Normalized to: A., K.
[1]
oai:arXiv.org:1811.02907 [pdf] - 1809600
Follow-up Timing of Three GMRT Pulsars
Submitted: 2018-11-07
We report on the results of multi-frequency follow-up observations of three
pulsars (PSRs J0026+6320, J2208+5500 and J2217+5733) discovered with the Giant
Metrewave Radio Telescope (GMRT). These observations were carried out with the
GMRT and the Ooty Radio Telescope (ORT). We report improved timing solutions
for all three pulsars. For PSR J2208+5500, we estimate the nulling fraction to
be 53(3)\%. The steep spectrum of this pulsar, its single component profile,
and narrow pulse width suggest its single component to be a core component. If
so, this significant cessation of emission in a core component is inconsistent
with a geometric origin of nulls, such as those due to `empty' sightline
traverses, and more likely due to intrinsic changes in the pulsar
magnetosphere. We have measured scatter-broadening timescales at 325 and 610
MHz for PSRs J0026+6320 and J2217+5733. The implied scatter-broadening
frequency scaling index of $-$2.9 for both pulsars is different from that
expected assuming Kolmogorov turbulence in the interstellar medium. We also
report spectral indices, obtained from imaging observations, for all three
pulsars for the first time. The spectra for two of these pulsars indicate a
possible spectral turnover between 100$-$300 MHz. Multi-frequency timing
analyses carried out for these pulsars have enabled us to determine dispersion
measures (DMs) with accuracies of 0.01 pc cm\sups{--3}. This demonstrates the
usefulness of quasi-simultaneous multi-frequency multi-epoch timing
observations with the GMRT and the ORT for studying variations in DM for
millisecond pulsars.
[2]
oai:arXiv.org:1805.05260 [pdf] - 1686923
GMRT Galactic Plane Pulsar and Transient Survey and the Discovery of PSR
J1838+1523
Submitted: 2018-05-14
We report the results of a blind pulsar survey carried out with the Giant
Metrewave Radio Telescope (GMRT) at 325 MHz. The survey covered about 10\% of
the region between Galactic longitude 45$^{\circ} < l <$ 135$^{\circ}$ and
Galactic latitude 1$^{\circ} < |b| <$ 10$^{\circ}$ with a dwell time of 1800 s,
resulting in the detection of 28 pulsars. One of these, PSR J1838+1523, was
previously unknown and has a period of 549 ms and a dispersion measure of 68 pc
cm\sups{$-$3}. We also present the timing solution of this pulsar obtained from
multi-frequency timing observations carried out with the GMRT and the Ooty
Radio Telescope. The measured flux density of this pulsar is 4.3$\pm$1.8 and
1.2$\pm$0.7 mJy at 325 and 610 MHz, respectively. This implies a spectral index
of $-$2$\pm$0.8, thus making the expected flux density at 1.4 GHz to be about
0.2 mJy, which would be just detectable in the high frequency pulsar surveys
like the Northern High Time Resolution Universe pulsar survey. This discovery
underlines the importance of low frequency pulsar surveys in detecting steep
spectrum pulsars, thus providing complementary coverage of the pulsar
population.
[3]
oai:arXiv.org:1502.02161 [pdf] - 1276046
Chemical Abundances in the Globular Clusters NGC 6229 and NGC 6779
Submitted: 2015-02-07
Long-slit medium-resolution spectra of the Galactic globular clusters (GCs)
NGC6229 and NGC6779, obtained with the CARELEC spectrograph at the 1.93-m
telescope of the Haute-Provence observatory, have been used to determine the
age, helium abundance (Y), and metallicity [Fe/H] as well as the first estimate
of the abundances of C, N, O, Mg, Ca, Ti, and Cr for these objects. We solved
this task by comparing the observed spectra and the integrated synthetic
spectra, calculated with the use of the stellar atmosphere models with the
parameters preset for the stars from these clusters. The model mass estimates,
$T_{\rm eff}$, and log~g were derived by comparing the observed
"color-magnitude" diagrams and the theoretical isochrones. The summing-up of
the synthetic blanketed stellar spectra was conducted according to the Chabrier
mass function. To test the accuracy of the results, we estimated the chemical
abundances, [Fe/H], $\log~t$, and $Y$ for the NGC5904 and NGC6254 clusters,
which, according to the literature, are considered to be the closest analogues
of the two GCs of our study. Using the medium-resolution spectra from the
library of Schiavon et al., we obtained for these two clusters a satisfactory
agreement with the reported estimates for all the parameters within the errors.
We derived the following cluster parameters. NGC6229: [Fe/H]=-1.65 dex, t=12.6
Gyr, Y=0.26, [\alpha/Fe]=0.28 dex; NGC6779: [Fe/H]=-1.9 dex, t=12.6 Gyr,
Y=0.23, [\alpha/Fe]=0.08 dex; NGC5904: [Fe/H]=-1.6 dex, t=12.6 Gyr, Y=0.30,
[\alpha/Fe]=0.35 dex; NGC6254: [Fe/H]=-1.52 dex, t=11.2 Gyr, Y=0.30
[\alpha/Fe]=0.025 dex. The value [\alpha/Fe] denotes the average of the Ca and
Mg abundances.