pixel array of transition-edge sensor bolometers and a continuously rotating achromatic half-wave plate aboard a balloon platform. It also pioneered the use of detector readout based on digital frequency domain multiplexing. We describe the temperature calibration of the experiment. The gain response of the experiment is calibrated using a two-step iterative process. We use signals measured on passes across the Galactic plane to convert from readout-system counts to power. The effective smoothing scale of the EBEX optics and the star camera-to-detector offset angles are determined through \c{hi}2 minimization using the compact HII region RCW 38. This two-step process is initially performed with parameters measured before the EBEX 2013 flight and then repeated until the calibration factor and parameters converge.
[8]  oai:arXiv.org:1407.6894  [pdf] - 1215912
The performance of the bolometer array and readout system during the 2012/2013 flight of the E and B experiment (EBEX)
Comments: 15 pages, 12 figures, SPIE conference proceedings
Submitted: 2014-07-22
EBEX is a balloon-borne telescope designed to measure the polarization of the cosmic microwave background radiation. During its eleven day science flight in the Austral Summer of 2012, it operated 955 spider-web transition edge sensor (TES) bolometers separated into bands at 150, 250 and 410 GHz. This is the first time that an array of TES bolometers has been used on a balloon platform to conduct science observations. Polarization sensitivity was provided by a wire grid and continuously rotating half-wave plate. The balloon implementation of the bolometer array and readout electronics presented unique development requirements. Here we present an outline of the readout system, the remote tuning of the bolometers and Superconducting QUantum Interference Device (SQUID) amplifiers, and preliminary current noise of the bolometer array and readout system.
[9]  oai:arXiv.org:1007.3672  [pdf] - 1033814
EBEX: A balloon-borne CMB polarization experiment
Comments: 12 pages, 9 figures, Conference proceedings for SPIE Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy V (2010)
Submitted: 2010-07-21
EBEX is a NASA-funded balloon-borne experiment designed to measure the polarization of the cosmic microwave background (CMB). Observations will be made using 1432 transition edge sensor (TES) bolometric detectors read out with frequency multiplexed SQuIDs. EBEX will observe in three frequency bands centered at 150, 250, and 410 GHz, with 768, 384, and 280 detectors in each band, respectively. This broad frequency coverage is designed to provide valuable information about polarized foreground signals from dust. The polarized sky signals will be modulated with an achromatic half wave plate (AHWP) rotating on a superconducting magnetic bearing (SMB) and analyzed with a fixed wire grid polarizer. EBEX will observe a patch covering ~1% of the sky with 8' resolution, allowing for observation of the angular power spectrum from \ell = 20 to 1000. This will allow EBEX to search for both the primordial B-mode signal predicted by inflation and the anticipated lensing B-mode signal. Calculations to predict EBEX constraints on r using expected noise levels show that, for a likelihood centered around zero and with negligible foregrounds, 99% of the area falls below r = 0.035. This value increases by a factor of 1.6 after a process of foreground subtraction. This estimate does not include systematic uncertainties. An engineering flight was launched in June, 2009, from Ft. Sumner, NM, and the long duration science flight in Antarctica is planned for 2011. These proceedings describe the EBEX instrument and the North American engineering flight.
[10]  oai:arXiv.org:1005.3339  [pdf] - 168465
The EBEX Cryostat and Supporting Electronics
Comments: 11 pages, 6 figures, Proceedings of the 12th Marcel Grossman Conference
Submitted: 2010-05-18
We describe the cryostat and supporting electronics for the EBEX experiment. EBEX is a balloon-borne polarimeter designed to measure the B-mode polarization of the cosmic microwave background radiation. The instrument includes a 1.5 meter Gregorian-type telescope and 1432 bolometric transition edge sensor detectors operating at 0.3 K. Electronics for monitoring temperatures and controlling cryostat refrigerators is read out over CANbus. A timing system ensures the data from all subsystems is accurately synchronized. EBEX completed an engineering test flight in June 2009 during which the cryogenics and supporting electronics performed according to predictions. The temperatures of the cryostat were stable, and an analysis of a subset of the data finds no scan synchronous signal in the cryostat temperatures. Preparations are underway for an Antarctic flight.
[11]  oai:arXiv.org:astro-ph/0701020  [pdf] - 88149
Optical Design of the Atacama Cosmology Telescope and the Millimeter Bolometric Array Camera
Comments: 23 pages. Accepted for publication in Applied Optics. Several minor clarifications added after peer review
Submitted: 2006-12-31, last modified: 2007-02-02
The Atacama Cosmology Telescope is a 6-meter telescope designed to map the Cosmic Microwave Background simultaneously at 145 GHz, 215 GHz, and 280 GHz with arcminute resolution. Each frequency will have a 32 by 32 element focal plane array of TES bolometers. This paper describes the design of the telescope and the cold reimaging optics, which is optimized for millimeter-wave observations with these sensitive detectors.
[12]  oai:arXiv.org:astro-ph/0403137  [pdf] - 63328
CMB Observations with a Compact Heterogeneous 150 GHz Interferometer in Chile
Comments: 12 pages, 4 figures. v2: Final ApJS version; rewritten analysis section made more clear
Submitted: 2004-03-05, last modified: 2005-01-27
We report on the design, first observing season, and analysis of data from a new prototype millimeter-wave interferometer, MINT. MINT consists of four 145 GHz SIS mixers operating in double-sideband mode in a compact heterogeneous configuration. The signal band is subdivided by a monolithic channelizer, after which the correlations between antennas are performed digitally. The typical receiver sensitivity in a 2 GHz band is 1.4 mK sqrt(s). MINT observed the cosmic microwave background (CMB) from the Chilean Altiplano. The site has a median nighttime atmospheric temperature of 9 K at zenith (exclusive of the CMB). Observations of Mars, Jupiter, and a telescope-mounted calibration source establish the system's phase and magnitude stability. MINT is the first CMB-dedicated interferometer to operate above 50 GHz. The same type of system can be used to probe the Sunyaev-Zel'dovich effect in galaxy clusters near the SZ null at 217 GHz. We present an analysis of sideband-separated, digitally sampled data recorded by the array. Based on 215 hours of data taken in late 2001, we set an upper limit on the CMB anisotropy in a band of width Delta ell=700 around ell=1540 of delta T < 105 microK (95% conf). Increased sensitivity can be achieved with more integration time, greater bandwidth, and more elements.