Abdulsttar, Marwah M.
Normalized to: Abdulsttar, M.
3 article(s) in total. 2 co-authors, from 2 to 3 common article(s). Median position in authors list is 1,0.
[1]
oai:arXiv.org:1711.00512 [pdf] - 1590625
Cherenkov Light Lateral Distribution Function Estimation as a Function
of Zenith Angle
Submitted: 2017-10-27
The simulation of Cherenkov light lateral distribution function (CLLDF) in
Extensive Air Showers (EAS) was performed by using the Monte Carlo CORSIKA code
for configurations of Tunka-133 EAS Cherenkov array. This simulation was
carried out for different primary particles (e+, e-, p, O, Ar and Fe) around
the knee region with the energy 3.10^15 eV at different zenith angles. By
depending on the Breit-Wigner function a parameterization of CLLDF was
reconstructed on the basis of this simulation as a function of the zenith
angle. The parameterized CLLDF was verified for four fixed zenith angles in
comparison with the simulation that performed using CORSIKA code for each
primary particle.
[2]
oai:arXiv.org:1612.08603 [pdf] - 1533874
Demonstrating of Cosmic Ray Characteristics by Estimating the Cherenkov
Light Lateral Distribution Function for Yakutsk Array as a Function of the
Zenith Angle
Submitted: 2016-12-15
Cherenkov light lateral distribution function (CLLDF) in Extensive Air
Showers (EAS) for different primary particles (e-, n , p, F, K and Fe) was
simulated using CORSIKA code for conditions and configurations of Yakutsk EAS
array with the fixed primary energy 3 PeV around the knee region at different
zenith angles. Basing on the results of CLLDF numerical simulation, sets of
approximated functions are reconstructed for different primary particles as a
function of the zenith angle. A comparison of the parameterized CLLDF with that
simulated with Yakutsk EAS array is verified. The parameterized CLLDF also is
compared with that measured on the Yakutsk EAS array.
[3]
oai:arXiv.org:1612.08604 [pdf] - 1533875
Parameterization of Cherenkov Light Lateral Distribution Function as a
Function of the Zenith Angle around the Knee Region
Submitted: 2016-12-15
Cherenkov light lateral distribution function (CLLDF) simulation was
fulfilled using CORSIKA code for configurations of Tunka EAS array of different
zenith angles. The parameterization of the CLLDF was carried out as a function
of the distance from the shower core in extensive air showers (EAS) and zenith
angle on the basis of the CORSIKA simulation of primary proton around the knee
region with the energy 3.10^15 eV at different zenith angles. The parameterized
CLLDF is verified in comparison with the simulation that performed using
CORSIKA code for two zenith angles.